• 제목/요약/키워드: Performance and Efficiency Drop

검색결과 264건 처리시간 0.025초

정전형여과집진방식에서 여과특성에 관한 연구 (A Study on Filtration Performance Test with Electrostatically Enhanced Fabric Filter)

  • 천중국;박출재;최금찬
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.361-367
    • /
    • 1995
  • This study has been carried out to investigate the filteration performance of Electrostatically Stimulated Fabric Filter(ESFF) at high temperature condition. The electric field was maintained parallel to the fabric surface. The benefits of ESFF are lower residual pressure drop, improvement of fine particle removal efficiency and increasing reduced rate of pressure drop during a filteration cycle, stable operation at higher filtering velocities. According to the variance of filtering velocities and dust loadings, the results are summarized as follows; By imposing an electric field on the filter, the reduced rate of pressure drop was 7.sim.18% at room temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Under the electric field around the filter, the reduced rate of pressure drop was 10.sim.35% at high temperature, and when filtering velocity was 1.8m/min and dust loading was 1g/m$^{3}$, the value of reduced rate of pressure drop was shown the highest. Most of all, at high temperature, the value of reduced rate of pressure drop was resulted to 25%. Also the collecting efficiency was shown clearly improved. By the SEM photo analysis, the number of penetrated particles at the Conventional Fabric Filter was approximately two times that of Electrostatically Stimulated Fabric Filter.

  • PDF

압축기용 흡입머플러의 음향 및 유동해석 (Acoustic and Flow-filed Analysis of Suction Muffler in Compressor)

  • 주재만;이학준;오상경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1162-1167
    • /
    • 2001
  • Suction valve fluttering is generated by reciprocating motions of the piston inhaling and discharging process of gas in the hermetic compressor. A reactive type suction muffler, which produces high pressure-drop because of its complicated flow path, controls the impulsive noise radiated from the flutter of suction valve. The high-pressure drop in the muffler increases the transmission loss, but reduces the EER(Energy Efficiency Ratio) of the compressor. We consider how to design the high acoustic attenuation and low pressure-drop performance to take account of the acoustic and flow performances of the suction muffler. In this study, we identified the suction noise source of compressor from the measurement of the acoustic pulsation and flutter of suction valve. We analyzed the acoustic characteristics of muffler using the finite element method, and compared the experimental and analytical characteristics of flow path of suction muffler. Theoretical predictions and experimental results are compared from the viewpoint of the acoustic performance and energy efficiency of the compressor.

  • PDF

무인정찰기 착륙장치 성능입증을 위한 낙하시험 (Drop Test for the UAV Landing Gear Performance Verification)

  • 신정우;이승규;양진열;김성준;황인희;정상준
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 추계학술대회 논문집
    • /
    • pp.250-254
    • /
    • 2011
  • Main role of landing gear is to absorb the energy which is generated by aircraft lanidng and ground maneuvering. Generally, in order to absorb the impact energy during landing, oleo-pneumatic type shock absorber is used for aircraft landing gear. Oleo-pneumatic type shock absorber has a good energy absorbing efficiency and is light in weight because its structure is relatively simple. For the landing gear development, it is necessary to conduct drop test in order to verify shock absorbing performance. In the drop test, first, gas spring curve verification tests are conducted. Then, limit and reserve energy absorption drop tests are performed based on the STANAG 4671. The drop tests results with performance analysis results are presented.

  • PDF

산업용 필터백의 구조에 따른 여과성능 특성 (Filtration Performance Characteristics according to Filter Bag Structure for Application of Industries)

  • 전성민;;이강산;이재랑;김광득;박영옥
    • 한국대기환경학회지
    • /
    • 제32권4호
    • /
    • pp.384-393
    • /
    • 2016
  • In this study, two kinds of industrial filter bags were tested for their filtration performance to apply the existing bag filter systems. Experimental variables were examined for pressure drop, cleaning interval, residual pressure drop, cleaning efficiency, fractional grade efficiency, total collection efficiency according to the filter bag structure. According to these results, the filter bags tested in this study demonstrated good performance in dust collection. This was also true for the double surface filter bag. The lifetime was longer than the round type filter bag because the filtration area was more than 1.6 times wider and the filter quality factor was much higher. Therefore, double surface filter bags are suggested to be used in order to increase filtration performance of the bag filter systems.

다양한 형상의 판형 열교환기 열전달 성능에 관한 해석적 연구 (Theoretical Study on the Heat Transfer Performance in the Various Type Plate Heat Exchanger)

  • 오재경;안성국;남상철;조홍현
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.636-645
    • /
    • 2012
  • The performance of various type plate exchangers with different chevron angle, dimple size and arrangement was analysed by using Ansys v13.0. Heat transfer performance, pressure drop and flow patten of plate heat exchanger were investigated according to mass flow ratio investigated and compared. As a result, the $60^{\circ}$-chevron type plate heat exchanger showed the highest heat transfer performance but pressure drop was relatively high. The efficiency of $45^{\circ}$-chevron type plate heat exchanger showed the best performance in considering of heat transfer performance and pressure drop simultaneously. Among dimple type plate heat exchangers, the highest heat transfer performance was shown in a dim_zigzag type plate heat exchanger but pressure drop was very high. Besides, the dim_upsize plate heat exchanger showed very low pressure drop.

루버형과 파형핀 열교환기에서 분진이 성능에 미치는 영향에 관한 연구 (A Study of Dust Effect on Performance of Heat Exchangers with Louver and Wavy Fins)

  • 이영림;황순호
    • 한국자동차공학회논문집
    • /
    • 제17권4호
    • /
    • pp.126-132
    • /
    • 2009
  • Automotive heat exchangers use louver fins for their high efficiency. However, the efficiency can significantly drop for constructional vehicles or heavy equipments due to dust deposited on the louver fins with narrow slits. Thus it is necessary to develop new fins that lead to less fouling, so that a better performance can be achieved after exposure to a dusty environment over long period of time. New wavy fins were considered in the study and numerically analysed to compare with louver fins in the areas of air-side pressure drop, heat release rate, and particulate deposition. In addition, an experiment was done on the pressure drop and the particulate deposition. The results showed that the wavy fins would be a better choice for long-term use due to the excellent dust-proof performance in comparison to louver fins, in spite of the initial inferior performance of heat release.

에어-드롭 해머와 카운터블로 해머 프레스 단조공정의 기계진동 비교해석 (Comparative Analysis of Mechanical Vibrations of an Air-Drop Hammer and a Counterblow Hammer in Forging Process)

  • 김수태;최영휴;주경진
    • 드라이브 ㆍ 컨트롤
    • /
    • 제19권4호
    • /
    • pp.10-18
    • /
    • 2022
  • Air-drop hammer press and counterblow hammer press are widely used power-drop forging hammersemploying different forging blow mechanisms. It is important and necessary to analyze mechanical vibrations of these two different hammers in their forging processes in order to develop high performance forging hammers. In this study, these two forging hammers were mathematically modelled as mass-spring-damper systems. For these two different types of forging hammers, the forging efficiency and mechanical vibrations due to hammer forging blow were theoretically analyzed and compared. The force transmitted to the ground was also determined and compared. Especially, effects of mass ratio and restitution coefficient on forging efficiency were investigated.

내부 분할된 단순확장관의 투과손실 및 배압 전산해석 (Transmission Loss and Back-pressure Analysis for Inner-separated Muffler)

  • 정의봉;김연우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.687-689
    • /
    • 2014
  • This paper deals with the optimal muffler model by using acoustic analysis and CFD(computational fluid dynamics) analysis. The complicated muffler model could be better noise reduction performance. However, it could be worse affected to back-pressure performance by pressure drop in working fluid. High back-pressure is caused to low system efficiency. Therefore, it is important for the muffler design to consider the pressure drop. The muffler models are changed their partition plate position. Acoustic power transmission loss(TL) and pressure drop of working fluid are calculated by using computational analysis and used to build database for finding their trends. The optimal muffler model in user-interested frequency range could be selected by analyzing this database.

  • PDF

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • 한국입자에어로졸학회지
    • /
    • 제8권4호
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

청소기용 Cyclone 소음원 및 저감방법 (Noise Reduction Method and Sources of Cyclone Sound for Vacuum Cleaner)

  • 이준화;홍승기;주재만;오상경;송화규;오장근
    • 한국소음진동공학회논문집
    • /
    • 제15권4호
    • /
    • pp.452-456
    • /
    • 2005
  • Cyclone is widely adopted in the vacuum cleaner, because of the simple structure, the high dust collection efficiency and its transparency feature, which can be shown to the customer. At past times, cyclone performance was represented by collection efficiency, flow rate, pressure drop etc. At recent times the noise problem is getting important as cyclone comes into home-appliances. In this paper, pressure drop of cyclone and it's noise were measured at the variation of the cyclone structure and the main sources of cyclone peak noise was found by experimental and numerical analysis. In addition, the structure for peak noise reduction was suggested and it is beneficial both pressure drop and noise reduction.