• 제목/요약/키워드: Periodic replacement criteria

검색결과 7건 처리시간 0.023초

누적통과톤수에 의한 레일교체기준의 타당성 분석 (A Study on Logicality for the Periodic Replacements of Continuous Welded Rail based on Accumulated Passing Tonnage)

  • 성덕룡;공선용;김박진;신효정;박용걸
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1058-1070
    • /
    • 2007
  • Internal and external railway management corporations are using the periodic replacement criteria of rail by accumulated passing tonnage and wear to maintain rails for servicing. However, internal the periodic replacement criteria of continuous welded rail(CWR) by accumulated passing tonnage is the one(50kg/m-5 million gross tonnage, 60kg/m-6 million gross tonnage) presented in Japan before. It was estimated with the fatigue life about 50kg N rail joints applied diesel train load but it wasn't applied to current conditions of track; elimination of rail joint, using the concrete slab track and operation of light train load and effect of welding, manufacturing technique, grinding of rail. Therefore, in this study, it was investigated the types of damage and cause in welded rails and examined standards and information resources. Also, this study presents preliminary data to revise the periodic replacement criteria of CWR by current accumulated passing tonnage in bending test of laid welded rail and a survey of track maintenance history of Seoul metro.

  • PDF

누적통과톤수에 의한 국내 레일교체기준의 타당성 평가 (Logicality Estimate for Domestic the Periodic Replacement Criteria of CWR based on Accumulated Passing Tonnage)

  • 박용걸;서상교;최정열
    • 한국철도학회논문집
    • /
    • 제11권3호
    • /
    • pp.326-333
    • /
    • 2008
  • 본 논문은 누적통과톤수에 의한 레일교체기준 개정을 위한 기초 데이터를 제시하는데 목적이 있다. 본 연구에서는 국외의 누적통과톤수에 의한 레일교체기준의 산정근거를 조사하였으며, 일본에서 조사된 레일용접부 결합유형 및 원인과 국내 철도운영기관인 서울메트로의 궤도유지관리이력을 조사하여 실제 레일절손과 누적통과톤수의 상관관계를 분석하였다. 또한, 누적통과톤수 기준치에 도래한 노후레일 용접부를 현장에서 발췌하여 레일용접부 휨시험을 수행하였다. 그 결과, 누적통과톤수와 레일절손간의 상관관계는 뚜렷하지 않았으며 레일용접부의 시공불량에 의한 절손사례가 많은 것으로 분석되었다. 또한, 노후레일휨시험 결과 신규레일용접부에 비해 파괴강도가 $17{\sim}18%$만이 저하된 것으로 나타나 레안교체기준에 도래한 노후레일은 사용성 측면에서 충분한 내구성 및 내하력을 확보하고 있는 것으로 분석되었다.

몬테카를로 시뮬레이션을 통한 노후 디젤발전설비 교체기준 고찰 (Investigation on Replacement Criteria for Aged Diesel Driven Power Generation Facility by Monte Carlo Simulation)

  • 박명수;송기욱;서상일;원동주
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제2권2호
    • /
    • pp.89-97
    • /
    • 2014
  • 내륙의 주전력 공급계통과 단절되어 있는 도서지역은 대부분의 전력공급을 디젤발전설비가 담당하고 있다. 디젤발전설비는 특성상 예방정비 및 유지보수를 통해 사용수명을 연장시킬 수 있으나, 계속 사용에 따른 기계설비의 노후화 및 발전 효율 감소로 인해 운영비가 증가한다. 즉, 적기에 노후 발전설비를 교체할 경우 발전소 운영비용을 줄일 수 있다. 이에 본 연구에서는 디젤발전설비의 상태를 대표할 수 있는 지표를 도출하고, 몬테카를로 시뮬레이션을 이용하여 각 지표별 민감도 분석을 수행하고자 한다. 이를 통해 디젤발전설비의 현상태를 정량적으로 나타낼 수 있는 상태점수를 정의하고 이를 바탕으로 설비 교체의 기준을 마련하고자 한다.

달비계용 PP섬유로프의 야외노출에 따른 인장강도 변화 분석 (Analysis of Tensile Strength Changes by Outdoor Exposure of Scaffolding PP Fiber Rope)

  • 강성윤;정기효
    • 대한안전경영과학회지
    • /
    • 제25권3호
    • /
    • pp.31-36
    • /
    • 2023
  • The use of hanging scaffolding for exterior wall painting and cleaning in building construction and maintenance carries the inherent risk of fall accidents. While periodic rope replacement is crucial for preventing accidents resulting from rope breakage, current regulations lack specificity in determining appropriate disposal period for fiber ropes. This study analyzed the tensile strength of the most commonly used PP fiber ropes with different diameters (16 mm, 20 mm) in the domestic construction industry. Additionally, the effect of outdoor exposure was examined by measuring the tensile strength of new ropes and ropes exposing to outdoor conditions for 30 days and 90 days. The results showed that the new ropes and those exposed to outdoor for 30 days met the KS (Korean Standards) criteria for tensile strength. However, a significant decrease in tensile strength was observed in ropes exposed to outdoor for 90 days compared to both the new ropes and those exposed for 30 days. Furthermore, the ropes exposed for 90 days did not meet the KS criteria. These findings indicate the degradation of PP fiber ropes due to UV (Ultra Violet) radiation, highlighting the importance of considering this factor when determining the replacement period for fiber ropes used in scaffolding work.

도시철도 콘크리트궤도 장대레일의 피로수명 평가 (The Fatigue Life Evaluation of Continuous Welded Rail on a Concrete Track in an Urban Railway)

  • 공선용;성덕룡
    • 한국철도학회논문집
    • /
    • 제17권3호
    • /
    • pp.193-200
    • /
    • 2014
  • 본 연구에서는 도시철도 콘크리트궤도 장대레일에 대한 실내피로시험을 수행하였고, 장대레일 잔존수명을 표현한 파괴확률 50% S-N 선도는 적은 실험데이터에 대한 가중치 확률 해석기법을 사용하여 도출하였다. 여기서 피로시험에 사용된 레일들이 누적통과톤수가 서로 다르기 때문에 누적통과톤수를 평균하여 반복횟수를 수정하였다. 또한, 레일표면요철 및 열차속도를 고려한 레일 저부 휨응력은 기존 연구결과 도출된 레일휨응력 예측식을 사용하여 콘크리트궤도 장대레일의 잔존수명을 평가하였다. 레일 피로수명 평가결과, 레일 피로수명이 기준치에 비해 약 2억톤이상 높았다. 또한, 자갈궤도에 비해 콘크리트궤도 레일의 피로수명이 약 3억톤이상 높은 것으로 분석되었다. 따라서 도시철도에서 레일교체기준을 자갈궤도와 콘크리트궤도로 구분할 필요가 있으며, 레일연마를 통한 레일관리가 이루어진다면 기준치가 아닌 목표치로 관리할 수 있을 것으로 판단되었다.

장대 아치교 행어 파단에 의한 동적 해석 (Dynamic Analysis of Long-span Arch Bridge by Fracturing Hangers)

  • 임성순;공민식;유이슬
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제14권2호
    • /
    • pp.113-120
    • /
    • 2010
  • 장대 아치교 설계 시 시공단계와 완성단계에서 발생할 수 있는 문제에 대하여 검토하고 있으나 케이블 손상에 대한 구조안전성 평가는 매우 미흡한 실정이다. 따라서 본 연구는 공용 중 충돌사고로 인한 행어 파단 시 교량의 구조안전성을 분석하는 것을 연구 목적으로 한다. 이를 위하여 행어 파단에 따른 하중을 충격함수로 이상화하여 동적 해석을 수행하였다. 행어가 파단 되었을 경우 각 행어의 최대 장력은 파단된 행어와 인접한 행어에서 발생한 것으로 나타났으며 정적 하중보다 동적 하중에서 크게 나타났다. 그러므로 장대 아치교의 구조안전성을 확보하기 위해 행어 파단에 따른 충격하중을 동적 하중으로 고려한 해석이 필요하다. 또한 본 연구의 해석 방법 및 결과는 이후 아치교 설계 시 참고자료로 활용될 수 있다.

Dynalog file을 이용한 동적다엽조준기의 Leaf 속도 정도관리 평가 (Quality Assurance of Leaf Speed for Dynamic Multileaf Collimator (MLC) Using Dynalog Files)

  • 김주섭;안우상;이우석;박성호;최원식;신성수
    • 대한방사선치료학회지
    • /
    • 제26권2호
    • /
    • pp.305-312
    • /
    • 2014
  • 목 적 : 동적다엽조준기(dynamic multileaf collimator, DMLC)에서 leaf 속도 정도관리 시 획득된 dynalog 파일을 이용하여 leaf 속도 정확성을 평가하고 정도관리와 모터 교체의 연관성을 분석하여 정도관리의 유용성을 살펴보고, 이를 통해 leaf 속도 정도관리의 적절한 주기를 파악하고자 하였다. 폐암의 정위적체부방사선치료시 실제 적용하고 있는 최대강도투사(MIP) 영상과 호흡위상별(0~90%)영상에서 3차원적으로 재구성된 선량 분포 차이를 평가하고자 한다. 대상 및 방법 : 다엽조준기(multileaf collimator, MLC) 모터 120개에 대해 2012년 1월부터 2014년 6월까지 leaf 위치의 정확성과 치료 중심점(isocenter) 일치도 및 leaf 속도의 정확성에 대해 정도관리를 하였다. leaf 위치 정확성은 모눈종이를 사용하였으며, 또한 leaf의 치료 중심점 일치도를 평가하였다. 그리고 약 1~2 주에 1회씩 총 92회의 leaf 속도 정도관리를 통해 모터 교체회수를 파악하여 leaf 속도 정도관리와 모터 교체와의 상관관계를 분석하였으며, 교체된 모터로부터 leaf의 RMS 값이 점차적으로 증가하는 경우와 급격하게 증가하는 경우로 나누어 적절한 정도관리 주기를 평가하였다. 또한 정도관리를 통해 획득된 RMS 값과 전혀 무관하게 그리고 정도관리를 통해 교체된 모터 횟수를 분석하여 leaf 속도 정도관리의 유용성을 알아보았다. 결 과 : leaf 위치의 정확성과 치료 중심점 일치도를 측정한 결과는 TG-142 보고서에서 권고 하는 허용 범위 이하의 정확성으로 관찰되었고, leaf 속도 정도관리는 총 92회를 시행한 결과 MLC 모터 교체 회수는 56회 이었다. 정도관리를 통해 교체된 모터에서 leaf의 RMS 값이 점차적으로 증가한 경우가 급격하게 증가한 경우에 비해 많았으며, RMS 값이 점차적으로 증가하는 경우는 평균값이 0.298 cm 이었고 급격하게 증가한 경우는 평균값이 0.273 cm 이었다. 모두 에러 히스토그램이 1 cm 이상 벗어난 횟수가 측정되어 교체하였다. RMS 값이 점차적으로 증가하여 모터가 교체될 때까지의 소요기간은 평균 22일 정도 였다. 전체 모터 교체 중 정도관리와 무관하게 그리고 정도관리를 통해 교체한 경우가 각각 28회씩으로 나타났다. 또한 방사선치료 도중 MLC 모터 고장으로 인하여 발생되는 치료 지연 시간은 약 20분 정도였다. 결 론 : 본 연구에서는 최근 IMRT 치료가 증가함에 따라 MLC 사용 빈도 역시 증가하고 있는 시점에서 leaf 위치 정확성 및 치료 중심점 일치도 그리고 속도 정확성 평가를 2년 6개월 동안 수행하였다. leaf 속도 정도관리를 통해 분석한 결과로부터 2 주에 한 번씩 정도관리를 수행하는 것이 적절한 것으로 판단된다. 이 주기를 통해서 leaf 속도 저하를 추적 관찰하여 최종 모터의 교체시기를 예측할 수 있을 것이다. 더불어 방사선치료 중 leaf의 모터 고장으로 인한 방사선치료 지연을 방지하여 좀 더 정확한 IMRT 치료가 이루어지겠다.