• Title/Summary/Keyword: Peak pressure

Search Result 1,458, Processing Time 0.029 seconds

Dynamic response of a lined tunnel with transmitting boundaries

  • Fattah, Mohammed Y.;Hamoo, Mohammed J.;Dawood, Shatha H.
    • Earthquakes and Structures
    • /
    • v.8 no.1
    • /
    • pp.275-304
    • /
    • 2015
  • The objective of this paper is to investigate the validity of transmitting boundaries in dynamic analysis of soil-structure interaction problems. As a case study, the proposed Baghdad metro line is considered. The information about the dimensions and the material properties of the concrete tunnel and surrounding soil were obtained from a previous study. A parametric study is carried out to investigate the effect of several parameters including the peak value of the horizontal component of earthquake displacement records and the frequency of the dynamic load. The computer program (Mod-MIXDYN) is used for the analysis. The numerical results are analyzed for three conditions; finite boundaries (traditional boundaries), infinite boundaries modelled by infinite elements (5-node mapped infinite element) presented by Selvadurai and Karpurapu, 1988), and infinite boundaries modelled by dashpot elements (viscous boundaries). It was found that the transmitting boundary absorbs most of the incident energy. The distinct reflections observed for the "fixed boundaries" disappear by using "transmitted boundaries". This is true for both cases of using viscous boundaries or mapped infinite elements. The type and location of the dynamic load represent two controlling factors in deciding the importance of using infinite boundaries. It was found that the results present significant differences when earthquake is applied as a base motion or a pressure load is applied at the surface ground. The peak value of the vertical displacement at nodes A, B, E and F (located at the tunnel's crown and side walls, and at the surface above the tunnel and at the surface 6.5 m away from tunnel's centre respectively) increases with the frequency of the surface pressure load for both cases 1 and 2 (traditional boundaries and mapped infinite elements respectively) while it decreases for case 3 (viscous boundaries). The modular ratio Ec/Es (modulus of elasticity of the concrete lining to that of the surrounding soil) has a considerable effect on the peak value of the horizontal displacement at node B (on the side wall of the tunnel lining) increase about (17.5) times, for the three cases (1, 2, and 3).

Spatial correlation of aerodynamic forces on 5:1 rectangular cylinder in different VIV stages

  • Lei, Yongfu;Sun, Yanguo;Zhang, Tianyi;Yang, Xiongwei;Li, Mingshui
    • Wind and Structures
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2022
  • To better understand the vortex-induced vibration (VIV) characteristics of a 5:1 rectangular cylinder, the distribution of aerodynamic force and the non-dimensional power spectral density (PSD) of fluctuating pressure on the side surface were studied in different VIV development stages, and their differences in the stationary state and vibration stages were analyzed. The spanwise and streamwise correlations of surface pressures were studied, and the flow field structure partitions on the side surface were defined based on the streamwise correlation analysis. The results show that the variation tendencies of mean and root mean square (RMS) pressure coefficients are similar in different VIV development stages. The RMS values during amplitude growth are larger than those at peak amplitude, and the smallest RMS values are observed in the stationary state. The spanwise correlation coefficients of aerodynamic lifts increase with increase of the peak amplitude. However, for the lock-in region, the maximum spanwise correlation coefficient for aerodynamic lifts occurs in the VIV rising stage rather than in the peak amplitude stage, probably due to the interaction of vortex shedding force (VSF) and self-excited force (SEF). The streamwise correlation results show that the demarcation point positions between the recirculation region and the main vortex region remain almost constant in different VIV development stages, and the reattachment points gradually move to the tailing edge with increasing amplitude. This study provides a reference to estimate the demarcation point and reattachment point positions through streamwise correlation and phase angle analysis from wind tunnel tests.

Prediction of Tensile Strength of Wet Sand (I) : Theory (습윤 모래에서 인장강도의 예측 (I) : 이론)

  • Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.6
    • /
    • pp.27-35
    • /
    • 2008
  • At low normal stress levels tensile strength of sand varies with either saturation or suction of soil in an up-and-down manner with a peak tensile strength that can occur at any degree of saturation. A theory that accurately predicts tensile strength of wet sand is presented. A closed form expression for tensile strength unifies tensile strength characteristics in all three water retention regimes: pendular, funicular, and capillary. Three parameters are employed in the theory; namely, the Internal friction angle (at low normal stress) ${\phi}_t$, the inverse value of the air-entry pressure ${\alpha}$, and the pore size spectrum parameter n. It is shown that the magnitude of peak tensile strength is dominantly controlled by the ${\alpha}$ parameter. The saturation at which peak tensile strength occurs only depends on the pore size spectrum parameter n.

Impact of Pulmonary Arterial Elastance on Right Ventricular Mechanics and Exercise Capacity in Repaired Tetralogy of Fallot

  • Soo-Jin Kim;Mei Hua Li;Chung Il Noh;Seong-Ho Kim;Chang-Ha Lee;Ja-Kyoung Yoon
    • Korean Circulation Journal
    • /
    • v.53 no.6
    • /
    • pp.406-417
    • /
    • 2023
  • Background and Objectives: Pathophysiological changes of right ventricle (RV) after repair of tetralogy of Fallot (TOF) are coupled with a highly compliant low-pressure pulmonary artery (PA) system. This study aimed to determine whether pulmonary vascular function was associated with RV parameters and exercise capacity, and its impact on RV remodeling after pulmonary valve replacement. Methods: In a total of 48 patients over 18 years of age with repaired TOF, pulmonary arterial elastance (Ea), RV volume data, and RV-PA coupling ratio were calculated and analyzed in relation to exercise capacity. Results: Patients with a low Ea showed a more severe pulmonary regurgitation volume index, greater RV end-diastolic volume index, and greater effective RV stroke volume (p=0.039, p=0.013, and p=0.011, respectively). Patients with a high Ea had lower exercise capacity than those with a low Ea (peak oxygen consumption [peak VO2] rate: 25.8±7.7 vs. 34.3±5.5 mL/kg/min, respectively, p=0.003), while peak VO2 was inversely correlated with Ea and mean PA pressure (p=0.004 and p=0.004, respectively). In the univariate analysis, a higher preoperative RV end-diastolic volume index and RV end-systolic volume index, left ventricular end-systolic volume index, and higher RV-PA coupling ratio were risk factors for suboptimal outcomes. Preoperative RV volume and RV-PA coupling ratio reflecting the adaptive PA system response are important factors in optimal postoperative results. Conclusions: We found that PA vascular dysfunction, presenting as elevated Ea in TOF, may contribute to exercise intolerance. However, Ea was inversely correlated with pulmonary regurgitation (PR) severity, which may prevent PR, RV dilatation, and left ventricular dilatation in the absence of significant pulmonary stenosis.

The Peak Systolic Pressure-End Systolic Volume Index Relation in Patients with Coronary Artery Disease Using Radionuclide Gated Blood Pool Scintigraphy (관상동맥질환에서 심장풀스캔을 이용한 최고수축기혈압-수측기말용적곡선의 분석)

  • Kim, Byung-Tae;Koong, Sung-Soo;Bom, Hee-Seung;Chung, June-Key;Park, Young-Bae;Lee, Myung-Chul;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.175-182
    • /
    • 1987
  • For measurement of ventricular performance, ejection fraction (EF) has gained wide acceptance. But EF is influenced not only by changes in muscle function but also by changes in cardiac loading conditions. In case of valvular heart disease which is variable in loading conditions, EF cannot be reliable as an index of myocardial contractility. The end systolic pressure (ESP)-end systolic volume (ESV) relation, howver, is known to represent myocardial contractility, independent of changes in loading conditions. Similar results can be obtained by using peak-systolic pressure (PSP) instead of ESP. To evaluate the utility of the peak systolic pressure-end systolic volume index (PSP-ESVI) relation as an index of myocardial function, we measured $PSP&ESVI$ in 19 partents with coronary artery disease before $(PSP_1\;&\;ESVI_1)$ and after $(PSP_2\;&\;ESVI_2)$ sublingual administration of nitroglycerin. PSP was measured with standard mercury sphygmomanometer during gated blood pool scintigraphic study. ESVI was measured by count derived method after attenuation correction. $PSP_2\;&\;ESVI_2$ measurement was started when the fall of PSP was greater than 5 mmHg after 7-14 minutes post-administration of nitroglycerin. Mean values $({\pm}S.D.)$ of $PSP_1\;&\;ESVI_1$ was $124.9({\pm}20.7)mmHg\;&\;59.4({\pm}39.9)ml/M^2$. Mean values $({\pm}S.D)$ of $PSP_2\;&\;ESVI_2$, was $113.2({\pm}19.9)mmHg\;&\;37.5({\pm}26.1)ml/M^2$. There was a significant difference between mean values of $PSP_1\;&\;PSP_2$, (p<0.01), and mean values of $ESVI_1\;&\;ESVI_2$, (p<0.01). $PSP_1-PSP_2/ESV_1-ESVI_2,\;PSP_1/ESVI_1$ and EF were in the range of 0.14-5.19 mmHg/ml/$M^2$, 0.67-7.68 mmHg/ml/$M^2$ and 10.8%-74.5% respectively. $PSP_1-PSP_2/ESVI_1-ESVI_2$, and EF showed exponential correlation (r=0.85, P<0.01). The correlation coefficient between $PSP_1/ESVI_1$ and EF was 0.73(p<0.01). With the above results, we suggest that $PSP_1-PSP_2/ESVI_1-ESVI_2$, and $PSP_1/ESVI_1$, can be used as an index of myocardial function.

  • PDF

Synoptic Weather Patterns and Variation of Ozone Concentrations Association with High Ozone Days at Five Major Cities in Korea (고농도 오존이 발생하는 날의 종관 기상 패턴과 주요 5대 도시별 오존 농도 변화)

  • 김유라;윤일희;김희종
    • Journal of Environmental Science International
    • /
    • v.10 no.6
    • /
    • pp.437-444
    • /
    • 2001
  • The characteristic features of surface ozone concentration and the forecasting procedure of high ozone days have been studied. The ozone concentration was continuously measured during 3 years (1997~1999) at air quality monitoring stations in five major cities in Korea. The diurnal variation of surface ozone concentration on high ozone days is characterized by low ozone concentration at night. The ozone concentration Increases continuously after sunrise, In reach a peak at 1500~1600 LST. Thereafter it decreases steadily to a low concentration at sunset. The diurnal and annual maximum of the surface ozone concentration at Seoul were observed in May and June, respectively. The favorable synoptic condition for the high ozone day is divided into 4 different synoptic weather patterns: a high-pressure system from the Sea of Okhotsk, the Pacific subtropical high extending westward, a moving high-pressure system covering the Korean peninsula. and a synoptic system In front of a typhoon. Most of high ozone days occur under the high pressure system in Korea.

  • PDF

Flow-Induced Vibration Signal Analysis of the FIV Test Loop (FIV 시험루프의 유동기인 진동 신호분석)

  • Lee, Kang-Hee;Kang, Heung-Soek;Yoon, Kyung-Ho;Song, Kee-Nam
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.601-606
    • /
    • 2004
  • Vibration spectrums of the test loop according to flow conditions were analyzed in order to identify the sources of vibration at peak frequencies. While a flow condition of the sweep test was changed by varying pump rotational speed from 450 rpm to 1500 rpm by the step 150 rpm, midspan acceleration of the test section in width-direction and dynamic pressure perturbation in the test section were measured. Other sources of vibration due to the flow structure interactions, such as acoustic resonance, blade pulsing frequency and bellows wrinkles, were investigated. Pressure perturbation in the section and acoustic resonance due to branch pipe give major effects to the vibration of the test section in high frequency range of 1.5 kHz to 2.8 kHz.

  • PDF

Hemodynamic studies early after open heart surgery: comparison of repair of ventricular septal defect and mitral valvular reconstruction (개심술후 조기 혈행동태심실중격결손증 교정과 승모판재건술에 대한 비교)

  • 문병탁
    • Journal of Chest Surgery
    • /
    • v.17 no.1
    • /
    • pp.59-66
    • /
    • 1984
  • After open heart surgery, the patient must be carefully observed and adequately managed for his survival. This report reviewed 10 cases of ventricular septal defect and 12 mitral valvular diseases as hemodynamics early after open heart surgery. For postoperative 24 hours, clinical status was evaluated for left atrial pressure, central venous pressure,DP[LAP-CVP], peak systolic pressure, heart rate, urine amount, and other clinical findings. Especially, on postoperative fourth hour, cardiac output was most decreased, when the changes of monitoring were compared with two groups with or without using cardiotonics. Finally, we concluded as followings; 1.Postoperatively, variation of CVP was noted in VSD, but mitral valvular disease was more variable change of LAP. 2.DP was 1.3\ulcorner.4 cmH2O in VSD, and 6.4\ulcorner.2 cmH2O in mitral valvular disease. 3.Parameter using cardiotonic was CVP in VSD, and LAP in mitral valvular disease.

  • PDF

A Study on the Dynamic Behaviors of Engine Bearing with the Consideration of Elastic Deformation in the Con-Rod System (탄성변형을 고려한 엔진베어링의 동적 거동에 대한 연구)

  • Jang Siyoul;Park Gaemin
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.275-282
    • /
    • 2004
  • The engine bearing transmits the powers from cylinder to crankshaft with small clearance between con-rod and crankpin. The minimum oil film thickness is a significant parameter in the operation of bearing. The contact pressure of bearing should be considered for the reason that elastic deformation of bearing be caused by contact pressure of bearing. There are important factors which are maintaining of minimum oil film thickness expecting of the length of maximum and minimum oil film thickness with changing of the loads to keep running normally. Furthermore, this study is very crucial to develop the design of engine bearing and crankshaft system.

  • PDF

Proposal of pulse parameter useful for pulse wave analysis in oriental medicine: Preliminary study on floating and sinking pulses (통계분석을 통한 한의 맥진에 유용한 파라미터 도출: 부침맥을 중심으로 한 예비연구)

  • Lee, Jeon;Lee, Yu-Jung;Lee, Hae-Jung;Choi, Eun-Ji;Kim, Jong-Yeol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.244-246
    • /
    • 2006
  • In this study, we search some parameters well-related to floating-sinking pulse by statistical analysis, because these pulses are frequently used in clinic. Pulse signals were acquired by 3D pulse analyzer and 30 subjects consist of 15 people diagnosed as floating pulse and 15 people diagnosed as sinking pulse by oriental doctors who have over 5 years clinical experience. Then, we made a representative beat template for each subject and, through a peak detection algorithm, we calculated several pulse parameters. To find the parameters related to floating-sinking pulse, we performed statistical testing with 17 parameters through the independence sampling, t-test. As a result, there is the biggest difference between pressure, the maximum pulse pressure, diastolic area(Ad) and float-sink data. (p < .05).

  • PDF