• Title/Summary/Keyword: Permanent-magnet actuator

Search Result 112, Processing Time 0.033 seconds

Optimal Design of the Optical Pickup Actuator Coil (광픽업 구동기 코일최적설계)

  • Yoon Young, Kim;Woochun, Kim;Jae Eun, Kim
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.352-355
    • /
    • 2004
  • The objective of this work is to develop a new design method to find optimal coils, especially the optimal coil configuration of an optical pickup actuator. In designing actuator coils, the developed Lorenz force in the coils along the desired direction should be made as large as possible while forces and torques in other directions should be made as small as possible. The design methodology we are developing is a systematic approach that can generate optimal coil configurations for given permanent magnet configurations. To consider the best coil configuration among all feasible coil configurations, we formulate the design problem as a topology optimization of a coil. The present formulation for coil design is noble in the sense that the existing topology optimization is mainly concerned with the design of yokes and permanent magnets and that the optimization of actuator coils is so far limited within shape or size optimization. Though the present design methodology applies to any problem, the specific design example considered is the design of fine-pattern tracking and focusing coils.

  • PDF

Improvement of Magnetic Impact Actuator for Capsule Type Moving Device (캡슐형 구동기구를 위한 자기 충격 액추에이터의 개선)

  • 민현진;곽윤근;김수현
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.652-655
    • /
    • 2003
  • This paper is about the recent development of the magnetic impact actuator for endoscope. The developed magnetic impact actuator has many problems to arrange in the system body. Because the magnetic impact actuator need a permanent magnet as an impacter, so the magnetic interference among magnets can not be eliminated. This interference causes the system size bigger. We need a new actuator design to solve these problems. One of the good solutions is to use the closed electro-magnetic circuit. This kind of circuit enhances the actuators to be independent. It is written about the design of the electro-magnetic circuit and simulation using Maxwell(version 9.0)

  • PDF

Fabrication of an Electromagnetic Actuator with the Corrugated Parylene Diaphragm (주름진 박막을 갖는 평면 코일을 이용한 전자 구동기 제작)

  • Jeong, Hyun-Ku;Jeong, Ok-Chan;Yang, Sang-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1154-1156
    • /
    • 1999
  • This paper presents the novel fabrication of an electromagnetic micro actuator with a corrugated diaphragm and a flat one. The actuator consists of a Parylene diaphragm with a spiral copper coil and a permanent magnet. The cower coil is fabricated by electroplating and patterning. As the further works, the frequency response of the actuator are obtained by using a laser vibrometer and the static deflection of the actuator diaphragm are measure by using laser displacement meter. The corrugated diaphragm is expected to be better than the flat one with respect to the actuator performance.

  • PDF

Failure Diagnosis Technology Trends and Analysis of Permanent Magnet Synchronous Motors for Aircraft Application (항공기용 영구자석 동기전동기 고장진단의 기술 동향 및 분석)

  • Minwoo, Kim;Sangho, Ko
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.6
    • /
    • pp.129-137
    • /
    • 2022
  • Recently, the technology of aircraft drivers has been transitioning from the existing hydraulically-focused mechanical system to an all-electric one due to the high precision and ease of maintenance of electric drivers. Consequently, the failure of an aircraft's electric motor can have fatal consequences. To ensure aircraft safety, efficient and timely fault diagnosis methods are required prompting the active pursuit of research into fault diagnosis technology. This paper introduces and analyses the failure types and failure diagnosis technology trends of permanent magnet synchronous motors among electric motors.

Dynamic Characteristics of Moving Coil Linear Oscillatory Actuator Considering the Variable Inductance and Push/pull Effects (가동차 위치에 따른 인덕턴스 변화와 Push/Pull 효과를 고려한 가동코일형 LOA의 동특성)

  • Jeong, Sang-Sub;Jang, Seok-Myeong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.7
    • /
    • pp.307-314
    • /
    • 2001
  • A moving coil linear oscillatory actuator is consisted of the NdFeB permanent magnets with high specific energy as the stator, a coil-wrapped nonmagnetic hollow rectangular structure and an iron core as a pathway for magnetic flux. The variation of mover position and the consequent changes of coil flux path affect the coil inductance, because coil flux leaks at the open region of LOA stator. The interaction between permanent magnet and armature field is to shift the airgap flux density variation due to the magnet alone by a certain amount. The unbalanced reciprocation force due to armature reaction field decreases the advantage of moving coil LOA, such as a high degree of linearity and controllability in the force ad motion control. This paper firstly describes the coil inductance, the deviation of flux density, and the unbalanced reciprocation force, which are derived form the permeance model of LOA. Secondly, the analytical method are verified using the 2D finite element method and tests. Finally, the dynamic simulation algorithm taking the armature reaction effect and variable inductance into account, is proposed and confirmed through the experiment.

  • PDF

Design and Analysis of Voice Coil Actuator to Drive Fuel Pump in Automobile (자동차 연료펌프 구동용 보이스 코일 전자기 엑츄에이터의 설계 및 해석)

  • Park, Se-Myung;Kim, Jin-Ho;Bai, Cheol-Ho
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.6
    • /
    • pp.234-238
    • /
    • 2010
  • Solenoid diaphragm fuel pump, which to replace mechanical fuel pump system by utilizing cam-shaft driving force, is in the spotlight for being a high efficient green car component. However, there is a drawback in power consumption as a solenoid diaphragm fuel pump only relies on solenoid for its flux needed in reciprocating motion. Therefore, this research proposes permanent magnet type VCM (Voice Coil Motor) fuel pump system to minimized power consumption. Furthermore, the study compares and analyzes power consumption and dynamic performance between the current and the former solenoid diaphragm pump by conducting finite element analysis with the commercial electromagnetic solver, MAXWELL.

Design of Hybrid Mount to Naval Shipboard Considering Shock Resistance (내충격 성능을 고려한 함정용 하이브리드 마운트의 설계)

  • Jo, Hye-Young;Shin, Yun-Ho;Moon, Seok-Jun;Jung, Woo-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.102-107
    • /
    • 2012
  • In this study, the design procedure of hybrid active mount by an electro-magnetic actuator is proposed to reduce the transmitted force from naval shipboard equipment to ship hull structure. The hybrid type mount which is composed of a passive rubber element and an electro-magnetic actuator is introduced and, through the vibration measurement for the objective pump system, the required force of the actuator is computed and discussed in detail. The initial designs were supposed for three types, one is moving coil type actuator and the others are moving permanent magnet type actuators. Based on the initial design concept, the final designs considering shock resistance and interference with mover and stator are proposed and examined.

  • PDF

The Micro Electromagnetic Force Measurement of Voice-coil Actuator using Semiconductor Piezoresistive Type Vibration Sensor (실리콘 압저항형 진동 센서를 이용한 Voice-coil형 구동기의 미소 전자력 측정)

  • Gwon, Gi-Jin;Lee, Gi-Chan;Park, Se-Gwang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.2
    • /
    • pp.147-152
    • /
    • 1999
  • Semiconductor piezoresistive type vibration sensor was fabricated by using semiconductor process and micromachining technology. To measure the micro electromagnetic force between coil and magnet, fabricated vibration sensor was used. Toapply micro electromagnetic force produced from the micro exciter, small-sized NdFeB permanent magnet was attached on the mass of the fabricated vibration sensor. The measured electromagnetic force are about 5~180dyne when the applied sinusoidal current of 1KHz in the range of 1.5~8mA. The measurement of micro electromagnetic forcewas performed by changing the distance between coil and magnet. Output characteristics of micro electromagnetic force according to the applied coil current were linear. Furthermore, output results were used to get the transfer constant that is important to decide the efficiency and the performance of the coil and magnet.

  • PDF

Characteristic Analysis of Tubular type Slotless Linear DC Motor (Slotless Tubular type 선형 직류 전동기의 특성 해석)

  • Kim, Byong-Kuk;Jo, Won-Young;Kim, Tae-Hyun;Cho, Yun-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1177-1179
    • /
    • 2005
  • This paper presents the characteristic analysis of slotless tubular type Linear DC Motor with Permanent Magnet excitation as variation of magnetic pole-pitch ratio. The stator armature winding of this motor is designed to wind at inner stator around the mover mounted with permanent magnet. First the practical model of this motor is made and its parameter is measured, after this simulation is carried out. Comparing the simulation results as variation of pole-pitch ratio, it can be seen that the reaching ability makes it useful in applications requiring a small, direct-drive actuator, which is required to extend into a specially constrained environment.

  • PDF

A Study on the Design of a Tubular Type Linear Actuator for Ultra-Small Camera Module (초소형 카메라 모듈을 위한 Tubular형 선형 액츄에이터의 설계에 관한 연구)

  • Jung, In-Soung;Hur, Jin;Sung, Ha-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.147-149
    • /
    • 2007
  • This paper presents design results of anultra-small actuator for auto focus or optical zoom function of mobile phone cameras. The consideration of the actuator is tubular type having a large hole in its center to arrange some optical lenses. The stator consists of 3-phase windings, and the mover is designed to an Nd injection permanent magnet(PM) which magnetized with multi-pole polar pattern. From the numerical analysis that taking into account the magnetizing pattern of the PM, the thrust of the designed actuator is about 40mN with the outer diameter of 7mm.

  • PDF