• Title/Summary/Keyword: Phase Comparison

Search Result 1,886, Processing Time 0.039 seconds

The comparison of clinical changes during maintenance phase after non-surgical or surgical therapy of chronic periodontitis (만성 치주염에서 비외과적 또는 외과적 치주치료 후 유지관리기 동안 임상적 변화의 비교)

  • Kim, Jee-Hyun;Chung, Hyun-Ju
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.1
    • /
    • pp.69-84
    • /
    • 2006
  • Reports on the comparison of clinical effect between non-surgical and surgical therapy, and the change of the clinical parameters during maintenance phase have been rarely presented in Korea. This study was to observe the clinical changes during maintenance phase of 6 months in patients with chronic periodontitis treated by non-surgical or surgical therapy in Department of Periodontics, Chonnam National University Hospital. Among the systemically healthy and non-smoking patients with moderate to severe chronic periodontitis, twenty eight patients (mean age: 47.5 years) treated by non-surgical therapy (scaling and root planning) and nineteen patients (mean age: 47.3 years) treated by surgical therapy (flap surgery) were included in this study. The periodontal supportive therapy including recall check and oral hygiene reinforcement was started as maintenance phase since 1 month of healing after treatment. Probing depth, gingival recession. clinical attachment level and tooth mobility were recorded at initial, baseline and 1, 2, 3 and 6 month of maintenance phase. The clinical parameters were compared between the non-surgical and surgical therapies using Student t-test and repeated measure ANOVA by initial probing depth and surfaces. Surgical therapy resulted in greater change in clinical parameters than non-surgical therapy. During the maintenance phase of 6 months, the clinical effects after treatment had been changed in different pattern according to initial probing depth and tooth surface. During maintenance phase, probing depth increased more and gingival recession increased less after surgical therapy, compared to non-surgical therapy. The sites of initial probing depth less than 3 mm lost more clinical attachment level, and the sites of initial probing depth more than 7 mm gained clinical attachment level during maintenance phase after non-surgical therapy, compared to surgical therapy. Non-surgical therapy resulted in greater reduction of tooth mobility than surgical therapy during maintenance phase. These results indicate that the clinical effects of non-surgical or surgical therapy may be different and may change during the maintenance phase.

Automatic carrier phase delay synchronization of PGC demodulation algorithm in fiber-optic interferometric sensors

  • Hou, Changbo;Guo, Shuai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.14 no.7
    • /
    • pp.2891-2903
    • /
    • 2020
  • Phase-generated carrier (PGC) demodulation algorithm is the main demodulation methods in Fiber-optic interferometric sensors (FOISs). The conventional PGC demodulation algorithms are influenced by the carrier phase delay between the interference signal and the carrier signal. In this paper, an automatic carrier phase delay synchronization (CPDS) algorithm based on orthogonal phase-locked technique is proposed. The proposed algorithm can calculate the carrier phase delay value. Then the carrier phase delay can be compensated by adjusting the initial phase of the fundamental carrier and the second-harmonic carrier. The simulation results demonstrate the influence of the carrier phase delay on the demodulation performance. PGC-Arctan demodulation system based on CPDS algorithm is implemented on SoC. The experimental results show that the proposed algorithm is able to obtain and eliminate the carrier phase delay. In comparison to the conventional demodulation algorithm, the signal-to-noise and distortion ratio (SINAD) of the proposed algorithm increases 55.99dB.

A Technology of Microwave Direction Finding with Circular Array Combination Method (원형 배열 복합 방식을 이용한 초고주파 방향 탐지 기술)

  • Lim Joong-Soo;Jung Chul-Gu;Chae Gyoo-Soo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.549-555
    • /
    • 2005
  • This paper describes a microwave direction finding technology which is used for RF signal acquisition and monitoring systems. This paper suggests a direction finding method which use a combination of the amplitude-comparison technology and the phase-comparison technology. The amplitude-comparison technology uses the amplitude difference of the RF signals received from the array antennas of direction finding system and removes the ambiguity of wave incident bearing. The phase-comparison technology uses the phase difference of the RF signals received from the same nay antennas and makes a good direction finding accuracy. The suggested direction finding technology is designed to place 8 array antennas in a $45^{\circ}$ distance around the circle for $360^{\circ}$ azimuth angle. Also it is designed to use the phase difference of the received signals ken two nearby antennas to measure the signal incident direction accurately and to use the amplitude difference to remove the ambiguity of wave incident bearing. The simulation and measurement results are under $0.5^{\circ}$ bearing error in $2.0\~6.0$ GHz when SNR is 30 dB.

Azimuth Accuracy Test of Phase Comparison Direction Finding Method Using F-16 Fighter Scale-down Model (F-16 전투기 축소모델을 사용한 위상비교 방향 탐지 기법의 방위각 정확도 시험)

  • Lim, Joong-Soo;Chae, Gyoo-Soo;Kim, Young-Ho;Kim, Kichul
    • Journal of Convergence for Information Technology
    • /
    • v.7 no.5
    • /
    • pp.83-88
    • /
    • 2017
  • This paper describes the azimuth accuracy test of phase comparison direction finding method using F-16 fighter scale-down model. When the antennas are placed on the bottom of a fighter, reflection signals caused by an aircraft structure arises and an azimuth error occurs. In this research, the F-16 fighter scale-down model was made to 5:1, and five antennas were placed on the bottom of the model, then the radio waves of emitters were received by the antennas in the $0-360^{\circ}$ azimuth angles. The accuracy test was performed by numerically analyzing the phases of the radio waves received by the five antennas. The azimuth error of the phase comparison direction finding with scale-down model was measured to be less than $0.5^{\circ}$ when the signal noise ratio was larger then 0dB, and it could be very useful for the design of the phase comparison direction finding method of the fighter.

IMPLEMENTATION OF A SECOND-ORDER INTERPOLATION SCHEME FOR THE CONVECTIVE TERMS OF A SEMI-IMPLICIT TWO-PHASE FLOW ANALYSIS SOLVER (물-기체 2상 유동 해석을 위한 Semi-Implicit 방법의 대류항에 대한 2차 정확도 확장)

  • Cho, H.K.;Lee, H.D.;Park, I.K.;Jeong, J.J.
    • Journal of computational fluids engineering
    • /
    • v.14 no.4
    • /
    • pp.13-22
    • /
    • 2009
  • A two-phase (gas and liquid) flow analysis solver, named CUPID, has been developed for a realistic simulation of transient two-phase flows in light water nuclear reactor components. In the CUPID solver, a two-fluid three-field model is adopted and the governing equations are solved on unstructured grids for flow analyses in complicated geometries. For the numerical solution scheme, the semi-implicit method of the RELAP5 code, which has been proved to be very stable and accurate for most practical applications of nuclear thermal hydraulics, was used with some modifications for an application to unstructured non-staggered grids. This paper is concerned with the effects of interpolation schemes on the simulation of two-phase flows. In order to stabilize a numerical solution and assure a high numerical accuracy, the second-order upwind scheme is implemented into the CUPID code in the present paper. Some numerical tests have been performed with the implemented scheme and the comparison results between the second-order and first-order upwind schemes are introduced in the present paper. The comparison results among the two interpolation schemes and either the exact solutions or the mesh convergence studies showed the reduced numerical diffusion with the second-order scheme.

Comparison of Three Active-Frequency-Drift Islanding Detection Methods for Single-Phase Grid-Connected Inverters

  • Kan, Jia-rong;Jiang, Hui;Tang, Yu;Wu, Dong-chun;Wu, Yun-ya;Wu, Jiang
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.509-518
    • /
    • 2019
  • A novel islanding detection method is proposed in this paper. It is based on a frequency drooping PLL, which was presented in a previous work. The cause of errors in the non-detection zone (NDZ) of conventional frequency disturbance islanding detection methods (IDM) is analyzed. A frequency drooping phase-locked-loop (FD-PLL) is introduced into a single-phase grid-connected inverter (SPGCI), which can guarantee that grid current is in phase with the grid voltage. A novel FD-PLL IDM is proposed by improving this PLL. In order to verify the performance of the proposed FD-PLL IDM, a full performance comparison between the proposed IDM and typical existing active frequency drift IDMs is carried out, which includes both dynamic performance and steady performance. With the same NDZ, the total harmonic distortion of the grid-current in the dynamic process and steady state is analyzed. The proposed FD-PLL IDM, regardless of the dynamic or steady process, has the best power quality. Experimental and simulation results verify that the proposed FD-PLL IDM has excellent performance.

Tomographic Reconstruction of Two-Phase Flows

  • Ko, Han-Seo;Kim, Yong-Jae
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.4
    • /
    • pp.571-580
    • /
    • 2003
  • Tomography has been investigated to observe bubble behaviors in two-phase flows. A bubbly flow and an annular flow have been reconstructed by tomography methods such as an algebraic reconstruction technique (ART) and a multiplicative algebraic reconstruction technique (MART) . Computer synthesized phantom fields have been used to calculate asymmetric density distributions for limited cases of 3, 5, and 7 projection angles. As a result of comparison of two tomography methods, the MART method has shown a significant improvement in the reconstruction accuracy for analysis of the two-phase flows.

Comparison of SRM rotor position estimation algorithm using flux-current methods (자속 모델 기준 추종방식을 이용한 SRM 회전자 위치평가알고리즘 비교)

  • 안재황
    • Proceedings of the KIPE Conference
    • /
    • 2000.07a
    • /
    • pp.697-700
    • /
    • 2000
  • This paper introduces a new rotor position estimation algorithm for the SRM based on the magnetizing curves of aligned and unaligned rotor positions. The flux linkage is calculated by the measured data from phase voltage and phase current and the calculated data are used as the input of magnetizing profiles for rotor position detection. Each of the magnetizing profiles consisted of the methods using the neural network and fuzzy algorithm And also the optima phase is selected by phase selector. To demonstrate the promise of this approach the proposed rotor position estimation algorithms are verified by the experiment results or variable spee range.

  • PDF

Cogging Force Reduction of Two Phase Linear Hybrid Stepping Motor (2상 선형 하이브리드 스테핑 전동기의 코깅 리플 저감)

  • Hwarg, Tai-Sik;Seok, Jul-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.96-98
    • /
    • 2005
  • This paper presents a new two-phase linear hybrid stepping motors (LHSM), which has two windings per phase and one of them shares the other phase winding. The proposed motor shows a unique ability to deliver low cogging force without any particular complex control scheme and additional power electronics hardware in micro stepping control. An analytical and experimental comparison between conventional and proposed LHSM is evaluated to confirm the effectiveness of the proposed design.

  • PDF

Linear Solvation Energy Comparison Study in Normal Phase Liquid Chromatography Ⅰ (정상 액체크로마토그래피에서의 선형 용매화에너지 비교법 연구 Ⅰ)

  • Choe, Jang Deok;Jeong, Won Jo
    • Journal of the Korean Chemical Society
    • /
    • v.38 no.3
    • /
    • pp.221-223
    • /
    • 1994
  • We tried to apply the linear solvation energy comparison method to solute retention in normal phase liquid chromatography. Correlation coefficients of regression of lnk' collected in a fixed eluent against solute polarity indices have proven to be lower than those obtained from reversed phase liquid chromatography data. This event can be attributed to complexity of solute retention process in normal phase liquid chromatography. We concluded from the regression results that each specific polarity of the stationary phase is greater than that of the mobile phase and that the difference in each polarity between the stationary phase and the mobile phase decreases as the volume fraction(${\phi}$) of the more polar solvent in the mobile phase increases. Correlations of lnk' of a single solute against solvent polarity indices have proven to be meaningless owing to covariance among the solvent polarity indices. Instead, a good linear relationship between lnk' and solvent ${\pi}^*$ was observed, and its linearity is better than that between lnk' and ${\phi}$.

  • PDF