Frequency, Clinical Characteristics and Correlates of Premenstrual Syndrome in High School Students (여고생에서 월경전 증후군의 빈도와 임상적 특징 및 관련요인)

  • Chang, Hyung-Joo;Jeong, Hyun-Ghang;Ko, Young-Hoon;Han, Chang-Su;Joe, Sook-Haeng
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.21 no.1
    • /
    • pp.44-54
    • /
    • 2013
  • Objectives : To investigate the frequency and clinical characteristics of premenstrual syndrome(PMS)/premenstrual dysphoric disorder(PMDD) in high school students, and determine the correlates of PMS/PMDD in association with comorbid depression and anxiety. Methods : A total of 1688 students were recruited from 5 high schools in Seoul, Korea. Subjects completed the questionnaire composed of scales to measure premenstrual symptoms, depression, and anxiety, as well as sociodemographic and reproductive variables. Subjects were categorized into 3 groups by using the Premenstrual Symptom Screening Tool(PSST) to determine the frequency and clinical characteristics of PMS/PMDD. Multivariate logistic regression was used to identify the correlates of PMS/PMDD. Results : The frequency of moderate to severe PMS and PMDD was 20.1% and 6.4%, respectively. Irritability(78.8%), fatigue(76.4%), and emotional sensitivity(69.8%) were common premenstrual symptoms, and functional impairment in academic performance(67.1%) was dominant. Dysmenorrhea[odd ratio(OR)=3.68, 95% confidence interval(CI) 2.45-5.55], family history of PMS(OR=1.91, 95% CI 1.35-2.71), and use of oral contraceptive (OR=1.85, 95% CI 1.16-2.94) were associated with the increased risk of PMS/PMDD after adjustment for depression and anxiety. Negative attitude to menses(OR=15.60, 95% CI 3.61-67.42) was associated with the increased risk of PMS/PMDD, particularly in subjects without depression and anxiety. Conclusions : PMS was common, as the frequency of PMS more than moderate severity including PMDD exceeded 25%, and disrupted daily functioning in adolescents. PMS is associated with various sociodemographic and menstrual characteristics, and these associations are affected by comorbid depression and anxiety.

  • PDF

New Analytical Method to Identify Chromium Species, Cr(III) and Cr(VI), and Characteristic Distribution of Chromium Species in the Han River (한강수계해서의 크롬(III,VI) 종(species) 분포 및 분석방법 정립)

  • Jeong, Gwan-Jo;Kim, Dok-Chan;Park, Hyeon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.590-598
    • /
    • 2005
  • An adequate method to identify chromium separation, Cr(III) and Cr(VI), in water samples were studied by using High Performance Liquid Chromatography(HPLC) coupled with Inductively Coupled Plasma Mass Spectometer(ICP-MS) equipped with Dynamic Reaction Cell(DRC). The characteristic distribution of Cr(III) and Cr(VI) in the raw water taken at the six water intake stations in Seoul, was analyzed by the method developed by the authors. The chromium species separated by HPLC was isocratically conducted by using tetrabutylammonium phosphate monobasic(1.0 mM TBAP), ethylenediaminetetraacetic acid(0.6 mM EDTA) and 2% v/v methanol as the mobile phase. 5% v/v methanol was used as flushing solvent. A reactive ammonia($NH_3$) gas was used to eliminate the potential interference of $ArC^+$. Several Parameters such as solvent ratio, pH, flow rate and sample injection volume were optimized for the successful separation and reproducibility. Although it has been reported thai the separation sensitivity of Cr(III) is superior to that of Cr(VI), the authors observed Cr(VI) was more sensitive than Cr(III) when ammonia($NH_3$) gas was used as the reaction gas. It took less than 3 minutes to analyze chromium species with this method and the estimated detection limits were $0.061\;{\mu}g/L$ for Cr(III) and $0.052\;{\mu}g/L$, for Cr(VI). According to the results from the analysis on chromium species in the raw water of the six intake stations, the concentrations of Cr(III) ranged from 0.048 to $0.064\;{\mu}g/L$(ave. $0.054\;{\mu}g/L$) while that of Cr(VI) ranged from 0.014 to $0.023\;{\mu}g/L$(ave. $0.019\;{\mu}g/L$). Recovery ratio was very high($90.1{\sim}94.1%$). There were two or three times more Cr(III) than Cr(VI) in the raw water.

Immunohistochemical Study of Phosphatase and Tensin Homolog Deleted on Chromosome Ten in Gefitinib Treated Nonsmall Cell Lung Cancer Patients (폐암 조직에서의 PTEN 발현 정도와 Gefitinib의 반응율과의 관계)

  • Lee, Sung Yong;Lee, Ju Han;Jung, Jin Yong;Lee, Kyoung Ju;Lee, Seung Hyeun;Kim, Se Joong;Lee, Eun Joo;Hur, Gyu Young;Jung, Ki Hwan;Jung, Hye Cheol;Lee, Sang Yeub;Kim, Je Hyeong;Shin, Chol;Shim, Jae Jeong;In, Kwang Ho;Kang, Kyung Ho;Yoo, Se Hwa
    • Tuberculosis and Respiratory Diseases
    • /
    • v.58 no.5
    • /
    • pp.473-479
    • /
    • 2005
  • Background : Gefitinib targets the epidermal growth factor receptor r(EGFR), and Gefitinib has antitumor activity in patient with non-small cell lung cancer (NSCLC). However, only 10 to 20 percent of patients show a clinical response to this drug, and the molecular mechanisms underlying patient sensitivity to gefitinib are unknown. PTEN (Phosphatase and tensin homolog deleted on chromosome Ten) plays a role for the modulation of the phosphatidylinositol 3-kinase pathway (PI3K), which is involved in cell proliferation and survival, so that it can inhibit cell cycle progression and induce G1 arrest. Therefore, we analyzed the relationship between PTEN expression and gefitinib's responsiveness in patients having advanced non small cell lung cancer that had progressed after previous chemotherapy. Methods : The expression of PTEN was studied by immunohistochemistry in paraffin-embedded tumor blocks that were obtained from 22 patients who had been treated with gefitinib from JAN, 2001 to AUG. 2004. For the evaluation of the relationships between the PTEN expression, the clinical stage and the basal characteristics, those cases that showed the respective antigen expression in >50% of the tumor cells were considered positive. Results : The positive rate of PTEN staining was 55% of the total of 22 patients. There was a significant relationship between the increased expression of PTEN and the response group (p=0.039). However, there was no significant relationship between the expression of PTEN and other clinicopathologic characteristics. Conclusion: The expression of PTEN in patients with advanced non small cell lung cancer that has progressed after previous chemotherapy may play a role in gefitinib's responsiveness.

Definition of Tumor Volume Based on 18F-Fludeoxyglucose Positron Emission Tomography in Radiation Therapy for Liver Metastases: An Relational Analysis Study between Image Parameters and Image Segmentation Methods (간 전이 암 환자의 18F-FDG PET 기반 종양 영역 정의: 영상 인자와 자동 영상 분할 기법 간의 관계분석)

  • Kim, Heejin;Park, Seungwoo;Jung, Haijo;Kim, Mi-Sook;Yoo, Hyung Jun;Ji, Young Hoon;Yi, Chul-Young;Kim, Kum Bae
    • Progress in Medical Physics
    • /
    • v.24 no.2
    • /
    • pp.99-107
    • /
    • 2013
  • The surgical resection was occurred mainly in liver metastasis before the development of radiation therapy techniques. Recently, Radiation therapy is increased gradually due to the development of radiation dose delivery techniques. 18F-FDG PET image showed better sensitivity and specificity in liver metastasis detection. This image modality is important in the radiation treatment with planning CT for tumor delineation. In this study, we applied automatic image segmentation methods on PET image of liver metastasis and examined the impact of image factors on these methods. We selected the patients who were received the radiation therapy and 18F-FDG PET/CT in Korea Cancer Center Hospital from 2009 to 2012. Then, three kinds of image segmentation methods had been applied; The relative threshold method, the Gradient method and the region growing method. Based on these results, we performed statistical analysis in two directions. 1. comparison of GTV and image segmentation results. 2. performance of regression analysis for relation between image factor affecting image segmentation techniques. The mean volume of GTV was $60.9{\pm}65.9$ cc and the $GTV_{40%}$ was $22.43{\pm}35.27$ cc, and the $GTV_{50%}$ was $10.11{\pm}17.92$ cc, the $GTV_{RG}$ was $32.89{\pm}36.8$4 cc, the $GTV_{GD}$ was $30.34{\pm}35.77$ cc, respectively. The most similar segmentation method with the GTV result was the region growing method. For the quantitative analysis of the image factors which influenced on the region growing method, we used the standardized coefficient ${\beta}$, factors affecting the region growing method show GTV, $TumorSUV_{MAX/MIN}$, $SUV_{max}$, TBR in order. The result of the region growing (automatic segmentation) method showed the most similar result with the CT based GTV and the region growing method was affected by image factors. If we define the tumor volume by the auto image segmentation method which reflect the PET image parameters, more accurate and consistent tumor contouring can be done. And we can irradiate the optimized radiation dose to the cancer, ultimately.

Development of a Method for Analyzing the Nicotine Content in Synthetic Flavoring Substances as Unauthorized E-cigarette Liquid by Using HPLC (전자담배 액상 충진제와 유사한 합성착향료 중 니코틴의 HPLC 분석법 개발)

  • Kim, Jae-Young;Lee, Sang-Mok;Chang, Moon-Ik;Cho, Yoon-Jae;Lee, Han-Jin;Chae, Young-Sik;Rhee, Gyu-Sik
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.6
    • /
    • pp.693-699
    • /
    • 2013
  • A simple, sensitive, and specific method for quantifying the nicotine content of synthetic favoring substances (SFS) was developed using high performance liquid chromatography (HPLC) with a photo-diode array detector (PDA). Nicotine was extracted from SFS samples by using an acid-base liquid-liquid extraction method with dichloromethane and distilled water. The nicotine content was quantified by HPLC/PDA (261.9 nm) with a $C_{18}$ column under a gradient of 10% acetonitrile with 20 mM ammonium formate (ammonia solution adjusted to pH 8.7) to 100% acetonitrile. The calibration curve, analyzed from concentration standards between 0.1 to 2 mg/L, presented linearity with a correlation coefficient ($r^2$)>0.9999. The limit of quantitation (LOQ) of nicotine in SFS was 0.4 mg/kg, and the average recoveries ranged from 76.4% to 96.3%. The repeatability of measurements, expressed as the coefficient of variation (CV%), ranged from 1.74 to 5.12%. This newly developed method for nicotine quantification in SFS can be considered an analytical method with an acceptable level of sensitivity and repeatability.

A Low-Dose High-Resolution SPECT System with CdTe for Small-Animal Imaging Applications: A GATE Simulation Study (GATE 시뮬레이션을 통한 고해상도 저선량용 소동물 영상화를 위한 CdTe 검출기 기반의 SPECT 기기 연구)

  • Park, Su-Jin;Yu, A Ram;Kim, Yeseul;Lee, Young-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.24 no.3
    • /
    • pp.162-170
    • /
    • 2013
  • Dedicated single-photon emission computed tomography (SPECT) systems based on pixelated semiconductors are being developed for studying small animal models of human disease. To clarify the possibility of using a SPECT system with CdTe for a high resolution low-dose small animal imaging, we compared the quality of reconstructed images from pixelated CdTe detector to those from a small SPECT system with NaI(Tl). The CdTe detector was $44.8{\times}44.8$ mm and the pixels were $0.35{\times}0.35{\times}5$ mm. The intrinsic resolution of the detector was 0.35 mm, which is equal to the pixel size. GATE simulations were performed to assess the image quality of both SPECT systems. The spatial resolutions and sensitivities for both systems were evaluated using a 10 MBq $^{99m}Tc$ point source. The quantitative comparison with different injected dose was performed using a voxelized MOBY phantom, and the absorbed doses for each organ were evaluated. The spatial resolution of the SPECT with NaI(Tl) was about 1.54 mm FWHM, while that of the SPECT with a CdTe detector was about 1.32 mm FWHM at 30 mm. The sensitivity of NaI(Tl) based SPECT was 83 cps/MBq, while that of the CdTe detector based SPECT was 116 cps/MBq at 30 mm. The image statistics were evaluated by calculating the CNR of the image from both systems. When the injected activity for the striatum in the mouse brain was 160 Bq/voxel, the CNR of CdTe based SPECT was 2.30 while that of NaI(Tl) based SPECT was 1.85. The CNR of SPECT with CdTe was overall higher than that of the NaI(Tl) based SPECT. In addition, the absorbed dose was higher from SPECT with CdTe than those from NaI(Tl) based SPECT to acquire the same quantitative values. Our simulation results indicated that the SPECT with CdTe detector showed overall high performance compared to the SPECT with NaI(Tl). Even though the validation study is needed, the SPECT system with CdTe detector appeared to be feasible for high resolution low-dose small animal imaging.

The Relationship Between Perception of Prosody, Pitch Discrimination, and Melodic Contour Identification in Cochlear Implants Recipients (인공와우이식 난청인의 말소리 운율변화에 따른 구어 이해와 음도 변별, 선율윤곽 확인 간 관련성)

  • Kim, Eun Yeon;Moon, Il Joon;Cho, Yang-sun;Chung, Won-ho;Hong, Sung Hwa
    • Journal of Music and Human Behavior
    • /
    • v.14 no.2
    • /
    • pp.1-18
    • /
    • 2017
  • The relationships between the ability to understand changes in meaning depending on the prosody of spoken words and the ability to perceive pitch and melodic contour in cochlear implants (CI) recipients were examined. Fifteen postlingual CI recipients were measured in terms of speech prosody perception, speech perception, pitch discrimination (PD), and melody contour identification (MCI). The speech prosody perception test consists of words with positive (PW) and neutral meaning (NW). Participants were asked to identify the meaning of words depending on the conditions of positive and negative prosody. The MCI consists of subtests 1 and 2 with different chance levels to choose. Then, the relationships between speech prosody perception, speech perception, PD, and MCI performance were analyzed. There was a significant difference in identifying the meaning of words expressed in a different prosody between the PW and NW conditions. Speech prosody perception showed a significant correlation with MCI 1 while there was no significant relationship with speech perception. Although speech perception may be possible after CI, limited spoken word comprehension due to decreased sensitivity for prosodic changes may persist in CI recipients. In addition, there was a limitation in perception of melodic contour change compared to pitch discrimination, which is related to speech prosody perception.

Utility of polymerase chain reaction(PCR) according to sampling time in CSF and stool specimens from patient with aseptic meningitis (무균성 뇌막염 환자에서 뇌척수액과 대변 채취 시점에 따른 PCR의 유용성)

  • Kim, Myo Jing;Lee, Hye Jin;Choi, Jung Mi;Jung, Soo Jin;Huh, Jae Won
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.7
    • /
    • pp.745-750
    • /
    • 2006
  • Purpose : Enteroviruses are the most common cause of aseptic meningitis in patients of all ages. A definite diagnosis of enteroviral meningitis can be established by detection of virus directly in CSF specimens. But this is time-consuming and lacks sensitivity, so polymerase chain reaction(PCR) detecting of viral RNA in patient specimens such as CSF, stool has been demonstrated. But little is known about the influence of sampling time on the results of CSF PCR and stool PCR. We investigated diagnostic utility of PCR of CSF and stool according to sampling time after the onset of symptoms. Methods : PCR results were analyzed according to sampling time for 42 patients diagnosed aseptic meningits in our hospital from $11^{th}$ January to $30^{th}$ August, 2005. Results : The diagnostic yield of the test was higher of CSF specimens obtained ${\leq_-}2$ days after clinical onset(positive PCR results 9/18, 50 percent), compared with CSF collected >2 days after onset(positive PCR results 1/24, 4.2 percent)(P=0.001). Instead, positive PCR results of fecal specimens maintained highly(average 90.5 percent), 10 cases had also positive PCR results even 5-6 days after onset. 10 cases of CSF specimens had positive enterovirus PCR results containing coxsackievirus B5 (n=6), coxsackievirus B3(n=3). 38 cases of stool specimens had positive enterovirus PCR results containing echovirus 18(n=7), echovirus 9(n=3), coxsackievirus B5(n=8), coxsackievirus B3(n=3). 6 cases(coxackie B5) had positive CSF PCR and stool PCR, both. Conclusion : Stool PCR was clinically sensitive for detecting enterovirus during enteroviral meningits and could give a presumptive diagnosis throughout the disease course. A definite diagnosis was obtained by CSF PCR, but its utility was clearly lower for samples obtained >2 days after clinical onset. Therefore, it is recommended that, in addition to performance of CSF PCR, fecal samples obtained from patients with suspected enteroviral meningitis should be tested by PCR, especially when the duration of symptoms is >2 days.

The Usefulness of LEUR Collimator for 1-Day Basal/Acetazolamide Brain Perfusion SPECT (1-Day Protocol을 사용하는 Brain Perfusion SPECT에서 LEUR 콜리메이터의 유용성)

  • Choi, Jin-Wook;Kim, Soo-Mee;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo;Lee, Jae-Sung;Lee, Dong-Soo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • Purpose: Basal/Acetazolamide-challenged brain perfusion SPECT is very useful to assess cerebral perfusion and vascular reserve. However, as there is a trade off between sensitivity and spatial resolution in the selection of collimator, the selection of optimal collimator is crucial. In this study, we examined three collimators to select optimal one for 1-day brain perfusion SPECT. Materials and Methods: Three collimators, low energy high resolution-parallel beam (LEHR-par), ultra resolution-fan beam (LEUR-fan) and super fine-fan beam (LESFR-fan), were tested for 1-day imaging using Triad XLT 9 (TRIONIX). The SPECT images of Hoffman 3D brain phantom filled with 99mTc of 170 MBq and a normal volunteer were acquired with a protocol of 50 kcts/frame and detector rotation of 3 degree. Filterd backprojection (FBP) reconstruction with Butterworth filter (cut off frequencies, 0.3 to 0.5) was performed. The quantitative and qualitative assessments for three collimators were performed. Results: The blind tests showed that LESFR-fan provided the best image quality for Hoffman brain phantom and the volunteer. However, images for all the collimator were evaluated as 'acceptable'. On the other hand, in order to meet the equivalent signal-to-noise ratio (SNR), total acquisition time or radioactivity dose for LESFR-fan must have been increased up to almost twice of that for LEUR-fan and LEHR-par. The volunteer test indicated that total acquisition time could be reduced approximately by 10 to 14 min in clinical practice using LEUR-fan and LEHR-par without significant loss on image quality, in comparison with LESFR-fan. Conclusion: Although LESFR-fan provides the best image quality, it requires significantly more acquisition time than LEUR-fan and LEHR-par to provide reasonable SNR. Since there is no significant clinical difference between three collimators, LEUR-fan and LEHR-par can be recommended as optimal collimators for 1-day brain perfusion imaging with respect to image quality and SNR.

  • PDF

The Design and Fabrication of Conversion Layer for Application of Direct-Detection Type Flat Panel Detector (직접 검출형 평판 검출기 적용을 위한 변환층 설계 및 제작)

  • Noh, Si-Cheol;Kang, Sang-Sik;Jung, Bong-Jae;Choi, Il-Hong;Cho, Chang-Hoon;Heo, Ye-Ji;Yoon, Ju-Seon;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.1
    • /
    • pp.73-77
    • /
    • 2012
  • Recently, Interest to the photoconductor, which is used to flat form X-ray detector such as a-Se, $HgI_2$, PbO, CdTe, $PbI_2$ etc. is increasing. In this study, the film layer by using the photoconductive material with particle sedimentation was fabricated and evaluated. The quantization efficiency of the continuous X-ray with the 70 kVp energy bandwidth was analyzed by using the Monte Carlo simulation. With the results, the thickness of film with 64 % quantization efficiency was 180 ${\mu}m$ which is similar to the efficiency of 500 ${\mu}m$ a-Se film. And $HIg_2$ film has the high quantization efficiency of 74 % on 240 ${\mu}m$ thickness. The electrical characteristics of the 239 ${\mu}m$ $Hgl_2$ films produced by particle sedimentation were shown as very low dark current(under 10 $pA/mm^2$), and high sensitivity(19.8 mC/mR-sec) with 1 $V/{\mu}m$ input voltage. The SNR, which is influence to the contrast of X-ray image, was shown highly as 3,125 in low driving voltage on 0.8 $V/{\mu}m$. With the results of this study, the development of the low-cost, high-performance image detector with film could be possible by replacing the film produced by particle sedimentation instead to a-Se detector.