• 제목/요약/키워드: Permeable

검색결과 1,039건 처리시간 0.032초

HYPER PERMEABLE VALUES AND ENERGETIC SETS IN BCK/BCI-ALGEBRAS

  • Jun, Young Bae;Kim, Seon Jeong;Song, Seok-Zun
    • 호남수학학술지
    • /
    • 제42권2호
    • /
    • pp.197-211
    • /
    • 2020
  • The notions of hyper permeable subalgebraic value and hyper permeable idealistic value are introduced, and related properties are investigated. Given a pair of two numbers in a unit interval, conditions for the pair to be hyper permeable subalgebraic value and hyper permeable idealistic value are discussed. Given hyperfuzzy structures, conditions for their level sets to be subalgebraic energetic, idealistic energetic, right stable and right vanished are considered. Relations between hyper permeable subalgebraic value and hyper permeable idealistic value are studied.

투수성해안구조물과 불규칙파의 상호작용에 관한 수치모델 연구 (A Study of the Numerical Model on the Interaction between Irregular Waves and Permeable Coastal Structures)

  • 김종욱;남인식;윤한삼;류청로
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.186-195
    • /
    • 2001
  • The purpose of this study is to develop the time-dependent, one-dimensional numerical model on the interaction between irregular waves and two-layer permeable coastal structures, by extending and modifying the numerical model PBREAK(Wurjanto and Kobayashi, 1992) which is applicable only to one-layer permeable coastal structures. The two-layer permeable coastal structure consists of two permeable underlayers with different permeable media resting on an impermeable slope and an armor layer covering the permeable underlayer. The numerical model of this study simulates the wave over rough permeable underlayer of arbitrary geometry as well as the waves inside two-permeable underlayers of arbitrary thickness for specified normally-incident irregular waves. The utility of the numerical model is founded from comparing with PBREAK and the four hydraulic model tests under irregular waves. The sensitivities of computed results according to typical parameters(porosity, stone diameter, horizontal width of the permeable underlayer) and major factors(friction factor of primary armor layer etc.) discussed.

  • PDF

단지내 차도용 투수성 포장의 물순환 효과분석 (An Analysis on the Hydrologic Cycle Effect of Rodway Permeable Pavement in Rasidential Site)

  • 이정민;현경학;여옥경
    • 한국물환경학회지
    • /
    • 제26권4호
    • /
    • pp.691-699
    • /
    • 2010
  • In recent years, increases in impervious areas with rapid urbanization and land use changes are causing numerous hydrologic cycle and environmental problems. Impermeable pavement have a various defect such as collection rainwater, decreasing of sliding resistance, and etc. In this study, the hydrologic cycle effect of permeable pavement were analyzed by the experiment and the numerical simulation. The numerical model used was a modified SWMM especially for considering the hydrologic cycle effect of permeable pavement. The parameters of modified SWMM were revised by the experimental results. Also, the effects of runoff quantity reduction are reviewed when permeable pavement is applied to Incheon Cheongna watershed. The hydrologic cycle analysis of Incheon Cheongna watershed, continuous simulations of urban runoff were performed. The analysis results of permeable pavement setup effect on runoff are follows: the surface runoff after permeable pavement setup decreases to 74.35% of the precipitation whereas the surface runoff before permeable pavement setup amounts to 81.38% of the precipitation; the infiltration after permeable pavement setup increases to 15.13% of the precipitation whereas the infiltration before permeable pavement setup amounts to 8.32% of the precipitation.

폴리머 모르터를 필터로 사용한 투수성 폴리머 콘크리트의 역학적 성질과 (A Study on the Mechanical Properties and Permeability of Permeable Polymer Concrete Covered with Polymer Mortar as a Filter)

  • 박응모;조영국;소양섭
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1998년도 봄 학술발표회 논문집(I)
    • /
    • pp.237-242
    • /
    • 1998
  • Covering mortar as a filter for permeable polymer concrete is necessary for good permeability from filtration continuously. Therefore, this paper is intended as an evaluation of the mechanical properties and permeability of permeable polymer concrete covered with polymer mortar as a filter. An optimum permeable polymer concrete is selected in various mix proportions, and three different polymer mortars were cast immediately following on the casting of the base permeable polymer concrete. And they are tested for compressive and flexural strengths, adhesion in tension, hardening shrinkage and permeability . From the test results, binder and filler contents in mix proportions had a great influence on the permeability of polymer concretes. The mechanical properties of permeable polymer concretes covered with polymer mortars using crushed stone are superior to other filters, and hardening shrinkage is the smallest in filters. It is apparent that adhesion between the base permeable polymer concrete and polymer mortar is affected by the degree of hardening shrinkage. From this study, proper mix proportions can be recommended in the consideration of properties of the permeable polymer concrete.

  • PDF

An Experimental Study of Permeable Concrete Pavement for Practical Use in the Field

  • Kim, Seong-Soo;Jung, Ho-Seop;Moon, Han-Young
    • International Journal of Concrete Structures and Materials
    • /
    • 제19권1E호
    • /
    • pp.17-23
    • /
    • 2007
  • In rainy weather, permeable concrete pavement has advantages such as good drainage, increased skid resistance, reduced splash and spray behind vehicles for improving the safety of driving vehicles as well as reduction of the traffic noise. It also contributes to improvement of traffic environment. In this study, the fundamental properties of permeable concrete in accordance with maximum size of aggregate, sand percentage and unit cement content were investigated for practical use of permeable concrete pavement. Although the permeability standard for typical permeable asphalt-concrete pavement is $1{\times}10^{-2}cm/sec$, the researchers determined that the coefficient of permeability of the permeable concrete should be set higher at $1{\times}10^{-1}cm/sec$. Then, the researchers measured the coefficient of permeability, strength, void ratio, and continuous void ratio of the permeable concrete while varying maximum size of the aggregate, sand percentage, unit cement content for detailed analysis. It was found that the void ratio, continuous void ratio, and flexural strength were about 15%, 12%, and 5.0MPa, respectively, when the permeability of the concrete was set at $1{\times}10^{-1}cm/sec$. Given that the maximum size of aggregate was $10{\sim}13mm$, we reached the conclusion that the best mix design for permeable concrete was $0{\sim}20%$ of sand percentage and $380kg/m^3$ of unit cement content.

침투 해저면 위의 투과잠제주변 파랑특성의 수치해석 (NUMERICAL ANALYSIS OF WAVE CHARACTERISTICS AROUND PERMEABLE SUBMERGED BREAKWATER ON THE POROUS SEABED)

  • 김남형;우수민
    • 한국전산유체공학회지
    • /
    • 제19권3호
    • /
    • pp.8-13
    • /
    • 2014
  • In this study, wave characteristics coming with oblique incident angle to permeable trapezoidal submerged breakwater on the porous seabed are calculated by using boundary element method. This numerical analysis, based on the wave pressure function, is analyzing the continuity in the analytical region including fluid and structure. From the comparison of the reflection coefficients and damping coefficient, the results of this study are in good agreement with the existing results. The peak values of reflection coefficient obtained by permeable trapezoidal submerged breakwater on the porous seabed are smaller than those of permeable trapezoidal submerged breakwater on the non-porous seabed. The velocity vector in front of permeable trapezoidal submerged breakwater on the porous seabed is smaller than that in front of permeable trapezoidal submerged breakwater on the non-porous seabed with out the energy loss.

PERMEABLE VALUES AND ENERGETIC SETS IN BCK/BCI-ALGEBRAS BASED ON FUZZY POINTS

  • Song, Seok Zun;Kim, Hee Sik;Roh, Eun Hwan;Jun, Young Bae
    • 호남수학학술지
    • /
    • 제41권3호
    • /
    • pp.581-593
    • /
    • 2019
  • The notions of (${\in}$, ${\in}{\vee}q$)-permeable S-value and (${\in}$, ${\in}{\vee}q$)-permeable I-value are introduced, and related properties are investigated. Relations among (${\in}$, ${\in}{\vee}q$)-fuzzy subalgebra, (${\in}$, ${\in}{\vee}q$)-fuzzy ideal, (strong) lower and (strong) upper level sets, (${\in}$, ${\in}{\vee}q$)-permeable S-value, (${\in}$, ${\in}{\vee}q$)-permeable I-value, S-energetic set, I-energetic set, right stable set and right vanished set are discussed.

Permeable FW-H 방법을 이용한 원형 실린더 주변의 난류유동소음해석 (Turbulent-Induced Noise around a Circular Cylinder using Permeable FW-H Method)

  • 최원석;홍석윤;송지훈;권현웅;정철민
    • 해양환경안전학회지
    • /
    • 제20권6호
    • /
    • pp.752-759
    • /
    • 2014
  • 난류유동에 의한 소음은 계산비용의 관점에서 음향 상사법을 이용하여 전산유체 기법과 결합해 다양한 해석모델이 연구되고 있다. FW-H 음향상사법을 이용한 유동소음해석의 연구가 활발히 이루어지고 있으나, 기존 문헌들의 결과에서는 계산비용의 관점에서 난류유동에 의한 소음성분을 생략하고 있다. 그러나, 최근의 연구에서 유동소음특성에 있어 난류소음의 중요성이 밝혀진바 있다. 본 논문에서는 RANS 난류모델과 투과성 경계면을 이용한 Permeable FW-H 음향상사법을 이용한 난류유동소음해석에 대해 연구하였다. 2D실린더에 대하여 직접적으로 변동압력을 추출하는 직접법과 난류성분을 고려하지 않은 FW-H 상사법, 또 난류소음의 성분을 포함하는 Permeable FW-H 방법의 경우를 비교하였다. Permeable FW-H 방법을 통해 일반적으로 적용되는 FW-H 방법에서 해석 불가능한 난류에 의한 소음의 영향을 기존의 FW-H 방법과 동일한 계산비용으로 예측할 수 있었고, 적절한 투과성 경계면 설정을 통해 높은 정확도의 해석이 가능했다. Permeable FW-H 방법을 통한 난류유동해석 절차를 확립하였으며, 그 유용성을 확인했다.

폐유리분말과 재생골재를 사용한 포장용 투수성 폴리머 콘크리트의 공학적 성질 (Engineering Properties of Permeable Polymer Concrete for Pavement using Powdered Waste Glass and Recycled Coarse Aggregate)

  • 성찬용;김태호
    • 한국농공학회논문집
    • /
    • 제53권6호
    • /
    • pp.59-65
    • /
    • 2011
  • This study was performed to evaluate the compressive and flexural strength, void ratio and permeability coefficient used powdered waste glass, $CaCO_3$, recycled coarse aggregate and unsaturated polyester resin to find optimum mix design of permeable polymer concrete for pavement. The compressive and flexural strength of permeable polymer concrete for pavement using powdered waste glass were in the range of 16.8~19.7 MPa and 4.7~6.1 MPa, respectively. it was satisfied the regulation of permeable concrete for pavement (18 MPa and 4.5 MPa). The void ratio and permeability coefficient were decreased with increasing the powdered waste glass, respectively. The void ratio and permeability coefficient were satisfied national regulation of permeable concrete for pavement (8 % and $1{\times}10^{-2}$ cm/s). In addition, this study found out that required amount of binder was decreased with increasing the powdered waste glass. This fact is expected to have economical effects during the use of powdered waste glass in the manufacture of permeable polymer concrete for pavement. Accodingly, the powdered waste glass can be used for permeable concrete material.

투수성 반응벽에 의한 오염지하수 복원효과 분석 (Clean-up of Contaminated Groundwater by Permeable Reactive Barrier)

  • 정하익;김상근
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.542-547
    • /
    • 2000
  • It has become interested in the concept of permeable barriers for the containment and/or destruction of contaminated groundwater. The purpose of these trench-like barriers is to provide in situ capture and possibly destruction of the contaminant while preserving groundwater flow to uncontaminated zones. For instance, a trichloreethylene(TCE) plume may be contained by a permeable in which reactive iron reduces TCE to ethylene and ethane, compounds which can be easily biodegraded. The objective of this research is to examine the feasibility of using zero-valent iron as a clean-up media in permeable reactive barrier system. A series of laboratory column tests are performed. The concentration of influent and effluent water and the rate of clean up are analysed from these test results. The experimental result shows that the majority of the contamination in groundwater is removed in the reactor. And it shows the corresponding increase in the concentration of chloride ions through the reactor. Results from this study indicate that permeable reactive barrier containing admixtures of zero-valent iron and other materials can effectively clean up groundwater contaminated with organic compounds.

  • PDF