• Title/Summary/Keyword: Performance Counter

Search Result 563, Processing Time 0.026 seconds

Design and Performance Evaluation of a 10kW Scale Counter-Rotating Tidal Turbine (10kW급 상반전 조류터빈의 설계와 성능에 관한 연구)

  • Hoang, Anh Dung;Yang, Chang-Jo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.1
    • /
    • pp.47-53
    • /
    • 2014
  • This paper aims to present the design and performance evaluation of a counter-rotating tidal turbine using CFD and to compare its performance with single rotor. The device scale is 10kW and the rotating part consists of two rotors which rotate in opposite direction. Compared with conventional single rotor, the counter-rotating system shows higher power efficiency at high stream velocity but lower efficiency at low stream velocity. The added counter-rotated rotor together helps improve the energy absorption capacity but has influence on the upstream rotor that reduces its performance. In terms of power capture, the designed counter-rotating tidal turbine is more advantageous in high speed tidal condition.

Prediction for the Performance and Wakes of a Counter-Rotating Wind Turbine Using the Vortex Lattice Method (와류격자기법을 이용한 Counter-Rotating 풍력 발전기의 성능 및 후류 해석 연구)

  • Lee, Seungmin;Son, Eunkuk;Lee, Soogab
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.40.2-40.2
    • /
    • 2011
  • A Counter-rotating wind turbine is one of the new concepts that are proposed to increase the performance of a wind turbine. It has two rotors rotating in the same axis, and it is known that its power coefficient can reach to 0.64 in the ideal case. While the BEMT is widely used to analyze the aerodynamic performance of wind turbines, the analysis of the counter-rotating wind turbine by using it is limited due to the aerodynamic interaction between the two rotors. In this study, the vortex lattice method is used to consider the effect of the front rotor on the rear rotor of the counter-rotating wind turbine and calculate the aerodynamic performance of it. The power and thrust sharing in the two rotors of the counter-rotating wind turbine are predicted and the total power and thrust are compared with that of a single rotor. Moreover, the wake convection and expansion rate is also compared with that of a single rotor.

  • PDF

Humidity Distribution and Performance Variation of a PEMFC Multi Stack System According to the Direction of Anodic Supply (고분자 전해질 연료전지 멀티 스택 시스템의 수소극 흐름방향에 따른 습도분포 및 성능변화)

  • Lee, Yongtaek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.3
    • /
    • pp.143-148
    • /
    • 2018
  • In this study the performance and humidity variation for 2 unit cells connected in series were experimentally measured. The relative flow direction of hydrogen and air was changed from parallel flow to counter flow. Internal humidity distribution was then measured by 5 embedded sensors on each channel. In all experimental conditions, the former unit cell showed a better performance and the gap is noted to be higher when counter flow is applied. The performance was noted to be higher at high humidification case in the parallel flow. However, in the counter flow, the difference of performance according to the humidification is negligible. Hydrogen and air are discharged from the PEMFC unsaturated with water vapor at parallel flow/low humidification condition, which explains lower performance of the PEMFC than other conditions. The humidities in hydrogen and air streams of counter flow were noted to increase rapidly even at low humidification condition and the consequential even hydration of membrane is the reason of higher performance.

Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan (엇회전식 축류홴의 공력 특성에 관한 실험적 연구)

  • Choi, Jin-Yong;Cho, Lee-Sang;Cho, Jin-Soo;Won, Eu-Pil
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

Analysis of Performance Characteristics in the Counter and Parallel Type Plate Evaporator with Operating Methods (대향류와 평행류형 판형 증발기에서 운전방식에 따른 성능특성 분석)

  • Bae, Kyung-Jin;Cha, Dong-An;Kwon, Oh-Kyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.50-56
    • /
    • 2013
  • The analysis of performance characteristics was carried out in the plate type evaporator with counter and parallel flow. To investigate performance of evaporator with water inlet temperature and refrigerant mass flow rate were changed. As a result, when the inlet temperature of water is $8^{\circ}C$, capacity of parallel flow evaporator higher than counter flow is 0.35%. But as the inlet temperature of water rises from $8^{\circ}C$ to $16^{\circ}C$, capacity of counter flow type evaporator higher than parallel flow type is 0.12%, 0.27%, 1.1%, 1.6%, respectively. The findings showed that counter flow type evaporator has a larger capacity than those that were parallel flow type evaporator. As the refrigerant mass flow rate rises, capacity and pressure drop increases in the counter and parallel flow type evaporator.

Development and Performance Test of In-situ Particle Monitoring System using Ion-counter in Vacuum Environments (진공 환경내 실시간 입자 모니터링 시스템의 개발 및 성능평가)

  • Ahn Kang-Ho;Kim Yong-Min;Kwon Yong-Taek
    • Journal of the Semiconductor & Display Technology
    • /
    • v.5 no.1 s.14
    • /
    • pp.45-49
    • /
    • 2006
  • In this paper, a new method that monitors the quantity of particles using ion-counter in vacuum environment is introduced. In-situ particle monitoring (ISPM) system is composed by Gerdien type ion-counter (house-made), DC power supply and electrometer. The ion-counter applied by positive voltage detects only positive charged particles. Therefore the particles to be detected should be in known charge state for further data analysis. ion-counter is installed at the exhaust line of process equipment where the pressure loss is structurally low. ISPM system performance has been verified with SMPS (Scanning Mobility Particle Sizer) system. The correlation coefficient is above 0.98 at the particle size range of $20{\sim}300nm$ in diameter with identified charge distribution under $0.1{\sim}10.0$ Torr.

  • PDF

Design and Performance Evaluation of a 10kW Scale Counter-Rotating Wind Turbine Rotor (10kW급 상반전 풍력터빈 로터의 설계와 성능 평가에 관한 연구)

  • Hoang, Anh Dung;Yang, Chang-Jo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.1
    • /
    • pp.104-112
    • /
    • 2014
  • The counter-rotating approach on wind turbine has been recently put in interest for its certain advantages in both design and performance. This paper introduces a study on a counter-rotating wind turbine designed and modeled using NREL airfoils S822 and S823. The aims of the study is to evaluate and discover the performance of the counter-rotating system, and compares to that of single rotor turbine of same design using numerical simulation. The results show higher performance of the counter-rotating system compared with single rotor case at TSR 3 to 5 but lower performance at higher TSR. This is due to the interaction between upstream and downstream rotors. Thus, the counter-rotating turbine is more efficient at low rotor rotational speed.

Study on the Improvement of Milling Recovery and Performance(I) -Operational Factors Affecting Rice Milling Performance- (도정수율과 성능향상을 위한 연구(I) -벼의 도정성능에 영향을 주는 작동요인-)

  • 정창주;류관희;박예린;이성범
    • Journal of Biosystems Engineering
    • /
    • v.5 no.2
    • /
    • pp.1-14
    • /
    • 1980
  • This study was carried out to investigate the effects of the counter-pressure setting and the roller speed of a rice whitening machine on the head rice recovery. milling capacity and milling efficiency, and also to find out the optimum operational conditions of the machine. The radial pressure inside the whitening chamber and the outlet axial pressure were measured to study their relationships with the head rice recovery, milling capacity and milling efficiency. The results of the study are summarized as follows. (1) The most important factor in rice whitening was the counter-pressure setting. It significantly affected the head rice recovery. (2) The roller speed significant affected the milling capacity and milling efficiency , but it did not affected the head rice recovery. (3) Both the radial pressure and the outlet axial pressure were affected by the counter-pressure setting but not by the roller speed. Both of them increased almost linearly with the counter-pressure setting. There was a significant correlation between the radial pressure and the outlet axial pressure. (4) The flow rate through the whitening chamber when the feed gate was fully opened increased with the roller speed, but it was not affected by the counter-pressure setting. (5) The head rice recovery decreased as the counter-pressure setting increased , but it was not affected by the roller speed. The reason could be explained by the fact that the radical pressure increased only with the counter-pressure setting. (6) The milling capacity increased with the counter-pressure setting and linearly with the roller speed. The milling efficiency generally increased with both the counter-pressure setting and the roller speed. However, the effect of roller speed was negligible at the higher counter-pressure setting. The temperature rise inside the whitening chamber was moderate with the mean of 11.3℃ (range 5.6-18.3℃) even though it increased slightly with the roller speed. Considering the head rice recovery and milling efficiency, the optimum operational conditions of the machine appeared to be the counter-pressure setting of 67g/㎠ and the roller speed of 1,050rpm. Neglecting the small difference in the head rice recovery , the greater milling capacity could be obtained at the counter-pressure setting of 85g/㎠ with the roller speed of 850-1050rpm.

  • PDF

Effects of Deposition Method of Thermally Decomposed Platinum Counter Electrodes on the Performance of Dye-Sensitized Solar Cells (염료 감응형 태양전지 효율에 미치는 백금 상대 전극 제조공정의 영향)

  • SEO, HYUN WOO;BAEK, HYUN DUK;KIM, DONG MIN
    • Journal of Hydrogen and New Energy
    • /
    • v.28 no.1
    • /
    • pp.63-69
    • /
    • 2017
  • In this work, two different platinum (Pt) counter electrodes have been prepared by spin coating a Pt solution and screen printing a Pt paste on fluorine doped tin oxide (FTO) glass substrate followed by sintering at $380^{\circ}C$ for 30 min. Linear sweep voltammetry (LSV) and electrochemical impedance spectroscopy (EIS) analyses of the Pt electrodes showed that the spin coated electrode was catalytically more active than the screen printed electrode. The above result agrees well with the surface morphology of the electrodes studied by atomic force microscopy (AFM) and the photovoltaic performance of the dye-sensitized solar cells (DSSCs) fabricated with the Pt electrodes. Moreover, calculation of current density-voltage (j-V) curves according to diode model with the parameters obtained from the experimental j-V curves and the EIS data of the DSSCs provided a quantitative insight about how the catalytic activity of the counter electrodes affected the photovoltaic performance of the cells. Even though the experimental situations involved in this work are trivial, the method of analyses outlined here gives a strong insight about how the catalytic activity of a counter electrode affects the photovoltaic performance of a DSSC. This work, also, demonstrates how the photovoltaic performance of DSSCs can be improved by tuning the performance of counter electrode materials.

Priority Control Using Delay Counter for ATM Switch (ATM 스위치에서 지연카운터를 이용한 우선순위 제어 기법)

  • 김변곤
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.339-342
    • /
    • 1998
  • The various services that a broadband integrated services digital network (B-ISDN) carries, have a wide range of delay, delay jitter and cell loss probability requirements. Design of appropriate control schemes for B-ISDN is an extremely important and challenging problem. In this paper, we proposes a priority control scheme with a delay counter and a cell counter per each class type. The priority control for required service quality is performed with delay/loss factor obstained by comparing window counter with cell counter. The performance of proposed control scheme is estimated by computer simulation.

  • PDF