• Title/Summary/Keyword: Performance conversion

Search Result 2,874, Processing Time 0.029 seconds

Impact of Ash Deposit on Conversion Efficiency of Wall Flow Type Monolithic SCR Reactor (벽유동 방식 담체를 사용하는 SCR 촉매 반응기에서 재 퇴적이 변환 효율에 미치는 영향에 대한 연구)

  • Park, Soo-Youl
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.27-35
    • /
    • 2013
  • SCR (Selective Catalytic Reduction) on DPF (Diesel Particulate Filter) is a multi-functional after-treatment device which integrates soot filtration and DeNOx function into a single can. Because of its advantage in package and cost, the SCR on DPF is considered as a potential candidate for future application. It inherently employes wall flow type monolithic reactor so ash included in exhaust gas may deposit inside the inlet channel of this device. This study is intended to identify the impact of ash deposit on SCR reaction under wall flow type monolithic reactor. Simulation approach is used so relevant species transport equations for wall flow type monolith is derived. These equations can be solved together with momentum conservation equations and give solution for conversion performance. Both ash deposit and clean catalyst case are simulated and comparison of these two cases gives an insight for the impact of ash deposit on conversion performance. Ash deposit can be classified as ash layer and ash plug. and impact of ash deposit is described along with different morphology of ash deposit.

Effect of $NH_3$/NOx ratio and Catalyst Temperature on DeNOx Performance in the $NH_3$-SCR reactor ($NH_3$-SCR 반응기 내에서의 $NH_3$/NOx 및 SCR 촉매 온도가 DeNOx 성능에 미치는 영향)

  • Hong, Kil-Hwa;Gong, Ho-Jeong;Hwang, In-Goo;Park, Sim-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3096-3101
    • /
    • 2008
  • Selective Catalytic Reduction (SCR) technology is well-known to be effective for the reduction of NOx emission. So car manufacturers has adopted Ures-SCR system to be satisfied with emission regulation. This paper discusses the effective of $NH_3/NOx$ ratio and SCR catalyst temperature in the $NH_3$-SCR reactor on DeNOx performance. So it is shown the characteristic of NOx conversion and ammonia slip using the $NH_3$ instead of Urea-Solution. From the result of this study, it is found to optimize $NH_3/NOx$ ratio to have the best case of high NOx conversion and low ammonia slip at variable SCR catalyst temperatures. Lastly, it is also found the characteristics of NOx conversion and ammonia slip with compared with Urea.

  • PDF

Performance Evaluation of Fixed-concentrated Photovoltaic/Thermal Hybrid Panel using Reflector (반사판을 이용한 고정식 집속형 태양광.열복합패널의 성능평가)

  • Seo, Yu-Jin;Huh, Chang-Su
    • Journal of the Korean Solar Energy Society
    • /
    • v.25 no.4
    • /
    • pp.85-92
    • /
    • 2005
  • One of the most effective methods for utilizing solar energy is to combine thermal solar and optical energy simultaneously using a hybrid panel. Many systems using various kinds of photovoltaic panels have already been constructed. But utilizing solar energy by means of a hybrid panel with concentrator has not been to be attempted yet. Normally if sunlight is directed on the solar cell, and there is no increase in temperature, the absorption energy of each cell will increase per unit area. In a silicon solar cell. however, cell conversion efficiency decreases according to the increasing temperature. Therefore, to maintain cell conversion efficiency under normal condition, it is necessary to keep the cell at operating temperature. we design and make new hybrid panel with cooling system to prevent increasing of temperature on cell, collect effectively thermal energy. We compared performance of new hybrid panel with PV module and thermal panel. We also evaluated conversion efficiency, electric power and thermal capacity and confirmed cooling effect from thermal absorption efficiency.

Conversion Profit and Optimal Capacity of Cloud Computer for Integrating Legacy Campus Web Servers (캠퍼스내 레거시 웹서버 통합 운영을 위한 클라우드 컴퓨팅의 최적용량 및 전환이익 분석)

  • Lee, Goo Yeon;Choi, Chang Yeol;Choi, Hwang Kyu;Jang, Min;Yoon, Jae Ku
    • Journal of Digital Contents Society
    • /
    • v.15 no.2
    • /
    • pp.289-300
    • /
    • 2014
  • Cloud computing helps users to save a significant amount of cost that is related to infrastructure investment, management, and maintenance. In this paper, we study the conversion planning from campus legacy web servers into an integrated cloud computing web server system. We also analyze the conversion profit when campus web servers are integrated into a cloud computer. We first investigate the cost of legacy system model of campus web servers operated by individual laboratories, departments, institutes and so on. Next, we set up a cloud computer model for the integrated web services meeting the same performance requirements. Then, we derive the conversion profit. From the result of the derivation, we see that the conversion can be effectively applied to and adopted by mid or large sized campuses and similar institutions that provide web services.

Design and implementation of power-controlled front-end module for direct conversion receiver (전력제어 직접변환수신 6단자 소자 설계 및 제작)

  • Kim, Young-Wan
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.11
    • /
    • pp.2391-2396
    • /
    • 2010
  • The power-controlled six-port element that can control the local oscillator signal power and receiving RF signal power was designed and implemented in this paper. The direct conversion six-port element configuration was proposed, which provides the constant six-port output power by controlling the six-port input power with various signal strength. The direct conversion six-port element protects the power detector element of six-port receiver from the saturation status and compensates the transmission performance degradation. For implementation of power-controlled six-port element, the power-controlled six-port element including the power controller was analyzed. The implemented power-controlled six-port element shows the power control capability of 36 dB and gain imbalance of about 1.6 dB, phase imbalance of about $4^{\circ}$ in the frequency range of 1.69 GHz. The measured results show the good performance as direct conversion front-end element.

A Study on a Performance Analysis of Direct-Conversion Receiver Using AC-Coupling Method in Additive White Gaussian Noise Channel Environment (AWGN 채널환경에서 AC-Coupling기법을 이용한 Direct-Conversion 수신기의 성능분석에 관한 연구)

  • 박성진;김칠성;성태경;조형래
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.05a
    • /
    • pp.205-209
    • /
    • 2000
  • Modem wireless communication equipments provides various multimedia and aims at the development of low-power, minimum size and weight, and low-cost implimentations. Because of the heterodyne architecture which was invented many decades ago in the wireless communication system using too many components, it was difficult to make it small, compact and On-Chip so it does not proper for future communication. That gives rise a new developing architecture, so called, Direct Conversion. Because The Direct Conversion down-converts the wireless frequency band to baseband directly, it does not need using additive components and has a merit of reduction in power dissipation. We describes the Direct Conversion architecture and DC-Offset, which must be solved, theorectically and predicts system performance enhancement when adopt the AC-Coupling method.

  • PDF

An Efficient Converter Placement in Wavelength-Routed WDM Networks with Sparse-Partial-Limited Wavelength Conversion (파장분할다중화 광통신망에서 산재-부분-제한영역 파장 변환기의 효율적인 배치 알고리듬)

  • Jeong, Han-You;Seo, Seung-Woo;Choi, Yoon-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11B
    • /
    • pp.1596-1606
    • /
    • 2010
  • In this paper, we present a new analytical model that can precisely estimate the blocking performance of wavelength-routed WDM networks with sparse-partial-limited wavelength conversion (SPLWC). The proposed model accounts for the two sources of call blocking in a wavelength converter: range blocking originated from the limited conversion range of a wavelength converter; and capacity blocking induced from the limited number of wavelength converters. Based on the proposed model, we also present a new converter placement algorithm that minimizes the amount of wavelength conversion capability, while satisfying the given constraint on the network-wide blocking probability. From the numerical results obtained from the EON, we demonstrate that the blocking probability of the analytical model closely matches with that of the simulation. We also show that, by efficiently combining the existing sparse, partial, and limited wavelength conversion, the SPL WC can achieve the required blocking performance with the least amount of wavelength conversion cost.

Study on The Blocking Performance of All-Optical Network (완전 광 네트워크의 블러킹 성능에 관한 연구)

  • 강안구;최한규;조규섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.4A
    • /
    • pp.579-585
    • /
    • 2000
  • This paper analyzes and compares the blocking performance of all-optical wavelength-routed networks providing circuit switching among users. A connection between two nodes along a particular path must use a single wavelength on all hops, or links, within the path. We then calculate the blocking probability along a lightpath with wavelength conversion in a network with an arbitrary topology and show the network performance improvement offered by node with limited translation technology. We also propose a new schematic method for the performance analysis of different types of network architecture which is composed of nodes with or without wavelength conversion(NC, FC or LC).

  • PDF

Effect of Blade Sweep on the Performance of the Wells Turbine for Wave Power Conversion (파력발전용 웰즈터빈성능에 미치는 날개 Sweep의 영향)

  • Kim, Tae-Ho;Setoguchi, Toshiaki;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.961-966
    • /
    • 2001
  • The Wells turbine is one of the simplest and most promising self-rectifying air turbines which are useful for the systems of alternative energy development in near future, and it is economically desirable from the point of view of the practical use, as well. To investigate the effect of blade sweep on the performance of the Wells turbine, computations of a fully 3-D Navier-Stokes are carried out under steady flow conditions of NACA0020 blade. It is known that the performance of the Wells turbine is considerably influenced by the blade sweep. An optimum blade sweep ratio(f=0.35) for the NACA0020 is found to be the most promising for the practical use, and this value is in good agreement with the previous experiments. It is also found that the overall turbine performance for the NACA0020 is better than that for the CA9.

  • PDF

Implementation of IQ/IDCT in H.264/AVC Decoder Using GP-GPU (GP-GPU를 이용한 H.264/AVC 디코더의 IQ/IDCT구현)

  • Jeong, Jun-Mo;Lee, Kwang-Yeob
    • Journal of IKEEE
    • /
    • v.14 no.2
    • /
    • pp.76-81
    • /
    • 2010
  • The need for dedicated hardware continue to decrease as the mobile CPU's performance increases. But, there is a limit to a mobile CPU's performance. GP-GPU(General-Purpose computing on Graphics Processing Units) can improve performance without adding other dedicated hardware. This paper presents the implementation of Inverse Quantization, Inverse DCT and Color Space Conversion module in H.264/AVC decoder using GP-GPU for a mobile environments. The proposed architecture improves approximately 40% of performance when it use all the features.