• Title/Summary/Keyword: Perimeter

Search Result 493, Processing Time 0.025 seconds

The Effect of Perimeter on Characteristics of Frequency-Agile Tunable Capacitors

  • Lee, Young Chul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.561-563
    • /
    • 2012
  • In this work, tunable capacitors using a finger-type electrode are designed and characterized for frequency-agile RF circuit applications. Their top electrodes with different area and line width are designed in types of the finger for a long conducting perimeter which results in enhanced fringing-electric fields in order to improve their tunability. The tunable varactors were fabricated on a quartz substrate employing a multi-layer dielectric of a para/ferro/para-electric thin film. Compared to the conventional capacitor, finger-type capacitors are characterized in terms of effective capacitance and tunablility. Their effective capacitance and tunability with the long perimeter increase 24~40% and 7~12%, respectively, due to enhanced fringing electric fields from 1 to 2.5 GHz, compared to the conventional ones.

  • PDF

Seismic Isolation Systems Incorporating with RC Core Walls and Precast Concrete Perimeter Frames -Shimizu Corporation Tokyo Headquarter-

  • Shimazaki, Dai;Nakagawa, Kentaro
    • International Journal of High-Rise Buildings
    • /
    • v.4 no.3
    • /
    • pp.181-189
    • /
    • 2015
  • Shimizu Corporation Tokyo Headquarters, one of the city's leading office buildings, features many pioneering technologies that contribute to a sustainable society through environmental stewardship and a sophisticated disaster management facility. In terms of structural engineering, a seismic isolation system incorporating reinforced concrete core walls and precast concrete perimeter frames create a robust structure in the event of a large earthquake. In addition to the seismic resistance of the structure, several pioneering construction methods and materials are adopted. This office building can serve as a basis for new design and construction approaches and methodologies to ensure safe and economical structures.

Study on Development of Light Duct System for Perimeter Occupied Zone on Underground Space (지하대공간에 있어 Perimeter Occupied Zone에 대한 채광덕트 시스템 개발에 관한 연구)

  • 김회서;이성주
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.13 no.4
    • /
    • pp.21-26
    • /
    • 1999
  • Using daylight in underground spoce may significantly reduce electric lighting load and give a visually comfortable environment. This reper describes a fundaIrentaI study on light duct system to predict inter illuminance ratio on underground periIreter occupied zone level. As a result, integral equation for inter-reflection program are developed and by using optimize light duct system can gives daylight on deep underground space. space.

  • PDF

Integral formulas for strips

  • Kim, Yong-Il
    • Communications of the Korean Mathematical Society
    • /
    • v.12 no.4
    • /
    • pp.985-998
    • /
    • 1997
  • For n random strips chosen so as to meet a fixed bounded convex set K of the plane we let $\nu$ be the number of intersection regions that meet K. We develop the integral formula for the mean value of $\nu$ and $\nu^2$ involving the area and the perimeter of K and the breadths of the strips. We get some geometric inequalities in way of studying integral geometry.

  • PDF

VARIOUS CENTROIDS OF QUADRILATERALS WITHOUT SYMMETRY

  • Kim, Incheon;Kim, Dong-Soo
    • Journal of the Chungcheong Mathematical Society
    • /
    • v.33 no.4
    • /
    • pp.429-444
    • /
    • 2020
  • For a quadrilateral P, we consider the centroid G0 of the vertices of P, the perimeter centroid G1 of the edges of P and the centroid G2 of the interior of P, respectively. It is well known that P satisfies G0 = G1 or G0 = G2 if and only if it is a parallelogram. In this paper, we investigate various quadrilaterals satisfying G1 = G2. As a result, we establish some characterization theorems. One of them asserts the existence of convex quadrilaterals satisfying G1 = G2 without symmetry.

An Enhanced Greedy Message Forwarding Protocol for Increasing Reliability of Mobile Inter-Vehicle Communication (이동하는 차량 간 통신의 신뢰성 향상을 위한 개선된 탐욕 메시지 포워딩 프로토콜)

  • Ryu, Min-Woo;Cha, Si-Ho;Cho, Kuk-Hyun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.4
    • /
    • pp.43-50
    • /
    • 2010
  • Vehicle-to-Vehicle (V2V) is a special type of vehicle ad-hoc network (VANET), and known as a solution to provide communication among vehicles and reduce vehicle accidents. Geographical routing protocols as Greedy Perimeter Sateless Routing (GPSR) are very suitable for the V2V communication due to special characters of highway and device for vehicles. However, the GPSR has problem that appears local maximum by some stale neighbor nodes in the greedy mode of the GPSR. It can lose transmission data in recovery mode, even if the problem is can be solved by the recovery mode of the GPSR. We therefore propose a Greedy Perimeter Reliable Routing (GPRR), can provide more reliable data transmission, to resolve the GPSR problem in the V2V environment. Simulation results using ns-2 shown that the GPRR reveals much better performance than the GPSR by remarkably reducing the local maximum rate in the greedy mode.

A Study on Perimeter Load Transfer Fuctions of the Large Diameter Drilled Shafts Depending on Soil Types During the Static Pile Load Tests (정재하시험시 지반종류별 대구경 현장타설말뚝의 주면하중전이함수에 관한 연구)

  • Jung, Ho-Young;Hwang, Seong Chun;Choi, Yongkyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.5C
    • /
    • pp.163-170
    • /
    • 2011
  • Perimeter load transfer functions were developed by an analysis of the static pile load test results of the 7 large diameter drilled shafts constructed in domestic areas. Using the pile axial load distributions obtained from the static pile load tests of large diameter drilled shafts, the unit skin frictions were analyzed and, based on unit skin friction test data, perimeter load transfer functions could be suggested. The load transfer distributions calculated by suggested functions and the load transfer functions obtained from the bi-directional pile load tests were compared. As a result, the 2 load transfer distributions were coincided, respectively.

Quantitative Analysis of Lower Nose and Upper Lip Asymmetry in Patient with Unilateral Cleft Lip Nose Deformity using 3D camera (3D camera를 이용한 일측성 구순비변형환자에서의 비하부 및 상구순 비대칭의 정량적 분석)

  • Oh, Tae suk;Koh, Kyung suk;Kim, Tae gon
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.702-706
    • /
    • 2009
  • Purpose: Analysis of lower nose and upper lip asymmetry in patients with unilateral cleft lip nose deformity has been proceeded through direct measurement and photo analysis. But there are limitation in presenting real image because of its 2 dimensional trait. The authors analyzed such an asymmetry using 3D VECTRA system (Canfield, NJ, USA) in quantitative way. Methods: In 25 Patients with unilateral cleft lip nose deformity(male 12, female 13, age ranging from 4 to 19), patients with right side deformity were 10 and left were 15. Analysis of asymmetry was proceeded through 3D VECTRA system. After taking 3 dimensional photo, alar area, upper lip area, nostril perimeter, nostril area, Cupid's bow length, nostril height and nostril width were measured. Correlation coefficient and inter data quotients were calculated. Results: In nostril perimeter, maximal difference of cleft side and non - cleft side was 39.3%, asymmetric quotient Qasy = Qcl/Qncl(Qcl, value of cleft side; Qncl, value of non - cleft side) was ranged from 0.84 to 1.85 and in seven cases the length of cleft side was smaller. In nostril area, maximal difference was 69.6% and in 13 cases cleft side was smaller. In lower nasal area, maximal difference was 37.2% asymmetric quotient Qasy = Qcl/Qncl was ranged from 0.47 to 2.03 and in 20 cases cleft side was smaller. The correlation coefficients of nostril perimeter and area were 0.8345. Conclusion: Using 3D VECTRA system, the authors can measure nostril perimeter and lower nasal area that could not been measured with previous methods. Asymmetry of midface was analyzed through area comparison in quantitative way. Futhermore, post operative change can be measured in quantitative method.

Evaluation of Indoor Thermal Environment According to Air-Barrier Air Conditioning System in Perimeter Zone (페리미터존의 에어배리어 공조방식에 따른 실내 열환경 평가)

  • Park Byung-Yoon;Ham Heung-Don;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.4
    • /
    • pp.370-376
    • /
    • 2005
  • For the purpose of investigating the effective removal of heating/cooling load from light-weighted building envelope, two air-conditioning systems, conventional parameter air-conditioning system and air-barrier system, are evaluated and compared by both experiment and simulation with six different cases during heating and cooling season. In addition, the characteristics of window-side building thermal load are assessed by varying supply air velocity in order to seek the optimal system operation condition. The results are as follows. 1) Air-barrier system is more effective to remove heating/cooling load at perimeter zone than conventional parameter air-conditioning system. Moreover, the better effectiveness appears during cooling season than during heating season. 2) The experiment during cooling season provides that indoor temperature of air-barrier system shows $1^{\circ}C$ less than that of the conventional system with similar outdoor air temperature profile, and indoor temperature distribution is more uniform throughout the experimented model space. It concludes that air-barrier system can achieve energy saving comparing to the conventional system. 3) The capturing efficiency of air-barrier system is 0.47 on heating season and 0.2 on cooling season with the same supply air volume. It results that the system performs effectively to remove building thermal load, moreover demonstrates high efficiency during cooling season. 4) The simulation results provide that capturing efficiency to evaluate the effective removal of building load from perimeter zone shows high value when supply air velocity is 1 m/s.

Thermo-mechanical Behavior of Wire Bonding PBGA Packages with Different Solder Ball Grid Patterns (Wire Bonding PBGA 패키지의 솔더볼 그리드 패턴에 따른 열-기계적 거동)

  • Joo, Jin-Won
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.2
    • /
    • pp.11-19
    • /
    • 2009
  • Thermo-mechanical behaviors of wire-bond plastic ball grid array (WB-PBGA) package assemblies are characterized by high-sensitivity moire interferometry. Using the real-time moire setup, fringe patterns are recorded and analyzed for several temperatures. Experiments are conducted for three types of WB-PBGA package that have full grid pattern and perimeter pattern with/without central connections. Bending deformations of the assemblies and average strains of the solder balls are investigated, with an emphasis on the effect of solder interconnection grid patterns, Thermal strain distributions and the location of the critical solder ball in package assemblies are quite different with the form of solder ball grid pattern. For the WB-PBGA-PC, The largest of effective strain occurred in the inner solder ball of perimeter closest to the chip solder balls. The critical solder ball is located at the edge of the chip for the WB-PBGA-FG, at the most outer solder ball of central connections for the WB-PBGA-P/C, and at the inner solder ball closest to the chip for the WB-PBGA-P.

  • PDF