Developed Ability of Zero-phase Overcurrent Relay by Changed setting point value (설정치 변경에 의한 영상과전류계전기의 성능개선)

  • Kim, N.H.;Yoon, D.S.;Chang, S.I.;Choi, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.11a
    • /
    • pp.220-222
    • /
    • 1998
  • This paper presents a method, which develops an ability of Zero-phase Overcurrent Relay. Zero-phase current is very useful factor of Fault decision in Protect Relaying system. Actually, the setting-point value of Designed Relay, using Zero-phase current, is fixed. So in the case of deciding fault, Fixed setting-point value is not suitable for changing Load. and cause errors in Distributions system. For solving this problem, This paper proposes the Changed setting point value Algorithm, which can be adaptive for changing Distributions system using Zero-phase current r.m.s. indexes. The results of simulation under Load changing and High impedance fault show that proposed algorithm is useful for changing Distributions system and decreasing errors.

  • PDF

Frequency Synchronization of Three-Phase Grid-Connected Inverters Controlled as Current Supplies

  • Fu, Zhenbin;Feng, Zhihua;Chen, Xi;Zheng, Xinxin;Yin, Jing
    • Journal of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.1347-1356
    • /
    • 2018
  • In a three-phase system, three-phase AC signals can be translated into two-phase DC signals through a coordinate transformation. Thus, the PI regulator can realize a zero steady-state error for the DC signals. In the control of a three-phase grid-connected inverter, the phase angle of grid is normally detected by a phase-locked loop (PLL) and takes part in a coordinate transformation. A novel control strategy for a three-phase grid-connected inverter with a frequency-locked loop (FLL) based on coordinate transformation is proposed in this paper. The inverter is controlled as a current supply. The grid angle, which takes part in the coordinate transformation, is replaced by a periodic linear changing angle from $-{\pi}$ to ${\pi}$. The changing angle has the same frequency but a different phase than the grid angle. The frequency of the changing angle tracks the grid frequency by the negative feedback of the reactive power, which forms a FLL. The control strategy applies to non-ideal grids and it is a lot simpler than the control strategies with a PLL that are applied to non-ideal grids. The structure of the FLL is established. The principle and advantages of the proposed control strategy are discussed. The theoretical analysis is confirmed by experimental results.

Performance Comparison of Phase Detectors for the Synchronization Analysis of Electroencephalographic Signal (뇌파신호의 동기해석을 위한 위상검출기의 성능비교)

  • Kim, HyeJin;Lee, JeeEun;Yoo, Sun K.
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.277-284
    • /
    • 2013
  • The analysis of phase synchronization characteristics from EEG signals is important for the understanding of information processing functionality in the brain network. In this paper, wavelet transformation(WT), Hilbert tansformation (HT), complex demodulation (CD) methods having time localization characteristics were applied to real evoked potential data and noise added simulation data with center frequencies corresponding to EEG bands for the estimation performance analysis of phase offset, phase changing point, and interband crosstalk. The WT is the best both in ${\delta}$, ${\theta}$, and ${\alpha}$ band signal decomposition, and in analyzing phase synchronization performance. The CD can be efficiently used in changing point detection under tolerant noise condition because of its abrupt performance degradation over noise endurance level. From experimental observations, the WT is the most suitable in phase synchronization application of EEG signal, and the CD can be affordable in restricted application such as changing point detection for higher bands than ${\delta}$. Particularly, WT and CD can be used to detect the changing instant of brain function by indirectly estimating the phase changing point.

Multiple current source inverter using tap conversion (탶변환 방식을 이용한 다중 전류원 인버어터에 관한 연구)

  • Yu, Chul-Ro;Han, Woo-Yong;Gu, Deog-Soo;Park, Hyun-Chul
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.507-509
    • /
    • 1989
  • In multiple current source inverter, generally, transformer connection method and direct connection method in output side have been used. But these methods have faults such as the increment of the number of inverter and the need of the transformer for changing phase in order to get above 12 phase. In this system, we obtained the output currents of 24 phase by adding 2taps in 12 phase inverter. Therefore, this system has such characteristics as the miniaturization of devices and the simplicity of control signal by controlling two inverters and two SCRs for changing taps.

  • PDF

Spontaneous Direction-Changing or Reversing Positional Nystagmus without Changing Head Position during Head-Roll/Head-Hanging Maneuvers: Biphasic Positional Nystagmus

  • Yetiser, Sertac
    • Journal of Audiology & Otology
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2021
  • Background and Objectives: Conflicting mechanisms have been reported about spontaneous reversal of positional nystagmus during head-roll maneuver in patients with benign paroxysmal positional vertigo (BPPV). The objective of this study is to review the reports about the characteristics and possible mechanisms of reversing positional nystagmus and to present seven new cases. Subjects and Methods: Seven cases (5 males, 2 females; 4 left-sided, 3 right-sided) were recruited among 732 patients with BPPV seen outpatient clinic between 2009 and 2019. Diagnosis of lateral canal canalolithiasis was confirmed when transient geotropic nystagmus was documented during head-roll test. Reversing positional nystagmus was analyzed in each case and clinical characteristics of the patients were documented. Results: The age of patients was ranging between 30 to 64 years (46.44±10.91). Duration of symptoms was short (21.34±19.74). Six of them had a story of head trauma. Initial latency was short. First, intense geotropic nystagmus was observed following provocative head-roll position on the affected side. There was short "silent phase". Then, a longer second-phase of reversed nystagmus was noted. Total duration of nystagmus was 78.40±6.82 seconds. Maximal slow phase velocity was 24.05±6.34 deg/sec. All patients were cured with barbeque maneuver. Conclusions: Ipsilateral reversing positional nystagmus during head-roll maneuver is due to lateral canal canalolithiasis. Mechanism is likely to be due to endolymphatic double flow. Bilateral cases may be due to simultaneous co-existence of canalolithiasis and cupulolithiasis. Longer recording of nystagmus is recommended not to miss the cases with spontaneous direction-changing positional nystagmus.

Spontaneous Direction-Changing or Reversing Positional Nystagmus without Changing Head Position during Head-Roll/Head-Hanging Maneuvers: Biphasic Positional Nystagmus

  • Yetiser, Sertac
    • Korean Journal of Audiology
    • /
    • v.25 no.1
    • /
    • pp.43-48
    • /
    • 2021
  • Background and Objectives: Conflicting mechanisms have been reported about spontaneous reversal of positional nystagmus during head-roll maneuver in patients with benign paroxysmal positional vertigo (BPPV). The objective of this study is to review the reports about the characteristics and possible mechanisms of reversing positional nystagmus and to present seven new cases. Subjects and Methods: Seven cases (5 males, 2 females; 4 left-sided, 3 right-sided) were recruited among 732 patients with BPPV seen outpatient clinic between 2009 and 2019. Diagnosis of lateral canal canalolithiasis was confirmed when transient geotropic nystagmus was documented during head-roll test. Reversing positional nystagmus was analyzed in each case and clinical characteristics of the patients were documented. Results: The age of patients was ranging between 30 to 64 years (46.44±10.91). Duration of symptoms was short (21.34±19.74). Six of them had a story of head trauma. Initial latency was short. First, intense geotropic nystagmus was observed following provocative head-roll position on the affected side. There was short "silent phase". Then, a longer second-phase of reversed nystagmus was noted. Total duration of nystagmus was 78.40±6.82 seconds. Maximal slow phase velocity was 24.05±6.34 deg/sec. All patients were cured with barbeque maneuver. Conclusions: Ipsilateral reversing positional nystagmus during head-roll maneuver is due to lateral canal canalolithiasis. Mechanism is likely to be due to endolymphatic double flow. Bilateral cases may be due to simultaneous co-existence of canalolithiasis and cupulolithiasis. Longer recording of nystagmus is recommended not to miss the cases with spontaneous direction-changing positional nystagmus.

A study on improvement of convergent measurement performance of color display tube using photo sensors (포토 센서를 이용한 브라운관의 컨버젼스 측정 성능 향상에 관한 연구)

  • ;;Zeungnam Bien
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.3
    • /
    • pp.93-101
    • /
    • 1998
  • In Integrated Tube Components(ITC) process in themanufacturing of color display tube, we describe the necessity of the convergence measurement method using photo sensors. Compared with methods using 1D or 2D cameras, its characteristics is to use of moving image patterns and fixed sensors. This measurement method is formulated as the measurement problem of the phase difference in phase changing periodic signals. The convergence measurement system using photo sensors, for the good performance, must have a small standard deviation for the repetitive measurement in the same condition and a fast measurement time for thecovergence change. By above two conditions, we proposed the real time measurement algorithm of the pahse difference using fundametal and harmonic in phase changing periodic signals. And, the proposed algorithm is applied to the convergence measurement system.

  • PDF

A Design Study of Phase Changing Heat Exchanger for Environmental Control System (환경조절장치용 상변화열교환기의 개념설계연구)

  • Yoo, Young-June;Oh, Chang-Mook;Lee, Hyung-Joo;Min, Seong-Ki
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2010.11a
    • /
    • pp.628-635
    • /
    • 2010
  • Properties of bleed air that is air source of ECS(Environmental Control System) can be rapidly changed with airplane engine operating conditions during flight. Therefore, ECS can be operated at a high performance or not during flight. So, high performance ACM has to be developed in order to flight safely. A adaptability of phase changing heat exchanger was esteemed at ACM type ECS in this study. As a result of this study, it is found that ECS outlet temperature can be controlled in a certain range with the phase changing phenomenon.

  • PDF

Short Circuit Tests of the Three-Phase DC Reactor Type Fault Current Limiter in Changing of Turns Ratio of Transformers (변압기 권선비의 변화에 따른 3상 DC 리액터형태 한류기의 단락실험)

  • Lee, Eung-Ro;Lee, Chan-Ju;Lee, Seung-Je;Go, Tae-Guk;Hyeon, Ok-Bae
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.267-272
    • /
    • 2002
  • This Paper deals with the short circuit tests of the three-Phase DC reactor type fault current limiter (FCL) in changing of turns ratio of transformers. The experiment of this paper is a preliminary step to develop the FCL's faculties for an application to high voltage transmission line. So, superconducting coil was made of Nb-Ti, low temperature superconductor, and the ratings of the power system of experimental circuit are 400V/7A class. A three-phase DC reactor type FCL consists of three transformers, six diodes, one superconducting coil and one cryostat. The important point of experimental analysis is transient period, the operating lagging time of circuit breaker. As the results of the experiment, the values are referred to the limitation rate about 77% and 90% when the turns ratio of transformer was 1:1 and 2:1 respectively.

An Improved Method of Fault Indication Information Using Filtering Algorithm (배전자동화 중앙장치에서 필터링 알고리즘을 통한 고장표시 오류 개선방법)

  • Seo, Jung-Soo;Kim, Hyung-Seung;Lim, Sung-Il;Choi, Myeon-Song;Lee, Seung-Jae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.10
    • /
    • pp.1418-1425
    • /
    • 2015
  • In this paper, an filtering method of FI(Fault Indication) information generated by FRTU(Feeder Remote Terminal Unit)s is proposed for the present DAS(Distribution Automation System). In order to find fault area, correct FI information should be generated. But when a single line-to-ground fault occurs, FI information is generated in downside of the fault in some circumstance because existing FI algorithm considers only magnitude. These wrong FI information can be removed by changing existing algorithm. An improved algorithm considers both the direction of zero-sequence current and the phase of three-phase current&voltage. But many FRTUs are distributed in DAS and Changing the algorithm all of FRTU will spend a lot of time and cost. On the other hand, an filtering algorithm proposed in this paper can substitute for it. The filtering algorithm also considers both the direction of zero-sequence current and the phase of three-phase current&voltage. In case study, the proposed method has been shown the reasonability in filtering the fault indication information.