• Title/Summary/Keyword: Performance amplification

Search Result 268, Processing Time 0.02 seconds

Improvement of RocksDB Performance via Large-Scale Parameter Analysis and Optimization

  • Jin, Huijun;Choi, Won Gi;Choi, Jonghwan;Sung, Hanseung;Park, Sanghyun
    • Journal of Information Processing Systems
    • /
    • v.18 no.3
    • /
    • pp.374-388
    • /
    • 2022
  • Database systems usually have many parameters that must be configured by database administrators and users. RocksDB achieves fast data writing performance using a log-structured merged tree. This database has many parameters associated with write and space amplifications. Write amplification degrades the database performance, and space amplification leads to an increased storage space owing to the storage of unwanted data. Previously, it was proven that significant performance improvements can be achieved by tuning the database parameters. However, tuning the multiple parameters of a database is a laborious task owing to the large number of potential configuration combinations. To address this problem, we selected the important parameters that affect the performance of RocksDB using random forest. We then analyzed the effects of the selected parameters on write and space amplifications using analysis of variance. We used a genetic algorithm to obtain optimized values of the major parameters. The experimental results indicate an insignificant reduction (-5.64%) in the execution time when using these optimized values; however, write amplification, space amplification, and data processing rates improved considerably by 20.65%, 54.50%, and 89.68%, respectively, as compared to the performance when using the default settings.

Design and Performance Evaluation of Extension-Type Actuators with a Displacement Amplification Mechanism Based on Chevron Beam

  • Jo, Yehrin;Lee, Euntaek;Kim, Yongdae
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.6
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a new design of an extension-type actuator (ExACT) is proposed based on a chevron structure with displacement amplification mechanisms by local heating. ExACT comprises diamond-shaped displacement amplification structures (DASs) containing axially oriented V-shaped chevron beams, a support bar that restricts lateral heat deformation, and a loading slot for thin-film heaters. On heating the thin film heater, the diamond-shaped DASs undergo thermal expansion. However, lateral expansion is restricted by the support bar, leading to displacement amplification in the axial direction. The performance parameters of ExACT such as temperature distribution and extended displacement is calculated using thermo-mechanical analysis methods with the finite element method (FEM) tool. Subsequently, the ExACTs are fabricated using a polymer-based 3D printer capable of reproducing complex structures, and the performance of ExACTs is evaluated under various temperature conditions. Finally, the performance evaluation results were compared with those of the FEM analysis.

Experimental investigation of jet pump performance used for high flow amplification in nuclear applications

  • Vimal Kotak;Anil Pathrose;Samiran Sengupta;Sugilal Gopalkrishnan;Sujay Bhattacharya
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3549-3558
    • /
    • 2023
  • The jet pump can be used in a test device of a nuclear reactor for high flow amplification as it reduces inlet flow requirement and thereby size of the process components. In the present work, a miniature jet pump was designed to meet high flow amplification greater than 3. Subsequently, experiments were carried out using a test setup for design validation and performance evaluation of the jet pump for different parameters. It was observed that a minimum pressure of 0.6 bar (g) was required for the secondary fluid inside the jet pump to ensure cavitation free performance at high amplification. Spacing between the nozzle tip and the mixing chamber entry point had significant effect on the performance of the jet pump. Variation in primary flow, temperature and area ratio also affected the performance. It was observed that at high flow amplification, the analytical solution differed significantly from experimental results due to very large velocities encountered in the miniature size jet pump.

Experimental Performance Evaluation of Displacement Amplification Damping Systems Using Cables and Pulleys (케이블과 도르래를 이용한 변위증폭형 감쇠시스템의 실험적 성능평가)

  • Oh, Jintak;Jung, In Yong;Ryu, Jaeho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.149-156
    • /
    • 2020
  • The vibration control device such as the damper can be used to reinforce the seismic performance of structures. The damper is activated by the deformation of structures during earthquake; however, the deformation of structures is extremely small, causing difficulty in using the damper. Therefore, there is a need for a method capable of amplifying small deformities and transmitting them to the damper. The purpose of this paper is to develop and evaluate a displacement amplification seismic system using cable-pulley. The appropriate cable was selected through a cable tensile performance test and the results of the frame experiment were compared with theoretical displacement amplification ratio values. As a result, it may be said that the proposed system using cable-pulley is useful for displacement amplification.

Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes (구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수)

  • Eem, Seung-Hyun;Choi, In-Kil;Jeon, Bub-Gyu;Kwag, Shinyoung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.24 no.3
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Design and Performance Evaluation of Retraction-Type Actuators with Displacement Amplification Mechanism Based on Thermomechanical Metamaterial

  • Cho, Yelin;Lee, Euntaek;Kim, Yongdae
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.2
    • /
    • pp.28-35
    • /
    • 2020
  • In this paper, we present a design for a retraction-type actuator (ReACT) that has the characteristics of both thermomechanical metamaterials and displacement amplification mechanisms. The ReACT consists of an actuating bar, a diamond-shaped displacement amplification (DA) structure, and a slot for loading thin-film heaters formed through the actuating bar. When power is supplied to the thin film heater, the actuating bars contacting the heater thermally expand, and the diamond-shaped DA structures retract in the longitudinal direction. The performance characteristics of the ReACT, such as temperature distribution and retracting displacement, were calculated with thermomechanical analysis methods using the finite element method (FEM). Subsequently, the ReACTs were fabricated using a polymer-based 3D printer that can easily execute complex structures, and the performance of the ReACT was evaluated through repeated tests under various temperature conditions. The results of the performance evaluation were compared with the results of the FEM analysis.

Study on the Seismic Performance for Low-rised RC Building with Vertical and Torsional Irregularities (수직비정형과 비틀림비정형을 동시에 가지는 저층 RC 건물의 내진성능에 관한 연구)

  • Choi, In-Hyuk;Baek, Eun-Rim;Lee, Sang-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.12
    • /
    • pp.137-148
    • /
    • 2019
  • Korean piloti-type buildings are comprised of pilotis in the first story and shear walls in the upper stories. This vertical irregularity causes excessive lateral plastic deformation on the first story while the upper stories stay elastic. Meanwhile, asymmetric position of structural components such as core walls and columns of RC piloti-type buildings tends to produce torsional irregularities of the structures. Korean Building Code(KBC2016) requires the special seismic load and torsional amplification factor to apply to the piloti-type buildings lower than six-story or 20m if it has vertical and torsional irregularities when the building corresponds to seismic design category C or D. Many Korean low-rised RC buildings fall into the class. Therefore, the special earthquake load and torsional amplification factor are often applied to a building simultaneously. However, it has not been studied enough how much influence each parameter has on buildings with vertical and torsional irregularities at the same time. The purpose of this study is to evaluate the effect of factor special seismic load and torsional amplification on seismic performance of irregular buildings. In this study, a damaged 4th story piloti-type building by the Pohang earthquake was selected and the earthquake response analysis was carried out with various seismic design methods by the KBC 2016. The effect of the design parameters on seismic performance was analyzed by the dynamic analysis of models with special seismic load and torsional amplification factor based on the selected building. It was concluded that the application of the torsional amplification factor to the reference model to which special seismic design was applied, does not significantly affect the seismic performance.

Performance of privacy Amplification in Quantum Key Distribution Systems (양자 키 분배 시스템에서 보안성 증폭의 성능 분석)

  • Lee, Sun-Yui;Kim, Jin-Young
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.111-116
    • /
    • 2018
  • This paper introduces the concept of a random universal hash function to amplify security in a quantum key distribution system. It seems to provide security amplification using the relationship between quantum error correction and security. In addition, the approach in terms of security amplification shows that phase error correction offers better security. We explain how the universal hash function enhances security using the BB84 protocol, which is a typical example of QKD(Quantum Key Distribution). Finally, we show that the BB84 protocol using random privacy amplification is safe at higher key rates than Mayers' performance at the same error rate.

Design and Fabrication of wideband low-noise amplification stage for COMINT (통신정보용 광대역 저잡음 증폭단 설계 및 구현)

  • Go, Min-Ho
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.7 no.2
    • /
    • pp.221-226
    • /
    • 2012
  • In this paper, wideband two-stage amplification stage was designed, fabricated and evaluated. The proposed amplification stage with a novel gain control method have a high gain, low noise and high linearity performance. It is consisted of common emitter amplifier as the first stage, cascode gain control amplifier as second stage and power detector which sense the received signal strength. The proposed amplification stage shows a total gain of 29 dB~37 dB, noise fiugre of 1.5 dB at operating band and high linearity performance as the IMD (third intermodulation distortion) level is below the noise level of the measurement equipment at the control voltage 2.0 V generated from power detector under the strong electric field condition.

A Study on the Amplification Block for Integrated Antenna Module Applicable to Vehicles (차량용 통합 안테나 모듈용 증폭단에 관한 연구)

  • Go, Min-Ho;Pyo, Seung-Chul;Park, Hyo-Dal
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.4 no.2
    • /
    • pp.87-92
    • /
    • 2009
  • In this paper, we designed and fabricated the active amplification block for the integrated antenna module. The fabricated amplification module have a proper gain and low noise figure in the band of AM/FM band, T-DMB band and GPS band, and show good isolation performance for each band. Manufactured circuits satisfied the gain performance 7 dB in AM band, 11 dB in FM band, 10 dB in T-DMB, and 17 dB in GPS band. The integrated amplification block was realized by 35 mm*35 mm size, and was shown as the same sensitivity performance as compared with a conventional reference antennas.

  • PDF