• Title/Summary/Keyword: Peak cladding temperature

Search Result 42, Processing Time 0.019 seconds

Analysis of LOFT LP-02-6 Experiment Using RELAP5/MOD3.2

  • Park, Tong-Soo;Lee, Jae-Hoon;Park, Byung-Suh;Cho, Chang-Sok
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.11a
    • /
    • pp.357-362
    • /
    • 1996
  • LOFT LBLOCA test, LP-02-6 was analyzed using RELAP5/MOD3.2. It has a distinguished thermal-hydraulic phenomenon of a positive bottom-up core flow in tile blowdown phase. A modified nodalization which is based on that used in LP-LB-1 calculation by Lubbesmeyer was used in the calculation. RELAP5/MOD3.2 predicted overall system hydraulic behavior relatively well. However, the bottom-up quenching in the middle part of the core was not predicted sufficiently. It was demonstrated also that the peak cladding temperature can be predicted well by adjusting a discharge coefficient. But more improvements are needed in order to apply this code to actual plants with less user dependency.

  • PDF

고리 1호기 가압열충격 해석을 위란 계통 열수력 해석 연구

  • 김용수;김재학;홍순준;박군철
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.751-756
    • /
    • 1998
  • 고리 1호기 원전 수명 연장을 위한 가압열충격(Pressurized Thermal Shock : PTS) 해석은 확률론적 안전성 평가 방법에 따라 수행된다. 본 연구는 가압열충격 상세 해석 연구의 일환으로 가압열충격 해석을 위한 계통해석시 사용되는 최적 평가(Best Estimate) 방법과 기존의 PCT(Peak Cladding Temperature) 관점의 해석에 사용되는 결정론적 안전성 평가 방법간의 해석 방법론 차이에 의한 열수력 거동의 상이점을 평가하기 위함이다. 이를 위해 1998년 설치 예정인 고리 1호기 교체 증기발생기(Replacement Steam Generator ; RSG) 안전성 분석 보고서$^{[1]}$ 의 주증기관 파단사고 해석 결과와 동일한 파단 크기 및 운전 출력에 대해 최적 평가 방법론에 따라 해석된 본 연구의 해석 결과를 비교, 평가하였다. 해석 결과 전출력 소형 주증기관 파단 사고에서는 터빈 유량 모델링 및 반응도 계수, 고온 영출력 대형 파단 사고에서는 가압기 모델, 반응도 계수 및 정지여유도가 해석 방법론에 따른 열수력 거동의 차이에 영향이 큰 것으로 평가되었다

  • PDF

Multiplexed Hard-Polymer-Clad Fiber Temperature Sensor Using An Optical Time-Domain Reflectometer

  • Lee, Jung-Ryul;Kim, Hyeng-Cheol
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.37-44
    • /
    • 2016
  • Optical fiber temperature sensing systems have incomparable advantages over traditional electrical-cable-based monitoring systems. However, the fiber optic interrogators and sensors have often been rejected as a temperature monitoring technology in real-world industrial applications because of high cost and over-specification. This study proposes a multiplexed fiber optic temperature monitoring sensor system using an economical Optical Time-Domain Reflectometer (OTDR) and Hard-Polymer-Clad Fiber (HPCF). HPCF is a special optical fiber in which a hard polymer cladding made of fluoroacrylate acts as a protective coating for an inner silica core. An OTDR is an optical loss measurement system that provides optical loss and event distance measurement in real time. A temperature sensor array with the five sensor nodes at 10-m interval was economically and quickly made by locally stripping HPCF clad through photo-thermal and photo-chemical processes using a continuous/pulse hybrid-mode laser. The exposed cores created backscattering signals in the OTDR attenuation trace. It was demonstrated that the backscattering peaks were independently sensitive to temperature variation. Since the 1.5-mm-long exposed core showed a 5-m-wide backscattering peak, the OTDR with a spatial resolution of 40 mm allows for making a sensor node at every 5 m for independent multiplexing. The performance of the sensor node included an operating range of up to $120^{\circ}C$, a resolution of $0.59^{\circ}C$, and a temperature sensitivity of $-0.00967dB/^{\circ}C$. Temperature monitoring errors in the environment tests stood at $0.76^{\circ}C$ and $0.36^{\circ}C$ under the temperature variation of the unstrapped fiber region and the vibration of the sensor node. The small sensitivities to the environment and the economic feasibility of the highly multiplexed HPCF temperature monitoring sensor system will be important advantages for use as system-integrated temperature sensors.

Assessment of SCDAP Using the Full-Length High-Temperature FLHT-2 Test (FLHT-2 실험결과를 이용한 SCDAP코드 평가)

  • Park, Choon-Kyung;Park, Jong-Hwa;Yoo, Kun-Jung;Chae, Sung-Ki
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.54-64
    • /
    • 1988
  • This paper assesses the models in the SCDAP code using the results of the FLHT-2 test. Calculations show that the SCDAP correctly predicts Ire temperatures, oxidation front movement, overall hydrogen generation and peak generation rate, internal fuel rod pressure, and cladding rupture due to ballooning. A comparison of the calculated results with measured data shows that two phase level is underpredicted, and that radiation heat transfer and auto-catalytic reaction temperature of zircaloy are overpredicted. These models are recommended to be modified. The analysis also shows that the simulation of the gap in a fuel rod improves the code prediction on core damage progression.

  • PDF

Dynamic Strain Aging of Zircaloy-4 PWR Fuel Cladding in Biaxial Stress State (가압경수로용 지르칼로이-4 피복관의 2축 응력 인장시 동적 변형 시효)

  • Park, Ki-Seong;Lee, Byong-Whi
    • Nuclear Engineering and Technology
    • /
    • v.21 no.2
    • /
    • pp.89-98
    • /
    • 1989
  • The expanding copper mandrel test performed at three strain rates (3.2$\times$10E -5/s, 2.0$\times$10E-6/s and 1.2$\times$10E-7/s) over 553-873 K temperature range by varying the heating rates (8-1$0^{\circ}C$/s, 1-2$^{\circ}C$/s and 0.5$^{\circ}C$/s) in air and in vacuum (5$\times$10E-5 torr). The yield stress peak, the strain rate sensitivity minimum and the activation volume peaks could be explained in terms of the dynamic strain aging. The activation energy for dynamic strain aging obtained from the yield stress peak temperature and strain rate was 196 KJ/mol and this value was in good agreement with the activation energy for oxygen diffusion in $\alpha$-zirconium and Zircaloy-2 (207-220 KJ/mol). Therefore, oxygen atoms are responsible for the dynamic strain aging which appeared between 573 K and 673 K. The yield stress increase due to the oxidation was obtained by comparing the yield stress in air with that in vacuum and represented by the percentage increase of yield stress ( $\sigma$$^{a}$ $_{y}$ - $\sigma$$^{v}$ $_{y}$ / $\sigma$$^{v}$ $_{y}$ ). The slower the strain rate, the greater the percentage increase occurs. In order to estimate the yield stress of PWR fuel cladding material under the service environment, the yield stress in water was obtained by comparing the oxidation rate in air that in water assuming the relationship between the oxygen pick-up amount and the yield stress increase.

  • PDF

Study on the influence of flow blockage in severe accident scenario of CAP1400 reactor

  • Pengcheng Gao;Bin Zhang ;Jishen Li ;Fan Miao ;Shaowei Tang ;Sheng Cao;Hao Yang ;Jianqiang Shan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.999-1008
    • /
    • 2023
  • Deformed fuel rods can cause a partial blockage of the flow area in a subchannel. Such flow blockage will influence the core coolant flow and further the core heat transfer during the reflooding phase and subsequent severe accidents. Nevertheless, most of the system analysis codes simulate the accident process based on the assumed flow blockage ratio, resulting in inconsistencies between simulated results and actual conditions. This paper aims to study the influence of flow blockage in severe accident scenario of the CAP1400 reactor. First, the flow blockage model of ISAA code is improved based on the FRTMB module. Then, the ISAA-FRTMB coupling system is adopted to model and calculate the QUENCH-LOCA-0 experiment. The correctness and validity of the flow blockage model are verified by comparing the peak cladding temperature. Finally, the DVI Line-SBLOCA accident is induced to analyze the influence of flow blockage on subsequent CAP1400 reactor core heat transfer and core degradation. From the results of the DVI Line-SBLOCA accident analysis, it can be concluded that the blockage ratio is in the range of 40%-60%, and the position of severe blockage is the same as that of cladding rupture. The blockage reduces the circulation area of the core coolant, which in turn impacts the heat exchange between the core and the coolant, leading to the early failure and collapse of some core assemblies and accelerating the core degradation process.

IMPROVEMENT OF THE LOCA PSA MODEL USING A BEST-ESTIMATE THERMAL-HYDRAULIC ANALYSIS

  • Lee, Dong Hyun;Lim, Ho-Gon;Yoon, Han Young;Jeong, Jae Jun
    • Nuclear Engineering and Technology
    • /
    • v.46 no.4
    • /
    • pp.541-546
    • /
    • 2014
  • Probabilistic Safety Assessment (PSA) has been widely used to estimate the overall safety of nuclear power plants (NPP) and it provides base information for risk informed application (RIA) and risk informed regulation (RIR). For the effective and correct use of PSA in RIA/RIR related decision making, the risk estimated by a PSA model should be as realistic as possible. In this work, a best-estimate thermal-hydraulic analysis of loss-of-coolant accidents (LOCAs) for the Hanul Nuclear Units 3&4 is first carried out in a systematic way. That is, the behaviors of peak cladding temperature (PCT) were analyzed with various combinations of break sizes, the operating conditions of safety systems, and the operator's action time for aggressive secondary cooling. Thereafter, the results of the thermal-hydraulic analysis have been reflected in the improvement of the PSA model by changing both accident sequences and success criteria of the event trees for the LOCA scenarios.

CFD analysis of the flow blockage in a rectangular fuel assembly of the IAEA 10 MW MTR research reactor

  • Xia, Shuang;Zhou, Xuhua;Hu, Gaojie;Cao, Xiaxin
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2847-2858
    • /
    • 2021
  • When a nuclear reactor with rectangular fuel assemblies runs for a long time, impurities and debris may be taken into coolant channels, which may cause flow blockage, and the blocked fuel assemblies might be destroyed. Therefore, the purpose of this study is to perform a thermal-hydraulic analysis of a rectangular fuel assembly by STAR-CCM+, under the condition of one subchannel with 80% blockage ratio. A rectangular fuel assembly of the International Atomic Energy Agency (IAEA) 10 MW material test reactor (MTR) is chosen. In view of the gasket material taken into the coolant channel is close to the single side of the coolant channel, in the flow blockage accident of the Oak Ridge Research Reactor (ORRR), a new blockage category called single side blockage is attempted. The blockage positions include inlet, middle and outlet, and the blockage is set as a cuboid. It is found by simulations that the blockage redistributes the mass flow rate, and large vortices appear locally. The peak temperature of the cladding is maximum, when the blockage is located at the single side of the coolant channel inlet, and no boiling occurs in all blockage cases. Moreover, as the height of the blockage increases, the damage caused by the blockage increases slightly.

An Application of Realistic Evaluation Model to the Large Break LOCA Analysis of Ulchin 3&4

  • C. H. Ban;B. D. Chung;Lee, K. M.;J. H. Jeong;S. T. Hwang
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.429-434
    • /
    • 1996
  • K-REM[1], which is under development as a realistic evaluation model of large break LOCA, is applied to the analysis of cold leg guillotine break of Ulchin 3&4. Fuel parameters on which statistical analysis of their effects on the peak cladding temperature (PCT) are made and system parameters on which the concept of limiting value approach (LVA) are applied, are determined from the single parameter sensitivity study. 3 parameters of fuel gap conductance, fuel thermal conductivity and power peaking factor are selected as fuel related ones and 4 parameters of axial power shape, reactor power, decay heat and the gas pressure of safety injection tank (SIT) are selected as plant system related ones. Response surface of PCT is generated from the plant calculation results and on which Monte Carlo sampling is made to get plant application uncertainty which is statistically combined with code uncertainty to produce the 95th percentile PCT. From the break spectrum analysis, blowdown PCT of 1350.23 K and reflood PCT of 1195.56 K are obtained for break discharge coefficients of 0.8 and 0.5, respectively.

  • PDF

CORE DESIGN FOR HETEROGENEOUS THORIUM FUEL ASSEMBLIES FOR PWR (II) - THERMAL HYDRAULIC ANALYSIS AND SPENT FUEL CHARACTERISTICS

  • BAE KANG-MOK;HAN KYU-HYUN;KIM MYUNG-HYUN;CHANG SOON-HEUNG
    • Nuclear Engineering and Technology
    • /
    • v.37 no.4
    • /
    • pp.363-374
    • /
    • 2005
  • A heterogeneous thorium-based Kyung Hee Thorium Fuel (KTF) assembly design was assessed for application in the APR-1400 to study the feasibility of using thorium fuel in a conventional pressurized water reactor (PWR). Thermal hydraulic safety was examined for the thorium-based APR-1400 core, focusing on the Departure from Nucleate Boiling Ratio (DNBR) and Large Break Loss of Coolant Accident (LBLOCA) analysis. To satisfy the minimum DNBR (MDNBR) safety limit condition, MDNBR>1.3, a new grid design was adopted, that enabled grids in the seed and blanket assemblies to have different loss coefficients to the coolant flow. The fuel radius of the blanket was enlarged to increase the mass flow rate in the seed channel. Under transient conditions, the MDNBR values for the Beginning of Cycle (BOC), Middle of Cycle (MOC), and End of Cycle (EOC) were 1.367, 1.465, and 1.554, respectively, despite the high power tilt across the seed and blanket. Anticipated transient for the DNBR analysis were simulated at conditions of $112\%$ over-power, $95\%$ flow rate, and $2^{\circ}C$ higher inlet temperature. The maximum peak cladding temperature (PCT) was 1,173K for the severe accident condition of the LBLOCA, while the limit condition was 1,477K. The proliferation resistance potential of the thorium-based core was found to be much higher than that of the conventional $UO_2$ fuel core, $25\%$ larger in Bare Critical Mass (BCM), $60\%$ larger in Spontaneous Neutron Source (SNS), and $155\%$ larger in Thermal Generation (TG) rate; however, the radio-toxicity of the spent fuel was higher than that of $UO_2$ fuel, making it more environmentally unfriendly due to its high burnup rate.