• Title/Summary/Keyword: Perceived angle

Search Result 53, Processing Time 0.032 seconds

An Experimental Study for Letter Size Perception (문자의 크기지각에 대한 실험연구)

  • Kim, Hyeon-Jeong;Paik, Jun-Kyung
    • Archives of design research
    • /
    • v.19 no.5 s.67
    • /
    • pp.181-190
    • /
    • 2006
  • This study was designed to investigate how the size perception of letters is influenced by its relation to the ground, visual angle, physical size, letter space and cognitive direction. As a stimulus, a word in the Numeral and Hangul respectively were used in Experiments I and II. Fifty four different configurations consisting of two grounds, three visual angles and nine physical sizes were used as test patterns in Experiment I, and one hundred and eight different configurations consisting of two ground, three directions, two letter spaces and nine physical sizes were used in Experiment II. Subjects were asked to make magnitude estimates for perceived size of test patterns in both Experiments I and II. The results imply that the ground and visual angle affected the perceived size of the Numeral as a focal figure. We found that in Experiment I, the perceived size of the focal letter was clearly underestimated when the rate of physical size was larger than the real size which was a hundred(as the size of standard stimulus), and it was overestimated when the rate of physical size was smaller than a hundred. It was found that the effect of Delboeuf illusion influenced the perceived size of letter. The result of Experiment II shows that the ground, physical size, letter space and the cognitive direction affected the perceived size of Hangul as a focal figure. These findings suggest that size illusion of letters is caused by the size relationship (contrast or assimilation) between a letter perceived as figure and its ground.

  • PDF

Perceptual Localization of a phantom sound image for Ultrahigh-Definition TV (UHD TV를 위한 가상 음상의 인지 위치)

  • Lee, Young-Woo;Kim, Sun-Min
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.9-17
    • /
    • 2010
  • This paper presents a localization perception of a phantom sound image for ultrahigh-definition TV with respect to various loudspeaker configurations; two-horizontal, two-vertical and triplet loudspeakers. Vector base amplitude panning algorithm with modification for non-equidistant loudspeaker setup is applied to create the phantom sound image. In order to practically study the localization performance in real situation, the listening tests were conducted at the on-axis and off-axis positions of TV in normal listening room. A method of adjustment which can reduce the ambiguity of a perceived angle is exploited to evaluate the angles of octave-band signals. The subjects changed the panning angle until the real sound source and virtually panned source were coincident. A spatial blurring can be measured by examining the differences of the panning angles perceived with respect to each band. The listening tests show that the triplet panning method has better performance than vertical panning in view of perceptual localization and spatial blurring at both on-axis and off-axis positions.

Evaluation of Perceived Exertion and Satisfaction in Opening and Closing Tailgates of Sport Utility Vehicles (스포츠 유틸리티 차량의 테일게이트 개폐 불편도와 만족도 평가)

  • Son, Byungchang;Ryu, Taebeum
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.40 no.1
    • /
    • pp.1-10
    • /
    • 2017
  • The difficulties in opening and closing a sport utility vehicle (SUV) tailgate is important aspect of JD (James David) power's Initial Quality Survey (IQS) assessment, and affective quality has a big impact on the the success of thesedays products. The purpose of this study is to evaluate the perceived difficulty and satisfaction of customers by the opening and closing of the tailgate and to grasp the relationship between them and the opening and closing reaction force. The mechanical force required to open and close 42 domestic and overseas SUV tailgates was measured with the help of an auto company. In the experiment, 100 male drivers in their 20s to 50s evaluated perceived difficulty and satisfaction with opening and closing the tailgate. The results of the analysis showed that perceived difficulty and satisfaction were statistically different depending on the vehicle, but did not depend on the personal characteristics of the participants. The perceived difficulty and satisfaction regression model of tailgate opening and closing was developed by mechanical force variables and had a relatively high adjusted $R^2$ ranging from 0.62 to 0.73. The models showed that the the initial close and open force, the difference between initial and maximum close force and the difference between initial and auto-fall angle should be small for the low perceived exertion and high satisfaction. In addition, the correlation analysis between IQS score of tailages and perceived difficulty and satisfaction showed that the IQS scores were more related to the perceived difficulty and satisfaction of closing than those of opening. The results of the study will be helpful to design and test mechanical open and close structure of SUV tailgates.

Development of Vegetation Structure Measurement System using Multi-angle Stereo pair Images

  • DEMIZU Masaki;KAJIWARA Koji;HONDA Yoshiaki
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.170-173
    • /
    • 2004
  • When the data from the artificial satellite is analyzed, recent years it is perceived to vegetation index using BRF(Bi-directional Reflectance Factor) of the observation target. To make the BRF models, it is important to measure the 3D structure of the observation target actually. In this study, it is proposed to the observation technique by using multi-angle stereo pair image, and shown the observation result in grassland area. Also, our team has been operating the radio controlled helicopter which can fly over the tall forest canopy and it can be equipped the measurement system.

  • PDF

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

An EMG Analysis Study of Grinding Work by Posture and Working Time (연삭작업시 작업자세와 작업시간에 따른 근전도 분석에 관한 연구)

  • 배동철;장성록
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.79-83
    • /
    • 2001
  • Posture of the upper limbs in field works is known to be an important risk factor associated with CTD(Cumulative Trauma Disorders). In particular, uncomfortable posture and highly repetitive works in shipbuilding industry(for instance, sand blasting, grinding and blast painting, etc) made workers exposed to a great risk of injuries. The purpose of this paper is to analyze recruitment pattern of the muscles according to posture(joint angle displacement) during grinding. In this study, EMG signals of pectoralis major, latissimus dorsi, and posterior deltoid muscle were measured and analyzed from FlexComp EMG solution. And subjective ratings of perceived exertion were made using Borg's CR-10 rating scale.

  • PDF

Comparison of the Joint Position Sense at Knee Joint According to Surface Conditions (지지 면 조건에 따른 무릎관절의 관절 위치 재현능력 비교)

  • Hong, Young-Ju;Weon, Jong-Hyuck;Kwon, Oh-Yun
    • Physical Therapy Korea
    • /
    • v.14 no.3
    • /
    • pp.90-96
    • /
    • 2007
  • The purpose of this study was to compare the joint position sense at the knee joint at 3 different surface conditions by using the active knee joint angle reproduction test in the standing position. Twenty healthy volunteers (10 males and 10 females) age 20~29 years were recruited for this study. The knee joint position senses were assessed at three different surface conditions: on the floor (stable condition), TOGU (soft condition), and seat fit (unstable condition) in a closed kinetic chain. Testing orders were selected randomly. The absolute angle error was defined as the absolute difference between target angles ($30^{\circ}{\sim}45^{\circ}$ knee flexion) and subject perceived angle of the knee flexion. One way ANOVA was used to compare the absolute angle of error among 3 different conditions. The Independent t-test was used to compare the absolute angle of error between male and female. The error angles were significantly different among surface conditions ($1.3^{\circ}{\pm}1.2^{\circ}$ for the floor, $2.1^{\circ}{\pm}0.9^{\circ}$ for the TOGU, and $4.4^{\circ}{\pm}1.8^{\circ}$ for the seat fit, p<.05). There was no significant difference in error angle between male and female. In conclusion, the joint position sense of the knee joint in the closed kinetic chain decreased at unstable surface conditions. The result of this study indicates that surface conditions should be considered when assessing and training the joint position sense of the knee joint in clinical setting.

  • PDF

Proposal of a Movable Armrest for Preventing the Musculoskeletal Disorders (VDT작업에서의 근골격계 질환 예방을 위한 새로운 팔 지지대 제안)

  • Park, Gyeong-Su;Kim, Sang-Su;Jo, Il-Haeng;Hong, Gi-Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.1-10
    • /
    • 2006
  • In spite of the rapid increase of computer use in our everyday life, not much effort is undertaken to take measures to prevent Musculoskeletal Disorders(MSDs). In this paper, we suggest a movable armrest which would lower the exposure to the MSDs, especially on the vicinity of arm. The aim of this study is to determine whether there are differences in wrist angle variations, forearm muscular loads, comfort and normal performance between the invented movable armrest and a conventional armrest when using a computer mouse. Eight experienced VDU workers performed a standardized simple task set which consists of 15 detailed tasks with each armrest. The wrist angle variations in the right arm were registered by electrogoniometer and the muscle activities in the shoulder, deltoid and two extensors in the forearm were also registered by electromyograph. The subjects rated perceived comfort while performing the tasks with each armrest. Working with the invented armrest, compared to general, gave significantly decreased wrist angle variations at most of the detailed tasks of both biaxial movements. Moreover, as the distance of targets increased, the difference of muscle activities in two different situations trend to be increasing. At the same time, in work with invented armrest, the subjects rated more comfort and they showed decreased normal performances in 8 detailed tasks which were mainly caused by macro moving time.

Properties of Indium Tin Oxide Multilayer Fabricated by Glancing Angle Deposition Method

  • Oh, Gyujin;Lee, Kyoung Su;Kim, Eun Kyu
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.367-367
    • /
    • 2013
  • Commercial applications of indium tin oxide (ITO) can be separated into two useful areas. As it is perceived to bear electrical properties and optical transparency at once, its chance to apply to promising fields, usually for an optical device, gets greater in the passing time. ITO is one of the transparent conducting oxides (TCO), and required to carry the relative resistance less than $10^{-3}{\Omega}$/cm and transmittances over 80 % in the visible wavelength of light. Because ITO has considerable refractive index, there exist applications for anti-reflection coatings. Anti-reflection properties require gradual change in refractive index from films to air. Such changes are obtained from film density or nano-clustered fractional void. Glancing angle deposition (GLAD) method is a well known process for adjusting nanostructure of the films. From its shadowing effects, GLAD helps to deposit well-controlled porous films effectively. In this study, we are comparing the reference sample to samples coated with controlled ITO multilayer accumulated by an e-beam evaporation system. At first, the single ITO layer samples are prepared to decide refractive index with ellipsometry. Afterwards, ITO multilayer samples are fabricated and fitted by multilayer ellipsometric model based on single layer data. The structural properties were measured by using atomic force microscopy (AFM), and by scanning X-ray diffraction (XRD) measurements. The ellipsometry was used to determine refractive indices and extinction coefficient. The optical transmittance of the film was investigated by using an ultraviolet-visible (UV-Vis) spectrophotometer.

  • PDF

The Visual Changes of Colors by the Measuring Angle of Cotton/PET Union Fabrics (면(綿)/PET 교직물(交織物)의 측정각(測定角)에 따른 색변화 연구(色變化 硏究))

  • Lee, Mi-Kyung
    • Journal of Fashion Business
    • /
    • v.10 no.4
    • /
    • pp.151-162
    • /
    • 2006
  • This study investigated into the effects of the colors of warp and weft on the overall colors of fabrics, along with the visual changes of colors by the measuring angle of both warp and weft, by means of cross-dyeing of cotton/PET union fabrics. First, the reflectance of polyester is higher than that of cotton over the whole wavelength. Second, the dyeing of polyester uses the disperse dyes and that of cotton uses fiber-reactive dyes, the differences in the features of dyes and the reflectance of fabrics cause the same colors to be perceived different by the angle of observation. Third, the dyeing of cotton and PET fabrics individually with the same color revealed that the dyeing of cotton and PET fabrics in one bath resulted in a small difference in colors between the two fabrics than the separate dyeing in two bathes. In the case of one bath, the dyeing of PET fabrics followed by that of cotton fabrics resulted in a small difference in color than the dyeing in the reversed order. Fourth, when cotton/PET union fabrics were dyed in ten colors, the difference in colors between the two fabrics was small; and due to the difference in the density of warp and weft of union fabrics, some difference was detected in comparison with the results of separate dyeing of cotton and PET fabrics in one bath. The latter did not produce the changes in color which was recognizable with the naked eyes. Fifth, when cotton/PET union fabrics were dyed in ten colors, any color change was not observed by the measuring angle, and the inclination in the direction of warp or weft resulted in the tendency of color-deepening. In the measurement of the latter, the inclination in the direction of weft resulted in the higher color-deepening than that in the direction of warp, due to the influence of weft.