• Title/Summary/Keyword: Perchlorate ion

Search Result 62, Processing Time 0.024 seconds

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

Fabrication of Perchlorate Ion Selective PVC Membrane Electrode (과염소산 이온선택성 PVC막전극 제작)

  • 우인성;안형환;강안수
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.4
    • /
    • pp.298-305
    • /
    • 1998
  • The PVC membrane electrode for measuring perchlorate ion was developed by incorporating various quaternary ammonium sallts. The effect of chemical structure, the content of active material, the kind of plasticizers, and the membrane thickness on the electrode characteristic such as the linear response range and Nernstian slope of the electrode were studied. It was obtained that the effect of the chemical structure of an active material on the electrode characteristics was improved with increasing the alkyl chain length of the quarternary ammonium salts in the ascending order of Aliquat 336P, TOAP, TDAP, and TDDAP. The optimum membrane composition was 9.09wt% of TDDAP, 30.3wt% of PVC, and 60.6wt% of plasticizer(DBP). And the optimum membrane thickness was 0.45mm at this composition. Under the above condition, the linear response range was $10^{-1}~1.2\times10^{-6}$M, and the detection limit was $5.1\times10^{-7}$M with the Nernstian slope of 57mV/decade of activity of perchlorate ion. The electrode potential was stable within the pH range from 4 to 11. The selectivity coefficient was as shown below: $SCN^->I^-NO_3^->Br^->ClO_3^->F^->Cl^->SO_4^{2-}$

  • PDF

PET Fabric Supported Fixed Site Carrier Membrane for Selective Metal ion Transport

  • Jin, Long Yi;Mah, Soukil
    • Fibers and Polymers
    • /
    • v.3 no.1
    • /
    • pp.14-17
    • /
    • 2002
  • Development of a novel fixed site carrier membrane (FCM), supported by PET fabric for metal ion separation is reported. The membranes were prepared by dipping PET fabric into the methylene chloride solution of Poly(5-vinyl-m-phe-nylene-m'-phenylene-32-crown-10) (P(VCE)), a polymeric metal ion carrier. It was found that the flux of mono-valent metal ion transported across the membrane is signif=cantly differed from each other and the flux decreases in the order $Cs^+$>$Rb^+$>$K^+$>$Na^+$>$Li^+$ irrespective to the anion except perchlorate anion. It was explained in terms of the stability of the complex, formed by crown ether unit of the P(VCE) and the various metal ions, meanwhile, the lower rate of transport in the presence of perchlorate anion was ascribed to its low hydrophilicity.

Studies on the Crystal Structure of Benzidine Perchlorate by X-ray Diffraction method (II) Crystal Structure Analysis (X-線 廻折法을 利用한 벤지딘過鹽素酸鹽의 結晶構造에 關한 硏究 (II)結晶構造의 解析)

  • Koo, Chung-Hoe;Shin, Hyun-So;Kang, Man-Hyong
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.1
    • /
    • pp.123-126
    • /
    • 1970
  • The approximate crystal structure of benzidine monoperchlorate has been determined by single crystal X-Ray diffraction technique and patterson method. As the molecule has a center of symmetry in it and location of perchlorate ion is symmetrically on the mirror plane in the unit cell, perchlorate ion is forming hydrogen bond with two -$NH_2$ groups in the different molecule. Thus, one molecule of benzidine and perchloric acid combines 1:1 by mole ratio.

  • PDF

Electrochemical Reduction of Perchlorate Using Mercury Film Electrode (수은 막전극을 이용한 수용액 중 과염소산이온의 전기화학적 환원)

  • Myung, Noseung;Kim, Eun Young;Jee, Hyung-Woo;Keum, Narae;Rhee, Insook;Paeng, Ki-Jung
    • Journal of the Korean Electrochemical Society
    • /
    • v.19 no.3
    • /
    • pp.95-100
    • /
    • 2016
  • A method for electrochemical degradation of the perchlorate anion ($ClO_4{^-}$) using mercury film electrode has been studied. Electrochemical method has relatively simple pre-treatment. However, electrochemical method should avoid interference from hydrogen evolution at the applied potential to degradation of perchlorate ion, and thus applied electrode should have large hydrogen overvoltage which suppressed the hydrogen evolution at the working reduction potential to prevent hydrogen evolution. In this study, we used mercury film electrode as a working electrode which has a large overvoltage. Ag / AgCl (sat. NaCl) was used as a reference electrode, and platinum was used as a counter electrode. Mercury film electrode was made by cyclic voltammetry (CV) method. The deposition time was decided as 10 minute, and the stability of the mercury electrode in perchlorate solution was confirmed by CV. The reduction potential of perchlorate was checked by using CV method, and decomposition of perchlorate was performed by using chronoamperometric (CA) method. Also, ion chromatography (IC) was used to confirm the degradation rates of perchlorate.

Effects of Electrolytes in a Liquid Thin Layer System

  • Chung, Taek-Dong
    • Journal of the Korean Electrochemical Society
    • /
    • v.5 no.4
    • /
    • pp.216-220
    • /
    • 2002
  • The effects of electrolytes on electrochemical behavior from an oil thin layer interposed between a graphite electrode and an aqueous solution phase were examined. A hydrophobic electroactive species, tetrachloro-1,4-benzoquinone (TCQ), in a benzonitrile (EN) layer was employed to study ion transfer properties across the BN-water interface. Experimental results showed that hydrophobic cations as well as anions could be successfully used as ionic charge carriers. The addition of various salts into either the oil layers or the aqueous solutions offers deeper insight for the electrochemistry of the liquid thin layer system. When aqueous perchloric acid is interfaced with the BN films, the perchlorate ion of tetrahexylammonium perchlorate (THAP) substantially suppresses the dissociated proton concentration in the layer by the common ion effect while there is only a little change in the total acid concentration. Further approach by theoretical calculation makes it possible to quantitatively understand the effect of the electrolytes to the electrochemical responses of TCQ, which were previously reported (Anal. Chem. 73, 337 (2001)).

Development of Enhanced Analytical Method for Perchlorate in Food by IC-MS/MS with an Internal Standard (IC-MS/MS와 내부표준물질을 이용한 식품 중 perchlorate 분석법 개선)

  • Yang, Min-June;Kim, Jong-Sung;Han, Jong-Hun;Her, Nam-Guk
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.532-536
    • /
    • 2011
  • The internal standard method using ion chromatography combined with tandem mass spectrometry (IC-MS/MS) for quantifying perchlorate in different types of food was established. Because the presence of ions and other biomolecules in matrices usually interrupts accurate determination of perchlorate, it is necessary to develop efficient, reproducible method to determine perchlorate concentrations in food. In this study, the internal standard method was compared with the external standard method to determine perchlorate concentrations in standard samples. The obtained method detection limit (MDL) for perchlorate was 0.005 ${\mu}g/L$ for bottled water, 0.12 ${\mu}g/L$ for milk, 0.27 ${\mu}g/kg$ for rice, 0.16 ${\mu}g/kg$ for vegetables, and 0.07 ${\mu}g/kg$ for seaweed, respectively. The limit of quantitation (LOQ) was calculated by multiplying the MDL by 7. The recoveries of perchlorate from food samples spiked with perchlorate ranged from 98 to 105% and their percent relative standard deviation (%RSD) levels were <20%. This method was successfully applied for the quantitative determination of perchlorate in various kinds of food.

Photoelectrochemical Degradation of Perchlorate Ions by TiO2 (산화티탄의 광전기화학 특성을 이용한 퍼클로레이트 이온 제거)

  • Min, Hyung-Seob;Lee, Jeon-Kook
    • Korean Journal of Materials Research
    • /
    • v.18 no.8
    • /
    • pp.432-437
    • /
    • 2008
  • Titanium oxide films and powders are attached onto carbon cloths via RF reactive sputtering and an epoxy resin mixture, respectively. $TiO_2$/carbon composite materials were used to investigate the photoelectrochemical degradation of perchlorate ions in water. The energy band gaps of the RF-sputtered $TiO_2$ thin films ranged from 3.35-3.44 eV. A photocurrent of the powdered $TiO_2$ as illuminated by ultra-violet light for 30 min. was $2.79\;mA/cm^2$. Perchlorate ions in water were shown to be degradable by a UV-illuminated $TiO_2$ powder/carbon/Nafion/carbon composite.

Removal of Perchlorate from Salt Water Using Microorganisms (미생물을 이용한 염수의 퍼클로레이트 제거)

  • Ahn, Yeonghee
    • Journal of Life Science
    • /
    • v.29 no.11
    • /
    • pp.1294-1303
    • /
    • 2019
  • Perchlorate is an anionic pollutant that is very soluble and stable in water. It has been detected not only in soil/ground water but also in surface water, drinking water, food, fish, and crops. Perchlorate inhibits iodine uptake by the thyroid gland and reduces production of thyroid hormones that are primarily responsible for regulation of metabolism. Although various technologies have been developed to remove perchlorate from the environment, biodegradation is the method of choice since it is economical and environmentally friendly. However there is limited information on perchlorate biodegradation in salt environment such as salt water. Therefore this paper reviews biodegradation of perchlorate in salt water and related microorganisms. Most biodegradation research has employed heterotrophic perchlorate removal using organic compounds such as acetate as electron donors. Biodegradation research has focused on perchlorate removal from spent brine generated by ion exchange technology that is primarily employed to clean up perchlorate-contaminated ground water. Continuous removal of perchlorate at up to 10% NaCl was shown when bioreactors were inoculated with enriched salt-tolerant perchlorate-reducing bacteria. However the reactors did not show long-term stable removal of perchlorate. Microorganisms belonging to ${\beta}$- and ${\gamma}$-Proteobacteria were dominant in bioreactors used to remove perchlorate from salt water. This review will help our understanding of perchlorate removal from salt water to develop a decent biotechnology for the process.

Characteristics of Electrode Potential and AC Impendance of Perchlorate Ion-Selective Electrodes Based on Quaternary Phosphonium Salts in PVC Membranes (제4급 인산염을 이용한 과염소산 이온선택성 PVC막 전극의 전극전위와 AC 임피던스 특성)

  • 안형환
    • Membrane Journal
    • /
    • v.9 no.4
    • /
    • pp.230-239
    • /
    • 1999
  • Perchlorate ion-selective electrodes in PVC membranes that respond linearly to concentration 106 M were developed by incorporating the quaternary phosphonium salts as a canier. The effects of the chemical structure, the contents of canier, the kind of plasticizer and the membrane thickness on electrode characteristics such as the electrode slope, the linear respone range and the detection limit were studied. With this results, the detectable pH range, selectivity coefficients and AC impedance characteristics were compared and investigated. The perchlorate ion substituents of the quaternary phosphonium salts like tetraoctylphosphonium perchlorate (TOPP) , tetraphenylphosphonium perchlorate(TPPP), and tetrabutylphosphonium perchlorate(TBPP) as a canier were used. The electrode characteristics were better in the ascending order of TBPP < TPPP < TOPP, with the increase of carbon chain length of the alkyl group. Dioctylsebacate(OOS) was best as a plasticizer, the canier contents were better with 11.76 wt% and the optimum membrane thickness was 0.19 mm. Under the above condition, the electrode slope was 56.58 mV/$^P{ClO}_4$,the linear response range was $10^{-1}$\times$10^{-6}$ M, the detection limit was 9.66 x $10^{-7}$ M. The performance of electrode was better than Orion electrode. The electrode potential was stable within the pH range from 3 to 11. The order of the selectivity coefficients for the perchlorate ion was sol < F < Br < 1. With the result of impedance spectrum, it was found that the equivalent circuit for the electrode could be expressed by a series combination of solution resistance, parallel circuit consisting of the double layer capacitance and bulk resistance and Warburg impedance. And solution resistance was almost not appeared and Warburg impedance was highly appeared by diffusion. Then Warburg coefficient was 1.32$\times$$10^74 $\Omega$ $\cdot$ ${cm}^2/s^{1/2}$.

  • PDF