3kW급 계통연계형 태양광발전시스템의 성능특성 비교분석에 관한 연구 (A Study on Performance Analysis of 3kW Grid-Connected PV Systems)

  • 소정훈;최주엽;유권종;정영석;최재호
    • 한국태양에너지학회 논문집
    • /
    • 제24권2호
    • /
    • pp.9-15
    • /
    • 2004
  • 3kW grid connected PV(photovoltaic) systems have been constructed for evaluating and analyzing performance of PV system at FDTC(field demonstration test center) in Korea, PV systems installed in FDTC have been operating and monitored since November 2002. As climatic and irradiation conditions have been varied through long-term field test, data acquisition system has been constructed for measuring performance of PV system to observe the overall effect of environmental conditions on their operation characteristics. The performance of PV systems has been evaluated and analyzed for component perspective(PV array and power conditioning system) and global perspective(system efficiency, capacity factor, and electrical power energy) by field test. By the results, it is very important to develop optimal design technology of grid connected PV system.

폐플라스틱의 열분해 유화기술 개발 (Process Development of Pyrolysis Liquefaction for Waste Plastics)

  • 노남선;신대현;박소원;이경환;김광호;전상구;조봉규
    • 신재생에너지
    • /
    • 제2권2호
    • /
    • pp.118-125
    • /
    • 2006
  • The target of this work was the process development of demonstration plant to produce the high quality alternative fuel oil by the pyrolysis of mixed plastic waste. In the first step of research, the bench-scale units of 70 t/y and the pilot plant of 360 t/y had been developed. Main research contents in this step were the process performance test of pilot plant of 360 ton/year and the development of demonstration plant of 3,000 t/y, which was constructed at Korea R & D Company in Kimjae City. The process performance of pilot plant of 360 t/y showed about 80% yield of liquid product, which was obtained by both light gas oil(LGO) and heavy gas oil(HGO), The boiling point range distribution of LO product that was mainly consisting of olefin components in PONA group appeared at between that of commercial gasoline and kerosene. On the other hand, HO product was mainly paraffin and olefin components and also appeared at upper temperature distribution range than commercial diesel. Gas product showed a high fraction of $C_3\;and\;C_4$ product like LPG composition, but also a high fraction of $CO_2$ and CO by probably a little leak of process.

  • PDF

폐플라스틱의 열분해 유화기술 개발 (Process Development of Pyrolysis Liquefaction for Waste Plastics)

  • 노남선;신대현;박소원;이경환;김광호;전상구;조봉규
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.523-526
    • /
    • 2006
  • The target of this work was the process development of demonstration plant to produce the high quailty alternative fuel oil by the pyrolysis of mixed plastic waste. In the first step of research, the bench-scale units of 70t/y and the pi lot plant of 360 t/v had been developed. Main research contents in this step were the process performance test of pilot plant ot 360ton/year and the development of demonstration plant of 3 000 t/y which was constructed at Korea R & D Company in Kimjae City. The process performance of pilot plant of 360 t/v showed components in PONA group appeared at between that of commercial gasoline and kerosene. On the other hand, HO product was mainly paraffin and olefin components and also appeared at upper temperature distribution range than commercial diesel. Gas product showed a high fraction of $C_3\;and\;C_4$ product like LPG composition, but also a high fraction of $CO_2$ and CO by probably a little leak of process.

  • PDF

입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성 (Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth)

  • 이재랑;;전성민;이강산;김광득;박영옥
    • 한국입자에어로졸학회지
    • /
    • 제12권4호
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

한국형 위성 발사체 성능 검증위성의 진동환경에 관한 연구 (A Study on the Vibrational Environment Test of KSLV-1 Demonstration Satellite)

  • 서현석;김홍배;우성현;채장수;오태식
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.966-970
    • /
    • 2005
  • On the basis of the development of KSLV-1, KoDSat was designed and manufactured to demonstrate the performance of KSLV-1. KoDSat is exposed to a severe vibrational environment at launch. The structural reliability of KoDSat has to be verified using vibrational test. The structural compatibility and verification of components between analysis and test can be proved using environmental vibration test. In this paper, we review the structural characteristic of thruster control unit for a space launch vehicle and design TCU housing using mathematical model. In order to verify the structural compatibility and reliability, half-sine shock, random and sing sweep vibration test was performed. Especially, sing sweep vibration test result is compared with analysis result and mathematical model is verified.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2005년도 춘계학술대회
    • /
    • pp.403-407
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a greenhouse culture facility for reducing heating cost, increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex in Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely investigated by changing the control condition based on the temperature difference which is the most important operating parameter. For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, it is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

태양열 시설원예 난방시스템 장기실증 성능분석 연구 (Study on the performance analysis of long-term field test for protected horticulture heating system using solar thermal energy)

  • 이상남;강용혁;유창균;김진수
    • 신재생에너지
    • /
    • 제1권2호
    • /
    • pp.53-59
    • /
    • 2005
  • Objective of the research is to demonstrate solar thermal space and ground heating system which is integrated to a green-house culture facility for reducing healing cost, Increasing the value of product by environment control, and developing advanced culture technology by deploying solar thermal system. Field test for the demonstration was carried out in horticulture complex In Jeju Island. Medium scale solar hot water system was installed in a ground heating culture facility. Reliability and economic aspect of the system which was operated complementary with thermal storage and solar hot water generation were analyzed by investigating collector efficiency, operation performance, and control features. Short term day test on element performance and Long term test of the whole system were carried out. Optimum operating condition and its characteristics were closely Investigated by changing the control condition based on the temperature difference which Is the most important operating parameter For establishing more reliable and optimal design data regarding system scale and operation condition, continuous operation and monitoring on the system need to be further carried out. However, It is expected that, in high-insolation areas where large-scale ground storage is adaptable, solar system demonstrated in the research could be economically competitive and promisingly disseminate over various application areas.

  • PDF

계통연계형 태양광 발전시스템의 운전특성에 관한 연구 (A Study on the Operating Characteristics for a Grid-Connected Photovoltaic Power System)

  • 안교상;황인호;정승주;임희천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 G
    • /
    • pp.2436-2438
    • /
    • 1998
  • The operating characteristics of a 3 kW grid-connected photovoltaic (PV) power system was studied by analying annual photovoltaic data. The system performance for grid connection was investigated using a DC/ AC inverter. The results of a demonstration test show that the system utilization rate is 15.6% and the system efficiency is 8.03%.

  • PDF

누출점검용 스마트가스미터의 성능시험 가이드라인 개발 연구 (Study on Development of Performance Evaluation Guidelines for Leak Test Smart Gas Meter)

  • 김민준;오정석
    • 한국가스학회지
    • /
    • 제23권5호
    • /
    • pp.8-14
    • /
    • 2019
  • 국내 도시가스 보급률은 크게 성장했지만, 국내 가스계량기 계량·안전점검·요금 분야는 아직 서비스 초기방식에서 벗어나지 못하고 있다. 스마트가스미터에 관한 개발과 연구가 활발히 이루어지고 있지만 스마트가스미터의 도입에는 신뢰성과 안전성을 검증할 수 있는 합리적인 성능평가 방안과 기준이 필요하다. 본 논문은 스마트가스미터의 성능을 시험하기 위한 성능시험 시작품을 제작하고 시작품의 실증 운용을 통해 성능평가 방안을 최적화하여 국내에 스마트가스미터가 원활하게 확대/보급될 수 있도록 하는 것을 목적으로 한다.

기계적 특성이 우수한 원통형 복합재료 안테나의 설계 및 충격 실험 (Design and Impact Testing of Cylindrical Composite-Antenna-Structures having High Mechanical Performanc)

  • 김동섭;조상현;황운봉;이중희
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2005년도 추계학술발표대회 논문집
    • /
    • pp.35-38
    • /
    • 2005
  • The Objective of this work was to design Composite Antenna Structures (CAS) and investigate impact behavior of CAS which was various curvature. This term, CAS, indicates that structural surface becomes antenna. Constituent materials were selected considering electrical properties, dielectric constants and tangent loss as well as mechanical properties. For the antenna performance, microstrip antenna layers inserted into structural layers were designed for satellite communication at the resonant frequency of 12.5 GHz and final demonstration article was. After making five kinds of curved CAS, which radii of curvature are flat, 200, 150, 100, 50 mm. The antenna performance changed in accordance with variation of curvature. The Reflection coefficient was independent of curvature but the gain decreased with the radius of curvature. The impact test equipment was Dyna-8250 drop weight tester. The impact characteristic in accordance with curvature is maximum absorb energy is same each other. The impact energy was 8.5 J. For various Impact energy test, five energy levels 3 J, 5 J, 7 J, 10 J, 20 J were used. The performance of impact damaged antenna was estimated by measuring the return loss and the radiation pattern. It was revealed that the performance of antenna was not related to the impact damage. Because the impactor did not damage the patch directly. CAS have good impact stability for the antenna performance.

  • PDF