• Title/Summary/Keyword: Performance Rate

Search Result 16,811, Processing Time 0.042 seconds

A parametric study on the performance of heat pump using standing column well(SCW) (스탠딩컬럼웰(SCW)을 적용한 지열히트펌프의 성능에 대한 매개변수 연구)

  • Chang, Jae-Hoon;Park, Du-Hee
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.625-630
    • /
    • 2010
  • Parametric study was performed using the SCW numerical model for evaluating the performance of the SCW. The five ground related parameters, which are porosity, hydraulic conductivity, thermal conductivity, specific heat, geothermal gradient, and five SCW design parameters, which are pumping rate, well depth well diameter, dip tube diameter, bleeding rate, were used in the study. Numerical simulations were performed for short-term (24-hour) simulation. The study results indicate that the parameters that have important influence on the performance of SCW were hydraulic conductivity, thermal conductivity, geothermal gradient, pumping rate, and bleeding rate. Overall, this study showed that various factors had a cumulative influence on the performance of the SCW, and a numerical simulation can be used to accurately predict the performance of the SCW.

  • PDF

Modeling the impact of corrosion rate of stirrups on seismic performance of reinforced concrete columns

  • Abbas Ghasemi;Mohamad Sobhani
    • Earthquakes and Structures
    • /
    • v.24 no.3
    • /
    • pp.183-192
    • /
    • 2023
  • It is essential to properly understand the seismic behavior of reinforced concrete (RC) columns confined by stirrups that experience different corrosion rates. The current study investigated the effect of seismic performance indicators such as strength loss, energy dissipation rate, ductility and hysteresis damping on specimens and models for different stirrup corrosion rates. Analysis revealed the adverse effects of corrosion on the bond performance between the concrete and steel bars which affected the seismic performance of the columns. It was found that with increasing corrosion rate, ductility and energy dissipation of the specimens decreased. Compared with the uncorroded specimen, the ductility factor and energy dissipation decreased observably, by 22.89% and 60.64%, respectively. An attenuation relationship is proposed for the corrosion rate of the stirrups for different stirrup yield strengths, concrete compressive strengths, concrete covers and stirrup spacing.

Uncertainty Estimation Model for Heat Rate of Turbine Cycle (터빈 사이클 열소비율 정확도 추정 모델)

  • Choi, Ki-Sang;Kim, Seong-Kun;Choi, Kwang-Hee
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1721-1726
    • /
    • 2004
  • Heat rate is a representative index to estimate the performance of turbine cycle in nuclear power plant. Accuracy of heat rate calculation is dependent on the accuracy of measurement for plant status variables. Uncertainty of heat rate can be modeled using uncertainty propagation model. We developed practical estimation model of heat rate uncertainty using the propagation and regression model. The uncertainty model is used in the performance analysis system developed for the operating nuclear power plant.

  • PDF

A Study on the Performance Characteristics of an Absorption Chiller for Variable Cooling Water Flow Rate at Partial Load Conditions (흡수식 냉온수기의 부분부하에 따른 냉각수 변유량시 성능특성에 관한 연구)

  • 박찬우;조현철;강용태
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.1
    • /
    • pp.26-33
    • /
    • 2004
  • In general, an absorption chiller or heat pump is operated under the constant cooling water flow rate condition even though the system works with a partial load. The objective of this paper is to study the effect of the cooling water flow rates and the temperature of cooling water on the system performance to find the energy saving methode for the partial load operation of the double effect $H_2O$/LiBr absorption chiller. It is found that the performance of the system is sensitive to the temperature of cooling water than the cooling water flow rate, so the decrease of the performance due to reducing the cooling water flow rate can be overcome with the reduction of the cooling water temperature by 1$^{\circ}C$. The flow rate of the cooling water flow rate ranges from 50% to 100% of the flow rate at normal conditions with a partial load. It is also found that the operation cost of the cooling water pump and the cooling tower can be reduced by 23%.

Experimental performance characteristics of 1 kW commercial PEM fuel cell

  • Shubhaditya Kumar;Pranshu Shrivastava;Anil Kumar
    • Advances in Energy Research
    • /
    • v.8 no.4
    • /
    • pp.203-211
    • /
    • 2022
  • The aim of this paper is to analyze the performance of commercial fuel cell (rated capacity 1000W) with the help of resistive load and output power variation with change in H2 flow rate and calculate the maximum power point (MPP) of the proton exchange membrane (PEM) while changing AC and DC load respectively. The factors influencing the output power of a fuel cell are hydrogen flow rate, cell temperature, and membrane water content. The results show that when the H2 flow rate is changed from 11, 13, and 15 Lpm, MPP is increased from lower to higher flow rate. The power of the fuel cell is increased at the rate of 29% by increasing the flow rate from 11 to 15 lpm. This study will allow small-scale industries and residential buildings (in remote or inaccessible areas) to characterize the performance of PEMFC. Furthermore, fuel cell helps in reducing emission in the environment compared to fossil fuels. Also, fuel cells are ecofriendly as well as cost effective and can be the best alternative way to convert energy.

Three-dimensional Teleoperation Performance Measures: Their correlations and effects of task difficulty

  • Park, Sung Ha
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.2
    • /
    • pp.33-45
    • /
    • 2000
  • Present study was performed to compare different types of teleoperation performance measures. A modified Cooper-Harper rating scale and a distance measure were newly introduced and compared to two traditional measures, the error rate and time-to-completion. Participants performed a simulated telerobotic task with varying visual display interfaces. The results of correlation analyses revealed that the modified Cooper-Harper ratings had a close association with the error rate measure. The distance measure also appeared to be a consistent performance measure, which accounted for both the error rate and time-to-completion. A further analysis, however, showed that the effectiveness of each performance measure varied with the level of task difficulty. The results imply that the choice of performance measure should be made based on the task difficulty as well as the particular task being studied. The results revealed here also have implication for performance measures of various display and control systems including aircraft navigation displays and tactical displays.

  • PDF

Impact of Exchange Rate Shocks, Inward FDI and Import on Export Performance: A Cointegration Analysis

  • NGUYEN, Van Chien;DO, Thi Tuyet
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.4
    • /
    • pp.163-171
    • /
    • 2020
  • The study aims to examine the effects of inward every presence of foreign investment, import, and real exchange rate shocks on export performance in Vietnam. This study employs a time-series sample dataset in the period of 2009 - 2018. All data are collected from the General Statistics Office of Ministry of Planning and Investment in Vietnam, World Development Indicator and Ministry of Finance, State Bank of Vietnam. This study employs the Augmented Dickey-Fuller test and the vector error correction model with the analysis of cointegration. The results demonstrate that a higher value of import significantly accelerates export performance in the short run, but insignificantly generates in the long run. When the volume of registered foreign investment goes up, the export performance will predominantly decrease in the both short run and long run. Historically, countries worldwide are more likely to devaluate their currencies in order to support export performance. According to the study, the exchange rate volatility has an effect on the external trade in the long run but no effect in the short run. Finally, Vietnam's export performance converges on its long-run equilibrium by roughly 6.3% with the speed adjustment via a combination of import, every presence of foreign investment, and real exchange rate fluctuations.

The Decision-Making Types, Public Entrepreneurship and Performance Management of Local Public Hospital Directors (지방의료원장의 의사결정 유형, 공공 기업가정신 및 경영성과)

  • Lee, Jung-Woo;Kim, No-Sa
    • The Korean Journal of Health Service Management
    • /
    • v.12 no.1
    • /
    • pp.1-11
    • /
    • 2018
  • Objectives : The purpose of this study was to identify the relationship between decision-making types, public entrepreneurship, and performance management of local public hospital directors. Methods : A questionnaire survey was carried out to assess the dependent variables of directors' decision-making types and public entrepreneurship. The analysis of management performance was carried out through a comparison between 2016 results of, data of variation rate on medical revenue and change rate on medical profit and results in 2015. Results : Results indicated that local public hospital directors who used rational decision-making showed better performance management. The analysis showed that enterprise had a greater positive effect (+) on variation rate of medical revenue than that of innovation. However, innovation had a higher positive effect (+) on change rate of medical profit than that of enterprise. These results suggest that innovation and enterprise have a major influence on performance management. Conclusions : The survey used for this study suggests that an education and training program is needed to improve public hospital directors' ability for rational decision-making, public entrepreneurship and performance management. Additionally, the policy change guaranteeing autonomy within the proper range is demanded that Local Public Hospital Director having spirit of innovation and enterprise achieves peak capacity and have responsibility for management.

Estimation of PTC (Powertrain Cooling) Performance with Heat Rejection Rate (열방출량 (Heat Rejection Rate)을 이용한 PTC (Powertrain Cooling) 성능 추정)

  • Min, Sunki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3030-3034
    • /
    • 2015
  • It is important to consider powertrain cooling performance, when engine is applied to new vehicle. If the performance is poor, engine will be damaged by overheating. But, the development timing of engine is faster than timing of vehicle, it is difficult to test the cooling performance of new engine and vehicle. In this study the powertain cooling performance was estimated with some test and calculation data. First, the heat rejection test was conducted. From this test, the heat rejection data at required rpm and load was acquired. Second, coolant flow test was conducted. From this test coolant flow rate to radiator was measured. Then engine torque and rpm was calculated from vehicle load and speed. Vehicle load and speed was calculated from test mode. Then by comparing these data, the powertrain cooling performance was estimated.

Performance Improvement of Backpropagation Algorithm by Automatic Tuning of Learning Rate using Fuzzy Logic System

  • Jung, Kyung-Kwon;Lim, Joong-Kyu;Chung, Sung-Boo;Eom, Ki-Hwan
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.3
    • /
    • pp.157-162
    • /
    • 2003
  • We propose a learning method for improving the performance of the backpropagation algorithm. The proposed method is using a fuzzy logic system for automatic tuning of the learning rate of each weight. Instead of choosing a fixed learning rate, the fuzzy logic system is used to dynamically adjust the learning rate. The inputs of fuzzy logic system are delta and delta bar, and the output of fuzzy logic system is the learning rate. In order to verify the effectiveness of the proposed method, we performed simulations on the XOR problem, character classification, and function approximation. The results show that the proposed method considerably improves the performance compared to the general backpropagation, the backpropagation with momentum, and the Jacobs'delta-bar-delta algorithm.