• Title/Summary/Keyword: Periodic Review

Search Result 193, Processing Time 0.04 seconds

In vitro Constructive Approaches to the Origin of Coding Sequences

  • Shiba, Kiyotaka
    • BMB Reports
    • /
    • v.31 no.3
    • /
    • pp.209-220
    • /
    • 1998
  • How did nature create the first set of genes at the beginning of life on Earth? One of the goals of molecular biology is to elucidate the fundamental rules governing how genes and, therefore, proteins were created. Through experiments carried out in the emerging field of "in vitro" or "benchtop" evolution studies, we are gaining new insights into the origins of genes and proteins as well as the origins of their functions (e.g., catalysis). In this review, I present an overview of recent experimental approaches to the question of the origin and evolution of genes. In addition, I will introduce a novel in vitro protein emergence system that was recently developed in my laboratory.

  • PDF

PD Diagnosis of Power Cables for Nuclear Power Plant (원자력발전소 전력케이블 부분방전 진단 사례)

  • Han, Sung-Heum;Joo, Kwang-Ho;Ha, Che-Wung
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.804.1-805
    • /
    • 2011
  • 1980년대 건설된 국내 원자력발전소는 30년 정도의 운전 년수를 기록하고 있다. 가동연한의 증가에 따라 원자력발전소에 설치되어 있는 전력케이블은 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV 고압케이블의 건전성을 확인하기 위하여 국내 최초 원자력발전소 운전 중 부분방전 진단을 수행하였다. 특히 측정장비별 특성 및 신뢰성을 제고하기위하여 Techimp사의 PD-Base I 장비와 OMICRON사 MPD600 장비 두가지를 가지고 케이블 부분방전(Partial Discharge; PD)열화진단을 수행 하였고 결과를 비교하였다.

  • PDF

원자력발전소에서 작업자 인터페이스의 주기적 안전성 검증 방안

  • 민유종;장통일;김수진;이용희
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2003.10a
    • /
    • pp.403-408
    • /
    • 2003
  • 현대의 산업은 대규모 공정제어 시스템을 통한 작업자와 작업자 인터페이스의 상호 유기적인 관계를 통하여 운영되고 있다. 이러한 유기적인 관계가 고신뢰도 체계를 운영하고 있는 석유화학, 군사, 통신 등의 안전성 문제에 많은 영향을 미치고 있다. 실제 대부분의 안전사고가 시스템 자체에 문제보다는 시스템을 운영하는 인간-기계 연계 체제(Human-Machine Interface; HMI)에서 비롯된 것이다. TMI, 체르노빌, JCO 등의 사고를 통하여 원자력발전소(이하, 원전)에서는 작업자 인터페이스의 품질 문제가 강조되고 있다. 이러한 노력의 일환으로 우리나라도 원전에 대한 10년 주기의 주기적안전성평가(Periodic Safety Review: PSR)에서 인적요소 평가를 포함하고 있다.(중략)

  • PDF

Study on Diagnosis of High Voltage Cables for Nuclear Power Plant (원자력발전소 고압케이블 열화진단에 관한 연구)

  • Ha, Che-Wung;Joo, Kwang-Ho;Han, Sung-Heum
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2061-2062
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있다. 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에 설치되어 있는 13.8kV급 고압케이블의 건전성을 확인하기 위하여 원자력발전소 계획예방정비 중 열화진단을 수행한 결과를 소개하고 있다. 특히 미국 NRC(Nuclear Regulatory Commission)에서는 케이블 진단 기법 11가지를 권고하고 있는데 본 논문에서는 그 중 국내 원자력발전소에 적용이 가능한 최신 케이블 진단 기술인 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정, VLF(Very Low Frequency) 장치를 이용한 $Tan{\delta}$ 측정 및 열화상카메라를 이용한 케이블 온도 측정을 사용하여 고압 케이블 진단을 실시하였고, 그 결과를 서술하였다.

  • PDF

Diagnostic Method of High Voltage Cable for Nuclear Power Plants using VLF and HFCT-PD Devices (VLF 및 HFCT-PD 장비를 이용한 원자력발전소 고압케이블 진단 방법)

  • Ha, Che-Wung;Joo, Kwang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2067-2068
    • /
    • 2011
  • 국내 원자력발전소에 설치되어 있는 고압케이블은 장기 운전에 따라 열화진단 및 유지보수의 필요성이 증대되고 있으며, 주기적 안전성 평가(Periodic Safety Review) 및 계속운전과 관련하여서도 고압케이블의 관리방안이 지속적으로 요구되고 있다. 본 논문에서는 원자력발전소에서 경년열화로 진단되어 철거된 케이블을 수거하여 VLF(Very Low Frequency) 장비를 사용하여 가압을 한 후 HFCT(High Frequency Current Transformer)를 이용한 부분방전(Partial Discharge ; PD) 측정을 수행하여 향후 원자력발전소 계획예방정비 시 케이블을 대상으로 Off-line 부분 방전 진단이 가능한지를 검토하였고, 그 결과를 기술하였다.

  • PDF

A Study on Management Body Consciousness for Managing Facility Safety Inspection and Diagnosis (시설물 안전 점검 및 진단 실시에 대한 관리주체 의식에 관한 연구)

  • Kim, Hak-Eung;Jung, Soo-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.19-27
    • /
    • 2008
  • Since 1995, the facility of class 1 and 2, classified by law had been subject to system of post maintenance management where periodic safety inspection and diagnosis to identify any problems and to take appropriate measures as a matter of urgency. Although the standards and systems had been revised many times for continuous improvement due to surrounding environmental factors, the technical factors and other factors for improvements, continuous researches and efforts are needed to ensure even higher effectiveness. Furthermore, the consciousness of the management body that executes and implements such improvements for facility management is most important. Therefore in this study, through such analysis, more realistic management consciousness review was performed. Also the direction for improvements is proposed, to carry out more effective facility safety management systems implementation.

Stellar Photometric Variability in the Open Cluster M37 Field on Time-Scales of Minutes to Days

  • Chang, Seo-Won;Byun, Yong-Ik
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.1
    • /
    • pp.58.1-58.1
    • /
    • 2012
  • We present a comprehensive re-analysis of stellar photometric variability in the field of open cluster M37, using our new high-precision light curves. This dataset provides a rare opportunity to explore different types of variability between short (-minutes) and long (-one month) time-scales. To investigate the variability properties of -30,000 objects, we developed new algorithms for detecting periodic, aperiodic, and sporadic variability in their light curves. About 7.5% (2,284) of the total sample exhibits convincing variations that are induced by flares, pulsations, eclipses, starspots and, in some cases, unknown causes. The benefits of our new photometry and analysis package are evident. The discovery rate of new variables is increased by 63% in comparison with the existing catalog of variables, and 51 previously identified variables were found to be false positives resulting from time-dependent systematic effects. Based on extended and improved catalog of variables, we will review the basic properties (e.g., periodicity, amplitude, type) of the variability and how different they are for different spectral types and for cluster memberships.

  • PDF

Cs-137 distribution around Kori Nuclear Power Plant

  • Lee, H.;Kang, H.S.;Choi, H.J.;Yu, D.H.;Lim, K.M.;Choi, Y.H.
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.4
    • /
    • pp.349-351
    • /
    • 2003
  • To ensure the safety of the currently operating nuclear power plant, the Periodic Safety Review program has been conducted. In PSR program, the cumulative behavior of the radionuclide that might be released from the power plant is addressed. The Cs-137 in soil around Kori nuclear power plant was investigated. The soil sample was analyzed and compared with the reference area. The model calculation explained the depth profile of Cs-137.

BENT함수와 bent 수열을 중심으로 본 상관성이 우수한 수열군

  • 정하봉
    • Review of KIISC
    • /
    • v.2 no.3
    • /
    • pp.41-49
    • /
    • 1992
  • 레이다 시스템, ranging 시스템, 확산 대역 통신 (spread spectrum communication) 시스템, 그리고 요즈음 각광받고 있는 코드분할방식 다중통신 (CDMA com-munication) 시스템에서는 주지하다시피 상관성(correlation) 이 좋은 수열(sequence)들위 사용이 필수 불가결하다. 수열의 상관성은 그 수열 자신의 상관성이냐 다른 수열간의 상관성이냐에 따라 자기상관관계(crosscorrelation)로 나누어 생각할 수 있고 수열의 주기성의 유무에 따라 주기적 상관관계(Periodic correlation)와 비주기적 상관관계(aperiodic correla-tion)로 나누어 볼 수 있다. 여기서 수열의 상관성이 좋다는 말은 정규화된 수열의 자기상관계수(autocorrelation coefficient)와 수열 간의 교차상관 계수(crosscorrelation coefficient)의 최대 크기가 수열의 길이에 비해 상대적으로 작은 값을 갖는다는 것을 의미한다. 본 논문에서는 주기성을 갖는 이진수열군의 하나인 bent수열과 이 bent수열을 구성하는데 기본이 되는 bent함수를 중심으로 주기적 상관성이 우수한 여러 수열군에 대해 알아보고자 한다.

  • PDF

Actinomycosis of the Foot - A Case report - (족부에 발생한 방선균증 - 1예 보고 -)

  • Kim, Chong-Kwan;Kim, Jeong-Whan;Hong, Jeong-Gee;Kwon, Oh-Joon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.1
    • /
    • pp.30-34
    • /
    • 2000
  • The Actinomyces organism is inherent in human as normal flora found in the mouth. Outside of the mouth, this organism can cause actinomycosis. Involvement of the extremity is very rare and atypical. The authors have experienced a case of actinomycosis of the foot and report with the literature review. Histopathologic finding shows multiple sulfur granules. In histochemical stains, periodic acid-Schiff, Gomori methionine silver, and gram stain were positive, and acid fast bacilli stain was negative. The patient was treated with surgical excision and antibiotic administration with Ampicillin for 6 months.

  • PDF