Characteristics of Enzyme Sensors using Carboxylated PVC for Immobilizing Penicillinase (Carboxylated PVC에 페니실리나제를 고정한 효소 센서의 특성)

  • Kim, Ki-Myo;Kim, Young-Hak;Lee, Eun-Yup;Hur, Moon-Hye;Ahn, Moon-Kyu
    • YAKHAK HOEJI
    • /
    • v.40 no.1
    • /
    • pp.72-77
    • /
    • 1996
  • Penicillin sensor was manufactured by immobillizing penicillinase with glutaraldehyde on the $H^+$-selective membrane based on PVC-COOH-TDDA. This membrane was not inter fered by $K^+$ ion in Pc-G potassium salt. When enzyme was immobilized with glutaraldehyde, the PVC-COOH matrix was more effective than PVC matrix. Calibration curve calculated from Nernst equation was not linear. But potential was relative to concentration of Pc-G. And maximal potentiometric velocity was also relative to concentration of Pc-G. Therefore, it may be applied to Michaelis-Menten equation. The penicillin sensor was useful for determination of Pc-G at concentration of 0.1~10mM level.

  • PDF

Light addressable potentiometric penicillin sensor using Ta2O5 sensing membrane (Ta2O5 감지막의 광지시 전위차형 페니실린 센서)

  • Lee, Sun-Young;Jang, Su-Won;Kim, Jae-Ho;Kwon, Dae-Hyuk;Kim, Eung-Soo;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2006
  • In this study, the light addressable potentiometric sensors (LAPS) with $Si_{3}N_{4}/SiO_{2}/Si$, and $Ta_{2}O_{5}/SiO_{2}/Si$ structures were fabricated. The penicillinsae was immobilized on the devices to hydrolyze the penicillin using self-assembled monolayer (SAM) method. Then response characteristics according to the penicillin concentrations were measured and compared. The measuring system was simplified by using LabVIEW. The pH response characteristics of fabricated devices are 56 mV/pH ($Si_{3}N_{4}$ sensing membrane) and 61 mV/pH ($Ta_{2}O_{5}$ sensing membrane). The sensitivity of sensor by enzyme reaction result of the enzyme reaction were 60 mV/decade and 74 mV/decade for $Si_{3}N_{4}/SiO_{2}/Si$ and $Ta_{2}O_{5}/SiO_{2}/Si$ structure, respectively, in the range of $0.1\;mM{\sim}10\;mM $of the penicillin concentration.

Optimal Immobilization of Penicillinase for Ion-selective Electrode

  • Hur, Moon-Hye;Kang, Hee-Jin;Min, Hye-Young;Lee, Ji-Yeun;Lee, Ki-Hyun;Ahn, Moon-Kyu
    • Archives of Pharmacal Research
    • /
    • v.20 no.1
    • /
    • pp.68-71
    • /
    • 1997
  • Penicillin sensor was prepared by immobilizing penicillinase (Pcase) on $H^{+}$-selective carboxylated poly (vinyl chloride) (PVC-COOH) membrane or cellulose filter membrane. The immobilization techniques are as follows. Pcase was immobilized with GTH on $H^{+}$-selective PVC-COOH membrane or some amount of BSA was dropped on that membrane. Another method to make immobilization is to mix type I Pcase with GTH and drop on a cellulose filter membrane. According to immobilization techniques, there were some differences in response properties of enzyme electrodes, however, all electrodes responded to Pcase-resistant penicillin derivatives. Pcase immobilized on cellulose filter membrane with $H^{+}$-selective PVC membrane eletrode was more stable and more sensitive to penicillinase-resistant penicillin derivatives than any other immobilization techniques.

  • PDF

Fabrication and Response Characteristics of the Light Addressable Potentiometric Sensor for Detecting the Penicillin Concentration (페니실린 농도 검출을 위한 광지시형 전위차 센서의 제작 및 감응특성)

  • Jang, Su-Won;Jung, Young-Hee;Park, Jin-Ho;Kim, Jea-Ho;Kwon, Dae-Hyuk;Lee, Seung-Ha;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.356-362
    • /
    • 2004
  • In this study, we developed the measuring system based on light addressable potentiometric sensor for the quantitative analysis of penicillin that is very important element in medicine and pharmacy, clinic. It is investigated the response characteristics by enzyme reaction with penicillinase. First, the surface pre-treatment process of the $Si_{3}N_{4}$ was established. The coupling agent was made using self assembled monolayer method and it was confirmed the immobilization process by AFM. Also, as the measuring system, potentiostat, signal processing part etc. was made by Lab VIEW software, it was reduced detecting time as well as simplifying the system. Fabricated device was shown excellent pH response characteristics, 57 mV/ pH in the range of pH $2{\sim}11$. The response characteristics was 60 mV/decade in the range of $0.1{\sim}10{\;}mM$.