• 제목/요약/키워드: Peripheral dose

검색결과 337건 처리시간 0.03초

$^{60}Co\;\gamma$선과 10MV X선의 조사면 밖의 선량분포에 관한 연구 (A Study on Dobe Distribution outside Co-60 $\gamma$ Ray ana 10MV X Ray Fields)

  • 강위생;허승재;하성환
    • Radiation Oncology Journal
    • /
    • 제2권2호
    • /
    • pp.271-280
    • /
    • 1984
  • The peripheral dose, defined as the dose outside therapeutic photon fields, which is responsible for the functional damage of the critical organs, fetus, and radiation. induced carcinogenesis, has been investigated for $^{60}Co\;\gamma$ ray and 10 MV Xray. It was measured by silicon diode controlled by semiautomated water phantom without any shielding or with lead plate of HVL thickness put horizontally or vertically to shield stray radiations. Authors could obtain following results. 1. The peripheral dose was larger than $0.7\%$ of central axis maximum dose even at 20cm distance from field margin. That is clinically significant, so it should be reduced. 2. Even for square fields of 10 MV Xray, radial peripheral dose distribution did not coincide with transverse distribution, because of the position of collimator jaws. 3. Between surface and $d_m$, the peripheral dose distributions show a pattern of the dose distribution of electron beams and the maximum doss was approximately proportional to the length of a side of square field. 4. The peripheral doses depended on radiation quality, field size, distance from field margin and depth in water. Distance from field margin was the most important factor. 5. Except for near surface, the peripheral dose from phantom was approximately equal to that from therapy unit. 6. To reduce the surface dose outside fields, therapist should shield stray radiations from therapy unit by lead plate of at least one HVL for 10 MV X-ray and by bolus equivalent to tissue of 0.5cm thickness for $^{60}Co$. 7. To reduce the dose at depth deeper than $d_m$, it is desirable to shield stray radiations from therapy unit by lead.

  • PDF

고정형쐐기(Physical Wedge)와 동적쐐기(Dynamic Wedge)의 조사야 주변 선량에 관한 연구 (A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge)

  • 민제순;나경수;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.77-82
    • /
    • 2007
  • 목 적: 목적: 2D-ARRAY chamber를 이용하여 고정형쐐기(Physical wedge filter)와 동적쐐기(Dynamic wedge)의 조사야 주변의 선량을 비교하여 평가하였다. 대상 및 방법: 고체팬텀위에 2D-ARRAY seven29 (PTW, Germany) chamber를 이용하여 조사야 10$\times$10, SSD 90 cm로 고정시키고 에너지는 6 MV와 15 MV로 변화시켜 5 mm 깊이의 조사야 밖 선량을 측정하였다. 쐐기필터15$^\circ$, 45$^\circ$동적쐐기와 선형가속기에 장착된 동적쐐기의 15$^\circ$, 45$^\circ$를 측정하여 조사야 끝에서 쐐기의 heel부분과 toe부분의 1 cm 되는 지점에서 5 cm 지점까지의 1 cm 간격으로 주변선량을 비교, 분석하였다. 선량은 최대선량지점에 대한 표면에 근접한 5 mm 깊이와 5 cm 깊이의 백분율로 선량값을 얻었다. 결 과: 6 MV 에너지는 동적쐐기가 고정형쐐기보다 조사야 주변 선량이 0.1$\sim$1.4%정도 모두 낮았다. 15 MV 에너지는 조사야에서 근접한 거리에서 동적쐐기의 선량이 0.4$\sim$0.9%정도 높지만 멀어지면서 급격하게 감소하여 동적쐐기가 최대 1.6% 낮게 측정되었다. 경사각 15$^\circ$와 45$^\circ$에서의 선량차이는 크지 않았으며, 동적쐐기는 heel 부분과 toe부분의 선량차이가 없는 반면 고정형쐐기는 에너지가 크고 쐐기 각도가 클수록 heel부분 보다 toe부분의 선량이 2%정도 높게 측정되었다. 결 론: 동적쐐기와 고정형 쐐기가 조사야 내에서는 같은 선량분포를 갖는 반면 조사야 주변에서는 동적쐐기가 고정형쐐기보다 선량이 낮았다. 따라서 동적쐐기를 사용할 경우 치료주위선량을 감소시킬 수 있으므로 치료부위와 근접한 표면에 가까운 주요장기의 선량을 최소화 할 수 있으며, 치료시간도 단축시킬 수 있었다.

  • PDF

6 MV X선의 주변선량분포 (A Study on the Peripheral Dose of 6MV X-ray Beam)

  • 최두호;김일한;하성환;박찬일
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.24-33
    • /
    • 1989
  • 방사선 치료시 조사면 밖의 신체부위에도 소량의 방사선이 흡수되며 이러한 소량의 방사선은 치료부위에 따라서는 백내장, 생식기능장애, 태아에 대한 영향등으로 나타날 수 있다. 조사면 밖에서 흡수되는 방사선량인 주변선량의 양과 분포양상 및 이에 영향을 주는 요인을 규명하기 위하여 자동식 제어장치에 의해 제어되는 실리콘 다이오드 측정기를 이용 6MV X선을 조사하면서 주변선량을 물팬톰내에서 측정하였다. 조사면의 크기, 콜리메이터의 위치, 쐐기필터의 존재여부 및 쇄기필터의 각도가 주변선량에 미치는 영향을 측정하여 다음과 같은 결과를 얻었다. 1. 주변선량은 조사면의 경계선에서 멀어질수록 감소하지만 15cm 떨어진 부위에서도 최대 흡수선량의 2.4% $\sim$ 5%에 이른다. 2. 주변선량은 수표면으로부터 깊이 2-3mm 근처까지 선량증가 현상이 나타나 수표면 보다 0 $\sim$ 0.3%까지 높아지며 이후 급격히 감소하여 1.5cm 근처에서 0.5 $\sim$ 5%의 최소치에 도달한 후 다시 3 $\sim$ 8%로 증가한다. 3. 주변선량은 조사면의 크기가 클수록 증가하여 조사면 경계선에서 10cm깊이 5cm거리에서 조사면 5 $\times\;5cm^2$인 경우와 20 $\times\;20cm^2$인 경우 각각 3.5%와 8.2%로서 조사면의 크기에 따라 2배이상의 증가를 보인다. 4. 상부 콜리메이터 방향의 주변선량이 하부 콜리메이터 방향의 주변선량에 비하여 높으며 그 차이는 1% 미만이다. 5. 쐐기 필터를 사용시에는 개방조사면의 경우에 비하여 주변선량이 증가되었으며 특히 얇은 방향의 주변선량이 높아 각도가 60$^{\circ}$이고 조사면의 크기가 15 $\times\;15cm^2$일때 조사면 경계선으로부터 5cm거리에서는 3%정도의 주변선량의 차이를 보인다. 6. 쐐기필터의 각도가 클수록 주변선량이 증가하여 패기필터의 각도가 60$^{\circ}$일때에는 개방조사면에 비하여 약 2배 정도로 주변 선량이 증가한다.

  • PDF

광자선에 의한 민조사면 경계영역의 선량분포 (Peripheral Dose Distributions of Clinical Photon Beams)

  • 김진기;김정수;권형철
    • 한국의학물리학회지:의학물리
    • /
    • 제12권1호
    • /
    • pp.71-77
    • /
    • 2001
  • 방사선조사면의 가장자리는 반음영 영역으로 선량변화가 급격한 부분이다. 이러한 부분은 메가볼트 광자선 영역의 조사면에서 선원크기, 콜리메이터, 차폐불럭, 보조기구 그리고 내부산란선에 의한 것으로 알려져 있다. 본 연구에서는 기준조사면 경계 영역의 선량특성을 확인하고 선험적인 이론적 관계식으로 비교하여 치료시스템 조사면의 특성을 알고자 하였다. 조사면 경계영역의 주변선량분포를 깊이와 중심축으로부터 거리의 함수로서 구성하여 6MV 광자선에 의한 민조사면 경계영역의 주변선량분포를 측정하고 이를 선험적인 함수분포와 비교하였다. 3차원 물 팬톰으로 조사면 가장자리 영역의 주변선량분포를 측정하고 이를 선험적인 함수값과 비교하여 측정치와 근접한 함수방법을 알아보았다. 반도체 검출기와 전리함으로 최대선량점, 5 cm , 10 cm 깊이의 위치에서 측정값의 비를 이용하고, 유효 가장자리 영역은 80-20 % 를 선택하여 거리의 함수로 분석하였다. 깊이가 증가함에 따라경계영역의 선량폭이 증가하였다. 주변선량분포에서 검출기의 특성에 따라서 측정값과 함수값에 작은 차이가 있었다. 민조사면 경계영역 선량 분포함수를 비교하였다.

  • PDF

고정형 쐐기(Physical wedge)와 동적 쐐기(Dynamic wedge)의 조사야 주변 선량에 관한 연구 (A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge)

  • 고신관;민제순;나경수;이제희;박흥득;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.407-413
    • /
    • 2008
  • 2D-ARRAY chamber를 이용하여 고정형쐐기(Physical wedge filter)와 동적쐐기(Dynamic wedge)의 조사야 주변의 선량을 비교 평가하고자 하였다. 고체팬텀 위에 2D-ARRAY seven 29 (PTW, Germany) chamber를 이용하여 조사야 $10cm{\times}10cm$, SSD 90cm로 고정시키고, 에너지는 6MV와 15MV로 변화시켜 산란선의 영향을 많이 받는 피부 깊이인 5mm 깊이의 조사야 밖 인접 선량을 측정하였다. 고정형 쐐기 $15^{\circ}$, $45^{\circ}$와 선형가속기에 장착된 동적쐐기의 $15^{\circ}$, $45^{\circ}$를 측정하여 조사야 끝에서 쐐기의 heel부분과 toe 부분의 1cm되는 지점에서 5cm 지점까지의 1cm 간격으로 주변선량을 비교, 분석하였다. 6MV 에너지는 동적쐐기가 고정형쐐기 보다 조사야 주변 선량이 $0.1{\sim}1.4%$ 정도 모두 낮았다. 15MV 에너지는 조사야에서 근접한 거리에서 동적쐐기의 선량이 $0.4{\sim}0.9%$ 정도 높지만 멀어지면서 급격하게 감소하여 동적쐐기가 최대 1.6% 낮게 측정 되었다. 동적쐐기는 heel부분과 toe부분의 선량차이가 없는 반면 고정형쐐기는 에너지가 높고 쐐기 각도가 클수록 heel부분 보다 toe부분의 선량이 2% 정도 높게 측정되었다. 따라서 동적쐐기를 사용할 경우 치료주위선량을 균일하게 감소시킬 수 있으므로 치료부위와 근접한 표면에 가까운 주요장기의 선량을 최소화 할 수 있었다.

  • PDF

정상 ICR mouse 및 SD rat에서 CJ-50001 (rG-CSF)의 단회투여후 말초호중구수의 변동 및 용량상관성 (The Effect of a Single Administration of rG-CSF on the Peripheral Neutrophil Levels and Its Dose Responsiveness in Normal ICR mice and SD rats)

  • 임동문;조효진;김달현;이현수;김제학;김현수
    • Biomolecules & Therapeutics
    • /
    • 제5권4호
    • /
    • pp.380-383
    • /
    • 1997
  • CJ-50001 is a recombinant granulocyte-colony stimulating factor (rG-CSF) developed by Cheil Jedang R&D Center. The effects of CJ-50001 on the increase of peripheral neutrophil count following intravenous and subcutaneous single administration at a dose of 20$\mu$g/kg in normal ICR mice and SD rats, respectively, were compared with those of Grasin, a control drug. Both CJ-50001 and Grasin significantly increased the peripheral neutrophil number in four treatment groups and the maximum number of neutrophil was achieved at 12 to 18 h in rats and mice, respectively. The dose dependency test was studied for CJ-50001 only in normal mice by intravenous or subcutaneous administration. When administered i.v or s.c at the various doses in normal mice, CJ-50001 significantly increased the neutrophil number over the dose of 160 ng/kg, compared with the vehicle control group. From these results, it was concluded that CJ-50001 showed efficacy similar to Grasin in the peripheral neutrophil count increase.

  • PDF

저선량의 감마선 피폭된 사람 말초 임파구의 미소핵을 이용한 방사선 생물학적 피폭선량 측정법 연구 (Cytokinesis-blocked micronuclei in the human peripheral lymphocytes following low dose γ-rays irradiation)

  • 김태환
    • 대한수의학회지
    • /
    • 제41권1호
    • /
    • pp.99-104
    • /
    • 2001
  • 불의의 방사선 피폭 환자의 체내 방사선 피폭선량의 예측을 위한 방사선 생물학적 선량측정 개발의 일환으로 저선량 피폭환자의 체내 피폭선량 측정 지표로서의 미소핵 분석법 이용 가능성을 평가하기 위하여 코발트-60 감마선을 0.25 Gy에서 1 G의 선량을 인체 말초 혈액에 조사한 후 임파구내에 미소핵의 수적 변화를 형태학적으로 관찰하였다. 저선량에 피폭된 임파구에서 미소핵이 관찰되었으며, 선량에 따른 수적인 변화도 나타났다. 저선량 피폭에 대한 미소핵의 수적 변화에 대한 선량-반응 곡선은 $Y=(0.02{\pm}0.0009)+(0.033{\pm}0.010)D+(0.012{\pm}0.012)D^2$의 식을 얻었으며, linear quadratic model 이였다. 이상의 결과에서 미소핵의 발생 빈도와 피폭 선량간에 유의한 효과가 있는 것으로 확인되었다. 그리고 정상대조군에서는 세포당 $0.02{\pm}0.0009$개가 관찰되었다. 따라서 말초 임파구를 이용한 미소핵 분석법은 저선량 피폭환자의 체내 피폭선량 측정은 물론 방사선 방호제의 검색 및 방사선 민감도 검사를 위한 방사선 생물학적 지표로 이용 가능하며, 특히 이 방법은 간편하고 정확하며 재현성이 있는 방법으로 불의의 방사선 피폭 사고시 체내 피폭선량을 예측하는 좋은 지표로 사용되어질 수 있을 것으로 사료됨.

  • PDF

Wedge Filter가 주변선량분포에 주는 영향에 관한 연구 (A Study on the Effects of Wedge Filter in Peripheral Dose Distribution)

  • 강위생;김일한;박찬일
    • Radiation Oncology Journal
    • /
    • 제3권2호
    • /
    • pp.145-151
    • /
    • 1985
  • Wedge filter를 사용할 때 $^{60}Co\;\gamma$선과 10MV X-선의 주변선량분포를 반자동식 물팬톰장치에 의해 제어되는 고체 방사선검출기로 측정하였다. wedge filter의 날과 등의 방향을 잇는 주단면상에서 주변선량을 측정하였다. 방사선의 투과력과 wedge 각, wedge에 대한 방향, 조사면의 변화에 대하여 주변선량의 면화를 고찰하였다. 선축에 수직인 방향의 측정은 깊이 dm, 5cm, 10cm, 15cm에서 선측과 평행인 방향에서는 조사면 경계에서 3cm, 5cm, 10cm 떨어진 위치에서 측정이 이루어졌다. 측정으로부터 wedge가 사용되는 조사면에 대한 주변선량분포가 아래와 같음을 볼 수 있었다. 1. wedge filter의 날의 방향의 주변선량이 등의 방향의 주변선량보다 높았다. 2. 표면근처에서는 깊이가 깊어짐에 따라 선량이 감소하였다. 3. $^{60}Co\;\gamma$선의 경우 어떤 깊이에서는 조사면의 경계로부터 거리가 떨어짐에 따라 주변선량이 단조감소하지 않고 다시 증가하는 영역이 있었다. 4. wedge를 사용하는 경우 주변선량은 방사선의 투과력이나 조사면의 크기뿐만 아니라 wedge의 각과 방향에도 영향을 받는다.

  • PDF

1형과 2형 당뇨모델 흰쥐에서 Chromium Picolinate의 당내성과 인슬린 감수성에 대한 영향 (Effect of Chromium Picolinate on Glucose Tolerance and Insulin Sensitivity in the Type I and II Diabetic Rats)

  • 신현진;홍정희;고현철;신인철;강주섭;최호순;김태화;김동선;엄애선
    • Biomolecules & Therapeutics
    • /
    • 제9권4호
    • /
    • pp.277-281
    • /
    • 2001
  • Chromium is an essential nutrient and participates in glucose and lipid metabolism in human beings and animals. The present study was conducted to assess the effects of chromium picolinate (Cr-pic) on glucose tolerance and insulin sensitivity in type I and ll diabetic rats. The experimental groups were type I diabetic (streptozotocin-induced: 40 mg/kg, i.p.) and type II diabetic (Goto-Kakizaki rats) models. Each group was subdivided into control. low-dose and high-dose of Cr-pic treated groups. The Cr-pic was orally administered with Cr-pic (100 mg/kg for low dose group and 200 mg/kg for high dose group) for 4 weeks. And then we performed intraperitoneal glucose tolerance test (IPGTT) and insulin sensitivity test (ITT). The glucose tolerance test was carried out by inection of glucose (2 g/kg, i.p.). The peripheral insulin sensitivity test was con- ducted by injection of insulin (5 units/kg, s.c.) and glucose. We performed determining of blood glucose concentration at 0, 10, 30, 60, 90, and 120 min using automated glucose analyzer. The plasma insulin concentration was determined by rat insulin EIA kit. Administration of Cr-pic improved weight gain in all group s with higher significant in the low-dose group. There was no significance between the control and the Cr-pic treated groups in the area under the blood glucose curve and serum insulin concentration plots of IPGTT and peripheral ITT in type I diabetic rats. But Cr-pic treated groups showed significantly lower levels of the area under the blood glucose currie during IPGTT and ITT and the high-dose group showed less effects compared with the low-dose group in the type II diabetic rats. The plasma insulin concentration of both diabetic groups was not influenced by Cr-pic supplementation. We can conclude that chromium picolinate may improve the endogenous and exogenous insulin action and peripheral insulin sensitivity in type II diabetic rats.

  • PDF

호중구 감소증을 유도한 마우스에서의 유전자 재조합 인과립구 콜로니자극인자의 효과 (Effects of Recombinant truman Granulocyte Colony-Stimulating Factor(rhG-CSF) on Cyclophosphamide-induced Neutropenic Mice)

  • 조명행;유아선;방명주;곽형일;성하정;안길환
    • Biomolecules & Therapeutics
    • /
    • 제6권2호
    • /
    • pp.145-150
    • /
    • 1998
  • Administration of 3 type KGCs [recombinant human granulocyte colony-stimulating factor (rhG-CSF)] to mice with cyclophosphamide (CPA)-induced neutropenia for 4 consecutive days from the day after the CPA dosing (100 mg/kg) resulted in a dose dependent increase in the peripheral blood neutrophil count 6 hours after the final KGC injection. Within the KGC dose range of 0.1 to 40$\mu$g Per mouse Per day, there was a sigmoidal relationship between the logarithm of the dose and the peripheral blood neutrophil count (relative value for neutrophil count of the basal dose) in the treated mice. The sigmoidal relationship of test KGC preparations shows that there is a saturation point in terms of efficacy. Compared with e(fact of KGC-Orange, Green, and Blue, KGC-Orange recovers neutrophils more effectively than the others do.

  • PDF