• 제목/요약/키워드: Peak torque

검색결과 260건 처리시간 0.029초

Tight sportswear and physiological function - Effect on muscle strength and EMG activity -

  • Dai, Xiao-Qun;Li, Yu-Ping;Cai, Juan-Juan;Lu, A-Ming;Wang, Guo-Dong
    • 복식문화연구
    • /
    • 제21권4호
    • /
    • pp.606-611
    • /
    • 2013
  • It has been reported that tight sportswear could have complicated influence on physiological function of human body. The purpose of this present study was to investigate the effect of wearing gradient compression tights (GCT) on muscle strength and EMG activity during repeated isokinetic muscle contractions. Four healthy male undergraduate students performed maximal voluntary isokinetic concentric muscle contractions on biomechanical test and training systems with GCT and loose pants as control (Cont) respectively. During each test, the peak torque of extensor and flexor contractions and the surface electromyography (sEMG) of the rectus femoris and medial gastrocnemius was recorded simultaneously, the peak torque was recorded as an indicator of muscle strength, and the average amplitude and mean power frequency of sEMG were calculated as indicators of EMG activity. The results showed that: the peak torque decreased gradually during continuous muscle contractions both when the Cont and GCT were worn, average sEMG and mean power frequency declined along with the repetitions of muscle contractions for both wearing conditions, and the change tendency was consistence with that of peak torque. There was no obvious difference between the peak torque recorded wearing the Cont or wearing GCT, but when GCT were worn, average sEMG was lower and mean power frequency was higher than the Cont condition. In 24 samples obtained from four subjects, 80% of results showed the same trend. So we could make a conclusion that wearing GCT had no obvious effect on the improvement of muscle strength, but it would affect the EMG activity positivly.

복합운동처치가 태권도 선수의 슬관절 등속성 근 기능에 미치는 영향 (The Effect of Combined Exercise Training to Knee Joint Isokinetic Muscular Function in the Taekwondo Athlete)

  • 최경석
    • 생명과학회지
    • /
    • 제18권1호
    • /
    • pp.30-37
    • /
    • 2008
  • 본 연구에서는 남자 고등부 태권도 선수들을 대상으로 하여 등장성운동과 등척성 등장성운동을 혼합하여 복합 훈련을 실시한 차이를 알아보기 위하여 등속성 근 기능 중 최대우력, 동측근력비율, 양측근력비율, 근지구력을 분석한 결과를 다음과 같은 결론으로 나타내었다. 첫째, 최대우력은 좌우측 신굴근 모두에서 등장성 운동집단에 비하여 복합 훈련집단이 유의하게 증가한 것으로 나타났다. 둘째, 동측근력비율, 근지구력은 두 집단 간에 유의한 차이는 나타나지 않았지만, 운동전후에 차이에 있어서는 두 집단 모두 유의하게 증가하였다. 셋째, 양측근력비율은 두 집단 간에 유의한 차이는 나타나지 않았지만, 운동전후에 차이에 있어서는 두 집단 모두 유의하게 감소하였다. 이러한 결과로서 태권도 선수들의 경기력 증가를 위한 주요 체력요소인 평형능력, 근 지구력의 향상을 위한 방법으로 등장성 운동과 복합훈련 중 어떠한 방법으로 실시하여도 근 기능을 향상 시킬 수 있는 운동법으로 생각된다. 그러나 등척성 운동과 등장성 운동을 복합적으로 실시하였을 경우 최대우력이 등장성운동을 실시한 집단에 비하여 유의하게 증가하는 현상으로 보면 태권도 발차기의 파워를 보다 증가시키기 위해서는 등장성 운동과 등척성을 복합적으로 실시하는 운동방법이 보다 효과적인 방법으로 생각된다.

슬괵근의 길이 변화에 따른 근력 평가에 관한 연구 (A Study on the Evaluation of the Muscle Strength according to the Change of the Hamstring Muscle Length)

  • 최재청
    • The Journal of Korean Physical Therapy
    • /
    • 제11권2호
    • /
    • pp.1-4
    • /
    • 1999
  • The purpose of this study was to analyze the changes of the muscle strength and length according to the changes of evaluation postures. Subjects of this study were 13 male and 13 female students. 6 evaluation postures were selected for this study(K90H90, K90H45, K90H0, K70H90, K70H45, K70H0 ; K90=knee $90^{\circ}$ flexion, K70=knee $70^{\circ}$ flexion, H90=hip $90^{\circ}$ fleion, H45=hip $45\circ}$ flexion. H0=hip $0^{\circ}$ ). The peak torque and hamstring muscle length(from fibula head to ischial tuberosity) were measured at each postures. The peak torque level was evaluated by make use of the KIN-COM. The results were as follows : 1. The peak torque in male was significantly increased with changes of hip flexion angle but not in female(($90^{\circ}\;>\;45^{\circ}\;>0^{\circ}$). 2. The hamstring length and peat torque in male and female was significantly changed according to the alteration of evaluation postures.

  • PDF

Wind loads on a solar array

  • Kopp, G.A.;Surry, D.;Chen, K.
    • Wind and Structures
    • /
    • 제5권5호
    • /
    • pp.393-406
    • /
    • 2002
  • Aerodynamic pressures and forces were measured on a model of a solar panel containing six slender, parallel modules. Of particular importance to system design is the aerodynamically induced torque. The peak system torque was generally observed to occur at approach wind angles near the diagonals of the panel ($45^{\circ}$, $135^{\circ}$, $225^{\circ}$ and $315^{\circ}$) although large loads also occurred at $270^{\circ}$, where wind is in the plane of the panel, perpendicular to the individual modules. In this case, there was strong vortex shedding from the in-line modules, due to the observation that the module spacing was near the critical value for wake buffeting. The largest loads, however, occurred at a wind angle where there was limited vortex shedding ($330^{\circ}$). In this case, the bulk of the fluctuating torque came from turbulent velocity fluctuations, which acted in a quasi-steady sense, in the oncoming flow. A simple, quasi-steady, model for determining the peak system torque coefficient was developed.

시·촉각 되먹임이 넙다리네갈래근 등척성 운동에 미치는 영향 (The Effects of Visual and Tactile Feedback on Quadriceps Isometric Exercise)

  • 이수영;정영종
    • 한국전문물리치료학회지
    • /
    • 제8권3호
    • /
    • pp.27-34
    • /
    • 2001
  • Physical therapists have been using biofeedback training to induce improvements in various circumstances. The purpose of this study was to compare the effects of visual and tactile feedback using electrical stimulation on quadriceps strength. Nineteen women without known impairment of the neuromusculoskeletal system volunteered for this study. Subjects were randomly allocated into three groups: visual feedback, tactile feedback, and control group. The torque of isometric knee extension force was measured. Subjects were asked to exert the maximal isometric contraction force of quadriceps over a 30 second period. The resting period of 10 minutes was given after the maximal isometric contraction to avoid the muscle fatigue. In between groups comparison, significant differences of the peak torque and the torque area were found on the performance of the maximal isometric contraction of quadriceps (p<.05). The values peak of torque and torque area were significantly higher during visual feedback than tactile feedback. The results of this study suggest that visual feedback is more powerful than tactile feedback (p<.01).

  • PDF

Comparison between Isokinetic Peak Torque and Isotonic 1RM on the Knee Joint

  • Jaehyun Yoo
    • Physical Therapy Rehabilitation Science
    • /
    • 제12권2호
    • /
    • pp.201-205
    • /
    • 2023
  • Objective: Resistance exercise is a necessary element to improve quality of life, and measurement and evaluation of muscle strength provide important information for prescription and management of rehabilitation and exercise programs. This study analyzed the correlation between direct and indirect 1RM for isokinetic maximum torque of the knee joint in order to provide useful information in the field of exercise programs. In addition, the flexion-extension ratio and the difference in left-right deviation were verified. Design: A cross-sectional study Methods: The subjects of this study were 33 healthy adult men and women without medical problems who participated in the health exercise class program at S University in Seoul. The correlation between isokinetic maximum torque and direct and indirect 1RM was analyzed, and a dependent t-test was performed to analyze the flexion-extension ratio and left-right deviation. Results: There was a high correlation between the isokinetic maximum torque and direct and indirect 1RM, and no statistically significant difference was shown between the test methods in the analysis of the flexion-extension ratio and left-right deviation. Conclusions: Isokinetic muscle function measuring equipment is expensive, so it is difficult to use it in local exercise rehabilitation and training sites. Through this study, it was found that direct and indirect 1RM isokinetic maximum torque showed a high correlation, and there was no difference in evaluating muscle function such as flexion-extension ratio and left-right deviation. Therefore, it is considered that the muscle function evaluation using 1RM in general field can be usefully utilized.

뜸 시술에 의한 대퇴부 근피로 회복 평가 (Evaluation of the Muscle Fatigue Recovery Effect by Indirect Moxibustion Treatment)

  • 이승욱;김정윤;이나라;김영호;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제28권4호
    • /
    • pp.59-66
    • /
    • 2011
  • Objectives : This study is aimed to evaluate and objectify the therapeutic effect of moxibustion on muscle fatigue recovery. Methods : To evaluate the therapeutic effect on the muscle fatigue recovery, we compared the fatigue recovery of two groups (non-stimulation group and moxibustion group) by analyzing the EMG and peak torque after strenuous knee exercise of isokinetic contraction. Results : The median frequency (MF) of the moxibustion group was recovered faster than that of the non-stimulation group. However, the peak torques of both groups were not restored until after 20 minutes. Nevertheless, the moxibustion group's peak torque was regained higher than that of the non-stimulation group. Conclusions : We confirmed the therapeutic effect of moxibustion and found that the moxibustion can used as prevention method for musculoskeletal disease.

Yield displacement profiles of asymmetric structures for optimum torsional response

  • Georgoussis, George K.
    • Structural Engineering and Mechanics
    • /
    • 제45권2호
    • /
    • pp.233-257
    • /
    • 2013
  • Given the yield shear of a single-story inelastic structure with simple eccentricity, the problem of strength distribution among the resisting elements is investigated, with respect to minimize its torsional response during a ground motion. Making the hypothesis that the peak accelerations, of both modes of vibration, are determined from the inelastic acceleration spectrum, and assuming further that a peak response quantity is obtained by an appropriate combination rule (square root of sum of squares-SRSS or complete quadratic combination-CQC), the first aim of this study is to present an interaction relationship between the yield shear and the maximum torque that may be developed in such systems. It is shown that this torque may be developed, with equal probability, in both directions (clockwise and anticlockwise), but as it is not concurrent with the yield shear, a rational design should be based on a combination of the yield shear with a fraction of the peak torque. The second aim is to examine the response of such model structures under characteristic ground motions. These models provide a rather small peak rotation and code provisions that are based on such principles (NBCC-1995, UBC-1994, EAK-2000, NZS-1992) are superiors to EC8 (1993) and to systems with a stiffness proportional strength distribution.

The combined effect of dismantling for steam sterilization and aging on the accuracy of spring-style mechanical torque devices

  • Mahshid, Minoo;Saboury, Aboulfazl;Sadr, Seyed Jalil;Fayyaz, Ali;Kadkhodazadeh, Mahdi
    • Journal of Periodontal and Implant Science
    • /
    • 제43권5호
    • /
    • pp.221-226
    • /
    • 2013
  • Purpose: This study aimed to assess the combined effect of dismantling before sterilization and aging on the accuracy (${\pm}10%$ of the target torque) of spring-style mechanical torque devices (S-S MTDs). Methods: Twenty new S-SMTDs from two different manufacturers (Nobel Biocare and Straumann: 10 of each type) were selected and divided into two groups, namely, case (group A) and control (group B). For sterilization, 100 cycles of autoclaving were performed in 100 sequences. In each sequence, 10 repetitions of peak torque values were registered for aging. To measure and assess the output of each device, a Tohnichi torque gauge was used (P<0.05). Results: Before steam sterilization, all of the tested devices stayed within 10% of their target values. After 100 cycles of steam sterilization and aging with or without dismantling of the devices, the Nobel Biocare devices stayed within 10% of their target torque. In the Straumann devices, despite the significant difference between the peak torque and target torque values, the absolute error values stayed within 10% of their target torque. Conclusion: Within the limitations of this study, there was no significant difference between the mean and absolute value of error between Nobel Biocare and Straumann S-S MTDs.

The Effects of Different Angles of Wedged Insoles on Knee Varus Torque in Healthy Subjects

  • Jung, Do-Young;Kwon, Oh-Yun;Yi, Chung-Hwi;Kim, Young-Ho;Kim, Jang-Hwan
    • 한국전문물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.31-41
    • /
    • 2004
  • The purpose of this study was to examine the effect of the angle of a wedged insole on knee varus torque during walking. Fifteen healthy subjects were recruited. Knee varus torque was measured using three-dimensional motion analysis (Elite). Knee varus torque was normalized to gait cycle (0%: initial contact; 100%: ipsilateral initial contact) and stance phase (0%: initial contact; 100%: ipsilateral toe off). The average peaks of knee varus torque during the stance phase of the gait cycle according to the different insole angles (10 or 15 degrees) were compared using one-way ANOVA with repeated measures. The results showed that in the early stance phase, the average peak knee varus torque increased significantly for both the medial 10 and 15 degree wedged insole conditions and decreased significantly for both the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p<.05). However, there were no significant differences between the 10 and 15 degree wedged insole conditions with either the medial or lateral wedged insole (p>.05). In the late stance phase, the average peak knee varus torque increased significantly for the medial 10 and 15 degree wedged insole conditions (p<.05), but not for the lateral 10 and 15 degree wedged insole conditions as compared with no insole (p>.05). We suggest that these results may be beneficial for manufacturing foot orthotic devices, such as wedged insoles, to control medial and lateral compartment forces in the knee varus-valgus deformity. Further studies of the effects of wedged insole angle on knee varus torque in patients with medial-lateral knee osteoarthritis are needed.

  • PDF