• Title/Summary/Keyword: Peri-implant bone loss

Search Result 75, Processing Time 0.025 seconds

A new classification of periodontal and peri-implant disease (치주질환 및 임플란트 주위 질환의 새 분류)

  • Shin, Hyun-Seung
    • The Journal of the Korean dental association
    • /
    • v.57 no.12
    • /
    • pp.758-767
    • /
    • 2019
  • The classification of periodontal disease in 1999 has been widely used for determining a diagnosis, establishing a treatment plan, and evaluating the prognosis of the patient with periodontal disease. However, scientific evidence from many studies indicates the need for a new classification system for periodontal and peri-implant disease. Summary at 2017 world workshop as follows: 1) Periodontal health and peri-implant health was defined; 2) Chronic periodontitis and aggressive periodontitis were unified as periodontitis; 3) Periodontitis was further classified by staging and grading to reflect disease severity and management complexity, rate of disease progression, respectively; 4) Periodontal disease as manifestation of systemic disease is based on the International Statistical Classification of Diseases and Related Health Problems-10 (ICD-10) code; 5) Periodontal biotype and biologic width was replaced to periodontal phenotype and supracrestal tissue attachment, respectively; 6) The excessive occlusal force was replaced by a traumatic occlusal force; 7) ≥3 mm of radiographic bone loss, ≥6 mm of pocket probing depth and bleeding on probing indicates peri-implantitis in the absence of radiograph at final prosthesis delivery.

  • PDF

Randomized controlled clinical trial of 2 types of hydroxyapatite-coated implants on moderate periodontitis patients

  • Kim, Hyun-Suk;Yun, Pil-Young;Kim, Young-Kyun
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.5
    • /
    • pp.337-349
    • /
    • 2016
  • Purpose: The aim of this study was to compare and analyze the peri-implant tissue conditions and prospective clinical outcomes associated with 2 types of hydroxyapatite (HA)-coated implants: (1) fully HA-coated implants and (2) partially HA-coated implants with resorbable blast medium on the coronal portion of the threads. Methods: Forty-four partially edentulous patients were randomly assigned to undergo the placement of 62 HA-coated implants, and were classified as the control group (partially HA-coated, n=30) and the test group (fully HA-coated, n=32). All patients had chronic periodontitis with moderate crestal bone loss around the edentulous area. The stability and clinical outcomes of the implants were evaluated using the primary and secondary implant stability quotient (ISQ), as well as radiographic, mobility, and peri-implant soft tissue assessments around the implants. The Wilcoxon signed-rank test and the Mann-Whitney test were used to evaluate differences between and within the 2 groups, with P values <0.05 considered to indicate statistical significance. Results: The fully HA-coated implants displayed good retention of crestal bone, and insignificant differences were found in annual marginal bone loss between the 2 types of HA-coated implants (P>0.05). No significant differences were found in the survival rate (group I, 100%; group II, 100%) or the success rate (group I, 93.3%; group II, 93.8%). The fully HA-coated implants also did not significantly increase the risk of peri-implantitis (P>0.05). Conclusions: The fully HA-coated implants did not lead to an increased risk of peri-implantitis and showed good retention of the crestal bone, as well as good survival and success rates. Our study suggests that fully HA-coated implants could become a reliable treatment alternative for edentulous posterior sites and are capable of providing good retention of the crestal bone.

The influence of Collar design on peri-implant marginal bone tissue (Collar design이 임플랜트 주위 변연골 흡수에 미치는 영향)

  • Kim, Jee-Hwan;Jung, Moon-Kyou;Moon, Hong-Suk;Han, Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.1
    • /
    • pp.53-64
    • /
    • 2008
  • Statement of problem: Peri-implant marginal bone loss is an important factor that affects the success of implants in esthetics and function. Various efforts have been made to reduce this bone loss by improving implant design and surface texture. Previous studies have shown that early marginal bone loss is affected by implant neck designs. Purpose: The purpose of this study was to examine the influence of laser microtexturing of implant collar on peri-implant marginal bone loss. Materials and methods: Radiographical marginal bone loss was examined in patients treated with implant-supported fixed partial dentures. Marginal bone level was examined with 101 implant fixtures installed in 53 patients at three periods(at the time of implantation, prosthetic treatment and 6-month after loading). Four types of implants were examined. The differences of bone loss between implants(ITI standard) with enough biologic width and implants(ITI esthetic plus, Silhouette IC, Silhouette IC Laser-$Lok^{TM}$) with insufficient biologic width have been compared. Resorption angles were examined at the time of prosthetic delivery and 6-month after loading. Results and Conclusion: Within the limitation of this study, the following results were drawn. 1. The marginal bone loss of ITI standard and Silhouette IC Laser-$Lok^{TM}$ was less than that of ITI esthetic plus and Silhouette IC(P<0.05). The marginal bone loss between ITI standard and Silhouette IC Laser-$Lok^{TM}$ had no significant statistical difference(P>0.05). There was no significant statistical difference between marginal bone loss of ITI esthetic plus and Silhouette IC(P>0.05). 2. There was no significant difference in marginal bone loss between maxilla and mandible(P>0.05). 3. There was no significant difference in resorption angle among four types of implants(P>0.05). The marginal bone of implants with supracrestal collar design of less than that of biologic width had resorbed more than those with sufficient collar length. The roughness and laser microtexturing of implant neck seem to affect these results. If an implant with collar length of biologic width, exposure of fixture is a possible complication especially in the anterior regions of dentition that demand high esthetics. Short smooth neck implant are often recommended in these areas which may lack the distance between microgap and the marginal bone level. In these cases, the preservation of marginal bone must be put into consideration. From the result of this study, it may be concluded that laser microtexturing of implant neck is helpful in the preservation of marginal bone.

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.

Influence of implant-abutment connection structure on peri-implant bone level in a second molar: A 1-year randomized controlled trial

  • Kim, Jin-Cheol;Lee, Jungwon;Kim, Sungtae;Koo, Ki-Tae;Kim, Hae-Young;Yeo, In-Sung Luke
    • The Journal of Advanced Prosthodontics
    • /
    • v.11 no.3
    • /
    • pp.147-154
    • /
    • 2019
  • PURPOSE. This study aimed to evaluate the effect of two different implant-abutment connection structures with identical implant design on peri-implant bone level. MATERIALS AND METHODS. This clinical study was a patient-blind randomized controlled trial following the CONSORT 2010 checklists. This trial was conducted in 24 patients recruited between March 2013 and July 2015. Implants with internal friction connection were compared to those with external hex connection. One implant for each patient was installed, replacing the second molar. Implant-supported crowns were delivered at four months after implant insertion. Standardized periapical radiographs were taken at prosthesis delivery (baseline), and one year after delivery. On the radiographs, distance from implant shoulder to first bone-to-implant contact (DIB) and peri-implant area were measured, which were the primary and secondary outcome, respectively. RESULTS. Eleven external and eleven internal implants were analyzed. Mean changes of DIB from baseline to 1-year postloading were 0.59 (0.95) mm for the external and 0.01 (0.68) mm for the internal connection. Although no significant differences were found between the two groups, medium effect size was found in DIB between the connections (Cohen's d = 0.67). CONCLUSION. Considering the effect size in DIB, this study suggested the possibility of the internal friction connection structure for more effective preservation of marginal bone.

Unusual bone regeneration following resective surgery and decontamination of peri-implantitis: a 6-year follow-up (임플란트주위염의 삭제형 골수술 후 골재생 증례보고: 6년 추적관찰)

  • Kim, Hyun-Joo;Lee, Ju-Youn
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.38 no.3
    • /
    • pp.171-177
    • /
    • 2022
  • Peri-implantitis is an inflammatory lesion of the periodontium surrounding an endosseous implant, with progressive loss of the supporting peri-implant bone. The main purposes of treatment for peri-implantitis due to biological factors include addressing the inflammation and restoring a healthy but reduced periodontium around the implant, similar to the treatment of periodontitis in natural teeth. The proposed treatment protocol includes surgical treatment, mainly resective surgery, after non-surgical treatment such as oral hygiene instructions, mechanical cleansing of the fixture, and general or topical antiseptic or antibiotic application according to the extent of inflammation. In this article, we present a 6-year follow-up case showing unusual marginal bone regeneration after resective surgery and decontamination of an implant surface for the treatment of peri-implantitis and discuss the possible reasons.

Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

  • Kim, Jun Ho;Abdala-Junior, Reinaldo;Munhoz, Luciana;Cortes, Arthur Rodriguez Gonzalez;Watanabe, Plauto Christopher Aranha;Costa, Claudio;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.133-139
    • /
    • 2020
  • Purpose: This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mechanically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods: Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm×8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm×8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results: High intraobserver and interobserver agreement was found (P<0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56±0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion: Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss.

Implant success rates in full-arch rehabilitations supported by upright and tilted implants: a retrospective investigation with up to five years of follow-up

  • Francetti, Luca;Rodolfi, Andrea;Barbaro, Bruno;Taschieri, Silvio;Cavalli, Nicolo;Corbella, Stefano
    • Journal of Periodontal and Implant Science
    • /
    • v.45 no.6
    • /
    • pp.210-215
    • /
    • 2015
  • Purpose: The aim of this retrospective study was to investigate the cumulative success rate, the implant survival rate, and the occurrence of biological complications in implants supporting full-arch immediately loaded rehabilitations supported by upright and tilted implants. Methods: The clinical records and periapical radiographs of patients who attended follow-up visits were collected, and information was recorded regarding marginal bone loss resorption, the occurrence of peri-implant infectious diseases, and the implant survival rate. Implants were classified as successful or not successful according to two distinct classifications for implant success. Results: A total of 53 maxillary and mandibular restorations including 212 implants were analysed, of which 56 implants were studied over the full five-year follow-up period. After five years, the cumulative success rate was 76.04% according to the Misch classification and 56.34% according to the Albrektsson classification. The cumulative implant survival rate was 100%, although one implant was found to be affected by peri-implantitis at the second follow-up visit. Conclusions: The cumulative success rate of the implants dropped over time, corresponding to the progression of marginal bone resorption. The prevalence of peri-implantitis was very low, and the implant survival rate was not found to be related to the cumulative success rate.

Preliminary evaluation of a three-dimensional, customized, and preformed titanium mesh in peri-implant alveolar bone regeneration

  • Jung, Gyu-Un;Jeon, Jae-Yun;Hwang, Kyung-Gyun;Park, Chang-Joo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.4
    • /
    • pp.181-187
    • /
    • 2014
  • Objectives: The purpose of this preliminary study is to evaluate the effectiveness of a customized, three-dimensional, preformed titanium mesh as a barrier membrane for peri-implant alveolar bone regeneration. Materials and Methods: Ten patients were recruited for this study. At the time of implant placement, all patients had fenestration or a dehiscence defect around the implant fixture. A mixture of particulate intraoral autologous bone and freeze-dried bone allograft was applied to the defect in a 1 : 1 volume ratio and covered by the preformed titanium mesh. A core biopsy specimen was taken from the regenerated bone four months postoperatively. Patients were followed for 12 months after the definitive prosthesis was placed. Results: Satisfactory bone regeneration with limited fibrous tissue was detected beneath the preformed titanium mesh. Histologic findings revealed that newly formed bones were well-incorporated into the allografts and connective tissue. New growth was composed of approximately 80% vital bone, 5% fibrous marrow tissue, and 15% remaining allograft. All implants were functional without any significant complications. Conclusion: The use of preformed titanium mesh may support bone regeneration by maintaining space for new bone growth through its macro-pores. This preliminary study presents the efficacy of a preformed titanium mesh as a ready-to-use barrier membrane around peri-implant alveolar bone defect. This preformed mesh is also convenient to apply and to remove.

Risk indicators for mucositis and peri-implantitis: results from a practice-based cross-sectional study

  • Rinke, Sven;Nordlohne, Marc;Leha, Andreas;Renvert, Stefan;Schmalz, Gerhard;Ziebolz, Dirk
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.3
    • /
    • pp.183-196
    • /
    • 2020
  • Purpose: This practice-based cross-sectional study aimed to investigate whether common risk indicators for peri-implant diseases were associated with peri-implant mucositis and peri-implantitis in patients undergoing supportive implant therapy (SIT) at least 5 years after implant restoration. Methods: Patients exclusively restored with a single implant type were included. Probing pocket depth (PPD), bleeding on probing (BOP), suppuration, and radiographic bone loss (RBL) were assessed around implants. The case definitions were as follows: peri-implant mucositis: PPD ≥4 mm, BOP, no RBL; and peri-implantitis: PPD ≥5 mm, BOP, RBL ≥3.5 mm. Possible risk indicators were compared between patients with and without mucositis and peri-implantitis using the Fisher exact test and the Wilcoxon rank-sum test, as well as a multiple logistic regression model for variables showing significance (P<0.05). Results: Eighty-four patients with 169 implants (observational period: 5.8±0.86 years) were included. A patient-based prevalence of 52% for peri-implant mucositis and 18% for peri-implantitis was detected. The presence of 3 or more implants (odds ratio [OR], 4.43; 95 confidence interval [CI], 1.36-15.05; P=0.0136) was significantly associated with an increased risk for mucositis. Smoking was significantly associated with an increased risk for peri-implantitis (OR, 5.89; 95% CI, 1.27-24.58; P=0.0231), while the presence of keratinized mucosa around implants was associated with a lower risk for peri-implantitis (OR, 0.05; 95% CI, 0.01-0.25; P<0.001). Conclusions: The number of implants should be considered in strategies to prevent mucositis. Furthermore, smoking and the absence of keratinized mucosa were the strongest risk indicators for peri-implantitis in patients undergoing SIT in the present study.