• Title/Summary/Keyword: Performance maintenance

Search Result 3,007, Processing Time 0.029 seconds

The Development of a 20MW PWM Driver for Advanced Fifteen-Phase Propulsion Induction Motors

  • Sun, Chi;Ai, Sheng;Hu, Liangdeng;Chen, Yulin
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.146-159
    • /
    • 2015
  • Since the power capacity needed for the propulsion of large ships is very large, a multiphase AC induction propulsion mode is generally adopted to meet the higher requirements of reliability, redundancy and maintainability. This paper gives a detailed description of the development of a 20MW fifteen-phase PWM driver for advanced fifteen-phase propulsion induction motors with a special third-harmonic injection in terms of the main circuit hardware, control system design, experiments, etc. The adoption of the modular design method for the main circuit hardware design can make the enclosed mechanical structure simple and maintainable. It can also avoid the larger switch stresses caused by the multiple turn on of the IGBTs in conventional large-capacity converter systems. The use of the distributed controller design method based on a high-speed fiber-optic ring net for the control system can overcome such disadvantages as the poor reliability and long maintenance times arising from the conventional centralized controller which is designed according to point-to-point communication. Finally, the performance of the 20MW PWM driver is verified by experimentation on a new fifteen-phase induction propulsion motor.

A study on characteristic of the smoke removal of an air cleaner by monitoring of turbidity with laser (레이저 혼탁도 모니터링을 통한 공기청정 특성에 관한 연구)

  • Kim, Su-Weon;Park, Jong-Woong;Joung, Jong-Han;Chung, Hyun-Ju;Lee, Yu-Soo;Jeon, Jin-An;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1698-1700
    • /
    • 2003
  • The electrostatic precipitator(ESP) is a device for removing particulate pollutants in the form of either a solid (dust or fumes) or a liquid (mist) from a gas using an electrostatic force, Electrostatic precipitation has been widely used for cleaning gas from almost all industrial processes with a medium to large gas volume(>2,000 $m^3/min$), including utility boilers, blast furnaces, and cement kilns. ESP is also in wide use for air cleaning in living environments (home, offices, hospitals, etc.) ESP has large advantages over other particulate control device : a low operating cost, a high collection performance, and ease of maintenance. The purpose of this study is to investigate the characteristics of the smoke removal of an air cleaner by adjusting variable frequency and monitoring of turbidity three results of this research are as follows ;the first is the best efficient switching frequency which is 60Hz, the second is the smoke removal time which is obtained to 9 seconds, third is that the best efficient firing angle is $90^{\circ}$ As a result, the switching trigger frequency and SCR gate firing angle is very important factor to predict the best collection efficiency.

  • PDF

The Influence of Software Engineering Levels on Defect Removal Efficiency (소프트웨어공학수준이 결함제거효율성에 미치는 영향)

  • Lee, Jong Moo;Kim, Seung Kwon;Park, Ho In
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.9 no.4
    • /
    • pp.239-249
    • /
    • 2013
  • The role of software process is getting more important to make good quality softwares. One of the measures to improve the software process is Defect Removal Efficiency(DRE). DRE gives a measure of the development team ability to remove defects prior to release. It is calculated as a ratio of defects resolved to total number of defects found. Software Engineering Levels are usually decided by CMMI Model. The model is designed to help organizations improve their software product and service development, acquisition, and maintenance processes. The score of software engineering levels can be calculated by CMMI model. The levels are composed of the three groups(absent, average, and advanced). This study is to find if there is any difference among the three categories in term of the result of software engineering levels on DRE. We propose One way ANOVA to analyze influence of software engineering levels on DRE. Bootstrap method is also used to estimate the sampling distribution of the original sample because the data are not sampled randomly. The method is a statistical method for estimating the sampling distribution of an estimator by sampling with replacement from the original sample. The data were collected in 106 software development projects by the survey. The result of this study tells that there is some difference of DRE among the groups. The higher the software engineering level of a specific company becomes, the better its DRE gets, which means that the companies trying to improve software process can increase their good management performance.

A Study on Correlation of Effective Discharge Energy and Exhaust Emission of Gasoline Vehicle (가솔린자동차의 유효방전에너지와 배기가스와의 상관관계 연구)

  • Yoo, Jongsik;Kim, Chulsoo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.70-75
    • /
    • 2014
  • The experiment was done on traveling at the speed of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. The experimental method were employed to measure the waveform of secondary ignition coil and exhaust emission. In this experiment, the correlation between the secondary waveform coming from ignition coil and exhaust emission were measured in decrepit vehicle. The secondary waveform characterized by the value of effective discharge energy. The following results are obtained by analyzing the data relativity between the effective discharge energy and exhaust emission. The variation rate of effective discharge energy was largest 60km/h, 20km/h, 100km/h velocity in the ordered named. As the vehicle velocity increases, the average variation rate of CO and $NO_X$ decreases and that of HC and $CO_2$ decrease. The value of effective discharge energy, CO, $NO_X$ and fuel consumption is measured badly in case of car with failures in MAP, spark plug and good in case of car with before and after maintenance regardless of vehicle velocities. The value of effective discharge energy is to be nearly parabolic shape as vehicle velocity increases. As the value of effective discharge energy increases, the value of $NO_X$, HC and $CO_2$ decrease, the value of CO increase. The most sensible factors of exhaust emission were CO, $NO_X$, and the small variation factors were HC, $CO_2$.

DVI cable Improvement for Preventing MFD Abnormal Display of a Rotary-wing Aircraft (회전익 항공기 다기능시현기의 이상시현을 방지하기 위한 DVI 케이블 개선)

  • Kim, Young Mok;Jeong, Sang-Gyu;Cho, Jae Po;Choi, Doo-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.9
    • /
    • pp.782-789
    • /
    • 2018
  • Multi-Function Display (MFD) of Korean Utility Helicopter (KUH) displays image information(navigation, flight, topographical and maintenance information) delivered from Mission Computer (MC) during flight operation. The abnormal display of MFD such as flickering phenomenon was identified in the system development. It was solved by improving the shielding performance of the DVI cable and changing the DVI cable installation path at the first mass production. However, it was occurred again when the aircraft was operated for one or two years after delivery. It was also identified in the evaluation process of the derivative helicopters. Therefore, a comprehensive review of the aircraft system level has been performed to solve the problem of MFD malfunction at first and then a design improvement plan was derived by improving the DVI cable. In this paper, the causes of MFD anomalies are analyzed and also the process of design improvement are summarized. The validity of the improvement has been verified through the DVI cable assembly comparison test, SIL/ground/flight test.

Plasmaspheric contribution to the GPS TEC

  • Jee, Geon-Hwa;Lee, Han-Byul;Kim, Yong-Ha;Chung, Jong-Kyun;Cho, Jung-Ho
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.30.3-31
    • /
    • 2010
  • We performed a comprehensive comparison between GPS Global Ionosphere Map (GIM) and TOPEX/Jason (T-J) TEC data for the periods of 1998~2009 in order to assess the performance of GIM over the global ocean where the GPS ground stations are very sparse. Using the GIM model constructed by CODE at University of Bern, the GIM TEC values were obtained along the T-J satellite orbit at the locations and times of the measurements and then binned into various geophysical conditions for direct comparison with the T-J TECs. On the whole, the GIM model was able to reproduce the spatial and temporal variations of the global ionosphere as well as the seasonal variations. However, the GIM model was not accurate enough to represent the well-known ionospheric structures such as the equatorial anomaly, the Weddell Sea Anomaly, and the longitudinal wave structure. Furthermore, there seems to be a fundamental limitation of the model showing the unexpected negative differences (i.e., GPS < T-J) in the northern high latitude and the southern middle and high latitude regions. The positive relative differences (i.e., GIM > T-J) at night represent the plasmaspheric contribution to GPS TEC, which is maximized, reaching up to 100% of the corresponding T-J TEC values in the early morning sector. In particular, the relative differences decreased with increasing solar activity and this may indicate that the plasmaspheric contribution to the maintenance of the nighttime ionosphere does not increase with solar activity, which is different from what we normally anticipate. Among these results, the plasmaspheric contribution to the ionospheric GPS TEC will be presented in this talk and the rest of it will presented in the companion paper (poster presentation).

  • PDF

Effect of Orifice Type and Number on the Mixing and Flow Characteristics in In-line Mixer (관내 혼화장치의 오리피스 형상과 개수에 따른 혼화 및 유동특성)

  • Jeong, Seon Yong;Chung, Won Sik;Rhi, Seok Ho;Lee, Kye Bock;Lee, Dae Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.2
    • /
    • pp.6-13
    • /
    • 2017
  • This study examines the effect of the type and number of orifices in an in-line mixer to improve the mixing performance and pressure loss. Recently, in-line non-power-consuming mixers have been increasingly used to complement mechanical mixers, which have a long dwell time, noise, excessive energy consumption, and high maintenance costs. An in-line mixer with an orifice for efficient mixing in water treatment was examined by numerical analysis using the commercial code FLUENT. The flow characteristics of pressure loss and velocity distribution within the mixer and the mixing efficiency were compared with and without the orifices. The CFD results show that the mixing efficiency was improved, but the pressure loss was increased by the in-line mixer with an orifice. A sensitivity study was also done on the principal parameters.

Design of the 140W level-small sized LED Power Control Circuit (140W 급-저면적 LED 전원 제어 회로 설계)

  • An, Ho-Myoung;Lee, Juseong;Kim, Byungcheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.11 no.5
    • /
    • pp.586-592
    • /
    • 2018
  • In this paper, HIC with various functions is proposed for the design 140W LED power control circuit. The proposed HIC integrates constant voltage/constant current circuit, short circuit protection circuit, internal constant voltage circuit, and dimmer circuit, thereby reducing the horizontal length of the PCB by 16% comparing with the conventional system. Through various experiments, we verified the performance of each block implemented inside of HIC with numerical results. (Constant voltage variation ratio: 2.9%, dimmer circuit duty variation within 5%, stable short protection at 720 mA) Since the PCB area can be significantly reduced by applying the proposed HIC. It is possible to reduce the PCB manufacturing time which takes up most of the manufacturing time, however, It is expected that the faulted power module can be replaced without replacing the whole PCB, so that maintenance / repair can be made easier.

A Study on the Decision Process for Adoption of Enterprise Endpoint Security solutions (기업용 Endpoint 보안솔루션 도입을 위한 의사결정 프로세스에 대한 연구)

  • Moon, Heoungkeun;Roh, Yonghun;Park, Sungsik
    • Journal of Information Technology and Architecture
    • /
    • v.11 no.2
    • /
    • pp.143-155
    • /
    • 2014
  • In recent years, domestic electronics, banking, electricity, services, manufacturing, pharmaceutical, corporate type and malicious hackers is corporate security through the accident occurred and the resulting loss of corporate information and the damage each year is steadily increasing. Many companies have responded to domestic business activities and to protect critical information related to laptops, smart phones, tablets, and introduced a variety of Endpoint security solutions within. However, being introduced to senselessly Endpoint security solution across the over-budget, with the same features and performance, such as conflicts and problems arise, resulting in additional maintenance costs, in an effort to resolve the conflict in the operational security of the IT department's new difficulty in becoming. Here is the introduction and operation of these Endpoint security solutions in order to solve the problem on employees's PC into the center of the information security governance based on Endpoint security solution to provide the process for determining the solutions presented.

A Numerical Study on Safety Evaluation of Prefabricated Sewage-Pipe Plastic Foundation Based on Pipe Diameters and Buried Soil Depths (하수관거 직경과 심도를 고려한 하수관거 플라스틱 받침기초의 안전성 평가를 위한 해석연구)

  • Park, Rae-Jin;Park, Jong-Sup
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4322-4327
    • /
    • 2015
  • Improper backfill materials and compaction controls under pipelines have become one of the major causes of failure in many sewage pipeline systems. A study on backfill materials and compaction controls has been considered for a long time. However, structural supporters under the pipe were recently concerned because of pipeline repair and maintenance. This paper presents a prefabricated plastic foundation for supporting a sewage pipe system and increasing the performance function of the pipes. Several analytical models for the plastic foundations were investigated using finite-element program, ABAQUS, for checking safety. Comparing with the results of analyses, some of economic design sections based on the sizes of pipe diameters, 600mm, 700 and 600mm, were evaluated. These results could be applied to a pipeline system with a prefabricated plastic foundation with respect to pipe diameters and buried depths.