• Title/Summary/Keyword: Perpendicular fixation

Search Result 14, Processing Time 0.018 seconds

HISTOLOGICAL CHANGES IN THE ELONGATED BONE AFFECTED BY OSTEODISTRACTION OF THE MANDIBLE IN THE DOG (성견 하악골 절단 후 기계적 골 견인에 의해 형성된 골 신장부에 대한 시기별 조직학적 변화)

  • Baek, Sun-Ho;Ahn, Byoung-Keun;Park, Young-Ju;Park, Hee-Geon;Park, Jun-Woo;Rhee, Gun-Joo;Lee, Yong-Chan;Cho, Byoung-Ouck
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.404-416
    • /
    • 2001
  • Purpose : Traditionally, the treatement of choice has been a bone grafting procedure to increase the length of bone in case of actual length discrepancy. But, bone grafting procedure has many disadvantages, for example, graft resorption, donor site morbidity, and so on. So, many trials have been performed to avert the use of autogenous bone graft via introducing new materials or methods. And, one of those trials has been realized by the development of a technique inducing bone lengthening by osteotomy (or corticotomy) and slow gradual distraction of the osteotomized segments. This new technique of bone lengthening dates back to the early 20th century. But, the majority of information concerning the biology of new bone formation during bone lengthening and technical details of the procedure were produced by extensive clinical and experimental studies performed by Ilizarov, a Russian surgeon. According to Ilizarov, with adequate blood supply, preservation of periosteum, rigid fixation of the osteotomized segments, and proper rate and rhythm of distraction, intramembranous bone rapidly develops within the distraction gap in the limb lengthening procedure. In the limb lengthening, many orthopedic surgeons try to observe the biologic and clinical principles recommended by Ilizarov. In the oral and maxillofacial region, however, not a few studies must be performed to apply this surgical technique in the clinical cases. Besides, the mechanism of bone formation in the distraction gap is not clear, yet. The purpose of this experiment was to scrutinize serially the histological changes in the elongated bone affected by osteodistraction of the mandibular body in an adult canine model. In addition, it was performed to confirm the presence of specific region(s) which was important in the bone formation in the gap through the observation of the expression pattern of osteocalcin and osteonectin with the immunohistochemical examination. Materials and Methods : The experimental and control specimens were obtained from seven adult male mongrel dogs weighing over 20kg. The distractors were custom-made linear extraoral devices and bicortical fixation screws were 2.3mm in diameter, 50mm in total length, 15mm in screw length. The distractors were devised to produce a linear gap of 0.75mm between two bony segments every $360^{\circ}$ turn of the rotation rod of the device. The mandibular body of the right side of each animal was corticotomized perpendicular to the occlusal plane and then two bony segments were separated completely by careful manipulation of the segments with bone forceps. The left side of each animal was left intact. This side was served as control. At sixth day after osteotomy and fixation of the segments were performed, distraction of the segments was commenced with a rate of 1.1mm/day and a rhythm of two/day for ensuing 7 days. The animals were euthanized at the 16th. 29th, and 44th day after the osteotomy. The bony specimens were decalcified, embedded in paraffin, sectioned $5{\mu}m$ thick and stained with H&E. The prepared specimens were examined under the light microscope. And, immunohistochemical examinations using anti-osteocalcin antibody (OC1, Biodesign, USA) and anti-osteonectin antibody (Haematologic Technologies Inc., Essex, VT) to locate the expressions of osteocalcin and osteonectin, respectively, were performed. Results : 1. New bone was observed already at the 16th. day after osteotomy. This suggests that new bone formation in osteodistraction was commenced at an early stage of the regenerative process. But, radiologically and microscopically, bony union was not completed in the distraction gap at the 44th. day after osteotomy. Therefore, rigid fixation must be maintained between the bony fragments till the complete bony union is confirmed clinically rather than one month or so after the completion of distraction.

  • PDF

Open Reduction of Mandibular Condyle Fracture Via Preauricular Approach (전이개 접근을 이용한 하악 과두 골절의 정복)

  • Kim, Bum-Joon;Cha, Yong-Hoon;Lim, Jae-Hyung;Park, Kwang-Ho;Huh, Jong-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.32 no.6
    • /
    • pp.521-528
    • /
    • 2010
  • Purpose: Anatomical reduction of the fractured condylar process is an important prerequisite for re-establishing function. The authors reported about effectiveness of transoral approach for mandibular subcondyle fracture using trochar device in cases that the fracture line is below the reference line, the perpendicular line of the longitudinal axis of condylar process passing the lowest point of sigmoid notch. As a serial study, we report the open reduction via preauricular approach for mandibular condyle fracture, in cases that the fracture line is above the reference line. Patients and Methods: Sixteen condylar fractures of 15 adult patients were divided two groups and treated by open reduction via preauricular approach (8 cases) or by closed reduction (8 cases). The degree of maximal mouth opening, occlusion, anatomical reduction, condylar resorption and complications were assessed and evaluated for the two groups. Results: The open reduction of condyle via preauricular approach leads to good results without permanent complications. Anatomical reduction of open reduction group and maximal mouth opening range of the closed reduction group is significantly better than the other group. No significant differences were found in the condylar resorption and the occlusion. Conclusion: The preauricular approach was useful to reduce and fix the condylar fragment, in cases that the fracture line is above the reference line.

Estimating Fatigue Life of APD Electronic Equipment for Activation of a Spaceborne X-band 2-axis Antenna (2축 짐벌식 X-band 안테나 구동용 전장품 APD 제어보드의 피로수명 평가)

  • Jeon, Young-Hyeon;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.1
    • /
    • pp.1-7
    • /
    • 2017
  • While a satellite is carried into orbit by a launch vehicle, it is exposed to the severe launch environment with random vibrations and shock. Accordingly, these vibration sources affect electronic equipment, particularly the printed circuit board (PCB) in the satellite. When the launch load impacts the PCB, it causes negative behavior. This causes perpendicular bending around the boundary of fixation points that finally leads to the failure of solder joints, lead wires, and PCB cracks. To overcome these issues, the electronic equipment design must meet reliability requirements. In this paper, Steinberg's method is used to derive allowable and maximum deflection to verify design from a life perspective concerning the control board of the Antenna Pointing Driver (APD) mounted on KOMPSAT-3.

Healing of the bone around pure titanium implants without primary bone contact (초기 골 접촉이 없는 순수 티타늄 임프란트 주위 골의 치유반응)

  • Ahn, Jae-Hyun;Kim, Heung-Joong;Park, Joo-Cheol;Han, Kyung-Yoon;Kim, Byung-Ock
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.1
    • /
    • pp.233-249
    • /
    • 1999
  • Primary fixation is one of the most important factor in establishing adequate osseointegration between implant and bone. To evaluate the initial healing response of bone around implants without primary bone contact, this study was designed to create considerable space between implant and bone in 5 mongrel dogs, about 1-year old. After 3 holes of 6.0mm in diameter were prepared at the femur neck of the dogs, commercially pure titanium thread type implants(STERI-$OSS^{(R)}$), 8mm in length and 3.8mm, 5.0mm and 6.0mm in diameter, were inserted. Implants were supported by only nonresorbable membrane($Teflon^{(R)}$), and the penetration of upper soft tissue into the gap was inhibited by it. The each implant was positioned in the center of the drilled hole. 9 implants with different diameters were inserted in 3 dogs for histologic observation, and 12 were inserted in 2 dogs for mobility test and removal torque test.Fluorescent dyes were injected in order of Doxycycline, Alizarin Red S, and Calcein at intervals of 2 weeks. At 4-, 8-, and 12-week after placement, 3 dogs were sacrificed for histologic observation, and at 8- and 12-week after placement, 2 dogs were sacrificed for mobility test using $Periotest^{(R)}$ (Simens AG, Bensheim, Germany) and torque test using Autograph AGS-1000D $series^{(R)}$(Japan). The result were as follows: 1. The wider the gap between bone and implant was, the less bone maturity was, and the later osseointegration was occurred. Trabecular direction of new bone around implant was changed from parallel to perpendicular to the implant, and the gap was filled with new bone, over time. 2. There was a decreasing tendency over time in the mobility of all implants, but the wider gap between bone and implant was, the smaller decrease of the mobility was. 3. There was a increasing tendency over time in the removal torque gauge of all implants, and the wider gap was, the smaller increase of the removal torque gauge was. The results suggest that osseointegration in case of implant without primary bone contact may be obtained by guided bone regeneration technique with prolonged healing period, but the time of second surgery should be considered carefully.

  • PDF