• 제목/요약/키워드: Performance response program

검색결과 359건 처리시간 0.027초

상품라인별 가격결정이 적재효율 및 물류비에 미치는 영향에 관한 연구 (Study on the Effect of Product Line Pricing on Loading Efficiency and Logistics Cost)

  • 정성태;윤남수;한규철
    • 유통과학연구
    • /
    • 제12권8호
    • /
    • pp.55-69
    • /
    • 2014
  • Purpose - Despite the importance of price, many companies do not implement pricing policies smoothly, because typical price management strategies insufficiently consider logistics efficiency and an increase in logistics costs due to logistics waste. This study attempts to examine the effect of product line pricing, which corresponds to product mix pricing, on logistics efficiency in the case of manufacturer A, and analyzes how logistics performance changes in response to these variables. Research design, data, and methodology - This study, based on the case of manufacturer A, involved research through understanding the current status, analyses, and then proposing improvement measures. Among all the products of manufacturer A, product group B was selected as the research object, and its distribution channel and line pricing were examined. As a result of simulation, for products with low loading efficiency, improvement measures such as changing the number of bags in the box were suggested, and a quantitative analysis was conducted on how these measures influence logistics costs. The TOPS program was used for the Pallet loading efficiency simulation tool in this study. To prevent products from protruding out of the pallet, the maximum measurement was set as 0.0mm, and loading efficiency was based on the pallet area, and not volume. In other words, its size (length x width) was focused upon, following the purpose of this study and, then, the results were obtained. Results - As a result of the loading efficiency simulation, when the number of bags in the box was changed for 36 products with low average loading efficiency of 73.7%, as shown in

    , loading efficiency improved to 89.9%. Further, from calculating logistics cost based on the cost calculation standard of manufacturer A, the amount of annual logistics cost reduction amounted to 101,458,084 KRW. Given that the sum of the logistics cost of the product group B of manufacturing enterprises A is 400,340,850 KRW, it can be reduced by 25%, to 298,882,766 KRW. Although many methods improve loading efficiency, this study proved that logistics cost could be reduced by changing the number of bags within boxes. If this measure is applied to other items, visible logistics cost reduction effects will be realized through improvements in loading efficiency. Conclusions - Future pricing policies should consider their correlation with quality, loading efficiency, product specifications, and logistics standardization to prevent logistics waste, enabling management to improve earnings for companies. Thus, when companies decide pricing policies for new products, the aspects of merchandising and marketing should take priority; however, the aspect of logistics also needs to be considered as significant. Measures revealed by the study results are not only the responsibilities of manufacturing enterprises. Pricing policy agreements between manufacturing enterprises and distribution companies, and logistics factors related to price determination should be considered; further, governments should also support them for their collaborations. This will enable consumers to purchase quality products with low prices.

  • 금속선이 삽입된 추진제 그레인의 Burn-back 해석 (Burn-back Analysis for Propellant Grains with Embedded Metal Wires)

    • 이현섭;오종윤;양희성;이선영;길태옥
      • 한국추진공학회지
      • /
      • 제26권2호
      • /
      • pp.12-19
      • /
      • 2022
    • 금속선이 삽입된 추진제 그레인은 높은 충전율을 유지하면서 연소속도를 증가시키기 위해 사용되어왔다. 금속선이 삽입된 추진제 그레인을 사용하는 추진기관의 성능설계를 위해서는 금속선의 위치, 개수, 배치각도, 금속선에서의 추진제 연소속도 증가비에 따른 burn-back 해석이 요구된다. 본 연구에서는 금속선이 삽입된 추진제 그레인의 설계변경에 대응하여 신속하게 연소면적을 계산할 수 있는 수치적 방법이 개발되었다. 개발된 방법과 CAD 프로그램으로부터 도출된 연소면적 결과를 비교하였으며, 격자의 반경방향 크기가 줄어들수록 오차율이 줄어드는 것을 확인 했다. 금속선의 개수 및 위치변경에 따른 영향성 분석이 수행되었으며, 금속선의 개수가 증가하면 연소초기 및 말기 구간이 짧아지고 정상상태구간이 길어지는 것이 확인되었다. 금속선을 배치할 때, 서로 다른 반경에 금속선을 배치하는 경우에서 동일한 반경에 금속선을 배치하는 경우보다 연소초기 영역에서의 연소면적이 급증하고 연소말기에서 연소면적이 급감하는 것이 확인되었다.

    탄성계수 감소곡선에 근거한 철도노반의 회복탄성계수 모델 개발 및 평가 (Development and Assessment for Resilient Modulus Prediction Model of Railroad Trackbeds Based on Modulus Reduction Curve)

    • 박철수;황선근;최찬용;목영진
      • 대한토목학회논문집
      • /
      • 제29권2C호
      • /
      • pp.71-79
      • /
      • 2009
    • 본 연구에서는 국내 철도 토공노반 재료로 가장 흔히 사용되는 입도조정쇄석, 화강풍화토, 암버럭-토사 혼합 재료에 대해 평균유효주응력과 축변형률의 함수로 표현되는 회복탄성계수 예측모델을 결정하였다. 회복탄성계수 예측모델은 대표적인 동적물성치인 변형률에 따른 전단탄성계수 감소곡선의 표현과 같이 최대영탄성계수와 정규화 영탄성계수 감소곡선으로 구성된다. 평균유효주응력의 함수로 표현되는 최대영탄성계수의 모델인자는 $A_E$$n_E$이고, 비선형 영역의 정규화 영탄성계수 감소곡선은 기준변형률(${\varepsilon}_r$)과 곡률계수(a)를 모델인자로 하는 수정 쌍곡선 모델로 표현된다. 제안된 회복탄성계수 예측모델을 검증하기 위해 3차원 다층탄성해석 프로그램(GEOTRACK)을 이용하여 평택 시험 철도노반의 탄성거동을 평가하였고, 화물열차 및 여객열차가 시험구간을 통과할 때 계측한 노반의 수직 탄성변위와 비교하였다. 현장계측은 자갈도상 아래의 재료가 각각 입도조정쇄석과 양질의 화강풍화토인 두 개소에서 수행되었다. 자갈도상 아래에서 계산된 수직 탄성변위는 대략 0.6mm 이내였고 계측 결과와 잘 일치하였다. 본 연구를 통해 제안된 회복탄성계수 예측모델이 열차하중에 의한 노반의 탄성거동을 적절히 표현하고 있음을 확인하였다.

    기능성화장품 선택속성의 IPA(중요도-만족도) 분석 (Importance-Performance Analysis(IPA) of the selection attributes of functional cosmetics)

    • 한도경;이현준;백현동;신동규;박대섭;황혜선;홍완수
      • 한국산학기술학회논문지
      • /
      • 제17권6호
      • /
      • pp.527-536
      • /
      • 2016
    • 본 연구는 국내 소비자들을 대상으로 기능성화장품 선택속성 항목의 중요도와 만족도를 실시하여 소비자들이 중요하게 생각하지만 만족도가 낮은 항목, 개선점 등을 분석하여 기능성화장품 개발 시 소비자들의 요구를 반영함으로써 화장품 시장에서의 경쟁력을 확보하고 판매 및 홍보활성화를 위한 기초자료를 제공하고자 하였다. 본 연구의 대상은 서울 및 경기지역에 거주하고 있는 20대 이상 일반 소비자를 대상으로 2015년 2월 23일부터 3월 30일까지 5주간 설문조사를 실시하였으며, 447부(회수율 88.9%)의 실증자료를 얻어 SPSS WIN 21.0프로그램을 이용하여 분석하였다. 본 논문은 성별에 따른 기능성 화장품 선택속성 항목의 중요도-만족도 분석에 관한 연구로서 요인분석 결과 17개의 속성을 총 4개의 요인(기능성 요인, 표시 요인, 홍보 요인, 제품 요인)으로 분류하였다. 또한, 각 요인들의 내적일관성을 검정한 Cronbach's ${\alpha}$값은 모두 0.5 이상으로 신뢰성을 확보한 것으로 나타났다. 성별에 따른 기능성화장품 선택속성 항목의 중요도와 만족도 차이 결과 중요도의 전체평균은 여성이 5.89점/7점으로 남성의 5.66점/7점보다 유의적으로 높게 나타났고(p<0.001), 남 여 간의 큰 차이를 보이는 속성들로 '주름개선', '미백기능', '기능성', '유통기한', '전성분표시제', '다양한 홍보' 등으로 나타났다. IPA분석 결과, 남성의 경우 II사분면의 항목으로는 '가격', '기능성', '발림성', '전성분표시제'로 나타났으며, 여성의 경우 '가격', '미백개선', '주름개선', '기능성', '전성분표시제'로 나타났다. 따라서 화장품 관련 업체 및 기업은 기능성화장품 개발 시 남 여 소비자가 공통적으로 만족도가 낮다고 응답한 '가격', '기능성', '전성분표시제' 항목에서 우선적으로 집중 개선해야 할 것으로 판단된다. 특히 '가격'적인 면에서는 합리적이고 경제적인 가격 책정이 필요할 것으로 사료된다.

    공연장에서 다중 몰입도 측정을 위한 시스템 개발 (System Development for Measuring Group Engagement in the Art Center)

    • 류준모;최일영;최이권;김재경
      • 지능정보연구
      • /
      • 제20권3호
      • /
      • pp.45-58
      • /
      • 2014
    • 몰입은 관람객이 콘텐츠를 관람할 때 관람객들이 콘텐츠에 몰두하고 있는 심리적 상태를 의미하는 것으로, 관람객의 몰입경험은 콘텐츠의 만족도에 긍정적인 영향을 미친다. 따라서 공연 같은 콘텐츠를 제공하는 기업들은 콘텐츠의 흥행을 위해 관람객의 몰입도를 측정하는 것은 매우 중요하다. 설문 등의 표본조사 방법을 통해 관람객의 몰입도를 측정 연구는 방송분야 등 에서 널리 사용되고 있다. 이러한 몰입도 측정방법은 콘텐츠 관람 이후 설문을 실시하기 때문에 몰입도를 실시간으로 측정할 수 없을 뿐만 아니라 몰입도 측정의 정확성이 저하되는 문제 등이 있다. 이러한 문제를 해결하기 위하여 생리적 반응이나 얼굴 표정 분석, 그리고 움직임 관찰 방법 등을 이용하여 몰입도를 측정하는 연구가 수행되고 있다. 생체 신호를 이용하여 몰입도를 측정하는 연구의 경우, 1인을 대상으로 생체신호를 측정할 뿐만 아니라, 많은 데이터 처리 시간과 비용이 소모되는 단점이 있어 많은 관람객이 관람하는 공연장에 적용하기에는 한계가 있다. 얼굴 표정인식 통해 몰입도를 측정하는 경우도 1인을 대상으로 하고 있으며, 밝은 조명의 실험실 환경에서만 가능하다는 단점이 존재한다. 또한 관람객들의 움직인 동기화를 이용하여 몰입도를 특정한 연구는 다중관객을 대상으로 하였지만, 이는 실험실 환경에 한정하여 적용된 사례이다. 따라서 본 연구에서는 공연장, 시사회관 등 많은 관람객들이 콘텐츠를 관람하는 실제 환경에서 다중관람객이 다중몰입도의 정량적 평가를 위한 시스템을 설계하고 개발하였다. 제안된 시스템은 외부장치, 서버, 내부장치 등의 3부분으로 구성되어 있다. 서울시 마포구 상암동에 위치한 DMC 홍보관에 상설 전시장으로 운영하고 있으며, 관람객들을 대상으로 데이터를 획득하고 있다. 제안하고 있는 시스템을 활용하면 콘텐츠의 어느 구간에서 관객들이 몰입을 하고 있는지, 어느 구간에서 몰입을 하고 있지 못한지 분석가능하기 때문에, 향후 콘텐츠 제작 및 마케팅에 유용하게 활용할 수 있을 것으로 기대된다.

    인공지능을 활용한 경관 지각반응 예측모델 개발 가능성 기초연구 - 머신러닝 기법을 중심으로 - (Basic Research on the Possibility of Developing a Landscape Perceptual Response Prediction Model Using Artificial Intelligence - Focusing on Machine Learning Techniques -)

    • 김진표;서주환
      • 한국조경학회지
      • /
      • 제51권3호
      • /
      • pp.70-82
      • /
      • 2023
    • 최근 IT 기술과 데이터의 범람으로 생활 전반적인 부분의 패러다임이 전환되고 있다. 이러한 기술의 발전과 변화는 학술영역에도 영향을 미치고 있다. 학문적 교류와 연계를 통해 연구주제나 연구 방법의 개선이 이루어지고 있다. 특히, 데이터 기반의 연구 방법이 다양한 학문분야에서 진행되고 있으며 조경학에서도 지속적인 연구가 필요한 시점이다. 따라서 본 연구에서는 이러한 시대적 상황을 반영하여 인공지능의 한 분야인 머신러닝을 활용한 경관 선호 평가 및 예측모델의 개발 가능성을 알아보는 것을 목표로 한다. 본 연구의 목표를 달성하기 위하여 경관 분야에 머신러닝 기법을 적용하여 경관 선호 평가 및 예측 모델을 구축하고, 구축된 모형의 모의정도를 검증하였다. 이를 위해 본 연구에서는 최근 신재생에너지 사업으로 주목받는 풍력발전시설 경관 이미지를 연구대상으로 선정하였다. 분석을 위하여 풍력발전시설 경관 이미지를 웹크롤링 기법을 활용하여 수집하고 분석 테이터셋을 구축하였다. 우수한 성능의 예측모델 도출을 위하여 머신러닝 분석에 활용되는 University of Ljubljana의 프로그램인 오렌지 버전 3.33을 활용하였다. 또, 머신러닝 학습데이터의 평가기준을 통합한 모델과 평가기준 별도 모델 구조를 활용하였으며, 머신러닝 분류모델에 적합한 kNN. SVM, Random Forest, Logistic Regression, Neural Network 알고리즘을 사용해 모델을 생성하였다. 생성된 모델을 성능 평가를 실시하여 본 연구에 가장 적합한 예측모델을 도출하였다. 본 연구에서 도출된 예측모델은 경관의 유형에 따른 분류, 경관과 대상의 시거리에 따른 분류, 선호에 따른 분류 등 3가지 평가기준을 별도로 평가 후 종합해 예측하여 결과를 도출하였다. 연구 결과 경관 유형에 따른 평가 기준 정확도 0.986, 시거리에 따른 평가 기준 정확도 0.973, 선호에 따른 평가 기준 정확도 0.952에 달하는 높은 정확도를 가진 예측모델을 개발하였으며, 평가데이터 예측 결과를 통한 검증과정을 보아도 모델의 성능 치를 상회하는 성과를 도출했음을 알 수 있다. 경관 관련 연구에서 머신러닝을 활용한 예측모델 개발 가능성을 알아본 실험적 시도로 이미지 데이터의 수집 및 정제를 통해 데이터 세트를 구축하여 높은 성능의 예측모델이 생성 가능하며, 이후 경관 관련 연구 분야에 활용될 수 있다는 가능성을 확인할 수 있었다. 본 연구의 결과와 시사점, 한계점을 반영한다면 풍력발전시설의 경관뿐만 아니라 자연경관이나 문화경관 등 다양한 형태의 경관 예측모델 개발이 가능할 것으로 생각되며, 경관 유형에 따라 이미지를 분류하는 모델의 연구를 통해 데이터 분류의 시간을 단축하거나 머신러닝을 활용한 경관예측 인자분석을 통해 경관계획 요소의 중요도 분석 등의 주제에 맞는 연구 방법을 탐색하고 적용하여 후속 연구를 진행한다면 조경학 분야에서도 머신러닝 기법을 보다 유용하고 가치 있게 활용할 수 있을 것으로 생각된다.

    가정과 교사의 창의.인성 교육에 대한 관심과 실행에 대한 인식 - CBAM 모형에 기초하여- (Home Economics teachers' concern on creativity and personality education in Home Economics classes: Based on the concerns based adoption model(CBAM))

    • 이인숙;박미정;채정현
      • 한국가정과교육학회지
      • /
      • 제24권2호
      • /
      • pp.117-134
      • /
      • 2012
    • 본 연구의 목적은 가정과교육에서 창의 인성 교육에 대한 가정과 교사의 관심 단계와 실행 수준, 그리고 실행 실태를 알아보는데 있다. 연구 자료는 전국의 중학교 가정과 교사를 대상으로 체계적 표집과 편의 표집을 하여 우편과 이메일을 통해 설문지를 배포하고 회수된 187부를 최종 분석에 사용하였다. 조사 도구는 주로 Hall(1987)이 개발한 혁신에 대한 교사의 관심도와 실행 수준에 대한 질문지를 수정 보완하여 사용하였고 그 외는 선행연구를 기초하여 개발하였으며 타당도와 신뢰도를 검증하였다. 자료는 SPSS/window(12.0) 프로그램을 이용하여 빈도, 백분율, 평균, 표준편차, t-test, ANOVA를 실시하였다. 본 연구를 통해 밝혀진 결과를 요약하면 다음과 같다. 첫째, 창의 인성 교육에 대한 가정과 교사의 관심 단계는 정보적 관심 단계(85.51)가 가장 높았으며 다음으로 개인적 관심 단계(85.18), 운영적 관심 단계(81.88), 지각적 관심 단계(82.15), 강화적 관심 단계(68.80), 협동적 관심 단계(61.97), 그리고 결과적 관심단계(59.76)의 순으로 나타났다. 둘째, 창의 인성 교육에 대한 가정과 교사의 실행 수준은 기계적 실행 수준(수준 3; 21.4%)이 가장 많았으며, 다음으로 탐색 수준(수준 1; 20.9%), 정교화 수준(수준 5; 17.1%), 사용하지 않는 수준(수준 0; 15.0%), 준비 수준(수준 2; 10.2%), 통합 수준(수준 6; 5.9%), 갱신 수준(수준 7; 4.8%), 일상화 수준(수준 4; 4.8%) 순이었다. 셋째, 창의 인성 교육에 대한 가정과 교사의 실행 실태를 조사한 결과, 반 이상의 가정과 교사(56.1%)는 가정과 수업에서 인성 교육에 치중하고 있으며, 31.0%의 교사는 창의 인성 교육을 모두 실행한다고 응답하였다. 반면 소수의 교사(6.4%)는 창의성 교육을 실행한다고 응답하였고 같은 수의 교사(6.4%)는 창의성과 인성 교육 어느 것도 실행하지 않는다고 응답하였다. 가정과 교사의 창의 인성 교육 요소의 실행 정도를 조사한 결과, 창의 인성 교육 요소의 실행은 평균은 5점 만점에서 3.76이었고 창의성 요소의 평균은 3.59, 인성 요소의 평균은 3.94로 보통보다 높았다. 창의성 교육 요소의 실행 정도에 대해서, 개방성/민감성(3.97)을 가장 많이 실행하였고 다음으로 문제해결능력(3.79), 호기심/흥미(3.73), 비판적 사고(3.68), 논리/분석적 사고(3.63), 문제발견능력(3.61), 독창성(3.57), 유추성(3.47), 유창성/융통성(3.46), 정교성(3.46), 상상력(3.37), 몰입/공감(3.37)의 순으로 실행하였다. 인성 교육 요소는 실천력(4.07)을 가장 많이 실행하였고, 다음으로 협동/배려/공정(4.06), 자기관리능력(4.04), 시민의식(4.04), 진로개발능력(4.03), 환경친화능력(3.95), 책임(감)/소유(3.94), 의사결정능력(3.89), 신뢰/정직/약속(3.88), 자율성(3.86), 글로벌역량(3.55)의 순으로 실행한 것으로 나타났다. 창의 인성 교육을 실행할 때 어려운 점으로, 많은 가정과 교사(64.71%)는 창의 인성 교육을 실행할 수업 자료가 부족한 데 있다고 하였으며, 40.11%의 교사는 창의 인성 교육의 연수 기회가 적은데 있다고 응답하였다. 한편 38.50%의 가정과 교사는 창의 인성 교육에 대한 평가 기준을 설정하거나 평가 도구를 개발하는 것이 어렵다고 응답하였고, 25.67%의 교사는 창의 인성 교육 방법을 모른다고 응답하였다. 창의 인성 교육 실행을 위해서 필요한 지원에 대해서, '창의 인성 교육과 관련된 학생들의 체험활동의 확대'(4.34), '창의성과 인성을 중시하는 가정과 수업 문화 조성'(4.29), '학생 발달 단계에 적합한 창의 인성 교육 내용'(4.27), '창의 인성 교육을 담당할 교수 인력 확보'(4.21), '창의 인성 교육의 개념과 가치 확립'(4.09), '지역 사회 기업 등과 연계한 창의 인성 교육 추진'(3.94)의 순으로 응답하였다.

    • PDF

    Sensory Information Processing

    • Yoshimoto, Chiyoshi
      • 대한의용생체공학회:의공학회지
      • /
      • 제6권2호
      • /
      • pp.1-8
      • /
      • 1985
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

    • PDF

    High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

    • H.S-Ching;Oh, M.ishi;M.Morimoto
      • 한국우주과학회:학술대회논문집(한국우주과학회보)
      • /
      • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
      • /
      • pp.17-17
      • /
      • 1993
    • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

    • PDF