• Title/Summary/Keyword: Penetration level

Search Result 406, Processing Time 0.021 seconds

Simulation of Unsaturated Fluid Flow on the 2nd Phase Facility at the Wolsong LILW Disposal Center (경주 중저준위방폐장 2단계 처분시설의 불포화 환경하에서 침투수 유동 해석)

  • Ha, Jaechul;Lee, Jeonghwan;Yoon, Jeonghyoun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.3
    • /
    • pp.219-230
    • /
    • 2017
  • This study was conducted to predict and evaluate the uncertainty of safety after closure of the second phase surface disposal facility of the Gyeongju intermediate and low level repository in Korea. In this study, four scenarios are developed considering both intact and degraded states of multi-layered covers and disposal containers; also, the fluid flow by a rainfall into the disposal facility is simulated. The rainfall conditions are implemented based on the monthly average data of the past 30 years (1985~2014); the simulation period is 300 years, the management period regulated by institutional provisions. As a result of the evaluation of the basic scenario, in which the integrity of both of the containers and the covers is maintained, it was confirmed that penetration of rainfall does not completely saturate the inside of the disposal facility. It is revealed that the multiple cover layers and concrete containers effectively play the role of barrier against the permeation of rainfall.

A Study on Voice Phishing Countermeasures of the Police (보이스피싱에 대한 경찰의 대응방안에 관한 연구)

  • Kim, Duck-Yong
    • Journal of Digital Contents Society
    • /
    • v.19 no.1
    • /
    • pp.193-198
    • /
    • 2018
  • In Korea, the penetration rate of Internet, telephone and smart devices is reaching the highest level in the world. Cyber financial crimes that exploit such infrastructures continue to evolve. Since the first Voice Phishing crime in May 2006, ten years later, there has been a constant occurrence of Voice Phishing crime. Voice Phishing is a crime in which a victim is phoned for false information to figure out the victim's account number and password. This method of Voice Phishing evolves day by day, and it is difficult to investigate. Most of Voice Phishing is a form of international organized crime that is based in Southeast Asia such as China, and it is not easy to eradicate by international cooperation investigation. The purpose of this study is to investigate the actual situation and case analysis of Voice Phishing crime, and to propose the countermeasures against police Voice Phishing counterplan.

A Study on the Power Management Algorithm of Centralized Electric Vehicle Charging System (중앙제어기반 전기자동차 충전시스템의 에너지관리 알고리즘에 관한 연구)

  • Do, Quan-Van;Lee, Seong-Joon;Lee, Jae-Duck;Bae, Jeong-Hyo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.566-571
    • /
    • 2011
  • As Plug-in Hybrid Vehicle and Electric Vehicle (PHEV/EV) take a greater share in the personal automobile market, their high penetration levels may bring potential challenges to electric utility especially at the distribution level. Thus, there is a need for the flexible charging management strategy to compromise the benefits of both PHEV/EV owners and power grid side. There are many different management methods that depend on the objective function and the constraints caused by the system. In this paper, the schema and dispatching schedule of centralized PHEV/EV charging spot network are analyzed. Also, we proposed and compared three power allocation strategies for centralized charging spot. The first strategy aims to maximize state of vehicles at plug-out time, the rest methods are equalized allocation and prioritized allocation based on vehicles SoC. The simulation results show that each run of the optimized algorithms can produce the satisfactory solutions to response properly the requirement from PHEV/EV customers.

APICAL SEALING OF THERMAFIL OBTURATORS IN CURVED CANALS (만곡근관에서 Thermafil의 근단폐쇄성에 관한 실험적 연구)

  • Ha, Joo-Hee;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.20 no.2
    • /
    • pp.671-684
    • /
    • 1995
  • The purpose of this study was to compare the apical sealing ability, overfilling and obturation of lateral canals using two gutta-percha techniques: Thermafil obturators and cold lateral condensation. Eighty numbered epoxide blocks with one major and five lateral canals were divided into four experimental groups and obturated according to experimental groups. Four experimental groups were as follows: Group 1 : Filling with Thermafil plastic obturators and sealer(ThermaSeal) Group 2 : Filling with Thermafil plastic obturators only, without sealer(ThermaSeal) Group 3 : Fillng using lateral condensation with sealer(AH-26) Group 4 : Fillng using lateral condensation without sealer(AH-26) All the blocks were stored in 100% relative humidor at room temperature for 7 days. Each block was placed in centrifuge tube filled with India ink, and then centrifuged for 20 minutes at 3,000 rpm. Apical leakage was measured from the apical foramen to the most coronal level of dye penetration in millimeter under a stereoscope. The length of gutta-percha and sealer in each of the lateral canals was measured, too. The presence or absence of overfilling of gutta-percha and sealer was recorded. The data was analyzed by one-way ANOVA. The obtained results were as follows: l. Apical dye leakage was almost: not occurred in Group Willed with Thermafil and sealer) and Group 3(filled using lateral condensation with sealer), and there was no significant difference in linear leakage between two groups(p>0.01). 2. In both Thermafil and lateral condensation groups, linear leakage of Group I, 3(filled with sealer) was less than that of Group 2, 4(filled without sealer), and there was no significant difference in linear leakage between Group 1, 2, 3(p> 0.01). 3. Overfilling during obturation of Group 1, 2(filled with Thermafil) was more than Group 3, 4(filled using lateral condensation), and there was no significant difference between groups(p> 0.05). 4. Groups filled with Thermafil had significantly more gutta-percha than groups filled using lateral condensation in all lateral canals(p <0.01), the total length of gutta-percha and sealer found in all lateral canals were similar in Group 1 and Group 3.

  • PDF

Evaluation of Voltage Sag and Unbalance due to the System Connection of Electric Vehicles on Distribution System

  • Lee, Soon-Jeong;Kim, Jun-Hyeok;Kim, Doo-Ung;Go, Hyo-Sang;Kim, Chul-Hwan;Kim, Eung-Sang;Kim, Seul-Ki
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.2
    • /
    • pp.452-460
    • /
    • 2014
  • Due to increased concerns for rising oil prices and environmental problems, various solutions have been proposed for solving energy problems through tightening environmental regulations such as those regarding $CO_2$ reduction. Among them, Electrical Vehicles (EVs) are evaluated to be the most realistic and effective approach. Accordingly, research and development on EVs and charging infrastructures are mainly proceeding in developed countries. Since EVs operate using electric energy form a battery, they must be connected to the power system to charge the battery. If many EVs are connected during a short time, power quality problems can occur such as voltage sag, voltage unbalance and harmonics which are generated from power electronics devices. Therefore, when EVs are charged, it is necessary to analyze the effect of power quality on the distribution system, because EVs will gradually replace gasoline vehicles, and the number of EVs will be increased. In this paper, a battery for EVs and a PWM converter are modeled using an ElectroMagnetic Transient Program (EMTP). The voltage sag and unbalance are evaluated when EVs are connected to the distribution system of the Korea Electric Power Corporation (KEPCO). The simulation results are compared with IEEE standards.

Evaluation of Service Life in RC Column under Chloride Attack through Field Investigation: Deterministic and Probabilistic Approaches (염해 실태조사를 통한 철근 콘크리트 교각의 내구수명 평가 - 결정론적 및 확률론적 해석방법)

  • Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.19 no.5
    • /
    • pp.67-74
    • /
    • 2015
  • RC (Reinforced Concrete) structures are considered as cost-benefit and durable however performances of structural safety and durability are degraded due to steel corrosion. Service life in RC structure is differently evaluated due to different local environmental conditions even if it is exposed to the same chloride attack. In the paper, 25 concrete cores from field investigation are obtained from 4 RC columns with duration of 3.5~4.5 years exposed to sea water. Through total chloride content measurement, surface chloride contents and apparent diffusion coefficients are evaluated. Service life of the target structure is estimated through deterministic method based on Fick's $2^{nd}$ Law and probabilistic method based on durability failure probability, respectively. Probability method is evaluated to be more conservative and relatively decreased service life is evaluated in tidal zone and splash zone over 40.0 m. Chloride penetration behavior with coring location from sea level and the present limitations of durability design method are investigated in the paper.

SPECTROPHOTOMETRIC EVALUATION OF SEALING EFFECTS OF SEVERAL ROOT-END FILLING MATERIALS (분광광도법을 사용한 수종 역충전재의 근단부 폐쇄효과에 관한 연구)

  • Yi, Jin-Gyu;Park, Sang-Jin;Choi, Kyung-Kyu;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.6
    • /
    • pp.449-456
    • /
    • 2003
  • The purpose of this study is to evaluate the sealing effect of several root-end filling materials using spectrophotometric analysis. 180 single root teeth with one canal were instrumented and canal filled. Root resected and root end preparation was made. Teeth were randomly classified to S experimental group(MTA, EBA, IRM, TCP, ZOE) and 1 control group according to root-end filling material MTA group used PRO ROOT MT A, EBA group used Super EBA. TCP group used NEW APATITE LINER TYPE II main component of which is ${\alpha}-tricalcium$ phosphate (TCP). According to manufacture's instruction experimental material was mixed and retrfilled. After 2% methylene blue solution penetration absorbance for each test sample was measured with spectrophotometer (JASCO UV-530, Japan). The mean absorbance of control and experimental group was as follows; MTA: 0.092, IRM: 0.226, Super EBA: 0.255, ZOE: 0.374, Control: 0.425, TCP: 0.501 and the result analyzed by Turkey test at P=0.05 level. Conclusions of this study are as follows; 1. The absorbance increase in following sequence MTA, IRM, Super EBA, ZOE, Control. TCP. 2. MTA showed the least leakage but was not significant with IRM or Super EBA and was significant with control or TCP(p<0.05). 3. TCP had the most leakage and was not significant with control group.

Capacity assessment of existing corroded overhead power line structures subjected to synoptic winds

  • Niu, Huawei;Li, Xuan;Zhang, Wei
    • Wind and Structures
    • /
    • v.27 no.5
    • /
    • pp.325-336
    • /
    • 2018
  • The physical infrastructure of the power systems, including the high-voltage transmission towers and lines as well as the poles and wires for power distribution at a lower voltage level, is critical for the resilience of the community since the failures or nonfunctioning of these structures could introduce large area power outages under the extreme weather events. In the current engineering practices, single circuit lattice steel towers linked by transmission lines are widely used to form power transmission systems. After years of service and continues interactions with natural and built environment, progressive damages accumulate at various structural details and could gradually change the structural performance. This study is to evaluate the typical existing transmission tower-line system subjected to synoptic winds (atmospheric boundary layer winds). Effects from the possible corrosion penetration on the structural members of the transmission towers and the aerodynamic damping force on the conductors are evaluated. However, corrosion in connections is not included. Meanwhile, corrosion on the structural members is assumed to be evenly distributed. Wind loads are calculated based on the codes used for synoptic winds and the wind tunnel experiments were carried out to obtain the drag coefficients for different panels of the transmission towers as well as for the transmission lines. Sensitivity analysis is carried out based upon the incremental dynamic analysis (IDA) to evaluate the structural capacity of the transmission tower-line system for different corrosion and loading conditions. Meanwhile, extreme value analysis is also performed to further estimate the short-term extreme response of the transmission tower-line system.

Management of Chronic Aspiration Caused by High Vagal Palsy (상부미주신경마비에 의한 만성흡인의 치료)

  • 성명훈;김광현;김동영;박민현;고태용;김춘동
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.52-58
    • /
    • 1998
  • BACKGROUND: Aspiration is defined as the laryngeal penetration of secretions below the level of the true vocal cords. Aspiration can result in life-threatening complications, such as bronchospasm, airway obstruction, pneumonia, pulmonary abscess, sepsis, and death. The patient with high vagal palsy had significant aspiration and dysphagia OBJECTIVE: To formulate a step-by-step management paradign for the patients with high vagal palsy MATERIALS AND METHODS : The medical records of 23 patients who were diagnosed as high vagal palsy from September, 1995 to April, 1998 in Seoul National University Hospital were reviewed retrospectively. Eleven patients were managed conservatively and 12 patients were operated to treat chronic aspiration. RESULTS : The main etiologies of high vagal palsy were mass lesions of the skull base such as neurogenic tumor, pseudotumor, meningioma or nasopharyngeal carcinoma. Aspiration and dysphagia improved in 7 out of 11 patients who were managed conservatively after 2.2 months on the average. The patients who were refractory to the conservative management underwent surgery and showed improvement in 10 out of 12 patients. The employed surgical modalities were vocal cord medialization combined with cricopharyngeal myotomy in 7 patients, laryngotracheal separation in 3 patients and arytenoid adduction only in 2 patients. Two patients still had gastrostomy tube due to the persistent symptoms. Two patients had improved after surgery, but died of underlying disease. CONCLUSION : The patients with high vagal palsy are recommended to be managed conservatively for the first 2 months. If aspiration and dysphagia are persisting after conservative management, vocal cord medialization combined with or without cricopharyngeal myotomy should be considered. If failed, laryngotracheal separation or gastrostomy will be the next option based on the control of the oropharyngeal secretion.

  • PDF

Evaluation of Mechanical Properties for the Compacted Bentonite Buffer Materials (압축 벤토나이트 완충재의 역학 물성 평가)

  • Yoon, Seok;Hong, Chang-Ho;Kim, Taehyun;Kim, Jin-Seop
    • Journal of the Korean Geotechnical Society
    • /
    • v.37 no.10
    • /
    • pp.5-11
    • /
    • 2021
  • The compacted bentonite buffer is one of the most important components in an engineered barrier system (EBS) to dispose of high-level radioactive waste (HLW) produced by nuclear power generation. The compacted bentonite buffer has a crucial role in protecting the disposal canister against the external impact and penetration of groundwater, so it has to satisfy the thermal-hydraulic-mechanical requirements. Even though there have been various researches on the investigation of thermal-hydraulic properties, few studies have been conducted to evaluate mechanical properties for the compacted bentonite buffer. For this reason, this paper conducted a series of unconfined compression tests and obtained mechanical properties such as unconfined compressive strength, elastic modulus, and void ratio of Korean compacted bentonite specimens with different water content and dry density values. The unconfined compressive strength and elastic modulus increased, and the Poisson's ratio decreased a little with increasing dry density. It showed that unconfined compressive strength and elastic modulus were proportional to dry density. However, there was not a remarkable correlation between mechanical properties and water content.