An Evaluation on Airborne Particulate and It's Components in the Welding Workplace for the Ship Construction Industry (조선업 용접작업장의 공기중 입자상물질 및 구성성분에 관한 연구)

  • Kang, Yong-Seon;Shin, Joong-Kyu;Lee, Song-Kwon;Yoon, Chung-Sik;Lim, Moo-Hyuk;Park, Man-Chul;Sim, Sang-Hyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.245-253
    • /
    • 2007
  • This research was performed to evaluate the airborne personal concentration of hazardouse materials during the process of ship construction and surveyed from May 23 to June 30, 2007 in Kyungnam West Distirct, Korea. The subject was 94 ship construction workers exposed to welding fume and respirable particulate. The airborne concentrations of those were compared to Permissible Exposure Limit(PEL) from the Ministry of Labor in Korea. The airborne concentration of 23 samples(48.9%) of welding fumes was less than $5mg/m^3$, that of 16 (34.0%) was between 5 and $10mg/m^3$, and that of 8 (17.0%) was greater than $10mg/m^3$. The airborne concentration of 27 (57.4%) of respirable particulate masses was less than $5mg/m^3$ and the othere are greater than $5mg/m^3$. The welding fumes were identified containing the heavy metasl such as Fe, Mn, Zn, Mg, Ca, and Cu. The respirable particulates has similiar tendency with welding fumes in the component of heavy metals. But the concentration of Ca, Cu, Cr, and Ni turned out to be higher in welding fumes. Twenty (42.6%) of the 47 samples of welding fumes were exceeded PEL. In the heavy metals in welding fumes, ten (21.3%) of the 47 samples of Mn were exceeded PEL. Based on the results, the higher airborne hazardous materials were still exposed to wokers in ship construction process. It is suggested that the appropriate engineering control be applied to minimize the exposed cocnetration in ship building processes.

Low Temperature Thermal Desorption (LTTD) Treatment of Contaminated Soil

  • Alistair Montgomery;Joo, Wan-Ho;Shin, Won-Sik
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.44-52
    • /
    • 2002
  • Low temperature thermal desorption (LTTD) has become one of the cornerstone technologies used for the treatment of contaminated soils and sediments in the United States. LTTD technology was first used in the mid-1980s for soil treatment on sites managed under the Comprehensive Environmental Respones, Compensation and Liability Act (CERCLA) or Superfund. Implementation was facilitated by CERCLA regulations that require only that spplicable regulations shall be met thus avoiding the need for protracted and expensive permit applications for thermal treatment equipment. The initial equipment designs used typically came from technology transfer sources. Asphalt manufacturing plants were converted to direct-fired LTTD systems, and conventional calciners were adapted for use as indirect-fired LTTD systems. Other innovative designs included hot sand recycle technology (initially developed for synfuels production from tar sand and oil shale), recycle sweep gas, travelling belts and batch-charged vacuum chambers, among others. These systems were used to treat soil contaminated with total petroleum hydrocarbons (TPH), polycyclic aromatic hydrocarbons (PAHs), pesticides, polychlorinated biphenyls (PCBs) and dioxin with varying degrees of success. Ultimately, performance and cost considerations established the suite of systems that are used for LTTD soil treatment applications today. This paper briefly reviews the develpoment of LTTD systems and summarizes the design, performance and cost characteristics of the equipment in use today. Designs reviewed include continuous feed direct-fired and indirect-fired equipment, batch feed systems and in-situ equipment. Performance is compared in terms of before-and-after contaminant levels in the soil and permissible emissions levels in the stack gas vented to the atmosphere. The review of air emissions standards includes a review of regulations in the U.S. and the European Union (EU). Key cost centers for the mobilization and operation of LTTD equipment are identified and compared for the different types of LTTD systems in use today. A work chart is provided for the selection of the optmum LTTD system for site-specific applications. LTTD technology continues to be a cornerstone technology for soil treatment in the U.S. and elsewhere. Examples of leading-edge LTTD technologies developed in the U.S. that are now being delivered locally in global projects are described.

  • PDF

Removal of Dissolved Iron in Groundwater by Injection-and-Pumping Technique: Application of Reactive Transport Modeling (주입-양수 기법을 활용한 지하수 내 용존 철 제거: 반응성용질이동모델링의 적용)

  • Choi, Byoung-Young;Yun, Seong-Taek;Kim, Kyoung-Ho;Koh, Yong-Kwon;Kim, Kang-Joo
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.6
    • /
    • pp.29-37
    • /
    • 2007
  • Shallow alluvial groundwaters in Korea of tell exceed the Korean Drinking Water Standard for dissolved iron (0.3 mg/L), which is one of the important water quality problems, especially in the use of bank infiltration technique. Using the reactive transport modeling, in this study we simulated the effectiveness of injection-and-pumping technique to remove dissolved iron in groundwater. The results of simulation showed that pumping of groundwater after injection of oxygenated water into aquifers is very effective to acquire the permissible water quality level. Groundwater withdrawal up to several times of irjected water in volume can be applicable to yield drinkable water. Potential problems such as clogging and permeability lowering due to in-situ precipitation of iron hydroxides may be insignificant. We also discuss on the mechanism and spatial extent of iron removal in aquifer.

Inservice Elementary Teachers' Perceptions of Teaching Skills and Educational Settings in Implementing a Problem Based Learning Approach (문제중심학습 교수 실행의 능력과 교육 환경에 대한 초등 교사들의 인식)

  • Choi, Hyun-Dong
    • Journal of the Korean earth science society
    • /
    • v.32 no.3
    • /
    • pp.334-345
    • /
    • 2011
  • The purpose of this study was to find out inservice teachers' teaching skills and relevant educational settings that could be applied to an instruction of problem-based learning (PBL). Participants have been instructed PBL teacher training programs and applied PBL into teaching and learning process. Three elementary teachers were selected to participate in the study, and data were collected with semi-structured interviews. The interviews of the teachers in relation to PBL were analyzed by two main topics: (1) the teachers' teaching skills required in PBL and (2) the educational settings in implementing PBL. The results are as follows: First, there is a difficulty involved in the implementation of PBL in that its preparation and teaching process are different from the traditional teaching methodology. However, as a helper who guides the students to self-directed learning in the free and permissible learning environment in which students are motivated to develop their potential effectively, the teachers are to invest their time consistently and to put their efforts into making an effective class in the entire process of PBL. Second, as a method to apply the problem-based learning to the education settings, the teachers must spread the awareness of PBL to fellow teachers, students, their parents and the administrators in education and form the community of the teachers. Most importantly, when the teachers apply PBL in the directly, from the joy of witnessing the changes in the students, they will choose to adopt PBL.

Development of Backfill Materials for Underground Power Cables Considering Thermal Effect (열특성 효과를 고려한 지중송전관로용 되메움재 개발)

  • Lee Dae-Soo;Kim Dae-Hong;Hong Sung-Yun
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.41-52
    • /
    • 2005
  • Because the allowable current loading of buried electrical transmission cables is frequently limited by the maximum permissible temperature of the cable or of the surrounding ground, there is a need fur cable backfill materials that can maintain a low thermal resistivity even while subjected to high temperatures for prolonged periods. Temperatures greater than $50^{\circ}C\;to\;60^{\circ}C$ may lead to breakdown of cable insulation and thermal runaway if the surrounding backfill material is unable to dissipate the heat as rapidly as it is generated. This paper describes the results of studies aimed at the development of backfill material to reduce the thermal resistivity. A large number of different additive materials were tested to determine their applicability as a substitute material. Tests were carried out for Dongrim river sand, a relatively uniform sand of very high thermal resistivity, $50^{\circ}C-cm/watt\;at\;10\%$ water content, $260^{\circ}C-cnuwatt$ when dry, and Jinsan granite screenings, and D-2 (sand and granite screenings mixture), E-1 (rubble and granite screenings mixture), a well-graded materials with low thermal resistivity, about $35^{\circ}C-cm/watt$ when at 10 percent water content, $100^{\circ}C-cm/watt$ when dry. Based on this research, 3 types of backfill materials were suggested for improved materials with low thermal resistivity and the applicability was assessed through field tests.

Analysis of Radioactivity in Coal Fly Ash (비산석탄회의 방사능 농도 분석)

  • Shin, Hyun-Sang;Lee, Myung-Ho;Kim, Mi-Kyung;Park, Doo-Wun;Lee, Chang-Woo;Rhee, Dong-Seok
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.187-193
    • /
    • 1999
  • The specific radioactivity concentrations in the coal fly ash obtained from heat producing stations in Korea were analyzed and its radiological hazard for reuse in construction purpose was evaluated. The concentrations of uranium isotopes in the real fly ash measured by TBP solvent extraction method and $\alpha$-spectrometer were found to be about 116.1 Bq $kg^{-1}$ for $^{238}U$, 5.01 Bq $kg^{-1}$ for $^{235}U$, and 121.2 Bq $kg^{-1}$ for $^{234}U$, respectively. The activity ratio of $^{234}U/^{238}U$, in the coal fly ash was in $1.04\;{\pm}\;0.03$, which is similar to that of uncontaminated Korean soil in natural conditions (1.14). The specific radioactivities of $^{226}Ra,\;^{232}Th,\;and\;^{40}K$ in the coal fly ash were also determined using $\gamma$-spectrometer with a HPGe detector The results showed that $^{226}Ra,\;^{232}Th,\;and\;^{40}K$ in the coal fly ash were in concentrations of $101.7{\sim}113.9$, $39.5{\sim}54.2\;and\;315.0{\sim}990.6$ Bq $kg^{-1}$, respectively. With the specific radioactivities obtained from $\gamma$-spectrometric measurements of the coal fly ash, its radiological hazard for reuse was evaluated. The result showed that the radioactivity of the coal fly ash was in permissible level.

  • PDF

Comparison of removal efficiency of diesel particulate filter with different measurement methods in a high-speed marine diesel engine (선박용 고속 디젤엔진에 적용한 디젤미립자 필터의 측정방법에 따른 입자상물질 저감효율 비교 연구)

  • Lee, Ik-Sung;Ko, Dong-Kyun;Moon, Gun-Feel;Nam, Youn-Woo;Kim, Shin-Han;Oh, Young-Taig
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.362-367
    • /
    • 2017
  • This study was conducted to compare the particulate removal efficiency of the developed diesel particulate filter using various measurement methods in a high-speed marine diesel engine. A four-stroke mechanical marine diesel engine is used for the test, which has a maximum output of 403 kW and is coupled to an AC dynamometer to control engine speed and load. The test was conducted based on four steady-state engine operating conditions of E3 engine test cycle for the measurement of PM and soot removal efficiency using partial dilution method considered as gravimetric method and filter smoke number method as light absorption method, respectively. As a result of the removal efficiency measurement according to the application of diesel particulate filter, particulate matter was reduced from 76% to 91% and the soot was reduced by more than 90% while meeting the permissible engine back pressure. From these results, the applicability of diesel particulate filter adopted in high-speed marine diesel engines could be confirmed. In addition, based on the result that the particulate removal efficiency varies with different measurement methods, the necessity of unification of these methods could be identified.

Indicating the Problem of Shielding Design and the Way of Estimating Radiation Leakage for CT Rooms located through Survey of Radiation Leakage : in the case of Busan and Gyung-nam Area (방사선 누설선량 조사를 통한 방어시설과 누설선량 평가방법에 대한 문제점 연구 : 부산, 경남 지역 CT실을 중심으로)

  • Yang, Won Seok;Choi, Jun-Hyeok;Shin, Woon-Jae;Min, Byung-In
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.768-777
    • /
    • 2013
  • The purpose of this study is to minimize radiation exposure to the workers and public members during CT examination. The objects are seven of the CT rooms in university hospitals and four of the CT rooms in clinics located in Busan and Gyung-nam area. The places of measurement for radiation leakage are 1) 3 m above the ground of shielding wall in the control room 2) particular space in the control room 3) worker's gate in the control room 4) the patient gate. Its values were calculated maximum leakage radiation per week(MLRW). As a result, the worker's gate of M clinic displayed the highest dose. When it was calculated by MLRW in classic method, it showed 1) $5.97{\pm}0.23$, 2) $0.50{\pm}0.02$, 3) $10.00{\pm}0.11$, 4) $2.37{\pm}0.47$ mR/week. All of them did not exceed limit for maximum permissible dose per week(MPDW). However, When MLRW of M clinic was calculated by empirical method, its value displayed $118.31{\pm}17.72$ mR/week.(MPDW>100 mR/week). Radiation leakage influenced in the control room(p<0.05). Therefore, The way of calculating MLRW must be developed and shielding wall in control room is designed 3 m above the ground for reducing dangerous of leakage radiation.

A Study on the Risk Assessment of Pesticide Residues of Agricultural to Ensure Military Food Safety (군 식품 안전성 확보를 위한 농산물 잔류농약 위해도 평가 연구)

  • Cho, Sung-Yong;Seo, Jun-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.137-143
    • /
    • 2020
  • To ensure safety of raw materials for military foods, hazard assessment and monitoring of residual pesticides was conducted on agricultural products consumed by 9 companies based in Gyeongin and Gangwon. Residual pesticides were analyzed for 142 different products, by applying the multi-species pesticide polycomponent analysis method. Of the 36 samples analyzed, residual pesticides were detected in 7 samples, representing a detection rate of 19.4%. One particular pesticide residue was detected in peanuts, green onions, and red pepper powder, and 20 types of pesticide residues were detected in red pepper powder used in combat foods. However, all residues were found to be below the permissible level. Moreover, the hazard assessment results for Cypermethrin, Tebuconazole and EPN showed the highest concentration among the residual pesticides detected. Since the estimated intake was less than 100% as compared to the ingestion limit, it was considered to be safe. I have suggested the edit as per my understanding. Please review for accuracy, and revise appropriately if required. This is the first pesticide Risk Assessment study encompassing military requirements. Considering the results, we expect further application research, including research on reducing hazardous materials.

Treatment of highly concentrated organic wastewater by high efficiency $UV/TiO_{2}$ photocatalytic system (고효율 자외선/광촉매 시스템을 이용만 고농도 유기성 폐수처리)

  • Kim, Jung-Kon;Jung, Hyo-Ki;Son, Joo-Young;Kim, Si-Wouk
    • KSBB Journal
    • /
    • v.23 no.1
    • /
    • pp.83-89
    • /
    • 2008
  • Food wastewater derived from the three-stage methane fermentation system developed in this lab contained high concentration organic substances. The organic wastewater should be treated through advanced wastewater treatment system to satisfy the "Permissible Pollutant Discharge Standard of Korea". In order to treat the organic wastewater efficiently, several optimum operation conditions of a modified $UV/TiO_{2}$ photocatalytic system have been investigated. In the first process, wastewater was pre-treated with $FeCl_{3}$. The optimum pH and coagulant concentration were 4.0 and 2000mg/L, respectively. Through this process, 52.6% of CODcr was removed. The second process was $UV-TiO_{2}$ photocatalytic reaction. The optimum operation conditions for the system were as follows: UV lamp wavelength, 254 nm; wastewater temperature, $40^{\circ}C$; pH 8.0; and air flow rate, 40L/min, respectively. Through the above two combined processes, 69.7% of T-N and 70.9% of CODcr contained in the wastewater were removed.