• Title/Summary/Keyword: Performance test for nuclear instrumentation

Search Result 12, Processing Time 0.016 seconds

Electromagnetic Interference Test Result Analysis of Integral Reactor Digital I&C System (일체형 원자로 디지털 계측제어계통 전자파 장애 시험결과 분석)

  • Lee, Joon-Koo;Sohn, Kwang-Young;Park, Hee-Seok;Park, Heui-Yun;Koo, In-Soo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.213-218
    • /
    • 2003
  • Because of the development of digital technology, modern digital instrumentation & control systems are being innovativly developed in industrial plants. Whereas, many analog systems are still being used in nuclear plants, because of the demerits of digital equipment. As known, the demerits of digital equipment are the uncertainty and weaknesses in ambient environments such as smoke & electromagnetic interference In an Integral Reactor, a digital I&C system will be composed of microprocessor, memory and network card. Designers will apply new technique for digital equipment. Thus, it is important for digital I&C systems to operate according to designed functions & performance in the ambient environments during a life cycle. Digital I&C systems should have tolerance in such environments and environment qualification should be concluded To acquire electromagnetic interference qualification of digital equipment, this paper suggests an EMI test requirement. Designers should consider the electromagnetic compatibility and test digital equipment according to each test procedure. This paper involves an EMI test requirement and the results analysis of EUT(Equipment Under Test). Test result analysis will be used as electromagnetic compatibility design guides for Integral Reactor I&C systems.

  • PDF

DEVELOPMENT OF RPS TRIP LOGIC BASED ON PLD TECHNOLOGY

  • Choi, Jong-Gyun;Lee, Dong-Young
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.697-708
    • /
    • 2012
  • The majority of instrumentation and control (I&C) systems in today's nuclear power plants (NPPs) are based on analog technology. Thus, most existing I&C systems now face obsolescence problems. Existing NPPs have difficulty in repairing and replacing devices and boards during maintenance because manufacturers no longer produce the analog devices and boards used in the implemented I&C systems. Therefore, existing NPPs are replacing the obsolete analog I&C systems with advanced digital systems. New NPPs are also adopting digital I&C systems because the economic efficiencies and usability of the systems are higher than the analog I&C systems. Digital I&C systems are based on two technologies: a microprocessor based system in which software programs manage the required functions and a programmable logic device (PLD) based system in which programmable logic devices, such as field programmable gate arrays, manage the required functions. PLD based systems provide higher levels of performance compared with microprocessor based systems because PLD systems can process the data in parallel while microprocessor based systems process the data sequentially. In this research, a bistable trip logic in a reactor protection system (RPS) was developed using very high speed integrated circuits hardware description language (VHDL), which is a hardware description language used in electronic design to describe the behavior of the digital system. Functional verifications were also performed in order to verify that the bistable trip logic was designed correctly and satisfied the required specifications. For the functional verification, a random testing technique was adopted to generate test inputs for the bistable trip logic.