• 제목/요약/키워드: Performance Evaluation of Facility

검색결과 337건 처리시간 0.025초

Evaluation of urban pollutant washoff characteristics and treatment efficiency of a small constructed wetland

  • Reyes, Nash Jett DG.;Geronimo, Franz Kevin F.;Kim, Lee-Hyung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2019년도 학술발표회
    • /
    • pp.412-412
    • /
    • 2019
  • Nature-based solutions (NBS) offer a wide variety of techniques that promote cost-efficient stormwater management practices. In particular, low impact development facilities utilize NBS principles to restore the ecosystem services in a highly-urbanized area. Despite the advancements in these technologies, several considerations should still be addressed to ensure optimum functionality and attainment of desired pollutant removal efficiency a LID facility. This study evaluated the mass flushing characteristics of pollutants in an urban catchment and the efficiency of a small constructed wetland (SCW) in treating urban stormwater runoff. 21 rainfall events from 2010 to 2018 were monitored to determine and quantify stormwater pollutants. The highest pollutant washoff was observed on rainfall depths ranging from 0.1mm to 10mm, whereas events with greater rainfall depths exhibited lower pollutant concentrations due to dilution effect. However, the SCW manifested lower pollutant-removal performance on rainfall depths exceeding 10mm due to the exceedance of the facility's design rainfall. This study is beneficial in assessing the dynamics of pollutant washoff and efficiency of LID facilities subjected under various external factors.

  • PDF

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

′학교도서관′ 학교의 중심으로 육성 (Rebuilding the School Library as Center in the School)

  • 홍강표
    • 한국비블리아학회지
    • /
    • 제14권2호
    • /
    • pp.5-12
    • /
    • 2003
  • 지식기반사회에 적합한 창의적$\cdot$자율적 인재양성을 위해 학생들의 책 읽기 습관 함양과 탐구 중심의 수업방법 개선이 필요하게 되었으며, 제7차 교육과정의 시행에 따라 수행평가, 재량활동$\cdot$특별활동 등을 지원하기 위한 기본시설로서 학교도서관의 중요성이 부각되었다. 이에 따라 '학교도서관 활성화 종합방안'을 수립하게 되었는데 그 주요내용은 열악한 학교도서관 환경을 개선하기 위한 시설, 장서, 재정, 인력운영 계획과 함께 학교도서관이 교수-학습활동을 실질적으로 지원할 수 있도록 도서관 활용 수업 방안까지 포괄됨으로써 학교도서관이 명실상부하게 학교의 중심부로 자리잡도록 하는 데 주안점을 두고 있다.

  • PDF

지역문화축제의 서비스품질에 대한 중요도-성취도 분석(2013 평창효석문화제를 중심으로) (The Importance-Performance Analysis on the Service Quality of Local Cultural Festivals(Based on Pyeongchang Hyoseok Culture Festival in 2013))

  • 이제용
    • 한국콘텐츠학회논문지
    • /
    • 제14권5호
    • /
    • pp.411-424
    • /
    • 2014
  • 본 연구의 목적은 서비스품질을 활용한 측정기준을 설정하여 지역문화축제에 대한 인식수준을 파악함과 동시에 서비스품질에 대한 중요도-성취도 분석을 통하여 향후 서비스품질 향상 및 방문객의 축제이용시 이용극대화를 위한 효율적인 개선운영방안을 모색하여 지역문화축제의 질적향상에 도움이 되고자 한다. 중요도와 성취도간 대응일치 t-test 결과 1)응답성 요인에서는 휴식공간여부, 시설배치도, 의사전달, 화장실비치/청결도 2) 확신성 요인에서는 음식가격, 종업원의 친절, 3)신뢰성 요인에서는 (행사장까지)축제팸플릿, 안내시설/표지판, 친절도, 스케줄안내, 신속한 대응 등 모든 항목, 4) 유형성 요인에서도 지역문화인지도, 유익성, 스토리텔링 등 모든 항목에서 5) 공감성 요인에서는 행사의 다양성과 축제내용 항목에서 유의한 차이가 있는 것으로 나타났다.

Performance and Reliability Characteristics of the Free Piston Free Displacer Stirling Cryocooler

  • Park, Seong-Je;Hong, Yong-Ju;Kim, Hyo-Bong;Koh, Deuk-Yong;Kim, Yang-Hoon
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.46-51
    • /
    • 2004
  • This paper presents the results of a series of performance and reliability tests for the Stirling cryocooler. Infrared sensor systems incorporating cryocoolers are required to be qualified to the appropriate specification for the performance and reliability. FPFD Stirling cryocooler is currently under development for cooling infrared detector. Manufactured Stirling cryocooler delivers approximately 0.9W cooling at 80K for 30W∼40W of input power. It takes approximately 2 minutes to cool down to 80K at the ambient temperature of 23$^{\circ}C$. Performance characteristics for the vibration, acoustic noise, EMI and leak rate of the Stirling cryocooler are evaluated. We performed low and high temperature keeping test from -32$^{\circ}C$ to +52$^{\circ}C$ and operating test at high and low temperature cyclic range with acceptance tests performed at scheduled intervals. Cooling capacity is determined as a function of the temperatures at the compressor, hot end and cold tip at the expander. Finally, we describe the experimental facility for the MTTF evaluation and some typical results of the Stirling cryocooler.

An Enhanced Investment Priority Decision of Facilities Considering Reliability of Distribution Networks

  • Choi Jung-Hwan;Park Chang-Ho;Kim Kwang-Ho;Jang Sung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권3호
    • /
    • pp.260-268
    • /
    • 2005
  • This paper proposes an improved investment pnonty decision method of facilities considering the reliability of distribution networks. The proposed method decides an investment order of the facilities combining, by fuzzy rules, the investment priority decision by KEPCO and that by reliability evaluation indices. The reliability evaluation indices are SAIFI (System Average Interruption Frequency Index) and SAIDI (System Average Interruption Duration Index). The reliability analysis method of distribution networks applied in this paper utilizes the analytic method, where the used reliability data is the historical data of KEPCO. Particularly, we assumed that the failure rate increases as the equipment ages. To verify the performance of the proposed method, we applied it with the planned projects to reinforce the weak electrical facilities in KEPCO in 2004. The evaluation result showed that, under a limited budget, the reliability of KEPCO in the Busan region using the proposed method could be enhanced if used rather than the conventional method typically in place. Therefore, the results verify that the proposed method can be efficiently used in the actual priorities method for investing in the electrical facilities.

미생물 활성물질이 내재된 담체를 이용한 생물반응조의 성능 평가 (Performance Evaluation of a Bioreactor Partially Packed with Porous Media Containing a MA (Microorganism Activator))

  • 박종훈;홍석원;최용수;이상협;김승준;강선홍
    • 상하수도학회지
    • /
    • 제21권1호
    • /
    • pp.47-55
    • /
    • 2007
  • The waste water treatment facility at rural and mountainous region in catchment areas of dams should be small scale. The wastewater treatment facility of small scale has some specification as follows;1)simple process, 2)low maintenance cost, and 3)high removal efficiency. So, we developed the bioreactor which can be satisfied with the specification of small scale waste water treatment facility. The bioreactor consisted of the anoxic and oxic zone. The two zones were effectively separated by cone type baffle. By the effective separation through CTB, the nitrification and denitrification reaction occurred effectively. Therefore, the removal efficiency of total nitorgen (TN) increased compared to other types of baffle. And, we put into the bio activated media in oxic zone to increase the concentration and activity of microbiology. The media contained the components which were made of many kinds of the minerals to increase the activity of microbiology. Additionally, we observed that the phosphate removal efficiency increased by bio activated media. This is resulted from the coagulation-sedimentation reaction by mineral in components. The average removal efficiencies of TN and TP during Run 2 were 69 and 89% which were 4 and 25% higher than those during Run 1 without the MA, respectively. For BOD, COD, SS and TKN, the average removal efficiencies at Run 2 were slightly higher than those at Run 1. Therefore, we could maintain the high concentration and high activity of microbiology through bioreactor developed in this study. And the removal efficiency of TN and TP increased.

플라즈마 버너를 적용한 요소수에서 암모니아로의 고속 전환 기술 성능 평가 (Performance Evaluation for Fast Conversion from Urea to an Ammonia Conversion Technology with a Plasma Burner)

  • 조성권;김관태;이대훈;송영훈
    • 한국대기환경학회지
    • /
    • 제32권5호
    • /
    • pp.526-535
    • /
    • 2016
  • Recently, fine dust in atmosphere have been considerably issued as a harmful element for human. Nitrogen oxide ($NO_x$) exhausted from diesel engines and power plants has been disclosed as a main source of secondary production of fine dust. In order to prevent exhausting these nitrogenous compounds into atmosphere, a treatment system with selective catalytic reduction (SCR) catalyst with ammonia as a reductant has been used in various industries. Urea solution has been widely studied to supply ammonia into a SCR catalytic reactor, safely. However, the conversion of urea solution to ammonia has several challenges, especially on a slow conversion velocity. In the present study, a fast urea conversion system including a plasma burner was suggested and designed to evaluate the performances of urea conversion and initial operation time. A designed lab-scale facility has a plasma burner, urea nozzle, mixer, and SCR catalyst which is for hydrolysis of isocyane. Flow rate of methane that is a fuel of the plasma burner was varied to control temperatures in the urea conversion facility. From experimental results, it is found that urea can be converted into ammonia using high temperature condition of above $400^{\circ}C$. In the designed test facility, it is found that ammonia can be produced within 1 min from urea injection and the result shows prospect commercialization of proposed technology in the SCR facilities.

빅데이터 분석을 통한 중력식 항만시설 수정프로젝트 레벨의 상태변화 특성 분석 (A Study on Condition Analysis of Revised Project Level of Gravity Port facility using Big Data)

  • 나용현;박미연;장신우
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.254-265
    • /
    • 2021
  • 연구목적: 국내 항만시설의 진단을 통한 성능 및 안전에 대한 점검과 진단을 20년 넘게 진행되었지만 그 진단 이력과 결과를 활용한 중장기적인 시설개선과 성능개선을 위한 발전전략이나 방향이 현실적으로 작동하지 않고 있다. 특히, 사용년수가 오래된 항만구조물의 경우, 선박의 대형화와 사용빈도 증가, 기후변화로 인한 자연재해의 영향 등으로 안전성능과 기능적 면에서 상당히 많은 문제점을 내포하고 있다. 연구방법: 본 연구에서는 중력식 안벽에 대한 부재수준의 유지관리 이력 데이터를 수집하여 이를 빅데이터로써 정의하고 해당 데이터를 바탕으로 프로젝트 수준의 시설물의 노후화 패턴 및 열화를 추정하기 위한 예측근사모델을 도출하였다. 특히 GP 및 SGP 기법의 머신러닝 알고리즘을 통하여 생성된 상태기반 노후도 패턴 및 열화 근사모델에 대한 유효성 검토를 통해 빅데이터 활용에 적합한 모델을 상호비교하고 제안하였다. 연구결과: 제안된 기법의 적합성을 검토한 결과 GP기법은 RMSE 및 R2는 0.9854와 0.0721, SGP기법은 0.7246과 0.2518로 GP기법을 적용한 예측모델이 적합한 것으로 검토 되었다. 결론: 머신러닝 기법을 통해 이러한 연구는 향후 항만시설 데이터취합이 지속적으로 이루어진다면 향후 항만시설 투자의사결정에 중요한 역할을 할 것으로 기대한다.

어린이 급식소의 위생관리 실태 조사 및 방문지도에 따른 위생관리 개선 효과 분석 (The Assessment of Food Safety Practices and the Effect of Visiting Education on Food Safety Improvement in Children's Foodservice Facilities)

  • 백재은;이현아;배현주
    • 한국식품조리과학회지
    • /
    • 제31권6호
    • /
    • pp.764-772
    • /
    • 2015
  • 본 연구는 어린이 급식소의 위생 안전관리 실태를 조사하고, 경기 남부지역 소재 총 102개소의 어린이 급식소를 대상으로 1년 동안 순회방문지도를 실시한 결과 위생 안전관리 수준이 어느 정도 개선되었는지를 평가하고자 수행하였다. 평가 대상 급식소는 어린이집이 84.3%, 유치원과 지역아동센터가 각각 7.8%였다. 그리고 운영주체는 민간이 70.6%, 국공립이 19.6%, 법인이 9.8%였다. 급식 원아수는 50명 미만이 46.1%, 50명 이상 100명 미만인 곳이 53.9%였다. 위생 안전관리 실태 평가 결과 총점은 평균 84.09점이었고, 위생 안전관리 평가 총점은 급식소 구분에 따라서는 어린이집과 유치원에 비해 지역아동센터의 평가 점수가 유의적으로 낮았다(p<0.01). 또한 급식소 운영주체에 따라서는 국공립으로 운영하는 곳이 민간에서 운영하는 곳에 비해 위생 안전관리 점수가 유의적으로 높았다(p<0.001). 그리고, 급식 원아수가 50명 이상인 경우가 50명 미만인 경우에 비해 위생 안전관리 총점이 유의적으로 높았다(p<0.01). 한편, 위생 안전관리 수행도가 90% 이상 되는 항목은 전체의 41.0%, 수행도가 60%미만인 항목은 전체의 15.4%였다. 이 중 수행도가 가장 낮은 항목은 '채소와 과일의 세척 소독 실시'(26.5%)였다. 또한 순회방문지도 평가 회차에 따른 위생 안전관리 평가 총점의 차이 분석을 실시한 결과 1, 2회차 때에는 유의적인 차이를 보이지 않다가 3회차에서는 1, 2회차에 비해 평가 점수가 유의적으로 상승하였다. 그리고 이원분산분석을 실시한 결과, 전체 위생 안전관리 총점은 급식소 구 분(F=21.730, p<0.001)과 순회방문지도 회차(F=7.968, p<0.001)에 따라서 유의적인 차이가 있었고, 급식소 운영주체(F=31.387, p<0.001)와 순회방문지도 회차(F=7.507, p<0.001)에 따라서 유의적인 차이가 있었다. 또한 급식 원아수(F=17.133, p<0.001)와 순회방문지도 회차(F=17.065, p<0.001)에 따라서도 유의적인 차이가 있었다. 이 결과를 종합해볼 때 어린이 급식관리지원센터의 순회방문지도는 어린이 급식소의 위생 안전관리 수행도를 효과적으로 향상시키는데 기여했다고 판단된다.