• 제목/요약/키워드: Performance amplification

검색결과 268건 처리시간 0.023초

Improvement of RocksDB Performance via Large-Scale Parameter Analysis and Optimization

  • Jin, Huijun;Choi, Won Gi;Choi, Jonghwan;Sung, Hanseung;Park, Sanghyun
    • Journal of Information Processing Systems
    • /
    • 제18권3호
    • /
    • pp.374-388
    • /
    • 2022
  • Database systems usually have many parameters that must be configured by database administrators and users. RocksDB achieves fast data writing performance using a log-structured merged tree. This database has many parameters associated with write and space amplifications. Write amplification degrades the database performance, and space amplification leads to an increased storage space owing to the storage of unwanted data. Previously, it was proven that significant performance improvements can be achieved by tuning the database parameters. However, tuning the multiple parameters of a database is a laborious task owing to the large number of potential configuration combinations. To address this problem, we selected the important parameters that affect the performance of RocksDB using random forest. We then analyzed the effects of the selected parameters on write and space amplifications using analysis of variance. We used a genetic algorithm to obtain optimized values of the major parameters. The experimental results indicate an insignificant reduction (-5.64%) in the execution time when using these optimized values; however, write amplification, space amplification, and data processing rates improved considerably by 20.65%, 54.50%, and 89.68%, respectively, as compared to the performance when using the default settings.

Design and Performance Evaluation of Extension-Type Actuators with a Displacement Amplification Mechanism Based on Chevron Beam

  • Jo, Yehrin;Lee, Euntaek;Kim, Yongdae
    • 항공우주시스템공학회지
    • /
    • 제15권6호
    • /
    • pp.1-9
    • /
    • 2021
  • In this study, a new design of an extension-type actuator (ExACT) is proposed based on a chevron structure with displacement amplification mechanisms by local heating. ExACT comprises diamond-shaped displacement amplification structures (DASs) containing axially oriented V-shaped chevron beams, a support bar that restricts lateral heat deformation, and a loading slot for thin-film heaters. On heating the thin film heater, the diamond-shaped DASs undergo thermal expansion. However, lateral expansion is restricted by the support bar, leading to displacement amplification in the axial direction. The performance parameters of ExACT such as temperature distribution and extended displacement is calculated using thermo-mechanical analysis methods with the finite element method (FEM) tool. Subsequently, the ExACTs are fabricated using a polymer-based 3D printer capable of reproducing complex structures, and the performance of ExACTs is evaluated under various temperature conditions. Finally, the performance evaluation results were compared with those of the FEM analysis.

Experimental investigation of jet pump performance used for high flow amplification in nuclear applications

  • Vimal Kotak;Anil Pathrose;Samiran Sengupta;Sugilal Gopalkrishnan;Sujay Bhattacharya
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3549-3558
    • /
    • 2023
  • The jet pump can be used in a test device of a nuclear reactor for high flow amplification as it reduces inlet flow requirement and thereby size of the process components. In the present work, a miniature jet pump was designed to meet high flow amplification greater than 3. Subsequently, experiments were carried out using a test setup for design validation and performance evaluation of the jet pump for different parameters. It was observed that a minimum pressure of 0.6 bar (g) was required for the secondary fluid inside the jet pump to ensure cavitation free performance at high amplification. Spacing between the nozzle tip and the mixing chamber entry point had significant effect on the performance of the jet pump. Variation in primary flow, temperature and area ratio also affected the performance. It was observed that at high flow amplification, the analytical solution differed significantly from experimental results due to very large velocities encountered in the miniature size jet pump.

케이블과 도르래를 이용한 변위증폭형 감쇠시스템의 실험적 성능평가 (Experimental Performance Evaluation of Displacement Amplification Damping Systems Using Cables and Pulleys)

  • 오진탁;정인용;류재호
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.149-156
    • /
    • 2020
  • The vibration control device such as the damper can be used to reinforce the seismic performance of structures. The damper is activated by the deformation of structures during earthquake; however, the deformation of structures is extremely small, causing difficulty in using the damper. Therefore, there is a need for a method capable of amplifying small deformities and transmitting them to the damper. The purpose of this paper is to develop and evaluate a displacement amplification seismic system using cable-pulley. The appropriate cable was selected through a cable tensile performance test and the results of the frame experiment were compared with theoretical displacement amplification ratio values. As a result, it may be said that the proposed system using cable-pulley is useful for displacement amplification.

구조물 및 기기의 내진성능 평가를 위한 고주파수 지진에 의한 원자력발전소의 지진응답 증폭계수 (Seismic Response Amplification Factors of Nuclear Power Plants for Seismic Performance Evaluation of Structures and Equipment due to High-frequency Earthquakes)

  • 임승현;최인길;전법규;곽신영
    • 한국지진공학회논문집
    • /
    • 제24권3호
    • /
    • pp.123-128
    • /
    • 2020
  • Analysis of the 2016 Gyeongju earthquake and the 2017 Pohang earthquake showed the characteristics of a typical high-frequency earthquake with many high-frequency components, short time strong motion duration, and large peak ground acceleration relative to the magnitude of the earthquake. Domestic nuclear power plants were designed and evaluated based on NRC's Regulatory Guide 1.60 design response spectrum, which had a great deal of energy in the low-frequency range. Therefore, nuclear power plants should carry out seismic verification and seismic performance evaluation of systems, structures, and components by reflecting the domestic characteristics of earthquakes. In this study, high-frequency amplification factors that can be used for seismic verification and seismic performance evaluation of nuclear power plant systems, structures, and equipment were analyzed. In order to analyze the high-frequency amplification factor, five sets of seismic time history were generated, which were matched with the uniform hazard response spectrum to reflect the characteristics of domestic earthquake motion. The nuclear power plant was subjected to seismic analysis for the construction of the Korean standard nuclear power plant, OPR1000, which is a reactor building, an auxiliary building assembly, a component cooling water heat exchanger building, and an essential service water building. Based on the results of the seismic analysis, a high-frequency amplification factor was derived upon the calculation of the floor response spectrum of the important locations of nuclear power plants. The high-frequency amplification factor can be effectively used for the seismic verification and seismic performance evaluation of electric equipment which are sensitive to high-frequency earthquakes.

Design and Performance Evaluation of Retraction-Type Actuators with Displacement Amplification Mechanism Based on Thermomechanical Metamaterial

  • Cho, Yelin;Lee, Euntaek;Kim, Yongdae
    • 항공우주시스템공학회지
    • /
    • 제14권2호
    • /
    • pp.28-35
    • /
    • 2020
  • In this paper, we present a design for a retraction-type actuator (ReACT) that has the characteristics of both thermomechanical metamaterials and displacement amplification mechanisms. The ReACT consists of an actuating bar, a diamond-shaped displacement amplification (DA) structure, and a slot for loading thin-film heaters formed through the actuating bar. When power is supplied to the thin film heater, the actuating bars contacting the heater thermally expand, and the diamond-shaped DA structures retract in the longitudinal direction. The performance characteristics of the ReACT, such as temperature distribution and retracting displacement, were calculated with thermomechanical analysis methods using the finite element method (FEM). Subsequently, the ReACTs were fabricated using a polymer-based 3D printer that can easily execute complex structures, and the performance of the ReACT was evaluated through repeated tests under various temperature conditions. The results of the performance evaluation were compared with the results of the FEM analysis.

수직비정형과 비틀림비정형을 동시에 가지는 저층 RC 건물의 내진성능에 관한 연구 (Study on the Seismic Performance for Low-rised RC Building with Vertical and Torsional Irregularities)

  • 최인혁;백은림;이상호
    • 대한건축학회논문집:구조계
    • /
    • 제35권12호
    • /
    • pp.137-148
    • /
    • 2019
  • Korean piloti-type buildings are comprised of pilotis in the first story and shear walls in the upper stories. This vertical irregularity causes excessive lateral plastic deformation on the first story while the upper stories stay elastic. Meanwhile, asymmetric position of structural components such as core walls and columns of RC piloti-type buildings tends to produce torsional irregularities of the structures. Korean Building Code(KBC2016) requires the special seismic load and torsional amplification factor to apply to the piloti-type buildings lower than six-story or 20m if it has vertical and torsional irregularities when the building corresponds to seismic design category C or D. Many Korean low-rised RC buildings fall into the class. Therefore, the special earthquake load and torsional amplification factor are often applied to a building simultaneously. However, it has not been studied enough how much influence each parameter has on buildings with vertical and torsional irregularities at the same time. The purpose of this study is to evaluate the effect of factor special seismic load and torsional amplification on seismic performance of irregular buildings. In this study, a damaged 4th story piloti-type building by the Pohang earthquake was selected and the earthquake response analysis was carried out with various seismic design methods by the KBC 2016. The effect of the design parameters on seismic performance was analyzed by the dynamic analysis of models with special seismic load and torsional amplification factor based on the selected building. It was concluded that the application of the torsional amplification factor to the reference model to which special seismic design was applied, does not significantly affect the seismic performance.

양자 키 분배 시스템에서 보안성 증폭의 성능 분석 (Performance of privacy Amplification in Quantum Key Distribution Systems)

  • 이선의;김진영
    • 한국인터넷방송통신학회논문지
    • /
    • 제18권5호
    • /
    • pp.111-116
    • /
    • 2018
  • 본 논문은 양자 키 분배 시스템에서의 보안성을 증폭시키기 위한 유니버셜 랜덤 해쉬 함수의 개념을 소개하고 양자 오류 정정과 보안 사이의 관계를 이용하여 보안성 증폭을 제공하는 것을 보인다. 또한, 보안성 증폭 측면에서 접근 방식이 위상 오차 보정 방식을 소개하며 위상 오차 방식이 다른 방식보다 더 나은 보안성을 제시한다는 것을 보인다. 양자 키 분배의 대표적인 예인 BB84 프로토콜을 이용하여 유니버셜 해시 함수가 보안성을 강화하는 과정을 설명한다. 마지막으로 랜덤 프라이버시 증폭을 사용하는 BB84 프로토콜이 동일한 오류율을 가지는 Mayers의 성능보다 높은 키 레이트를 가지는 것을 보여 보안성이 강화된 것을 확인한다.

통신정보용 광대역 저잡음 증폭단 설계 및 구현 (Design and Fabrication of wideband low-noise amplification stage for COMINT)

  • 고민호
    • 한국전자통신학회논문지
    • /
    • 제7권2호
    • /
    • pp.221-226
    • /
    • 2012
  • 본 논문에서는 광대역 (400 MHz~2000 MHz) 2단 증폭단을 설계, 제작 및 측정하였다. 제안한 증폭단은 새로운 구조의 이득제어 방식을 적용하여 고이득, 저잡음지수 및 높은 선형성 특성을 구현하였다. 증폭단은 공통 에미터 구조의 초단 증폭기 및 캐스코드 구조의 가변이득 증폭기. 입력신호의 크기를 감지하는 전력감지회로로 구성하였다. 제안한 증폭단은 설계 대역에서 전체이득 29 dB~37 dB, 잡음지수 1.5 dB을 나타내었고, 강전계 입력 조건에서 전력감지회로에서 발생되는 제어전압 2.0V인 조건에서 3차 상호변조 왜곡 신호의 크기는 측정 장비의 잡음레벨 보다 낮은 특성을 나타내어 높은 선형성 특성을 나타내었다.

차량용 통합 안테나 모듈용 증폭단에 관한 연구 (A Study on the Amplification Block for Integrated Antenna Module Applicable to Vehicles)

  • 고민호;표승철;박효달
    • 한국전자통신학회논문지
    • /
    • 제4권2호
    • /
    • pp.87-92
    • /
    • 2009
  • 본 논문에서는 통합 안테나 모듈에 사용되는 능동 증폭단을 설계, 제작하였다. 제작한 통합 능동모듈은 AM/FM 대역, T-DMB 대역 및 GPS 대역에서 적절한 이득과 낮은 잡음지수 특성을 나타내었고, 또한 각 회로간의 간섭이 최소화하도록 설계되었다. AM 및 FM 대역에서 7.0dB, 11.0 dB 이득 특성을 나타내고, T-DMB 및 GPS 대역에서 10.0 dB, 17.0 dB의 이득을 갖는다. 제작한 증폭단 모듈은 35mm*35 mm의 크기로 구현할 수 있었고, 이를 적용한 통합 안테나 모듈의 수신감도 또한 기준 안테나와 비교했을 때 동등한 특성을 나타내었다.

  • PDF