• Title/Summary/Keyword: Performance Measurement

Search Result 6,989, Processing Time 0.04 seconds

Repeated Records Animal Model to Estimate Genetic Parameters of Ultrasound Measurement Traits in Hanwoo Cows (반복모형을 이용한 한우 초음파 측정형질의 유전모수추정)

  • Park, Cheol-Hyeon;Koo, Yang-Mo;Kim, Byung-Woo;Sun, Du-Won;Kim, Jung-Il;Song, Chi-Eun;Lee, Ki-Hwan;Lee, Jae-Youn;Jeoung, Yeoung-Ho;Lee, Jung-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.54 no.2
    • /
    • pp.71-75
    • /
    • 2012
  • The present study data were obtained from 36,894 cows in Korea Animal Improvement Association from 2001 to 2009 which was subjected for ultrasound measurements (eye muscle area, back-fat thickness, marbling score) and descent. Repeated record models were carried out using 7,913 of 36,894 of total animal traits. The ultrasound measured traits and performance test data were used to study the chest girth, body condition score, eye muscle area, back-fat thickness and marbling score with genetic correlation and parameters for the ultrasound measured traits using REMLF90 program. Genetic correlation of eye muscle area with back-fat thickness, marbling score and back-fat thickness with marbling score were noticed in repeated records animal model as 0.69, 0.54, and 0.59, whereas in multiple trait animal model method were 0.07, 0.66, and 0.39, respectively. Repeated records of animal models were used as positive correlation of traits. Multiple trait animal models were used as negative correlation of eye muscle area with marbling score. The analysis on repeat records of animal models using ultrasound measurements about Korean cattle showed positive effects for each traits. In comparison differences between the repeat records of animal models and multiple trait animal models was found with higher traits of her, the heritability and repeatability was found higher in repeat records animal models. In light of these assessments, carcass traits by ultrasound measurements are expected to help and improve an accurate analysis of each trait and if the research analysis using repeat records of animal models continue when we estimate genetic ability of these traits.

A Comparative Study on the Effective Deep Learning for Fingerprint Recognition with Scar and Wrinkle (상처와 주름이 있는 지문 판별에 효율적인 심층 학습 비교연구)

  • Kim, JunSeob;Rim, BeanBonyka;Sung, Nak-Jun;Hong, Min
    • Journal of Internet Computing and Services
    • /
    • v.21 no.4
    • /
    • pp.17-23
    • /
    • 2020
  • Biometric information indicating measurement items related to human characteristics has attracted great attention as security technology with high reliability since there is no fear of theft or loss. Among these biometric information, fingerprints are mainly used in fields such as identity verification and identification. If there is a problem such as a wound, wrinkle, or moisture that is difficult to authenticate to the fingerprint image when identifying the identity, the fingerprint expert can identify the problem with the fingerprint directly through the preprocessing step, and apply the image processing algorithm appropriate to the problem. Solve the problem. In this case, by implementing artificial intelligence software that distinguishes fingerprint images with cuts and wrinkles on the fingerprint, it is easy to check whether there are cuts or wrinkles, and by selecting an appropriate algorithm, the fingerprint image can be easily improved. In this study, we developed a total of 17,080 fingerprint databases by acquiring all finger prints of 1,010 students from the Royal University of Cambodia, 600 Sokoto open data sets, and 98 Korean students. In order to determine if there are any injuries or wrinkles in the built database, criteria were established, and the data were validated by experts. The training and test datasets consisted of Cambodian data and Sokoto data, and the ratio was set to 8: 2. The data of 98 Korean students were set up as a validation data set. Using the constructed data set, five CNN-based architectures such as Classic CNN, AlexNet, VGG-16, Resnet50, and Yolo v3 were implemented. A study was conducted to find the model that performed best on the readings. Among the five architectures, ResNet50 showed the best performance with 81.51%.

Improvement of analytical methods for arsenic in soil using ICP-AES (ICP-AES를 이용한 토양 시료 중 비소 분석 방법 개선)

  • Lee, Hong-gil;Kim, Ji In;Kim, Rog-young;Ko, Hyungwook;Kim, Tae Seung;Yoon, Jeong Ki
    • Analytical Science and Technology
    • /
    • v.28 no.6
    • /
    • pp.409-416
    • /
    • 2015
  • ICP-AES has been used in many laboratories due to the advantages of wide calibration range and multi-element analysis, but it may give erroneous results and suffer from spectral interference due to the large number of emission lines associated with each element. In this study, certified reference materials (CRMs) and field samples were analyzed by ICP-AES and HG-AAS according to the official Korean testing method for soil pollution to investigate analytical problems. The applicability of HG-ICP-AES was also tested as an alternative method. HG-AAS showed good accuracies (90.8~106.3%) in all CRMs, while ICP-AES deviated from the desired range in CRMs with low arsenic and high Fe/Al. The accuracy in CRM030 was estimated as below 39% at the wavelength of 193.696 nm by ICP-AES. Significant partial overlaps and sloping background interferences were observed near to 193.696 nm with the presence of 50 mg/L Fe and Al. Most CRMs were quantified with few or no interferences of Fe and Al at 188.980 nm. ICP-AES properly assessed low and high level arsenic for field samples, at 188.980 nm and 193.696 nm, respectively. The importance of the choice of measurement wavelengths corresponding to relative arsenic level should be noted. Because interferences were affected by the sample matrix, operation conditions and instrument figures, the analysts were required to consider spectral interferences and compare the analytical performance of the recommended wavelengths. HG-ICP-AES was evaluated as a suitable alternative method for ICP-AES due to improvement of the detection limit, wide calibration ranges, and reduced spectral interferences by HG.

A Study on a Effect of Product Design and a Primary factor of Qualify Competitiveness (제품 디자인의 파급효과와 품질경쟁력의 결정요인에 관한 연구)

  • Lim, Chae-Suk;Yoon, Jong-Young
    • Archives of design research
    • /
    • v.18 no.4 s.62
    • /
    • pp.95-104
    • /
    • 2005
  • The purpose of this study is to estimate the determinants of product design and analyze the impacts of product design on quality competitiveness, product reliability, and consumer satisfaction in an attempt to provide a foundation for the theory of design management. For this empirical analysis, this study has derived the relevant measurement variables from a survey on 400 Korean manufacturing firms during the period of $August{\sim}October$ 2003. The empirical findings are summarized as follows: First, the determinants of product design are very significantly (at p<0.001) estimated to be the R&D capability, the level of R&D expenditure, the level of innovative activities(5S, TQM, 6Sigma, QC, etc.). This empirical result can support Pawar and Driva(1999)'s two principles by which the performance of product design and product development can be simultaneously evaluated in the context of CE(concurrent engineering) of NPD(newly product development) activities. Second, the hypothesis on the causality: product design${\rightarrow}$quality competitiveness${\rightarrow}$customer satisfaction${\rightarrow}$customer loyalty is very significantly (at p<0.001) accepted. This implies that product design positively affects consumer satisfaction, not directly but indirectly, by influencing quality competitiveness. This empirical result of this study can also support the studies of for example Flynn et al.(1994), Ahire et at.(1996), Afire and Dreyfus(2000) which conclude that design management is a significant determinant of product quality. The aforementioned empirical results are important in the following sense: the empirical result that quality competitiveness plays a bridging role between product design and consumer satisfaction can reconcile the traditional debate between QFD(quality function development) approach asserted by product developers and conjoint analysis maintained by marketers. The first empirical result is related to QFD approach whereas the second empirical result is related to conjoint analysis. At the same time, the empirical results of this study can support the rationale of design integration(DI) of Ettlie(1997), i.e., the coordination of the timing and substance of product development activities performed by the various disciplines and organizational functions of a product's life cycle. Finally, the policy implication (at the corporate level) from the empirical results is that successful design management(DM) requires not only the support of top management but also the removal of communication barriers, (i.e. the adoption of cross-functional teams) so that concurrent engineering(CE), the simultaneous development of product and process designs can assure product development speed, design quality, and market success.

  • PDF

Dosimetric Characterization of an Ion Chamber Matrix for Intensity Modulated Radiation Therapy Quality Assurance (세기변조방사선치료 선량분포 확인을 위한 2차원적 이온전리함 배열의 특성분석)

  • Lee, Jeong-Woo;Hong, Se-Mie;Kim, Yon-Lae;Choi, Kyoung-Sik;Jung, Jin-Beom;Lee, Doo-Hyun;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.131-135
    • /
    • 2006
  • A commercial ion chamber matrix was examined the characteristics and its performance for radiotherapy qualify assurance. The device was the I'mRT 2D-MatriXX (Scanditronix-Wellhofer, Schwarzenbruck, Germany). The 2D-MatriXX device consists of a 1020 vented ion chamber array, arranged in $24{\times}24cm^2$ matrix. Each ion chamber has a volume of $0.08cm^3$, spacing of 0.762 cm and minimum sampling time of 20 ms. For the investigation of the characteristics, dose linearity, output factor, short-term reproducibility and dose rate dependency were tested. In the testing of dose linearity. It has shown a good signal linearity within 1% in the range of $1{\sim}800$cGy. Dose rate dependency was found to be lower than 0.4% (Range: 100-600 Mu/min) relative to a dose rate of 300 Mu/min as a reference. Output factors matched very well within 0.5% compared with commissioned beam data using a ionization chamber (CC01, Scanditronix-Wellhofer, Schwarzenbruck, Germany) in the range of field sizes $3{\times}3{\sim}24{\times}24cm^2$. Short-term reproducibility (6 times with a interval of 15 minute) was also shown a good agreement within 0.5%, when the temperature and the pressure were corrected by each time of measurement. in addition, we compared enhanced dynamic wedge (EDW, Varian, Palo Alto, USA) profiles from calculated values in the radiation planning system with those from measurements of the MatriXX. Furthermore, anon-uniform IMRT dose fluence was tested. All the comparison studies have shown good agreements. In this study, the MatriXX was evaluated as a reliable dosimeter, and it could be used as a simplistic and convenient tool for radiotherapy qualify assurance.

  • PDF

Critical Analyses of '2nd Science Inquiry Experiment Contest' (과학탐구 실험대회의 문제점 분석)

  • Paik, Seoung-Hey
    • Journal of The Korean Association For Science Education
    • /
    • v.15 no.2
    • /
    • pp.173-184
    • /
    • 1995
  • The purpose of this study was to analyse the problems of 'Science Inquiry Experiment Contest(SIEC)' which was one of 8 programs of 'The 2nd Student Science Inquiry Olympic Meet(SSIOM)'. The results and conclusions of this study were as follows: 1. It needs to reconsider the role of practical work within science experiment because practical work skills form one of the mainstays in current science. But the assessment of students' laboratory skills in the contest was made little account of. It is necessary to remind of what it means to be 'good at science'. There are two aspects: knowing and doing. Both are important and, in certain respects, quite distinct. Doing science is more of a craft activity, relying more on craft skill and tacit knowledge than on the conscious application of explicit knowledge. Doing science is also divided into two aspects, 'process' and 'skill' by many science educators. 2. The report's and checklist's assessment items were overlapped. Therefore it was suggested that the checklist assessment items were set limit to the students' acts which can't be found in reports. It is important to identify those activities which produce a permanent assessable product, and those which do not. Skills connected with recording and reporting are likely to produce permanent evidence which can be evaluated after the experiment. Those connected with manipulative skills involving processes are more ephemeral and need to be assessed as they occur. The division of student's experimental skills will contribute to the accurate assess of student's scientific inquiry experimental ability. 3. There was a wide difference among the scores of one participant recorded by three evaluators. This means that there was no concrete discussion among the evaluators before the contest. Despite the items of the checklists were set by preparers of the contest experiments, the concrete discussions before the contest were necessary because students' experimental acts were very diverse. There is a variety of scientific skills. So it is necessary to assess the performance of individual students in a range of skills. But the most of the difficulties in the assessment of skills arise from the interaction between measurement and the use. To overcome the difficulties, not only must the mark needed for each skill be recorded, something which all examination groups obviously need, but also a description of the work that the student did when the skill was assessed must also be given, and not all groups need this. Fuller details must also be available for the purposes of moderation. This is a requirement for all students that there must be provision for samples of any end-product or other tangible form of evidence of candidates' work to be submitted for inspection. This is rather important if one is to be as fair as possible to students because, not only can this work be made available to moderators if necessary, but also it can be used to help in arriving at common standards among several evaluators, and in ensuring consistent standards from one evaluator over the assessment period. This need arises because there are problems associated with assessing different students on the same skill in different activities. 4. Most of the students' reports were assessed intuitively by the evaluators despite the assessment items were established concretely by preparers of the experiment. This result means that the evaluators were new to grasp the essence of the established assessment items of the experiment report and that the students' assessment scores were short of objectivity. Lastly, there are suggestions from the results and the conclusions. The students' experimental acts which were difficult to observe because they occur in a flash and which can be easily imitated should be excluded from the assessment items. Evaluators are likely to miss the time to observe the acts, and the students who are assessed later have more opportunity to practise the skill which is being assessed. It is necessary to be aware of these problems and try to reduce their influence or remove them. The skills and processes analysis has made a very useful checklist for scientific inquiry experiment assessment. But in itself it is of little value. It must be seen alongside the other vital attributes needed in the making of a good scientist, the affective aspects of commitment and confidence, the personal insights which come both through formal and informal learning, and the tacit knowledge that comes through experience, both structured and acquired in play. These four aspects must be continually interacting, in a flexible and individualistic way, throughout the scientific education of students. An increasing ability to be good at science, to be good at doing investigational practical work, will be gained through continually, successively, but often unpredictably, developing more experience, developing more insights, developing more skills, and producing more confidence and commitment.

  • PDF

Factors Affecting Wet-Paddy Threshing Performance (탈곡기의 제작동요인이 벼의생탈곡성능에 미치는 영향)

  • 남상일;정창주;류관희
    • Journal of Biosystems Engineering
    • /
    • v.5 no.1
    • /
    • pp.1-14
    • /
    • 1980
  • Threshing operation may be one of the most important processes in the paddy post-production system as far as the grain loss and labor requirement are concerned . head-feeding type threshers commercially available now in Korea originally were developed for threshing dry paddy in the range of 15 to 17 % in wet basis. However, threshing wet-paddy with the grain moisture content above 20 % has been strongly recommended, especially for new high-yielding Indica -type varieties ; (1) to reduce high grain loss incurred due to the handling operations, and (2) to prevent the quantitative and qualitative loss of milled -rice when unthreshed grains are rewetted due to the rainfall. The objective of this study were to investigate the adaptability of both a head-feeding type thresher and a throw-in type thresher to wet-paddy , and to find out the possiblilities of improving the components of these threshers threshing. Four varieties, Suweon 264 and Milyang 24 as Tongil sister line varieties, minehikari and Jinhueng as Japonica-type varieties, were used at the different levels of the moisture content of grains. Both the feed rate and the cylinder speed were varied for each material and each machine. The thresher output quality , composition of tailing return, and separating loss were analyzed from the sampels taken at each treatment. A separate experiment for measurement opf the power requirement of the head-feeding type thresher was also performed. The results are summarized as follows : 1. There was a difference in the thresher output quality between rice varieties. In case of wet-paddy threshing at 550 rpm , grains with branchlet and torn heads for the Suweon 264 were 12 % and 7 % of the total output in weight, respectively, and for the Minehikari 4.5 % and 2 % respectively. In case of dry paddy threshing , those for the Suweon 264 were 8 % and 5% , and for the Minehikari 4% and 1% respectively. However, those for the Milyang 23 , which is highly susceptable to shattering, were much lower with 1 % and 0.5% respectively, regardless of the moisture content of the paddy. Therefore, it is desirable to breed rice varieties of the same physical properties as well as to improve a thresher adaptable to all the varieties. Torn heads, which increased with the moisture content of rall the varieties except the Milyang 23 , decreased as the cylinder speed increased, but grains with branchlet didnt decrease. The damaged kernels increased with the cylinder speed. 3. The thresher output quality was not affected much by the feed rate. But grains with branchlet and torn heads increased slightly with the feed rate for the head-feeding type thresher since higher resistance lowered at the cylinder speed. 4. In order to reduce grains with branchlet and torn heads in wet-paddy threshing , it is desirable to improve the head-feeding type thresher by developing a new type of cylinder which to not give excess impact on kernels or a concave which has differenct sizes of holes at different locations along the cylinder. 5. For the head-feeding type thresher, there was a difference in separating loss between the varieties. At the cylinder speed of 600 rpm the separating losses for the Minehikari and the Suweon 264 were 1.2% and 0.6% respectively. The separating loss of the head-feeding type thresher was not affected by the moisture content of paddy while that of the Mini-aged thresher increased with the moisture content. 6. From the analysis of the tailings return , to appeared that the tailings return mechanism didn't function properly because lots of single grains and rubbishes were unnecessarily returned. 7. Adding a vibrating sieve to the head-feeding type thresher could increase the efficiency of separation. Consequently , the tailing return mechanism would function properly since unnecessary return could be educed greatly. 8. The power required for the head-feeding type thresher was not affected by the moisture content of paddy, but the average power increased linearly with the feed rate. The power also increased with the cylinder speed.

  • PDF

Carbon Monoxide Dispersion in an Urban Area Simulated by a CFD Model Coupled to the WRF-Chem Model (WRF-Chem 모델과 결합된 CFD 모델을 활용한 도시 지역의 일산화탄소 확산 연구)

  • Kwon, A-Rum;Park, Soo-Jin;Kang, Geon;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.5_1
    • /
    • pp.679-692
    • /
    • 2020
  • We coupled a CFD model to the WRF-Chem model (WRF-CFD model) and investigated the characteristics of flows and carbon monoxide (CO) distributions in a building-congested district. We validated the simulated results against the measured wind speeds, wind directions, and CO concentrations. The WRF-Chem model simulated the winds from southwesterly to southeasterly, overestimating the measured wind speeds. The statistical validation showed that the WRF-CFD model simulated the measured wind speeds more realistically than the WRF-Chem model. The WRF-Chem model significantly underestimated the measured CO concentrations, and the WRF-CFD model improved the CO concentration prediction. Based on the statistical validation results, the WRF-CFD model improved the performance in predicting the CO concentrations by taking complicatedly distributed buildings and mobiles sources of CO into account. At 04 KST on May 22, there was a downdraft around the AQMS, and airflow with a relatively low CO concentration was advected from the upper layer. Resultantly, the CO concentration was lower at the AQMS than the surrounding area. At 15 KST on May 22, there was an updraft around the AQMS. This resulted in a slightly higher CO concentration than the surroundings. The WRF-CFD model transported CO emitted from the mobile sources to the AQMS measurement altitude, well reproducing the measured CO concentration. At 18 KST on May 22, the WRF-CFD model simulated high CO concentrations because of high CO emission, broad updraft area, and an increase in turbulent diffusion cause by wind-shear increase near the ground.

Extra Dose Measurement of Differential Slice Thickness of MVCT Image with Helical Tomotherapy (토모테라피 치료 시 MVCT Image의 Slice Thickness 차이에 따른 선량 비교)

  • Lee, Byungkoo;Kang, Suman
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.2
    • /
    • pp.145-149
    • /
    • 2013
  • Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF