• Title/Summary/Keyword: Periodic replacement

Search Result 96, Processing Time 0.024 seconds

Analysis of Drug Compliance Status for the Hormone Replacement Therapy (HRT) Treatment Patients (호르몬대체요법 환자의 복약실태분석)

  • Hong, Sun Shik;Lee, Eui Kyoung
    • Korean Journal of Clinical Pharmacy
    • /
    • v.10 no.1
    • /
    • pp.7-12
    • /
    • 2000
  • This study is intended to provide information to menopausal women so they can control their symptoms. The basic data was gathered by interviewed 200 postmenopausal women on a HRT program. The women were questioned about their perception of menopause and compliance to the therapy with the fellowing result $71.7\%$ of the women experianced hot flushes, and $64.1\%$ experienced short term memory loss and some psychological symptoms. The women reported that these symptoms reduced their quality of life. $53\%$ of the women responded that menopause is a natural state and $59.1\%$ agreed to HRT based on their doctor's recommendation. $76.2\%$ of the women reported that HRT was effective, with $74.7\%$ reporting reduced hot flush symptoms $67.3\%$ of the women reported compliance with the medication schedule. and $43.9\%$ reported periodic non-compliance. Although HRT has been shown to be an effective treatment, the study found that less than $10\%$ of postmenopausal women are currently being treated and these treated women are generally negligent in continuing with HRT, The study recommends that a program be developed that explains the benefits and risks of HRT to be distributed to patients being treated by doctors and pharmacists. In conclusions, It is very important for hormone replacement therapy on menopausal women to take more intensive medication consultation to increase medication compliance and effectiveness of pharmacotherapy.

  • PDF

Changes in the Nutrient Components Associated with the Growth of Lettuce in Circulating Hydroponics (순환식 양액재배에서 상추의 성장에 따른 양액성분의 변화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.24 no.8
    • /
    • pp.1075-1084
    • /
    • 2015
  • This study was conducted to investigated the changes in the nutrient components ($NO_3{^-}-N$, $NH_4{^+}-N$, $PO_4{^{3-}}P$, $K^+$, $Ca^{2+}$, and $Mg^{2+}$) and environmental parameters (electrical conductivity, total dissolved solids and pH) on the leaf lettuce (Lactuca sativa L.) grown with hydroponics. Recirculating hydroponic cultivation system was consisted of planting port, LED lamp, water tank, and circulating pump for hydroponic. Nutrient solution was used in the standard solution for Japan vegetables experimental station and commercial hydroponic. The result showed that electrical conductivity (EC), total dissolved solids (TDS) and pH, depending on the growth of lettuce decreased continuously. With the growth of the lettuce, nitrate nitrogen, ammonia nitrogen, phosphate phosphorus were required for periodic replacement. The number of pH compensation due to the growth of lettuce are the most high. The concentration of $Ca^{2+}$ and $Mg^{2+}$ during the lettuce growth showed no significant change. However, $K^+$ concentration increased due to the replacement with nitrogen and phosphorus. Electric conductivity and total dissolved solids with total nutrient concentration showed the linear relationship and the correlation coefficient $R^2$ were 0.8601 and the 0.827, respectively.

Time-series Analysis of Geodetic Reference Frame Aligned to International Terrestrial Reference Frame

  • Bae, Tae-Suk;Hong, Chang-Ki;Lee, Jisun;Altamimi, Zuheir;Sillard, Patrick;Boucher, Claude
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.39 no.5
    • /
    • pp.313-319
    • /
    • 2021
  • The national geodetic reference frame of Korea was adopted in 2003, which is referenced to ITRF (International Terrestrial Reference Frame) 2000 at the epoch of January 1, 2002. For precise positioning based on the satellites, it should be thoroughly maintained to the newest global reference frame. Other than plate tectonic motion, there are significant events or changes such as earthquakes, antenna replacement, PSD (Post-Seismic Deformation), seasonal variation etc. We processed three years of GNSS (Global Navigation Satellite System) data(60 NGII CORS stations, 51 IGS core stations) to produce daily solutions minimally constrained to ITRF. From the time series of daily solutions, the sites with unexpected discontinuity were identified to set up an event(mostly antenna replacement). The combined solution with minimum constraints was estimated along with the velocity, the offsets, and the periodic signals. The residuals show that the surrounding environment also affects the time series to a certain degree, thus it should be improved eventually. The transformation parameters to ITRF2014 were calculated with stability and consistency, which means the national geodetic reference frame is properly aligned to the global reference frame.

Analysis of Tensile Strength Changes by Outdoor Exposure of Scaffolding PP Fiber Rope (달비계용 PP섬유로프의 야외노출에 따른 인장강도 변화 분석)

  • Sung-Yun Kang;Kihyo Jung
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.3
    • /
    • pp.31-36
    • /
    • 2023
  • The use of hanging scaffolding for exterior wall painting and cleaning in building construction and maintenance carries the inherent risk of fall accidents. While periodic rope replacement is crucial for preventing accidents resulting from rope breakage, current regulations lack specificity in determining appropriate disposal period for fiber ropes. This study analyzed the tensile strength of the most commonly used PP fiber ropes with different diameters (16 mm, 20 mm) in the domestic construction industry. Additionally, the effect of outdoor exposure was examined by measuring the tensile strength of new ropes and ropes exposing to outdoor conditions for 30 days and 90 days. The results showed that the new ropes and those exposed to outdoor for 30 days met the KS (Korean Standards) criteria for tensile strength. However, a significant decrease in tensile strength was observed in ropes exposed to outdoor for 90 days compared to both the new ropes and those exposed for 30 days. Furthermore, the ropes exposed for 90 days did not meet the KS criteria. These findings indicate the degradation of PP fiber ropes due to UV (Ultra Violet) radiation, highlighting the importance of considering this factor when determining the replacement period for fiber ropes used in scaffolding work.

Bending Fatigue Life Assessment of Aged CWR using the Field Test (현장측정을 통한 노후레일의 휨 피로수명 평가)

  • Park, Yong-Gul;Sung, Deok-Yong;Park, Hong-Kee;Kong, Sun-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.3
    • /
    • pp.317-325
    • /
    • 2008
  • As a result of recent research, it is reported that the periodic replacements criterion of rails is able to extend as grinding rail surface and using the continuous welded rail (CWR). This study evaluated correlation between conditions of track and load capacity of rail by analysing the dynamic response of track while the metro train is running. Also, it was converted the measured stress waveform into stress frequency histogram by the rain-flow counting methods, and then accumulated fatigue damage ratio and remaining service life of laid rail were calculated so as the apply the equivalence of stress to S-N curve of a new welded rail. Finally, this study suggests a revision of the periodic replacements criterion of CWR, which was based on accumulated passing tonnage, classified by the types and conditions of track system.

High-temperature Mechanical Properties Measurement and Life Assessment of Boiler Equipment by Instrumented Indentation Technique (계장화 압입시험법을 이용한 보일러 설비의 고온 기계적 물성 측정과 수명 평가)

  • Ro, Dong-Seong;Hong, Jeong-Wha;Kim, Kwang-Ho;Lee, Jung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.3
    • /
    • pp.1-6
    • /
    • 2009
  • Recently power plants and oil refineries are focusing on capacity enlargement for better efficiency through higher temperature and higher pressure. Thickness of boiler tubes becomes lessened due to oxidation and erasion caused by high temperature bums gas flowing over tubes outside. Accordingly, mechanical stress of tubes is increasing and that is a critical factor to make a crack and fracture. To prevent those sorts of accidents, aging assessment for proper periodic repair and replacement should be conducted reliably and reasonably. We performed IIT test on Cr-Mo steel, one of the most heat-resistant materials for facilities in power plants, and we report the test result and the considerable effectiveness of IIT test.

Rejuvenation Technologies for Hot Gas Path Components made of Nickel Based Superalloys (니켈기 초합금 소재 고온부 부품의 재생정비기술)

  • Kang, Sin-Ho;Choi, Heui-Sook;Kim, Dae-Eun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.424-429
    • /
    • 2003
  • Hot gas path components, which are made of nickel based superalloys, are subject to periodic replacement due to degradation of thermomechanical properties that might bring catastrophic failure during normal operation of gas turbine units. In order to rejuvenate the metallurgical condition of the serviced components, heat treating techniques such as solution annealing and aging heat treatments have widely been employed. However, the effectiveness of those typical heat treatments is not apparent enough in terms of quantitative grounds. On the other hand the demand of the rejuvenation heat treatment and hot isostatic pressing (HIP) have constantly been raised by the end users. Therefore it is necessary to verify how the typical heat treating techniques affect to the aged and degraded material. As the result of experimental work in this study, GTD-111 and GTD-222 Ni-based superalloys were collected and analyzed quantitatively through microscopic observation, microhardness evaluation and creep test.

  • PDF

Cavitation Characteristics on Impeller Materials of Centrifugal Pump for Ship in Sea Water and Fresh Water (해수와 청수환경에서 선박용 원심펌프 임펠러 재료의 캐비테이션 특성)

  • Im, Myeong-Hwan
    • Corrosion Science and Technology
    • /
    • v.10 no.6
    • /
    • pp.218-224
    • /
    • 2011
  • The fresh water and sea water in present ships is used as cooling water for marine engine. Therefore, corrosion damage in seawater system is frequently occurred. In particular, in the impeller of pump, the performance and material span due to the corrosion and cavitation erosion has adverse effects. Most of the pump impellers in vessels are used Cu-Al alloy. Cu-Al alloy which having the excellent mechanical properties and corrosion resistance is widely used in marine environments. However, despite the excellent characteristics, the periodic replacement parts due to the cavitation damage in seawater is vulnerable to economic viewpoint. In this study, Cu-Al alloy used with impeller for centrifugal pump were conducted various experiments to evaluate its characteristics in seawater and fresh water solutions. As an electrochemical result, the dynamic conditions that exposed to the cavitation environment presented high corrosion current density with collapse of the cavity compared with the static conditions. Cavitation test results, the weightloss and weightloss rate in fresh water are observed more than those of seawater.

Recent Progress in Magneto-Mechano-Electric Generators (자기-기계-전기 변환소자를 이용한 에너지 하베스팅 기술)

  • Hwang, Geon-Tae;Ryu, Jungho;Yoon, Woon-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.34 no.5
    • /
    • pp.271-282
    • /
    • 2021
  • The internet of things (IoT) technology is a key component for the advent of 4th industrial revolution, which is the network of home appliances, infrastructures, and vehicles to remotely investigate these systems. For the operation of compact IoT devices, batteries are widely used as electric power, and the limited lifetime of batteries inevitably leads to periodic replacement. Magneto-mechano-electric (MME) generators may be alternatives to batteries inside the IoT devices by converting stray magnetic field into electric energy, since we are always surrounded by ambient alternating current (AC) magnetic fields induced from electric power transmission lines everywhere. This article reviews the recent domestic research progress in high-performance MME generators and their application field for IoT and electronic devices.

The Fatigue Life Evaluation of Aged Continuous Welded Rail on the Urban Railway (도시철도 장기 사용레일의 피로수명 평가)

  • Kong, Sun-Young;Sung, Deok-Yong;Park, Yong-Gul
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.821-831
    • /
    • 2013
  • As a result of recent research, it is reported that the periodic replacements criterion of rails is able to extend as grinding rail surface and using the continuous welded rail (CWR). In this study, we carried out fatigue tests on existing laid rails. Based on the test results, an S-N curve expressing the remaining life of laid rails at a fracture probability of 50% was obtained using weighted probit analysis suitable for small-sample fatigue data sets. As rails used for testing had different histories in terms of accumulated tonnage, the test data were corrected to average out the accumulated tonnage. We estimated the remaining service lives for laid rails on the urban railway using equations developed in the past to estimate rail base bending stress and that surface irregularities into consideration. Therefore, estimating the remaining service life of laid rails showed that the rail replacement period could be extended over 200 MGT, although it is necessary to remove longitudinal rail surface irregularities at welds by grinding. Also, the fatigue test results under fatigue limit, Haibach's rule appling half slope of S-N curve under the fatigue limit was considered more reasonable than modified Miner's rule for estimating rail fatigue life.