• Title/Summary/Keyword: Penetration resistance test

Search Result 404, Processing Time 0.028 seconds

Setting Assessment of Hogh Strength Concrete Using the Ultrasonic Pulse Velocity Monitoring (초음파 속도 모니터링에 의한 고강도 콘크리트의 응결 평가)

  • 이회근;이광명
    • Journal of the Korea Concrete Institute
    • /
    • v.14 no.6
    • /
    • pp.973-981
    • /
    • 2002
  • Recently, the use of high strength concrete (HSC) has increased dramatically md however, few studies have been conducted on the early-age properties of HSC such as setting. The penetration resistance test (specified by KS F 2436) that is the standard test method for determining initial and final setting times of concrete, may not be appropriate for HSC because of the high viscosity of the mortar mixture. To address this issue, an ultrasonic pulse velocity (UPV) monitoring system was used to investigate the setting behavior of mortar and concrete. The experimental study was carried out to measure the UPV's of mortars and concretes having various water/binder ratios (W/B) and various fly ash replacement levels, during the first 24 hours of testing. Test results showed that the UPV in concrete was developed faster than that of mortar with the same W/B, and that of ordinary concrete was greater than that of fly ash concrete. Typical values of UPV were suggested that correspond to the initial and final setting times, based on following criteria: (1) the penetration resistance method; (2) the instant when the UPV begins to develop; and (3) the instant when the UPV development rate is maximum. The method and UPV monitoring device used in this study is promising for the setting assessment of concrete, particularly for HSC.

Preparation and Properties of Printing Rubber Roller : (I) Oil Resistance and Mechanical Properties of Butabiene Rubber/Nitrile Rubber Compounds (인쇄용 고무roller의 제조와 물성: (I) 부타디엔고무와 니트릴고무 혼련물의 내유성 및 기계적 성질)

  • 박찬영
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.18 no.2
    • /
    • pp.83-101
    • /
    • 2000
  • In this experiment butadiene rubber(BR)/acrylonitrile butadiene rubber(NBR) blends was prepared and then the applicability of BR/NBR blends as printing rubber roller was examined. With the aid of open 2-roll mill, BR, NBR and another chemical additives were compounded. Then rubber vulcanizates were manufactured by hot press and maximum torque, Mooney viscosity, mechanical properties and oil resistance of the test specimens were measured. With prolonged oil aged treating time, BR/NBR blends became soft and so the hardness of blends decreased. It could be explained by the swelling of rubber matrix with oil penetration in to rubber molecules. The undesirable low value of oil resistance of BR was significantly improved by blending BR with NBR.

  • PDF

Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • The purpose of this experimental research is to evaluate the resistance of reinforcement corrosion and chloride ion penetration of high volume fly ash (HVFA) concrete. For this purpose, concrete test specimens were made for various strength level and replacement ratio of fly ash, and then compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91 and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that compressive strength of HVFA concrete was decreased with increasing replacement ratio of fly ash but long-term resistance against reinforcement corrosion and chloride ion penetration of that was increased.

Fundamental Study on High Strength and High Durability Cement Concrete Pavement: Part II Strength and Durability Evaluations (시멘트콘크리트 포장의 고강도 고내구성을 위한 기초 연구 : Part II 최적배합콘크리트의 강도 및 내구특성 분석)

  • Yun, Kyong-Ku;Park, Cheol-Woo;Hong, Seung-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.51-60
    • /
    • 2009
  • This study investigates the fresh state characteristics, strength, chloride ion penetration resistance and freeze-thaw resistance of the suggested high strength-high durability cement concrete pavement. The required workability and air content could be achieved by using an appropriate admixtures. However its dosage should be carefully determined through field trial batches. Compressive strength increased with the increased cement content and, in particular, high cement volume concrete continuously developed strength up to 90 days. No clear relationship, however, existed between flexural strength and cement content. Chloride penetration resistance seemed as a function of curing age rather than the cement content. Freeze-thaw resistance test was conducted using two different coolants, tap water and 4% NaCl solution. When the tap water was used no severe damage was observed up to 300 cycles regardless the air content. Under 4% NaCl solution, specimens of 326kg/$m^3$ cement content showed severe damage with surface scaling. Based on the experimental investigations herein, it is highly recommended that the cement content be greater than 400kg/$m^3$ for strength-high durability cement concrete pavement structures.

  • PDF

Performance Evaluation of Bridge Deck Materials based on Ordinary Portland Cement Concrete (보통 포틀랜드 콘크리트 기반 교면포장 재료 성능 평가)

  • Nam, Jeong-Hee;Jeon, Seong Il;Kwon, Soo Ahn
    • International Journal of Highway Engineering
    • /
    • v.19 no.6
    • /
    • pp.129-137
    • /
    • 2017
  • PURPOSES : The purpose of this study is to develop bridge deck concrete materials based on ordinary Portland cement concrete, and to evaluate the applicability of the developed materials through material properties tests. METHODS : For field implementation, raw material (cement, fine aggregate, and coarse aggregate) properties, fresh concrete properties (slump and air content), strength (compressive, flexural and bond strength) gain, and durability (freeze-thaw resistance, scaling resistance, and rapid chloride penetrating resistance) performance were evaluated in the laboratory. RESULTS : For the selected binder content of $410kg/m^3$, W/B = 0.42, and S/a = 0.48, the following material performance results were obtained. Considering the capacity of the deck finisher, a minimum slump of 150 mm was required. At least 6 % of air content was obtained to resist freeze-thaw damage. In terms of strength, 51.28 MPa of compressive strength, 7.41 MPa of flexural strength, and 2.56 MPa of bond strength at 28 days after construction were obtained. A total of 94.9 % of the relative dynamic modulus of elasticity after 300 cycles of freeze-thaw resistance testing and $0.0056kg/m^2$ of weight loss in a scaling resistance test were measured. However, in a chloride ion penetration resistance test, the result of 3,356 Coulomb, which exceeds the threshold value of the standard specification (1000 Coulomb at 56 days) was observed. CONCLUSIONS : Instead of using high-performance modified bridge deck materials such as latex or silica fume, we developed an optimum mix design based on ordinary Portland cement concrete. A test construction was carried out at ramp bridge B (bridge length = 111 m) in Gim Jai City. Immediately after the concrete was poured, the curing compound was applied, and then wet mat curing was applied for 28 days. Considering the fact that cracks did not occur during the monitoring period, the applicability of the developed material is considered to be high.

A Study on the Chloride ion Penetration Characteristic of Concrete containing Ground Granulated Blast Furnace Slag (고로슬래그미분말 치환 콘크리트의 염화물 침투특성에 관한 연구)

  • 김현수;지남용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.997-1002
    • /
    • 2001
  • There are two types of chloride in concrete; one is added as concrete materials' chloride when concrete's mixing, and .the other is penetrated from the air and sea water in the sea-shore area. These chlorides penetrate into concrete, and they are accumulated inside the concrete with aging. This study aimed to evaluate the chloride ion penetration resistance of concrete containing GGBFS in the sea-shore area. Therefore, the specimens made with the replacement ratios(0, 0.30, 0.45, 0.60) of GGBFS were put into 3% NaCl solution according to the chloride accelerating test of JCI-SC3, and then investigated the weight changes, compressive strength, chloride ion with the depths of the specimens by aging. The result is that the diffusion coefficient of chloride ion is decreased with the increase of replacement ratios when compared to OPC

  • PDF

Automatic categorization of chloride migration into concrete modified with CFBC ash

  • Marks, Maria;Jozwiak-Niedzwiedzka, Daria;Glinicki, Michal A.
    • Computers and Concrete
    • /
    • v.9 no.5
    • /
    • pp.375-387
    • /
    • 2012
  • The objective of this investigation was to develop rules for automatic categorization of concrete quality using selected artificial intelligence methods based on machine learning. The range of tested materials included concrete containing a new waste material - solid residue from coal combustion in fluidized bed boilers (CFBC fly ash) used as additive. The rapid chloride permeability test - Nordtest Method BUILD 492 method was used for determining chloride ions penetration in concrete. Performed experimental tests on obtained chloride migration provided data for learning and testing of rules discovered by machine learning techniques. It has been found that machine learning is a tool which can be applied to determine concrete durability. The rules generated by computer programs AQ21 and WEKA using J48 algorithm provided means for adequate categorization of plain concrete and concrete modified with CFBC fly ash as materials of good and acceptable resistance to chloride penetration.

Corrosion Measurements on Reinforcing Rebars in Reinforced Concrete Specimen (철근 콘크리트 시험편의 철근방식에 관한 측정법)

  • 이강균;장지원;한기훈;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.281-286
    • /
    • 1997
  • Recent construction activities and maintenance of marine facilities have been accelerating to keep up with rapid economic growth in Korea. Marine concrete structures are exposed to salts an chloride from ocean environments. The corrosion of reinforcement steel caused by chloride-penetration into concrete may severely effect the durability of concrete structures. The objective of this research is to develop a durable concrete by investigating the corrosion resistance of various corrosion protection systems utilizing different water/cement ratio, silica fumes, corrosion inhibitors and etc. A tow-year verification test on various corrosion protection systems has been doing in the laboratory and at the seaside. Corrosion investigations on reinforcement steel are now under progress for more than 180 concrete specimen. Corrosion-related measurements include macrocell corrosion current, instant-off voltage between corroding and noncorroding reinforcement, chloride contents, the corroded surface areas on the reinforcement steel, and etc. A low level of corrosion is investigated on reinforcement steels in concrete specimen made with corrosion inhibitors or applied aqueous impregnating corrosion inhibitors into their surface, even though high chloride contents of concrete specimen.

  • PDF

A study on the heat insulation performance of vapor penetration-insulate complex waterproofing system. (수증기 투과형 단열 복합 방수 시스템의 단열 성능에 관한 연구)

  • Choi, Su-Young;An, Ki-Won;Jang, Duk-Bae;Kim, Jong-Phil;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.62-63
    • /
    • 2016
  • In addition to the waterproof sheet waterproof objectives that apply to the building roof it is being constructed, including a complex such as insulation performance, root-resistance. However, thermal insulation of the composite waterproofing sheet is an insulating effect a wide variety depending on the specific construction -specific, material and even the effect is this part of the test to the generation when insignificant compared to each other a number of roof insulation effect of the insulation composite waterproof sheet that is currently in effect analysis.

  • PDF

Assessment of the effect of sulfate attack on cement stabilized montmorillonite

  • Kalipcilar, Irem;Mardani-Aghabaglou, Ali;Sezer, Gozde Inan;Altun, Selim;Sezer, Alper
    • Geomechanics and Engineering
    • /
    • v.10 no.6
    • /
    • pp.807-826
    • /
    • 2016
  • In this study, aiming to investigate the effects of sulfate attack on cement stabilized highly plastic clay; an experimental study was carried out considering the effects of cement type, sulfate type and its concentration, cement content and curing period. Unconfined compressive strength and chloride-ion penetration tests were performed to obtain strength and permeability characteristics of specimens cured under different conditions. Test results were evaluated along with microstructural investigations including SEM and EDS analyses. Results revealed that use of sulfate resistance cement instead of normal portland cement is more plausible for soils under the threat of sulfate attack. Besides, it was verified that sulfate concentration is responsible for strength loss and permeability increase in cement stabilized montmorillonite. Finally, empirical equations were proposed to estimate the unconfined compressive strength of cement stabilized montmorillonite, which was exposed to sulfate attack for 28 days.