• 제목/요약/키워드: Phase Calibration

검색결과 502건 처리시간 0.034초

Adaptive Calibration Method in Multiport Amplifier for K-Band Payload Applications

  • Moon, Seong-Mo;Shin, Dong-Hwan;Lee, Hong-Yul;Uhm, Man-Seok;Yom, In-Bok;Lee, Moon-Que
    • ETRI Journal
    • /
    • 제35권4호
    • /
    • pp.718-721
    • /
    • 2013
  • This letter proposes a novel calibration method for a multiport amplifier (MPA) to achieve optimum port-to-port isolation by correcting both the amplitude and phase of the calibration signals. The proposed architecture allows for the detection of the phase error and amplitude error in each RF signal path simultaneously and can enhance the calibrated resolution by controlling the analog phase shifters and attenuators. The designed $2{\times}2$ and $4{\times}4$ MPAs show isolation characteristics of 30 dB and 27 dB over a frequency range of 19.5 GHz to 22.5 GHz, respectively.

3상 전력을 기반으로 한 시스템 해석 컴퓨터 (Computer Based Three Phase Power Analysing System)

  • 위제;박영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.675-676
    • /
    • 2008
  • The computer based three phase power analysing system has been developed as a traveling standard for onsite power calibration. The system is utilized with digital-to-analog converts which were synchronized each other. Using digital signal processing technique the software has been developed to calculate power parameters. The calibration system is fully traceable to national standard system and, accuracy allows the calibration of industrial power measurement systems.

  • PDF

256 능동위상배열 기반 연직바람 관측장비의 송수신 채널 크기 및 위상 보정 방법 연구 (Study on TRX Channel Amplitude and Phase Calibration Method for a Radar Wind Profiler Based on 256 Active Phased Array)

  • 정우재;이종철
    • 한국ITS학회 논문지
    • /
    • 제21권5호
    • /
    • pp.162-170
    • /
    • 2022
  • 본 논문에서는 256 능동위상배열 기반의 연직바람 관측장비(RWP)의 송수신 채널의 크기 및 위상을 보정하는 방법등이 논의된다. 별도의 모듈 추가 없이 송수신 전단기 및 송수신 전환기에 커플러 및 스위치를 사용하여 송신 및 수신 보정 경로를 확보하였고, Gain 및 Phase Detector를 사용하여 256 송수신 채널의 크기 및 위상을 독립적으로 보정하였다. 보정된 256 능동위상배열 안테나는 근접전계 시험을 통해 5개의 빔 (연직, 동, 서, 남, 북)의 빔폭 및 사이드 로브가 시뮬레이션 계산 값과 일치함을 확인하였다. 제안된 보정방법은 실외 환경에서 운용되는 능동위상배열 기반의 시스템에 용이하게 적용이 가능하다.

Single-Phase Energy Metering Chip with Built-in Calibration Function

  • Lee, Youn-Sung;Seo, Jeongwook;Wee, Jungwook;Kang, Mingoo;Kim, Dong Ku
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권8호
    • /
    • pp.3103-3120
    • /
    • 2015
  • This paper presents a single-phase energy metering chip with built-in calibration function to measure electric power quantities. The entire chip consists of an analog front end, a filter block, a computation engine, a calibration engine, and an external interface block. The key design issues are how to reduce the implementation costs of the computation engine from repeatedly used arithmetic operations and how to simplify calibration procedure and reduce calibration time. The proposed energy metering chip simplifies the computation engine using time-division multiplexed arithmetic units. It also provides a simple and fast calibration scheme by using integrated digital calibration functionality. The chip is fabricated with 0.18-μm six-layer metal CMOS process and housed in a 32-pin quad-flat no-leads (QFN) package. It operates at a clock speed of 4096 kHz and consumes 9.84 mW in 3.3 V supply.

Improved Calibration for the Analysis of Emerging Contaminants in Wastewater Using Ultra High Performance Liquid Chromatography and Time-of-Flight Mass Spectrometry

  • Pellinen, Jukka;Lepisto, Riikka-Juulia;Savolainen, Santeri
    • Mass Spectrometry Letters
    • /
    • 제9권3호
    • /
    • pp.77-80
    • /
    • 2018
  • The focus of this paper is to present techniques to overcome certain difficulties in quantitative analysis with a time-of-flight mass spectrometer (TOF-MS). The method is based on conventional solid-phase extraction, followed by reversed-phase ultra high performance liquid chromatography of the extract, and mass spectrometric analysis. The target compounds included atenolol, atrazine, caffeine, carbamazepine, diclofenac, estrone, ibuprofen, naproxen, simazine, sucralose, sulfamethoxazole, and triclosan. The matrix effects caused by high concentrations of organic compounds in wastewater are especially significant in electrospray ionization mass spectroscopy. Internal-standard calibration with isotopically labeled standards corrects the results for many matrix effects, but some peculiarities were observed. The problems encountered in quantitation of carbamazepine and triclosan, due to nonlinear calibration were solved by changing the internal standard and using a narrower mass window. With simazine, the use of a quadratic calibration curve was the best solution.

LCOS 마이크로디스플레이 구동용 보정회로 설계 (Design of Calibration Circuit for LCOS Microdisplay)

  • 이연성;위정욱;한충우;송남철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2022년도 추계학술대회
    • /
    • pp.469-471
    • /
    • 2022
  • 본 논문에서는 아날로그 구동 방식의 4K UHD LCOS 패널을 구동하기 위해 디지털 픽셀을 아날로그 픽셀로 변환하는 과정에서 발생되는 이득 오차, DC 옵셋, 샘플링 클럭의 위상 오차를 보정하기 위한 보정회로의 구현 방법을 기술한다. 제안된 보정회로는 이득 및 DC 옵셋 보정 회로와 샘플링 클럭 위상 조정 회로로 구성되며, FPGA와 비디오 앰프를 이용하여 구현하였다.

  • PDF

노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법 (A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image)

  • 고국원;김민영
    • 한국산학기술학회논문지
    • /
    • 제10권5호
    • /
    • pp.909-916
    • /
    • 2009
  • 본 연구는 위상천이 영사식 모아레 측정기의 기준 위상 측정단계에서 기준 위상의 검출 정확도를 높이기 위한 방안으로, 일반적인 N-bucket 방법이 아닌, 줄무늬 패턴 투사 영상의 직접적인 영상처리를 기반으로, 노이즈가 포함된 영상으로부터 기준 위상을 자동으로 검출하고 보정하는 방법을 다룬다. 일반적으로 기준위상을 정확히 구하기 위해서는 상대적으로 노이즈가 원천적으로 적은 고정밀도의 교정 시편과 이에 맞는 세분화된 교정방법이 필요하다. 하지만, 고가의 시편 제작비용 절감과 고정도 교정을 위한 교정시간의 단축을 위해, 상대적으로 일반 정밀도등급의 제작된 시편으로부터 획득된 영상을 이용하여, 효율적인 기준위상 교정 방법을 제안한다. 투사된 평행 라인 띠가 시편에서 반사되어 카메라로 입력되는 영상으로부터, 영상처리 라인마스크를 이용하여 격자 라인들의 중심점을 정밀하게 추출하고, 각 라인들에서 추출된 샘플링점 기반의 최소자승법을 이용하여, 라인 특징치인 기울기와 절편을 추출함으로써 실제 관측되는 격자 라인의 중심선을 획득하였으며, 획득된 중심선들을 이용하여 N-bucket 알고리즘에 적용할 수 있도록 위상을 추출한 후, 기준위상을 자동으로 생성하였다. 본 연구를 통하여 고가의 시편 제작 없이 빠르게 자동으로 기준위상을 추출할 수 있었다.

PMP 형상 측정법의 위상보정에 관한 연구 (A study on the phase calibration of the phase measuring profilometry)

  • 이연태;강영준;황용선
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 추계학술대회 논문집
    • /
    • pp.421-424
    • /
    • 2002
  • The 3-D measurement using a sinusoidal grating pattern projection is very attractive because of its high measuring speed and high sensitivity. When a sinusoidal amplitude grating was projected on an object, the surface-height distribution of the object is translated into a phase distribution of the deformed grating image. The phase-acquisition algorithms are so sufficiently simple that high-resolution phase maps using a CCD camera can be generated in a short time. The PMP technique is discussed, and the analysis of the systematic errors, the calibration procedure designed to determined the optimal setting of the measurement parameters is illustrated. Results of measurements and calibrations on the measurement plane objects are described.

  • PDF