• Title/Summary/Keyword: Penetration control

Search Result 622, Processing Time 0.034 seconds

Influence of Painting Materials based on Wasted Oil and Applying Timing on Carbonation and Chloride Resistances of High Volume SCM Concrete (폐유지류를 중심으로 한 도포제 종류 및 도포시기 변화가 혼화재 다량치환 콘크리트의 탄산화 및 염해저항성에 미치는 영향)

  • Han, Cheon-Goo;Choi, Young-Doo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.3 no.3
    • /
    • pp.228-236
    • /
    • 2015
  • In this research, the influence of painting materials and applying timing on carbonation and chloride resistances of high volume SCMs concrete was evaluated. As a durability improving method, comparative tests were conducted with painting materials of ERCO (emulsified refined cooking oil), RCO (refined cooking oil), WR (water repellent agent), and ERCO + WR and with painting timings of right after demolding, and 28 days after the wet curing. From the experiment results, in the case of carbonation and chloride resistance, the carbonation depth and chloride penetration depth were decreased when the painting materials were applied in 28 days of wet curing. Additionally, for painting materials, with the order of ERCO, RCO, ERCO+WR, and WR, the carbonation and chloride penentration was delayed. Hence it is considered that ERCO shows the most favorable performance of resistance against carbonation and chloride penetration.

A Study on Street Types and Application Patterns in High-Rise Apartment Housing - The Case Study of Prizewinners in the Design Competitions since the 1990s - (고층 아파트 단지의 동선 유형 및 적용 패턴에 관한 연구 - '90년대 이후 공영 아파트 설계 경기 당선안을 중심으로 -)

  • Kim, Hyung-Jin;Kim, Young-Suk;Park, Chan-Kyu
    • Journal of the Korean housing association
    • /
    • v.19 no.6
    • /
    • pp.33-44
    • /
    • 2008
  • The street system in multi-family housing is an important design element to control the circulation of vehicles and pedestrians, and to form the spatial organization of the projects. In particular, in the case of high-rise apartments, the street patterns have an influence on the safety, amenity, and convenience of facilities. Until now, however, the design of street patterns in most high-rise multi-family housing projects has diminished the quality of residential environments because priority of design consideration has primarily been given to planning road ways and parking areas. Nevertheless, the design competitions introduced for the first time in the 1980s have played a significant role in developing fresh ideas and concepts in housing design. Because street patterns have been respectably modified as a result of the generalizing of design competitions, it is important to review the ideas that have been proposed in competitions over the recent past. In this context, this study classified the types of street patterns and analyzed their design characteristics for the proposals of housing design competitions since the 1990s. As a result of this analysis, the road patterns are classified into 4 types: 1) serial type, 2) isolated type, 3) mixed type, and 4) not a road pattern due to the system of connection. In addition, these were further divided into 8 types: 1) loop, 2) ring, 3) penetration, 4) tree, 5) direct entry, 6) ring and penetration, 7) loop and penetration, 8) not a road pattern due to appearance and the collector.

THE EFFECT OF THE DENTINE PRETREATMENT ON THE MARGINAL LEAKAGE OF A GLASS IONOMER CEMENT (상아질 표면처리가 글라스 아이오노머 시멘트의 변연누출에 미치는 영향에 관한 연구)

  • Cho, Jung-Hee;Hong, Chan-Ui;Shin, Dong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.1
    • /
    • pp.95-103
    • /
    • 1992
  • The purpose of this study was to evaluate the effect of the dentin pretreatment on the marginal leakage of a glassionomer cement. 1n this study, 60 molars with sound and healthy crown portion were used. The dentin surface of these teeth were exposed and polished with 600 grit silicon carbide paper. Square - shaped cavities were prepared on the flattened dentin surfaces and these were divided into 4 groups according to the dentin pretreatment procedures. Group I : Dentin pretreatment with distilled water as a control group. Group II : Dentin pretreatment with 5% sodium hypochlorite solution. Group III : Dentin pretreatment with Ketac conditioner. Group IV : Dentin pretreatment with 40% polyacrylic acid. The degrees of dye penetration in the cavity walls were assessed using a stereoscope at ${\times}40$ magnification according to the maximum dye penetration. The results were analyzed by using Mann - Whitney U test. The results were as follows : 1. All groups showed varying depth of dye penetration. 2. Distilled water group showed the most severe marginal leakage when compared with the other groups(P<0.05). 3. 40% polyacrylic acid group showed the least amount of marginal leakage compared with the other groups (P<0.05). 4. There were significant differences between Goup I(distilled water) and Group IV (40% polyacrylic acid)(P<0.05), but there were no significant differences among Group I(distilled water), Group II(sodium hypochlorite), Group III(Ketac conditioner) (P>0.05).

  • PDF

Active and Reactive Power Control of ESS in Distribution System for Improvement of Power Smoothing Control

  • Shin, Seong-Su;Oh, Joon-Seok;Jang, Su-Hyeong;Cha, Jae-Hun;Kim, Jae-Eon
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1007-1015
    • /
    • 2017
  • This paper proposes a new control technique of energy storage system (ESS) for smoothing the active power of renewable energy sources (RES) such as photovoltaic and wind turbine generation. As the penetration of RES into grid increases, it is difficult to maintain the permissible level of power quality, that is, voltage and frequency fluctuation in power systems. To solve this problem, ESS control methods using low pass filter (LPF) have been proposed for mitigating the fluctuation of RES output. However, those have a lot of drawbacks which need to be supplemented. Hence, this paper presents the improved active power control with additional reactive power control for maintaining power quality properly. The proposed method minimizes the capacity of ESS to be required for smoothing RES output fluctuation through mitigation of phase delay problem in LPF. In addition, the voltage regulation improves by using additional reactive power control. The proposed method was verified through simulation analysis using PSCAD/EMTDC.

A Study on Early Evaluation Method of Durability of PC Concrete According to the Accelerated Curing Conditions (촉진양생조건에 따른 PC콘크리트의 내구성 조기 평가기법 연구)

  • 김관호;박광수;신수균;이준구;장문기
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.169-174
    • /
    • 2002
  • We can consider that the study on early evaluation of compressive strength and durability of concrete is useful to raise safety of quality control of concrete. In this paper, was proposed to method early to predict strength and durability of concrete with parameter, such as Water/cement(W/C) ratio and steam curing conditions. Through analyzing the relationship between the compressive strength and the amount of chloride penetration into concrete specimens, a new formula early estimating durability of the concrete structure was suggested.

  • PDF

Status and issues of CAD/CAM technology in Korea (국내 CAD/CAM 현황과 문제점)

  • 이종원;김태수
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1986.10a
    • /
    • pp.437-442
    • /
    • 1986
  • Survey has been made to evaluate technological level and to identify research issues in CAD/CAM area. It is found out that major users of the CAD/CAM system are in mechanical and electronics as well as garment industries. Their experience shows that the impact of the CAD/CAM introduction is not yet noticeable in drafting man power and cost reduction. It is identified that the low penetration rate of CAD/CAM technology in industry is due to the lack of locally developed CAD/CAM softwares.

  • PDF

Improvement and Analysis of Chemical Inclination of Municipal Waste Landfill (도시폐기물 매립지반의 개량과 화학적 성향분석)

  • 김영욱;김인규
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.83-88
    • /
    • 1994
  • The DDC(dynamic deep compection) was carried out the main method of ground improvement for construction of municipal high way. The project area is composed of the municipal waste dumped, demolished building debris, coal ash and industrial waste made between 1983 and 1989. From the result of fileld measurement, it was found that waste landfill was compressed considerably (15 ~ 20% of full depth), and the strength was increased satisfactorily(20 ~ 120% of original N-value, 55 ~ 230% of original dynamic cone penetration resistance). And the chemical inclination of the municipal waste landfill was analyzed for expection and control of settlement.

  • PDF

Defending Against Today's Advanced Persistent Threats (최신 APT 해킹공격에 대한 방어)

  • Marpaung, Jonathan A.P.;Lee, HoonJae
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2012.11a
    • /
    • pp.954-957
    • /
    • 2012
  • Recent high profile attacks have brought the attention of governments, corporations, and the general public towards the dangers posed by Advanced Persistent Threats. This paper provides an analysis of the attack vectors employed by these actors by studying several recent attacks. We present recommendations on how to best defend against these threats by better classification of critical information infrastructure and assets, people protection, penetration tests, access control, security monitoring, and patch management.

Research on Voltage Stability Boundary under Different Reactive Power Control Mode of DFIG Wind Power Plant

  • Ma, Rui;Qin, Zeyu;Yang, Wencan;Li, Mo
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1571-1581
    • /
    • 2016
  • A novel method is proposed to construct the voltage stability boundary of power system considering different Reactive Power Control Mode (RPCM) of Doubly-Fed Induction Generator (DFIG) Wind Power Plant (WPP). It can be used for reflecting the static stability status of grid operation with wind power penetration. The analytical derivation work of boundary search method can expound the mechanism and parameters relationship of different WPP RPCMs. In order to improve the load margin and find a practical method to assess the voltage security of power system, the approximate method of constructing voltage stability boundary and the critical points search algorithms under different RPCMs of DFIG WPP are explored, which can provide direct and effective reference data for operators.

Development of Automatic Filet Welding Torch System with High Speed Rotating Arc Sensor

  • Lee, W.K.;Lee, G.Y.;Kim, J.H.;Kim, S.B.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.94.1-94
    • /
    • 2001
  • Arc sensor gives important groove information during welding. Automatic seam tracking control system with arc sensor has significant characteristics such that bead formation is given as decentralization of penetration and formation of concave bead profile and that a turning point of transverse weaving with constant arc length control is decided whether or not torch height reaches to a specified setting level. Furthermore, the rotating action of the arc prevents hanging of weld bead and forms flat bead surface under high speed welding condition. The variation of groove and deposition area can be detected from the trace of weaving. The area and width of weaving trace has close correlation with the area of groove and deposition. In this paper, main object of this system is to realize an adaptive microprocessor based controller ...

  • PDF