• 제목/요약/키워드: Peak detection algorithm

검색결과 191건 처리시간 0.036초

낮은 샘플링 주파수를 가지는 심전도 신호를 이용한 심박 간격 추정 알고리즘 (Heart Beat Interval Estimation Algorithm for Low Sampling Frequency Electrocardiogram Signal)

  • 최병훈
    • 전기학회논문지
    • /
    • 제67권7호
    • /
    • pp.898-902
    • /
    • 2018
  • A novel heart beat interval estimation algorithm is presented based on parabola approximation method. This paper presented a two-step processing scheme; a first stage is finding R-peak in the Electrocardiogram (ECG) by Shannon energy envelope estimator and a secondary stage is computing the interpolated peak location by parabola approximation. Experimental results show that the proposed algorithm performs better than with the previous method using low sampled ECG signals.

신생아를 대상으로한 청성뇌간유발반응의 자동 판독 알고리즘 (Algorithm of an automated auditory brainstem response neonatal hearing screening method)

  • 정원혁;홍현기;김성우;김진태;박중훈;김덕원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2006년도 하계종합학술대회
    • /
    • pp.825-826
    • /
    • 2006
  • In this paper, we propose an algorithm that applies Rolle's theorem to automatically detect and label peak III and V of the normal, suprathreshold auditory brainstem response (ABR). ABR waveform were recorded from 55 normal-hearing ears at screening levels varying from 30 to 60 dBnHL. For each ABR waveform, the peak-finding algorithm proceeded in fourth steps: (1) Select maximum and minimum values of the target ABR waveform, (2) divide this range into n equal parts, (3) effective candidate peaks in the ABR waveform are identified using Rolle's theorem (4) peak III and V are identified from these candidate peaks based on their latency and morphology. As a result, proposed auto dectection method showed high correlation and accuracy with manual detection method performed by clinician. By using proposed algorithm, clinician can detect and label peak III and V faster and more efficient than manual detection method.

  • PDF

질량분석기를 위한 스펙트럼 검출 알고리즘의 개선 (Improvement of Spectrum Detection Algorithm for Mass Spectrometer)

  • 이영학;최훈
    • 한국정보통신학회논문지
    • /
    • 제23권1호
    • /
    • pp.47-54
    • /
    • 2019
  • 질량 스펙트럼 분석 시스템을 위한 스펙트럼 검출 알고리즘의 개선 방법을 제안하였다. 질량지수별 이온신호블록에 대한 선형 근사 및 2차 커브피팅의 결과를 활용한 기존의 스펙트럼 검출 알고리즘에서 무효 이온신호 제거조건을 추가 개선함으로써 질량 스펙트럼 검출 시 발생하는 오검출을 개선할 수 있다. 또한 제안한 방법은 피크위치오차가 보정된 유효이온신호블록에 대한 2차 피팅 커브 의 결과를 사용하여 질량 스펙트럼의 피크값 추정오차를 줄일 수 있다. 제안한 방법의 유효성을 보이기 위해 실제 취득한 이온신호를 입력으로 알고리즘 단계별 컴퓨터 시뮬레이션을 수행하였다. 또한 다수의 입력에 대한 오검출 율을 비교함으로써 제안한 방법이 기존 방법에 비해 검출 성능이 우수함을 보였다.

침대 패드 형태의 용량성 전극에서 측정된 심전도 신호를 처리하기 위한 자동 잡음 제거 및 피크 검출 알고리즘 (Automatic Noise Removal and Peak Detection Algorithm for ECG Measured from Capacitively Coupled Electrodes Included within a Cloth Mattress Pad)

  • 이원규;이홍지;윤희남;정기성;박광석
    • 대한의용생체공학회:의공학회지
    • /
    • 제35권4호
    • /
    • pp.87-94
    • /
    • 2014
  • Recent technological advances have increased interest in personal health monitoring. Electrocardiogram(ECG) monitoring is a basic healthcare activity and can provide decisive information regarding cardiovascular system status. In this study, we developed a capacitive ECG measurement system that can be included within a cloth mattress pad. The device permits ECG data to be obtained during sleep by using capacitive electrodes. However, it is difficult to detect R-wave peaks automatically because signals obtained from the system can include a high level of noise from various sources. Because R-peak detection is important in ECG applications, we developed an algorithm that can reduce noise and improve detection accuracy under noisy conditions. Algorithm reliability was evaluated by determining its sensitivity(Se), positive predictivity(+P), and error rate(Er) by using data from the MIT-BIH Polysomnographic Database and from our capacitive ECG system. The results showed that Se = 99.75%, +P = 99.77%, and Er = 0.47% for MIT-BIH Polysomnographic Database while Se = 96.47%, +P = 99.32%, and Er = 4.34% for our capacitive ECG system. Based on those results, we conclude that our R-peak detection method is capable of providing useful ECG information, even under noisy signal conditions.

부정맥 심전도 신호에서 특이 파형 검출 (Unusual Waveform Detection Algorithm in Arrhythmia ECG Signal)

  • 박길흠;김진섭;류춘하;최병재;김정준
    • 한국지능시스템학회논문지
    • /
    • 제23권4호
    • /
    • pp.292-297
    • /
    • 2013
  • 본 논문에서는 불응기(Refractory Period)에 기반한 부정맥 심전도 신호의 특이 파형 검출 알고리즘을 제안한다. 부정맥 심전도 신호는 대부분 평균 10% 정도의 특이 파형을 갖는다. 따라서 장시간 심전도 신호를 관찰 및 분석해야 하는 의료진에게 심전도 신호 샘플의 90%이상이 축소된 특이 파형만을 제공함으로써 시간과 비용 측면에서 매우 큰 효과를 볼 수 있다. 제안 알고리즘은 R-파의 특징과 가변 불응기를 이용하여 R-peak를 검출한다. 검출된 R-peak에 대해 특이 파형에 포함되지 않은 R-peak들의 전위 및 첨도의 평균과 표준편차를 이용하여 특이 파형을 검출한다. 제안한 알고리즘을 MIT-BIH 부정맥 데이터베이스의 모든 레코드에 적용한 결과 평균 90% 이상의 압축률을 보였다.

Sharpness-aware Evaluation Methodology for Haze-removal Processing in Automotive Systems

  • Hwang, Seokha;Lee, Youngjoo
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제5권6호
    • /
    • pp.390-394
    • /
    • 2016
  • This paper presents a new comparison method for haze-removal algorithms in next-generation automotive systems. Compared to previous peak signal-to-noise ratio-based comparisons, which measure similarity, the proposed modulation transfer function-based method checks sharpness to select a more suitable haze-removal algorithm for lane detection. Among the practical filtering schemes used for a haze-removal algorithm, experimental results show that Gaussian filtering effectively preserves the sharpness of road images, enhancing lane detection accuracy.

실시간 QRS 검출을 위한 파라미터 estimation 기법에 관한 연구 (A Study on method development of parameter estimation for real-time QRS detection)

  • 김응석;이정환;윤지영;이명호
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 추계학술대회
    • /
    • pp.193-196
    • /
    • 1995
  • An algorithm using topological mapping has been developed for a real-time detection of the QRS complexes of ECG signals. As a measurement of QRS complex energy, we used topological mapping from one dimensional sampled ECG signals to two dimensional vectors. These vectors are reconstructed with the sampled ECG signals and the delayed ones. In this method, the detection rates of CRS complex vary with the parameters such as R-R interval average and peak detection threshold coefficient. We use mean, median, and iterative method to determint R-R interval average and peak estimation. We experiment on various value of search back coefficient and peak detection threshold coefficient to find optimal rule.

  • PDF

ECG 진단을 위한 QRS 검출 알고리즘 (QRS Detection Algorithm for ECG Analysis)

  • 홍성호;김영섭;이명석;노학엽;지용석
    • 반도체디스플레이기술학회지
    • /
    • 제11권3호
    • /
    • pp.57-61
    • /
    • 2012
  • In order to analyze the ECG, it is important to pinpoint the repeat interval of the ECG. In this paper, we present an efficient algorithm for finding the QRS complex on the ECG. We escaped from the conventional methods to go through multiple steps of preprocessing to make ECG easier to find the QRS complex. We selected the candidate peak that has the possibility of the QRS complex in original ECG, and used technique to find the QRS complex among the candidate peak. In this way, we could get similar efficiency to Pan & Tompkins Algorithm that is most representative QRS complex detection algorithm, just used fewer operations than Pan & Tompkins Algorithm.

Efficient Key Detection Method in the Correlation Electromagnetic Analysis Using Peak Selection Algorithm

  • Kang, You-Sung;Choi, Doo-Ho;Chung, Byung-Ho;Cho, Hyun-Sook;Han, Dong-Guk
    • Journal of Communications and Networks
    • /
    • 제11권6호
    • /
    • pp.556-563
    • /
    • 2009
  • A side channel analysis is a very efficient attack against small devices such as smart cards and wireless sensor nodes. In this paper, we propose an efficient key detection method using a peak selection algorithm in order to find the advanced encryption standard secret key from electromagnetic signals. The proposed method is applied to a correlation electromagnetic analysis (CEMA) attack against a wireless sensor node. Our approach results in increase in the correlation coefficient in comparison with the general CEMA. The experimental results show that the proposed method can efficiently and reliably uncover the entire 128-bit key with a small number of traces, whereas some extant methods can reveal only partial subkeys by using a large number of traces in the same conditions.

SOA를 광원으로 사용하는 광섬유 센서 어레이의 출력 안정화 (Stabilization of optical fiber sensor array using a semiconductor optical amplifier source)

  • 박형준;김현진;송민호
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2008
  • We developed a fiber-optic Bragg grating sensor system using a SOA fiber laser for over heat detection in power systems. To compensate the nonlinear wavelength tuning of the fiber laser, we used fixed passband wavelengths from Fabry-Perot ITU filter as reference wavelengths. Gaussian line-fitting algorithm was also used to reduce the FBG peak detection error. Compared with a highest-peak-detection and a polynomial-fitting method, the proposed Gaussian fitting algorithm could drastically reduce the measurement errors. Also the SOA fiber laser made it possible to enhance the signal-to-noise-ratio even with several kilometers of lead fiber.

  • PDF