• 제목/요약/키워드: Peroneal perforator flap

검색결과 20건 처리시간 0.032초

비골동맥 천공지 피판의 임상적 적용 (Clinical Applications of Peroneal Perforator Flap)

  • 오상하;오현배;이승렬;강낙헌
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.187-192
    • /
    • 2006
  • The perforator flaps are based on cutaneous vessels which are originated from a main pedicle and penetrate fascia or muscle to reach the skin. The lateral lower leg is one of the most suitable areas for harvesting perforator flaps because a number of perforator vessels exist. The authors applied peroneal perforator flaps in nine patients. Five flaps were reverse island flaps based on peroneal artery and septocutaneous perforator, and four flaps were free flap based on musculocutaneous perforator only. The recipient site was the posterior ankle in three patients, posterior heel in three patients, lateral malleolus, anterolateral ankle, and foot dorsum in one patient each. The flap size ranged from 5 to 12cm long, from 3 to 5cm wide, and the primary closure of the donor site was possible in most cases. All flaps, except for the flap in two patients in the reverse island flap series, survived completely. The peroneal perforator flap is a very thin, pliable flap with minimal donor site morbidity and is suitable for the reconstruction of small and medium sized superficial skin defects. Also, this flap may be considered as an alternative to radial forearm flap or other perforator flaps.

Peroneal Flap: Clinical Application and Cadaveric Study

  • Ha, Yooseok;Yeo, Kwan Koo;Piao, Yibo;Oh, Sang-Ha
    • Archives of Plastic Surgery
    • /
    • 제44권2호
    • /
    • pp.136-143
    • /
    • 2017
  • Background The goal of this study was to investigate the anatomy of the peroneal artery and its perforators, and to report the clinical results of reconstruction with peroneal artery perforator flaps. Methods The authors dissected 4 cadaver legs and investigated the distribution, course, origin, number, type, and length of the perforators. Peroneal artery perforator flap surgery was performed on 29 patients. Results We identified 19 perforators in 4 legs. The mean number of perforators was 4.8 per leg, and the mean length was 4.8 cm. Five perforators were found proximally, 9 medially, and 5 distally. We found 12 true septocutaneous perforators and 7 musculocutaneous perforators. Four emerged from the posterior tibia artery, and 15 were from the peroneal artery. The peroneal artery perforator flap was used in 29 patients. Retrograde island peroneal flaps were used in 8 cases, anterograde island peroneal flaps in 5 cases, and free peroneal flaps in 16 cases. The mean age was 59.9 years, and the defect size ranged from $2.0cm{\times}4.5cm$ to $8.0cm{\times}8.0cm$. All the flaps survived. Five flaps developed partial skin necrosis. In 2 cases, a split-thickness skin graft was performed, and the other 3 cases were treated without any additional procedures. Conclusions The peroneal artery perforator flap is a good alternative for the reconstruction of soft tissue defects, with a constant and reliable vascular pedicle, thin and pliable skin, and the possibility of creating a composite tissue flap.

비골 동맥 천공지 피판 (Peroneal Perforator Flap)

  • 정덕환;황준성
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.29-35
    • /
    • 2004
  • Materials and Methods: Total number of peroneal perforator flap is 14 cases, which 10 cases were man, 4 cases were woman. The range of age was 12 years old minimally and until 63 years old. The trauma was most common etiology, which was like traffic accidents, 9 cases. We confirmed tibialis anterior artery patency by doppler flow meter, angiography as preoperative evaluation. Results: 1. The success rate was 91%, that in 14 cases, 13 cases were succeded. 2. To obtain successful result of peroneal flap, one must have the anatomic concept for vascular pattern, 8 cases were between peroneus muscle and soleus muscle branch type but, 3 cases were through soleus muscle branch type, so we treated these cases by using soleus muscle including peroneal perforating branch not to injury perforating artery directly. 3. The pedicle size was between minimally $2{\times}2.5cm$ and maximally $6.5{\times}8.5cm$ so we could treat large recipient site. 4. The pedicle length was between minimally 3.2 cm and maximally 11.5cm, average 7.5 cm. 5. The diameter of perforating artery was estimated by inspection, that was about 0.2-0.5 cm Conclusion: The peroneal perforating artery flap has merits that we can approach in avascular zone and has wide movable range from foot to distal femur and little donor site mobidity and can harvest osteocutaneous flap. The weak point was the irregular anatomy of nutrient artery and not to contain sensory nerve.

  • PDF

돌발적 손상에 의해 천공지가 없는 신경-정맥피판의 생존 (Survival of Neuro-Venous Flap without Perforator due to Accidental Division of Perforator)

  • 변제연;최환준
    • Archives of Hand and Microsurgery
    • /
    • 제23권4호
    • /
    • pp.290-295
    • /
    • 2018
  • 저자는 종아리동맥의 천공지를 이용하여 발목을 재건하려는 중 천공지가 절단되어 비복신경과 복재정맥만 보존된 피판의 성공적인 생존을 경험하였다. 24세 아시안 남성에서 전신마취 하에 종아리 동맥 천공지, 복재정맥, 비복신경을 확인하고 보존하고 피판을 회전시키는 과정에서 종아리 동맥 천공지의 절단이 발생하였다. 천공지의 손상에도 불구하고 피판의 경계에서 혈행이 확인되었다. 수술 후 환자는 특이 합병증 없이 회복되었고, 미용적인 결과와 기능적인 결과에서 모두 만족스러웠다. 몇몇 연구에서 비복신경과 동반하는 혈행을 보고하고 있다. 결과적으로, 종아리 동맥의 천공지 없이 비복신경과 동반하는 동맥의 혈류만으로도 충분한 혈액 공급이 가능하였다. 따라서 어느 환경에서나 그리고 어느 부위에서나 피판의 천공지뿐만 아니라 신경-혈관을 보존하는 것이 중요하다.

비골 동맥 천공지 피판의 혈관 해부학 (Vascular Anatomy of Peroneal Perforator Flap)

  • 정덕환;한정수;황준성
    • Archives of Reconstructive Microsurgery
    • /
    • 제13권1호
    • /
    • pp.36-42
    • /
    • 2004
  • Materials and Methods: We studied 50 cases of peroneal perforating branch about branching pattern, course, length of vascular pedicle, and perforating level of the perforating cutaneous branches from Oct. 1985 to November 2003 by doppler flow meter and intraoperative findings. Results: 1) The perforating cutaneous branches were classified into four types, the Straight Branch (27cases), the Proximal Oblique Branch (11cases), the Branch from Muscular Artery (10cases), the Distal Oblique Branch(2 cases) respectively. The most common patten was Straight Branch, that was 54%. 2) There were 3 pathways of these branches, the most common one passed between the Soleus and Peroneus muscles(34 cases, 68%) 3) The length of vascular pedicle in Buoy Flap was variable from from 3 cm to 15 cm, but 32 cases(64%) were distributed between 5 cm and 6 cm. 4) The perforating level of branches were 5.9 cm in average from fibular neck to subcutaneous perforator artery 5) Peroneal Buoy Flap in possible to reconstruct both seperated bone and skin defect in some distance by One-Stage Operation and we can harvest maximal $8{\times}16cm$ sized flap in one perforating artery. If we include more two perforating artery, we get more wide flap which can cover large defect.

  • PDF

Reconstruction of Ankle and Heel Defects with Peroneal Artery Perforator-Based Pedicled Flaps

  • Ahn, Deok Ki;Lew, Dae Hyun;Roh, Tai Suk;Lee, Won Jai
    • Archives of Plastic Surgery
    • /
    • 제42권5호
    • /
    • pp.619-625
    • /
    • 2015
  • Background The reconstruction of ankle and heel defects remains a significant problem for plastic surgeons. The following options exist for reconstructing such defects: local random flaps, reverse flow island flaps, and free flaps. However, each of these methods has certain drawbacks. Peroneal artery perforators have many advantages; in particular, they are predictable and reliable for ankle and heel reconstructions. In this study, we report our clinical experience with peroneal artery perforator-based pedicled flaps in ankle and heel reconstructions. Methods From July 2005 to October 2012, 12 patients underwent the reconstruction of soft tissue defects in the ankle and heel using a peroneal artery perforator-based pedicled flap. These 12 cases were classified according to the anatomical area involved. The cause of the wound, comorbidities, flap size, operative results, and complications were analyzed through retrospective chart review. Results The mean age of the patients was 52.4 years. The size of the flaps ranged from $5{\times}4$ to $20{\times}8cm^2$. The defects were classified into two groups based on whether they occurred in the Achilles tendon (n=9) or heel pad (n=3). In all 12 patients, complete flap survival was achieved without significant complications; however, two patients experienced minor wound dehiscence. Nevertheless, these wounds healed in response to subsequent debridement and conservative management. No patient had any functional deficits of the lower extremities. Conclusions Peroneal artery perforator-based pedicled flaps were found to be a useful option for the reconstruction of soft tissue defects of the ankle and heel.

비골 동맥 천공지 기저 프로펠러 피판술을 이용한 족관절 주위 연부조직 결손의 재건술: 4예 보고 (Peroneal Artery Perforator-Based Propeller Flaps for Reconstruction of Soft Tissue Defect around the Ankle Joint: A Report of Four Cases)

  • 조병기;박지강;박경진;정수리
    • 대한족부족관절학회지
    • /
    • 제18권4호
    • /
    • pp.222-226
    • /
    • 2014
  • Four patients with soft tissue defects around the ankle joint were covered with peroneal artery perforator-based propeller flaps. Using color Doppler sonography, the flap was designed by considering the location of the perforator and soft tissue defects. The procedure was then performed by rotating the flap by $180^{\circ}$. Additional skin graft was required in a patient due to partial necrosis, and delayed wound repair was performed in another patient with poor blood circulation at the distal part of the flap. The remaining patients did not have any complications and results were considered excellent. Good outcomes were eventually obtained for all patients.

두경부 재건에 있어서 천공지 피판의 다양한 유용성 (Various Utility of Perforator Flaps in Head and Neck Reconstruction)

  • 김정태;이철용;김순진
    • Archives of Plastic Surgery
    • /
    • 제32권3호
    • /
    • pp.271-280
    • /
    • 2005
  • There are various types of flap in head and neck reconstruction. We chose the appropriate flap considering the indication and patient's condition. In case of conventional flaps, its type is decided according to the reconstruction site. In other words, the types of considerable flaps are limited in a way. But, perforator flaps can reduce donor limitation and harvest flaps depending on the condition of the recipient. Therefore, the flap is very useful for the head and neck reconstruction needed for 2-dimensional or 3-dimensional reconstruction. We report the 29 cases of perforator-based flap including 8 cases of latissimus dorsi perforator free flap, 5 thoracodorsal perforator free flap, 4 anterolateral thigh perforator free flap, 3 peroneal osteocutaneous perforator free flap and 9 submental perforator island flap for the head and neck reconstruction. Free flaps include 2 cases of chimeric pattern, 7 controlled resurfacing pattern, 4 3-D pattern, 3 dermoadiposal pattern, 1 folded pattern and 3 osteocutaneous pattern. The flaps were successfully used for the head and neck reconstruction. But one patient died during a follow up period because of the recurrence of tumor. Various perforator flaps(island/free pattern) can be highly competitive to the conventional flaps in the head and neck reconstruction, considering a thin character for resurfacing, more flexible and versatile option, variable composition, long pedicle with donor structures saved, and less prominent donor morbidity.

고압 전기화상에 의한 수부 손상 시 비골동맥 천공지 유리피판술을 이용한 재건 (Reconstruction of Hand Using Peroneal Perforator Free Flap in High-Voltage Electrical Burn Patients)

  • 김동훈;유중석;임준규;이동락
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.67-72
    • /
    • 2008
  • Purpose: The hand is frequently affected area in high voltage electrical burn injury as an input or output sites. Electrical burn affecting the hand may produce full thickness necrosis of the skin and damage deep structures beneath the eschar, affecting the tendon, nerve, vessel, even bone which result in serious dysfunction of the hand. As promising methods for the reconstruction of the hand defects in electrical burn patients, we have used the peroneal perforator free flaps. Methods: From March 2005 to June 2006, we applied peroneal perforator free flap to five patients with high tension electrical burn in the hand. Vascular pedicle ranged from 4cm to 5cm and flap size was from $4{\times}2.5cm$ to $7{\times}4cm$. Donor site was closed primarily.Results: All flaps survived completely. There was no need to sacrifice any main artery in the lower leg, and there was minimal morbidity at donor site. During the follow-ups, we got satisfactory results both in hand function and in aesthetic aspects.Conclusion: The peroneal perforator flap is a very thin, pliable flap with minimal donor site morbidity and is suitable for the reconstruction of small and medium sized wound defect, especially hand with electrical burn injury.

고압전기화상 환자에서 손바닥에 비골동맥천공지유리피판수술과 등의 이물질제거수술: 증례 보고 (Peroneal Artery Perforator Free Flap on the Palm and Removal of Back Foreign Body in High Voltage Electrical Burn Patient: A Case Report)

  • 정승원;이승제
    • 대한화상학회지
    • /
    • 제22권2호
    • /
    • pp.58-65
    • /
    • 2019
  • Wound caused by high-tension electrical burns is difficult to manage because the wound is deep and complex. The wound is progressively necrotic due to microvascular injury resulting in deep tissue exposure. So, coverage of the wound at the entry point and the exit point is cumbersome, often requiring flap coverage. We experienced a case of one patient for peroneal artery perforator free flap coverage on the palm of the right hand of the entry point of electrical burn. The left foot wound of electrical exit point was covered by full thickness skin graft. Also a small wound was on the left side of the lower back was the exit point of electrical burn. The lower back wound was healed and recurred repeatedly after burn. On postburn day 6 month, through the radiologic exam, metal shadow was identified in the left gluteus muscle forming chronic sinus. We explored the wound of sinus and a foreign body was identified in the sac as multi braid wires thin as hair. According to the patient's past history, we suspected that the back wound was caused by electrical burn injury through the wires.