• Title/Summary/Keyword: Phase Calibration

Search Result 502, Processing Time 0.022 seconds

Comparison on Usefulness of Sampling Methods of Indoles in Airs from Swine Facility by Tenax-TA and SPME

  • Yu, Mee-Seon;Lee, Jae-Chun;Yang, Sung-Bong;Kim, Doo-Hwan;Cho, Sung-Back;Whang, Ok-Wha
    • Journal of Environmental Science International
    • /
    • v.22 no.12
    • /
    • pp.1539-1549
    • /
    • 2013
  • The purpose of this study is to compare the sampling methods for monitoring indoles (phenol, p-cresol, indole and skatole) in airs of swine facility. As the collecting methods of indoles in air, Tenax-TA adsorption tube and solid phase microextraction (SPME) were examined. For the preparation of calibration curves of indoles concentrated in Tenax-TA, the standard indoles solutions were spiked in each of Tenax-TA tubes and thermally desorbed (ATD) into a gas chromatograph combined with mass detector (GC/MS). And for the preparation of calibration curves by SPME, indoles in the standard gaseous solution prepared by evaporating the aqueous solution that contained indoles into a polyester sampling bag were extracted with SPME fiber and subsequently analyzed by the GC/MS. Two sampling methods were evaluated for extracting indoles present in swine building environments. Results indicated that the SPME method using Polydimethylsiloxane/ Divinylbenzene (PDMS/DVB) fiber was more effective than Tenax-TA method in extracting indoles. The gas chromatographic analysis showed that the linearities of calibration curves and detection limits were useful for detection of indoles in swine airs. The field tests also showed that considerably different levels of indoles were present in various parts of the swine building.

A Study on Measurement Technique of Insulation Resistance for Non-interrupting Inspection Using Non-contact Voltage Phase Detection Technology (비접촉 전압위상 검출 기술을 이용한 무정전 절연저항 측정 방법에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bae;Choi, Dong-Hwan;Kim, Yong-Hyeok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.8
    • /
    • pp.1106-1112
    • /
    • 2018
  • In this paper, measurement techniques are presented to test the performance of insulation without interruption if it is difficult to measure insulation resistance. Especially, non-contact voltage phase detection techniques have been developed that can be applied in environments where it is difficult to find voltage measurement locations such as component receptors. The performance verification of the non-interrupting insulation resistance measuring devices has been tested against existing products using standard calibration equipment and test jigs. The validation confirmed performance within 2 % for direct contact type and within 10 % for non-contact type. In addition, the procedure to make continuous insulation test using the equipment was proposed.

Surpassing Tradeoffs by Separation: Examples in Transmission Line Resonators, Phase-Locked Loops, and Analog-to-Digital Converters

  • Sun, Nan;Andress, William F.;Woo, Kyoung-Ho;Ham, Don-Hee
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.8 no.3
    • /
    • pp.210-220
    • /
    • 2008
  • We review three examples (an on-chip transmission line resonator [1], a phase-locked loop [2], and an analog-to-digital converter [3]) of design tradeoffs which can in fact be circumvented; the key in each case is that the parameters that seem to trade off with each other are actually separated in time or space. This paper is an attempt to present these designs in such a way that this common approach can hopefully be applied to other circuits. We note reader that this paper is not a new contribution, but a review in which we highlight the common theme from our published works [1-3]. We published a similar paper [4], which, however, used only two examples from [1] and [2]. With the newly added content from [3] in the list of our examples, the present paper offers an expanded scope.

Establishment of National Standard System for 20.000 A Current Transformer (20,000 A 전류변성기 국가표준 시스템 구축)

  • Jung, Jae-Kap;Lee, Sang-Hwa;Kang, Jean-Hong;Kim, Myung-Soo;Kim, Yoon-Hyoung;Han, Sang-Gil;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.1
    • /
    • pp.6-13
    • /
    • 2008
  • National standard system for calibrating current transformer(CT) up to primary current of 20,000A have been established. The system consists of 20,000 A AC high current source, CT comparator, standard CT, CT under test and CT burden. An AC high current is applied tn the primary windings of both the standard CT and the CT under test, and then the CT comparator measures the ratio error and the phase displacement by comparing the secondary currents of the two transformers. As a validity check for 20,000 A CT calibration system, the comparison with the two national standard institutes(NMIs) has been performed using same CTs. The comparison results of the CTs are consistent with those measured at two NMIs within 0.004 % for ratio error and 0.1 min for phase displacement in the primary current ranges of Ip = 10 - 20,000 A with a secondary current of Is = 5 A.

Synthesis of $SrTiO_3$ from the Mixtures of $SrCO_3$ and $TiO_2$ ($SrCO_3$$TiO_2$를 사용한 $SrTiO_3$의 합성반응에 관한 연구)

  • 이종권;이병하
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.1
    • /
    • pp.43-48
    • /
    • 1983
  • The formation of strontium titanate from several molar $SrCO_3$ and $TiO_2$ mixtures was studied in air and $CO_2$ gas Mixtures of $SrCO_3$ and $TiO_2$ were heated in air at 400-$600^{\circ}C$ DTA-TG was used to obtain thermal histories of simples heated in air and $CO_2$ gas. X-ray diffraction analysis was used to determine both the phase composition and the amounts of each phase present. The phase relationship of various compounds $SrTiO_3$, $Sr_2TiO_4$, $Sr_2Ti_3O_7$ and $Sr_4Ti_3O_{10}$ formed by the sintering in each composition was shown by the calibration curves. High temperature X-ray analysis was used to determine both the formation process and deformation process of each products. Small amount of SrTiO3 is formed first at the surface af contact SrTiO3 reacts with $SrCO_3$ to form Sr2TiO4 this is affected on the $CO_2$ pressure.

  • PDF

A 40 MHz to 280 MHz 32-phase CMOS 0.11-${\mu}m$ Delay-Locked Loop (40MHz ~ 280MHz의 동작 주파수와 32개의 위상을 가지는 CMOS 0.11-${\mu}m$ 지연 고정 루프)

  • Lee, Kwang-Hun;Jang, Young-Chan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.05a
    • /
    • pp.95-98
    • /
    • 2012
  • This paper describes a multiphase delay-locked loop (DLL) that generates a 32-phase output clock over the operating frequency range of 40 MHz to 280 MHz. The matrix-based delay line is used for high resolution of 1-bit delay. A calibration scheme, which improves the linearity of a delay line, is achieved by calibrating the nonlinearity of the input stage of the matrix. The multi-phase DLL is fabricated by using 0.11-${\mu}m$ CMOS process with a 1.2 V supply. At the operating frequency of 125MHz, the measurement results shows that the DNL is less than +0.51/-0.12 LSB, and the measured peak-to-peak jitter of the multi-phase DLL is 30 ps with input peak-to-peak jitter of 12.9 ps. The area and power consumption of the implemented DLL are $480{\times}550{\mu}m^2$ and 9.6 mW at the supply voltage of 1.2 V, respectively.

  • PDF

A Class-C type Wideband Current-Reuse VCO With 2-Step Auto Amplitude Calibration(AAC) Loop (2 단계 자동 진폭 캘리브레이션 기법을 적용한 넓은 튜닝 범위를 갖는 클래스-C 타입 전류 재사용 전압제어발진기 설계)

  • Kim, Dongyoung;Choi, Jinwook;Lee, Dongsoo;Lee, Kang-Yoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.11
    • /
    • pp.94-100
    • /
    • 2014
  • In this paper, a design of low power Current-Reuse Voltage Controlled Oscillator (VCO) which has wide tuning range about 1.95 GHz ~ 3.15 GHz is presented. Class-C type is applied to improve phase noise and 2-Step Auto Amplitude Calibration (AAC) is used for minimizing the imbalance of differential VCO output voltage which is main issue of Current-Reuse VCO. The mismatch of differential VCO output voltage is presented about 1.5mV ~ 4.5mV. This mismatch is within 0.6 % compared with VCO output voltage. Proposed Current-Reuse VCO is designed using CMOS $0.13{\mu}m$ process. Supply voltage is 1.2 V and current consumption is 2.6 mA at center frequency. The phase noise is -116.267 dBc/Hz at 2.3GHz VCO frequency at 1MHz offset. The layout size is $720{\times}580{\mu}m^2$.

Application of Polyurethane Foam Loaded with a Schiff Base Ligand for Determination of Trace Amounts of Copper in Water Samples by Flame Atomic Absorption Spectroscopy

  • Moftakhar, Mahdieh Koorehpazan;Yaftian, Mohammad Reza;Nahaei, Samaneh;Zamani, Abbas Ali
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.3
    • /
    • pp.283-288
    • /
    • 2014
  • A column solid phase extraction procedure based on modified polyurethane foam (PUF) by a newly synthesized Schiff base ionophore, named 2,2'-{iminobis[propane-3,1-diylnitrilo(1E)prop-1-yl-1-ylidene]}diphenol, was developed for preconcentration step of trace amounts determination of copper ions in water samples by atomic absorption flame spectroscopy. The influence of parameters on the adsorption process such as sample pH, amount of modified PUF packed in the column, type and volume of stripping reagent and its flow rate were investigated and optimized. Under optimum experimental conditions, the calibration graph was linear in a relatively wide range ($0.005-210{\mu}g/ml$) with a limit of detection $0.002{\mu}g/ml$ of copper. The proposed method allows achieving to a concentration factor of >133. The capacity of a column (1.6 cm i.d.) packed by 6 g of PUF modified by 12 mg of the Schiff base was found to be $247.7({\pm}2.1){\mu}g$ of copper. It was found that the adsorption process was highly selective towards copper ions with respect to some associated metal ions. The presented procedure was successfully applied for determination of copper in some water samples.

Theory of a Current-Type Electromagnetic Flowmeter for Two-Phase Flow and Numerical Computation of the 3D Virtual Potential Distributions for Annular Flow (2상류용 전류형식 전자기유량계 이론 및 환상류에서의 3차원 가상포텐셜 분포의 수치적 계산)

  • Oh, Byung-Do;Kim, Moo-Hwan;Ahn, Yeh-Chan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.27 no.6
    • /
    • pp.714-725
    • /
    • 2003
  • The theory of the current-type electromagnetic flowmeter for a high temporal resolution was developed for two-phase flow measurements. To predict the output of the current-type flowmeter, the three-dimensional virtual potential distribution C and the newly introduced flow pattern coefficient f were derived and computed. The output of flowmeter depends on the liquid conductivity (sensitive to temperature) and flow configurations of the two-phase flow with the sinusoidal excitation over 100 Hz. The flow pattern coefficient was specially devised to separate the dependency on the flow configuration of the two-phase flow from that on the liquid conductivity which can be expressed with the calibration of single-phase flow. Using the finite difference method, the three-dimensional virtual potential distributions were computed for the electrode of finite size. By taking derivative of the virtual potential, the weight functions were evaluated and compared with existing analytic series solution for the point-electrode. There was a reasonable correspondence between the present and existing results. In addition, the flow pattern coefficients were evaluated for annular flows with various film thicknesses, and compared with the experimental results by the impedance spectroscopy. The numerical results agreed well with the experimental data.

Analysis of Distribution of Propylene oxide in Nonionic Surfactant and Fatty alcohol by Reversed Phase High Performance Liquid Chromatography (역상 액체 크로마토그래피에 의한 비이온 계면활성제의 Propylene oxide 분포 및 Fatty alcohol의 분석)

  • Lee, Yong-Hwa;Bak, Hong-Soon;Choi, Kyu-Yeol;Lee, Jae-Duk;Ahn, Ho-Jeong
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.315-319
    • /
    • 1997
  • In this study, the optimum analytical conditions for determination of distribution of propylene oxide in a nonionic surfactant and separation of fatty alcohols were investigated by Reversed Phase High Performance Liquid Chromatography. To analyse the distribution of propylene oxide (PO) and carbon chain length of a fatty alcohol, we derivatized samples for the purpose of using a UV detector. Also, we studied the influences of columns and mobile phase composition to obtain the optimum separation conditions. In our experiment, Waters Symmetry $C_8(3.9{\times}150mm)$ column was used. And the optimum condition were obtained by gradient elution with methanol and water as the mobile phase. In the plot of log k' vs composition of water in the binary phase, the linerality was very good. We ploted the calibration curve to conform the quality of fatty alcohol, a good linerality was obtained.

  • PDF