• 제목/요약/키워드: Permeation flux

검색결과 262건 처리시간 0.024초

Pd 계열 수소 분리막의 오염에 관한 연구 (A Study on Contamination of Hydrogen Permeable Pd- based Membranes)

  • 한종희;윤성필;남석우;임태훈;홍성안;김진수
    • 한국수소및신에너지학회논문집
    • /
    • 제14권1호
    • /
    • pp.17-23
    • /
    • 2003
  • $H_2$ permeation flux though a $100{\mu}m-thick$ Pd-Ru (6wt%) membrane was measured at various temperatures and pressures. The permeation flux followed the Sievert's law and thus the rate-limiting step of the hydrogen permeation was the bulk atomic diffusion step. The activation energy of the permeation flux was obtained at 17.9 kJ/mol and this value is consistent with those published previously. While no degradation of the permeation flux wasfound in the membrane exposed to the $O_2$ and $CO_2$ environments for 100 hours, the membrane exposed to $N_2$ environment for 100 hours showed the degradation in the $H_2$ permeation flux. The $H_2$ permeation was decreased as the exposure temperature to $N_2$, environment was increased. The $H_2$ permeation flux was fully recovered after the membrane was kept in the $H_2$ environment for certain time. The permeation flux degradation might be caused by the formation of metal nitride on the membrane surface.

휘발성 유기용매의 PDMS막에 대한 투과 플럭스와 수착특성 예측 (Prediction of Permeation Flux and Sorption Characteristics of Volatile Organic Solvents on PDMS Membrane)

  • 오한기;장화익;이광래
    • 멤브레인
    • /
    • 제10권1호
    • /
    • pp.30-38
    • /
    • 2000
  • 투과증발공정에서 polydimethylsiloxane(PDMS)막에 대한 용매의 수착특성과 투과 플럭스를 예측하는 방법을 제시하였다. 이 방법을 이용하여 chloroform, toluene, methoanol, n-butanol의 수착량과 투과 플럭스를 계산하였으며, 계산값과 실험값을 비교하였다. 팽윤을 촉진시키는 정용매(good solvent)인 toluene과 chloroform의 경우 계산된 수착량과 투과 플럭스는 실험값과 잘 일치하였다. 막의 밀도가 작을수록 수착량과 투과 플럭스는 증가하였다. 팽윤을 억제시키는 부용매(poor solvent)인 methanol, n-butanol의 경우는 실험값과 상당한 오차가 있었다. 따라서, 본 미케니즘에 의해 PDMS막에 대한 정용매의 수착량과 투과 플럭스는 실험에 의하지 않고도 이론적으로 예측할 수 있는 가능성을 보여주었다.

  • PDF

Si 입자를 함유한 반도체 세정폐수의 한외여과 특성[I] -Polysulfone 평판막에 의한 투과분리- (Permeation Behavior of Semiconductor Rinsing Wastewater Containing Si Particles in Ultrafiltration System -I. Permeation Characteristics of Polysulfone Flat Plate Membrane-)

  • 곽순철;이석기;전재홍;남석태;최호상
    • 멤브레인
    • /
    • 제8권2호
    • /
    • pp.102-108
    • /
    • 1998
  • 본 연구는 Si 미립자를 함유한 반도체 세정폐수의 평판막을 이용한 한외여과특성을 검토하였다. 평판막의 투과유속은 시간이 경과함에 따라 점차 감소하는 경향을 나타냈으며, 이현상은 막표면에 형성된 케익층의 증가 및 기공막힘에 기인한다. 흐름형태에 따른 투과유속은 cross flow가 dead-end flow의 약 1.4배 높았다. Si 미립자에 의한 막오염을 제거하는데는 역세법이 sweeping법 보다 우수하였다. 막오염으로 인한 투과유속의 감소는 질소가스로 역세척하여 초기투과유속의 약 85% 정도 회복되었다. 평판막을 이용한 cross flow 공정의 용질배제율은 약 90%였으며, 투과수증의 Si 미립자의 크기는 평균 70 nm였다.

  • PDF

표면개질된 폴리설폰 막에 대한 오일에멀젼의 수투와 플럭스 (Water Permeation Flux of Oil-Emulsion through Surface-Modified Polysulfone Membrane)

  • 송근호;김강희;조성헌;이광래
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.187-191
    • /
    • 2003
  • A hollow-fiber type polysulfone UF membrane was surface-coated with hydroxyethylmethacrylate (HEMA). The effect of various coating parameters on permeation flux, such as concentration ratio of AIBN/HEMA, solvent(water or methanol), and UV irradiation time, was investigated. The water permeation flux of oil-emulsion increased with concentration ratio of AIBN/HEMA, and increased with UV irradiation time. The flux of the membrane coated in solution using methanol as a solvent was greater than that of the membrane coated in solution using water as a solvent. The flux of both the coated and the uncoated membrane declined with the operation. The flux decline means that the membrane fouling by oil-emulsion occurs. However, the fouling of the coated membrane was much less than that of the uncoated membrane.

  • PDF

오일/물 에멀젼의 분리막 투과 특성 (Membrane Filtration Characteristics of Oil/Water Emulsions)

  • 김종표;임진수;유종훈;김재진;정건용;전명석;민병렬
    • 청정기술
    • /
    • 제5권2호
    • /
    • pp.69-78
    • /
    • 1999
  • 수용성 에멀젼형 절삭유의 한외여과 및 정밀여과 특성을 실험적으로 연구하였다. 한외여과막의 경우 오일/물 에멀젼의 투과 거동은 film model을 잘 따랐으나 정밀여과막인 ASYPOR막의 경우에는 이러한 거동을 벗어났다. 본 연구에서 사용된 모든 분리막의 경우 운전압력이 투과유속에는 큰 효과를 나타내지 않았다. 저압에서는 투과 초기 및 후기에서의 투과유속 감소율이 적은 반면 고압에서는 초기 투과유속은 매우 컸으나 투과유속의 감소율이 커서 후기에는 모두 비슷한 투과유속을 보여 주었다. 소수성이 큰 polycarbonate 정밀여과막의 경우 일반적인 경우와는 달리 운전시간이 증가함에 따라 투과유속이 증가하는 경향을 나타내었다. 교반하지 않은 cell에서의 임계투과압력은 150 ppm의 에멀젼 농도에서 약 $2.2kg_f/cm^2$이었으나 500 ppm의 농도에서는 $3.8kg_f/cm^2$ 압력에서 나타났다.

  • PDF

배출봉을 이용한 정밀여과용 관형 모듈의 투과특성 (Permeation Characteristics of the Microfiltration Tubular Module using the Discharged Rod)

  • 정건용;최정규
    • 멤브레인
    • /
    • 제19권4호
    • /
    • pp.285-290
    • /
    • 2009
  • 공칭 세공크기 $0.1\;{\mu}m$이고 내경이 5 mm인 정밀여과용 관형 분리막 내에 자체 설계한 배출봉을 삽입하여 막오염 감소효과에 따른 투과유속을 측정하였다. 원료용액으로는 에멀젼 상태의 dioctyl tinoxide (DOTO) 입자를 사용하였으며 0.5 wt%까지 농도를 변화시키면서 1.6 bar 이내에서 운전하였다. 배출봉의 효과는 매 실험마다 배출봉을 삽입한 경우와 사용하지 않은 경우의 투과유속을 비교하여 평가하였다. 배출봉을 사용할 경우 운전압력 1.6 bar에서 최대 20%의 투과유속이 향상되었다. 또한 DOTO 농도가 증가함에 따라서 배출봉에 의한 투과유속 향상효과는 크게 나타났으며 0.5 wt% 농도에서 43%까지 투과유속이 향상되었다.

Synthesis and Characterization of Copoly(amide-imide) Derivatives and Ultrafiltration Membrane Performances II - Permeation Properties of Copoly(amide-imide)s Ultrafiltration Membranes -

  • Jeon, Jong- young;Kim, Jong-hp
    • Korean Membrane Journal
    • /
    • 제3권1호
    • /
    • pp.24-31
    • /
    • 2001
  • Ultrafiltration membranes base on copoly(amide-imide) derivatives were prepared by the phase inversion method and the factors determining the permeation characteristics of membrane were investigated. The permeation behavior was observed by the relative ratio of permeate flux (J$\_$t/)/pure water flux (J$\_$o/). The characteristics through membrane were measured using aqueous solution of poly(ethyleneglycol) (MW 2.0$\times$10$\^$4/) over a temperature range of 10∼90$\^{C}$. With increasing the operating temperature, the relative ratio of flux became high. All the membranes had good chemical stability. Copoly(amide-imide) membranes having various Permeation properties could be obtained. Further, it was proved that the membrane performances could be determined from the preparation conditions as well as various operating conditions.

  • PDF

Hydrophilic Modification of Polypropylene Hollow Fiber Membrane by Dip Coating, UV Irradiation and Plasma Treatment

  • Kim Hyun-Il;Kim Jin Ho;Kim Sung Soo
    • Korean Membrane Journal
    • /
    • 제7권1호
    • /
    • pp.19-27
    • /
    • 2005
  • PP hollow fiber membrane was hydrophilized by EVOH dip coating followed by low temperature plasma treatment and UV irradiation. EVOH coating attained high water flux without any prewetting but its stability did not guaranteed at high water permeation rate. At high water permeation rate, water flux declined gradually due to swelling and delamination of the EVOH coating layer causing pore blocking effect. However, plasma treatment reduces the swelling, which suppress delamination of the EVOH coating layer from PP support result in relieving the flux decline. Also, UV irradiation helped the crosslinking of the EVOH coating layer to enhance the performance at low water permeation rate. FT-IR and ESCA analyses reveal that EVOH dip coating performed homogeneously through not only membrane surface but also matrix. Thermogram of EVOH film modified plasma treatment and W irradiation show that crosslinking density of EVOH layer increased. Chemical modification by plasma treatment and UV irradiation stabilized the hydrophilic coating layer to increase the critical flux of the submerged membrane.

담즙산염과의 고체분산체로부터 로바스타틴의 용출 및 십이지장 점막 투과 특성 (Dissolution and Duodenal Permeation Characteristics of Lovastatin from Bile Salt Solid Dispersions)

  • 전인구
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권2호
    • /
    • pp.97-106
    • /
    • 2009
  • Although lovastatin (LS) is widely used in the treatment of hypercholesterolemia, its bioavailability is known to be around 5%. This study was aimed to increase the solubility and dissolution-permeation rates of LS using solid dispersions (SDs) with bile salts. The solubilities of LS in water, aqueous bile salt solutions and non-aqueous vehicles were determined, and effects of bile salts on the cellulose or duodenal permeation of LS from SDs were evaluated using a horizontal permeation system. SDs were prepared at various ratios of LS to carriers, such as sodium deoxycholate (SDC), sodium glycocholate (SGC) and/or 2-hydroxypropyl-$\beta$-cyclodextrin (HPCD). The addition of bile salts (25 mM) in water increased markedly the solubility of LS by the micellar solubilization. Some non-aqueous vehicles were effective in solubilizing LS. From differential scanning calorimetric studies, it was found that the crystallinity of LS in SDs disappeared, indicating a formation of amorphous state. The SDs showed markedly enhanced dissolution compared with those of their physical mixtures (PMs) and drug alone. In the dissolution-permeation studies using a cellulose membrane, the donor and receptor solutions were maintained as a sink condition using pH 7.0 phosphate buffer containing 0.05% sodium lauryl sulfate (SLS). The flux of LS alone was nearly same as that of LS-SDC-HPCD (1:3:6) PM. However, the flux of LS-SDC-HPCD (1:3:6) SD slightly increased compared with drug alone and PM, suggesting that entrapment of LS in micelles does not significantly hinder the permeation across cellulose membrane. In the dissolution-duodenal permeation studies using a LS-HPCD-SDC (1:3:6) SD, the addition of various bile salts in donor solutions (25 mM) enhanced the permeation of LS markedly, and the fluxes were found to be $0.69{\pm}0.41$, $0.87{\pm}0.51$, $0.84{\pm}0.46$, $0.47{\pm}0.17$ and $0.68{\pm}0.32{\mu}g/cm^2/hr$ for sodium cholate (SC), SDC, SGC, sodium taurodeoxycholate (STDC) and sodium taurocholate (STC), respectively. The stepwise increase of donor SGC concentration increased the flux dose-dependently. From the relationship of donor SGC concentration and flux, the concentration of SGC initiating the permeation across the duodenal mucosa was calculated to be 11.1 mM, which is nearly same as the critical micelle concentration (CMC, 11.6 mM) of SGC. However, with no addition of bile salts and below CMC, the permeation was very limited and irratic, indicating that LS itself is very poor permeable. Higher protions of bile salt in SD such as LS-SDC or LS-SGC (1 : 49 and 1 : 69) showed highly promoted fluxes. In conclusion, SD systems with bile salts, which may form their micelles in intestinal fluids, might be a promising means for providing enhanced dissolution and intestinal permeation of practically insoluble and non-absorbable LS.

표면개질 알루미나막의 증기투과에 의한 알코올의 분리 (Separation of Alcohol/water Mixtures with Surface-modified Alumina Membrane in Vapor Permeation)

  • 이상인;오한기;이광래
    • 멤브레인
    • /
    • 제10권3호
    • /
    • pp.121-129
    • /
    • 2000
  • 높은 선택도와 투과도를 가진 분리막이 요구되지만 선택도가 높은 막은 투과도가 낮은 것이 일반적이다. 본 연구에서는 적절한 선택도를 유지하면서 높은 투과도를 갖는 분리막을 제조하기 위하여 다공성 알루미나막을 실란커플링제로 코팅하였다. 코팅된막에 대한 물의 접촉각은 90$^{\circ}$ 이상이었으며, 큰 소수성을 가짐을 의미하기 때문에 에탄올, 이소프로판올, 부탄을 수용액의 농축을 위한 증기투과실험을 수행하였다. 공급액중의 알코을 농도가 증가함에 따라 투과도가 증가하였으며, 이는 물에 비하여 코팅된 막에 대한 에탄올, 이소프로판올, 부탄올의 친화도가 크기 때문으로 판단된다. 코팅된 알루미나막의 투과도는 고분자막의 투과도에 비하여 20~1000배로 크게 나타났다.

  • PDF