• Title/Summary/Keyword: Permittivity Measurement

Search Result 116, Processing Time 0.025 seconds

Measurement on the permittivity and propagation velocity of used insulation oil at UHF Band using time domain reflectometry (TDR을 이용한 극초단파 대역에서 사용 절연유의 유전율과 전파속도 측정)

  • Goo, Sun-Geun;Ju, Hyoung-Jun;Park, Ki-Jun;Han, Ki-Seon;Yoon, Jin-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2011-2014
    • /
    • 2008
  • We measured the permittivity and electromagnetic wave propagation velocity of used insulation oil with wide frequency range including ultra-high frequency by time domain reflectometry. The permittivity or propagation velocity is essential for locating discharge faults of oil filled power transformer. We derived 2.21 as a permittivity and $2.03{\times}10^8 m/s$ as a velocity from the measurement of pulse travelling time along a coaxial line filled with used insulation oil or air. The permittivity measurement system we designed shows high measurement accuracy and the convenience for field use.

A Measurement of Electromagnetic Property of Illite found in Young-dong Area (영동산 일라이트의 전자기적 특성 측정)

  • Kim, Jin-Chul;Lee, Won-Hui;Koo,K.W.;Hur, Jung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.267-270
    • /
    • 2000
  • This paper describes measurement of relative permittivity of illite found in young-dong area. A measurement of relative permittivity of illite used to cylindrical cavity resonators with moveable cap. A concentric dielectric-rod inserted cylindrical cavity resonator and an exact field representation of travelling wave mode are introduced for measurement of relative permittivity. The exact electromagnetic fields in cylindrical cavity with concentric dielectric rod is analysed. A relative permittivity of dielectric in cavity is calculated by analyzing the characteristic equation. The characteristic equation is solved by using the ContourPlot graph of Mathematica. We know that the field representation of travelling mode is exact. As a result, relative permittivity of dielectric materials were 7.820 at sample-1 and 7.894 at sample-2.

  • PDF

Measurement of Electromagnetic Properties of Concrete for Nondestructive Testing (비파괴 시험을 위한 콘크리트의 전자기적 특성의 측정)

  • 임홍철;정성훈
    • Journal of the Korea Concrete Institute
    • /
    • v.12 no.3
    • /
    • pp.115-123
    • /
    • 2000
  • Characterizing the electromagnetic properties of concrete is essential to the enhancement of accuracy and reliability in nondestructive testing of concrete structures using electromagnetic techniques. To establish a data base for the properties of concrete, a measurement technique has been developed and a set of data has been obtained for the frequency range of 1~6 GHz. As moisture content is one of major contributing factors to determine permittivity of dielectric material, moisture content is varied during the measurement. An application of a measurement system which consists of open-ended coaxial probe and automatic network analyzer to concrete and mortar specimens is studied. For this, calibration techniques, size of specimens, and number of measurements necessary to obtain reliable data are investigated. From the measured data, it is shown that moisture content plays an important role to determine the permittivity of specimens. As the moisture content increases. The permittivity of specimens show tendency to approach the permittivity of water.

Measurement Of The Engine Oil Relative Dielectric Constant With Respect To Capacitive Prove Dimension (정전용량 프로브 크기에 대한 엔진오일 상대 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.4
    • /
    • pp.209-212
    • /
    • 2011
  • The capacitive application(prove) can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents that we designed the analysis system of engine oil permittivity to know the relation between the engine oil deterioration and the prove dimension. Each of the dimension of capacitive prove is changed and then electric capacity is measured by LCR {Inductance(L), Capacitance (C), and Resistance (R)} meter. The engine oil permittivity has extracted in the prove measurement. As the additional research, this paper suggest the best of the prove dimension for the permittivity measurement.

Measurement of Electromagnetic Properties of Mortar for Nondestructive Testing (비파괴 실험을 위한 모르타르의 전자기적 특성 측정)

  • 정성훈;임홍철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10b
    • /
    • pp.779-784
    • /
    • 1998
  • The velocity and amplitude of microwaves are affected by the electromagnetic properties of a material through which the wave propagates. And the electromagnetic properties of a dielectric material such as concrete is represented by its permittivity. For the development of an accurate and reliable nondestructive testing (NDT) technique for concrete structures using microwave, it is necessary to have knowledge about the permittivity of concrete. In this paper, mortar specimens are used to serve as a basis for further measurement of concrete. The effect of water on the permittivity was studied using specimens with different water content. To assure the reliability of the measurement results, a statistical method was introduced.

  • PDF

Measurement of Complex Permittivity and Permeability for Powder-type Materials (분말재료의 복소 유전율 및 투자율 측정)

  • Park, Sang-Bok;Lee, Jang-Soo;Chong, Young-Seek;Cheon, Chang-Yul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.12
    • /
    • pp.2196-2201
    • /
    • 2007
  • Materials used at microwave are usually used as a dielectric with a manufacturing purpose of printed circuit boards, etc. Complex permittivity of them can be measured from attenuation constant or propagation constant of a transmission line using a microstrip line with bulk type. But as the technique recently which can manufacture to have complex permittivity and permeability demanded using nonferrous metals for powder-type grows up, we need sensors and methods which can measure characteristics of powder-type materials. So far measuring methods of permittivity and permeability with waveguide or coaxial cable are used but they have faults which have a complex measurement method and are difficult to simultaneously measure permittivity and permeability. In this paper, a simultaneous measuring method of permittivity and permeability with 2-port coaxial cable and a new proposed calculation. The proposed 2-port coaxial cable is designed to be easy to insert materials and to have a wideband. We measure permittivity and permeability of magnetic powder(Ni-Fe-Mo, Ni-Fe) which reveal its characteristic at $0.3{\sim}1.3GHz$ to identify the proposed sensor.

A Permittivity Measurement of Dielectric Slabs Using a Parallel Plate Waveguide (평행판 도파관을 이용한 유전율 측정 방법)

  • Cho, Gyo-Yeong;Park, Wee-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.2
    • /
    • pp.199-203
    • /
    • 2012
  • This paper introduces a simple new procedure approach to determine the permittivity of dielectric slabs. The method uses a parallel plate waveguide which supports a TEM mode. The presence of the dielectric slab placed at the bottom of the waveguide makes the speed of the TEM wave slower. The relationship between the change of the speed and the permittivity of the dielectric slab allows the determination of the permittivity. The relationship is analyzed electromagnetically, and the results of measurements are in good agreement with the analysis.

Microwave Rectangular Waveguide Measurement of the Engine Oil Dielectric Constant (초고주파 구형도파로를 이용한 엔진 오일의 유전율 측정)

  • Kim, Ki-Hoon;Kim, Young-Ju
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.156-161
    • /
    • 2011
  • The rectangular waveguide technique can be used to measure the complex permittivity of dielectric material of various thickness and cross section. This paper presents the analysis system of engine oil permittivity at which deterioration of engine oil is measured at the X-band(8-12.5 GHz). The middle of the rectangular waveguide has engine oil case and is connected with VNA(Vector Network Analyzer) for the measurement of the transmission$(S_{21})$ and reflection$(S_11)$ and then the permittivity is extracted. The deterioration of engine oil is proved by the comparison with both the extracted data and reference data. As the additional research, This paper suggest that an accurate permittivity is considered by not only the wave guide length but the air gap between oil case and the waveguide.

Simple Technique for Measurement of Complex Permittivity and Detection of Small Permittivity Change Using Partially Open Cavity

  • Park, Sangbok;Chung, Young-Seek;Cheon, Changyul
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.268-272
    • /
    • 2014
  • This letter presents a measurement methodology of the complex permittivity of liquid using a partially open cavity in narrow band. The partially open cavity (POC) can measure dielectric small changes caused by the temperature variation of the liquid inside the cavity as well. Using the resonance frequency and unloaded quality factor of the proposed POC, the complex permittivity is evaluated. The apertures on the walls of the cavity are designed to circulate the liquid inside to outside of the POC and located at the corner area of the cavity to minimize the disturbance of field distribution at the dominant mode. The results measured by the proposed POC were compared with those by the conventional open-ended probe and Cole-Cole equation. The POC showed better performance in measuring small dielectric constant changes than the open-ended probe.

A Fabrication of From and a Measurement of Relative Permittivity of Illite Found in Young-dong Area (영동산 일라이트의 성형 및 비유전율 측정)

  • Lee, Won-Hui;Choi, Hong-Ju;Koo, Kyung-Wan;hur, Jung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.5
    • /
    • pp.747-754
    • /
    • 2001
  • This paper describes measurement of relative permittivity of illite found in young-dong area. A measurement of relative permittivity of the illite was made using cylindrical cavity resonators with a moveable cap. A concentric dielectric-rod inserted the cylindrical cavity resonator and an exact field representation of non-decaying mode of the resonator are introduced for the measurement of relative permittivity. The exact electromagnetic fields in cylindrical cavity with a concentric dielectric rod is analysed. The relative permittivity of dielectric in the cavity is calculated by analyzing a characteristic equation. The characteristic equation is solved by using the ContourPlot graph of Mathematica. We know that the field representation of non-decaying mode is exact. As a result, the relative permittivity of dielectric materials was 7.820 for a sample with binder and 7.894 for a pure sample.

  • PDF