• Title/Summary/Keyword: Peak Temperature Limit

Search Result 46, Processing Time 0.029 seconds

Uncertainty Quantification of RELAP5/MOD3/KAERI on Reflood Peak Cladding Temperature (재관수 첨두 피복재 온도에 대한 RELAP5/MOD3/KAERI의 불확실성 정량화)

  • Park, Chan-Eok;Chung, Bub-Dong;Lee, Young-Jin;Lee, Guy-Hyung;Lee, Sang-Yong
    • Nuclear Engineering and Technology
    • /
    • v.26 no.3
    • /
    • pp.389-400
    • /
    • 1994
  • The predictability of KAERI version of RELAP5/MOD3 on reflood peak cladding temperature during large break loss-of-coolant accident is assessed against 18 test runs in FLECHT SEASET test data. The associated uncertainty is statistically quantified. The selected test runs include a gravity feed test and several forced feed tests with wide range of the parameters such as flooding rate, system pressure, initial clad temperature, rod bundle power. The results show that the code under-predicts the peak cladding temperature by 7.56 K on average. The upper limit of the associated uncertainty at 95% confidence level is evaluated to be about 99 K, It including the bias due to the under-prediction.

  • PDF

Thermal Distribution in Living Tissue during Warm Needling Therapy (온침 시술 시 생체 조직 내 열분포 분석에 관한 연구)

  • Kim, Jongyeon;Lee, Jong-Soo
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.24 no.3
    • /
    • pp.111-119
    • /
    • 2014
  • Objectives This study aims to analyze a thermal distribution in biological living tissue during warm needling therapy by using a finite element method. The analysis provides an understanding of warm needling's efficacy and safety. Methods A model which consisted of four-layered tissue and stainless steel needle was adopted to analyze the thermal distribution in living tissue with a bioheat transfer analysis. The governing equation for the analysis was a Pennes' bioheat equation. A heat source characteristic of warm needling therapy was obtained by previous experimental measurements. The first analysis of the time-dependent temperature distribution was conducted through points on a boundary between the needle and the tissue. The second analysis was conducted to visualize the horizontal temperature distribution. Results When heat source's peak temperatures was above $500^{\circ}C$ and temperature rising rates were relatively slow, the peak temperature at skin surface exceeded a threshold of pain and tissue damage ($45^{\circ}C$), whereas when the peak temperature was around $400^{\circ}C$, the peak temperature at the skin surface was within a safe limit. In addition, the conduction of combustion energy from the moxa was limited to the skin layer around the needle. Conclusions The results suggest that the skin layer around the needle can be heated effectively by warm needling therapy, but it appears to have little effect at the deeper tissue. These findings enhance our understanding of the efficacy and the safety of the warm needling therapy.

Characterization of amylopectins isolated from dry and moist type sweet potato starch (분질 및 점질 고구마 전분의 아밀로펙틴 특성)

  • Kim, Sung-Ran;Ahn, Seung-Yo
    • Applied Biological Chemistry
    • /
    • v.34 no.1
    • /
    • pp.26-31
    • /
    • 1991
  • The physicochemical properties of starches from dry(Suwon 147) and moist type(Hwangmi) sweet potato were investigated and molecular structural properties of their amylopectins were also studied by gel chromatography. Suwon 147 starch bad lower swelling power and higher gelatinization temperature than Hwangmi starch. $\beta-Amylolysis\;limit(%)$ of Suwon 147 and Hwangmi amylopectin were 57.6% and 57.0%, respectively. Average unit chain length of amylopectins were 24.8 glucose units for Suwon 147 and 21.9 for Hwangmi. The elution profiles by Sephadex G-50 after debranched amylopectins of the two starches were similar but DPs of each peak were different.

  • PDF

Temperature Effects on the Compaction and Compressive Strength of Soils (온도변화가 흙의 다짐과 압축강도에 미치는 영향)

  • 김재영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.4
    • /
    • pp.3137-3146
    • /
    • 1973
  • This study was to investigate the effects of compaction, compressive strength and Atterberg limits in accordance with the temperatures changes. It was conducted on four soils-KJ, JJ, MH, SS-at temperatures of -1, 1, 3, 5, 7, 10, 15, 19, $22^{\circ}C$. These tests were obtained the maximum dry density and the optimum moisture content of four soils in accordance with temperature changes by using distilled water and $CaCl_2$ 10% solution, and were put to the compressive strength tests on remolded specimens of soils compacted at the optimum moisture content. The result of the study can be summarized as follows; The maximum dry density increased with an increase in temperature, and the use of $CaCl_2$ 10% solution had higher maximum dry density than distilled water. The optimum moisture content decreased with an increase in temperature, and the use of $CaCl_2$ 10% solution had lower optimum moisture content than distilled water. The maximum compressive strength was shown high peak from $7^{\circ}C\;to\;15^{\circ}C$, and the use of $CaCl_2$ 10% solution had higher maximum compressive strength than distilled water. The liquid limit and plasticity index decreased with an increased in temperature. It is estimated that the use of $CaCl_2$ 10% solution can lower the minimum compacted temperature from $2^{\circ}C\;to\;4^{\circ}C$ in low temperature.

  • PDF

Probabilistic Fracture Mechanics Analysis of Boling Water Reactor Vessel for Cool-Down and Low Temperature Over-Pressurization Transients

  • Park, Jeong Soon;Choi, Young Hwan;Jhung, Myung Jo
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.545-553
    • /
    • 2016
  • The failure probabilities of the reactor pressure vessel (RPV) for low temperature over-pressurization (LTOP) and cool-down transients are calculated in this study. For the cool-down transient, a pressure-temperature limit curve is generated in accordance with Section XI, Appendix G of the American Society of Mechanical Engineers (ASME) code, from which safety margin factors are deliberately removed for the probabilistic fracture mechanics analysis. Then, sensitivity analyses are conducted to understand the effects of some input parameters. For the LTOP transient, the failure of the RPV mostly occurs during the period of the abrupt pressure rise. For the cool-down transient, the decrease of the fracture toughness with temperature and time plays a main role in RPV failure at the end of the cool-down process. As expected, the failure probability increases with increasing fluence, Cu and Ni contents, and initial reference temperature-nil ductility transition ($RT_{NDT}$). The effect of warm prestressing on the vessel failure probability for LTOP is not significant because most of the failures happen before the stress intensity factor reaches the peak value while its effect reduces the failure probability by more than one order of magnitude for the cool-down transient.

Comparison of the combustion characteristics between air combustion and oxy-combustion with $CO_2$ recirculation ($CO_2$ 재순환에 의한 순산소 연소와 공기 연소의 화염 특성 비교)

  • Lee, Seung-Hwan;Huh, Kang-Y.
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.3
    • /
    • pp.24-32
    • /
    • 2008
  • Steady Laminar Flamelet Model (SLFM) calculation is performed to compare the turbulent combustion characteristics of air combustion and oxy-combustion with $CO_2$ recirculation. Radiative heat loss is considered by the optically thin limit assumption. For more realistic simulation the first-order conditional moment closure(CMC) model is applied to SANDIA PILOTED FLAME D again for the oxidants of air and mixture of $O_2$ and $CO_2$. The chemical kinetic machanism for methane is GRI Mech 3.0. Results show that oxy flames are much more stable than air flames, while comparable stability is maintained with 65% $CO_2$ recirculation. The comparable peak temperature is maintained with 80% $CO_2$ recirculation. Higher the temperature, higher the fractions of intermediate species, CO and OH, due to dissociation.

  • PDF

A Study on the Power System Application of High-Tc Superconducting Fault Current Limiter (고온초전도 한류기의 전력계통 적용에 관한 연구)

  • Bae, Hyeong-Thaek;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.115-116
    • /
    • 2006
  • Since the discovery of the high-temperature superconductors, many researches have been performed for the practical applications of superconductivity technologies in various fields. As results, significant progress has been achieved. Especially, Superconducting Fault Current Limiter (SFCL) offers an attractive means to limit fault current in power systems. The SFCLS, in contrast to current limiting reactors or high impedance transformers, are capable of limiting short circuit currents without adding considerable voltage drop and energy loss to power systems during normal operation. Under fault conditions, a resistance is automatically inserted into the power grid to limit the peak short-circuit current by transition from the superconducting state to the normal state, the quench. The advantages, like fail safe operation and quick recovery, make SFCL very attractive, especially for rapidly growing power systems with higher short-circuit capacities. In order to verify the effectiveness of the SFCL, in this paper, the analysis of fault current and voltage stability assessment in a sample distribution system and a transmission system are performed by the PSCAD/EMTDC based simulation method. Through the simulation, the advantage of SFCL application is shown, and the effective parameters of the SFCL are also recommended for both distribution and transmission systems. A resistive type component of SFCL is adopted in the analysis. The simulation results demonstrate not only the effectiveness of the proposed simulation scheme but also SFCL parameter assessment technique.

  • PDF

Electrochemical Behaviors of Hydroquinone on a Carbon Paste Electrode with Ionic Liquid as Binder

  • Sun, Wei;Jiang, Qiang;Yang, Maoxia;Jiao, Kui
    • Bulletin of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.915-920
    • /
    • 2008
  • In this paper the electrochemical behaviors of hydroquinone ($H_2Q$) were investigated on a carbon paste electrode using room temperature ionic liquid N-butylpyridinium hexafluorophosphate ($BPPF_6$) as binder (ILCPE) and further applied to $H_2Q$ determination. In pH 2.5 phosphate buffer solution (PBS), the electrochemical response of H2Q was greatly improved on the IL-CPE with a pair of well-defined quasi-reversible redox peaks appeared, which was attributed to the electrocatalytic activity of IL-CPE to the $H_2Q$. The redox peak potentials were located at 0.340 V (Epa) and 0.240 V (Epc) (vs. the saturated calomel electrode, SCE), respectively. The formal potential ($E^0$') was calculated as 0.290 V and the peak-to-peak separation (${\Delta}E_p$) was 0.100 V. The electrochemical parameters of $H_2Q$ on the IL-CPE were further calculated by cyclic voltammetry. Under the selected conditions the anodic peak current was linear with $H_2Q$ concentration over the range from $5.0\;{{\times}}\;10^{-6}$ to $5.0\;{\times}\;10^{-3}\;mol\;L^{-1}$ with the detection limit as $2.5\;{\times}\;10^{-6}\;mol\;L^{-1}$ (3$\sigma$ ) by cyclic voltammetry. The proposed method was successful applied to determination of $H_2Q$ content in a synthetic wastewater sample without the interferences of commonly coexisting substances.

Quantitation and Validation of Atorvastatin using HPLC-UV

  • Heine, Daniel;Yong, Chul-Soon;Kim, Jung-Sun
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.187-192
    • /
    • 2007
  • A reversed phase HPLC analysis of atorvastatin (AS) standard solution was performed using diclofenac (DF) as internal standard. Column oven temperature, flow rate and the composition of the mobile phase were varied in order to determine a practical system setup using a C18 column and UV detector. Two C18 columns of different length were compared regarding their influence on the AS peak shape. Based on these preliminary experiments a validation study was performed utilizing a C18 column at $62^{\circ}C$ with a mobile phase consisting of sodium phosphate buffer (0.05 M, pH 4.0), methanol and acetonitrile (40:50:10, v/v/v). The detection limit for AS was $0.1{\mu}g/ml$ and inter- and intra-day calibration curves were linear over a concentration range of $0.2-50{\mu}g/ml$. Accuracy and precision were satisfactory in the AS concentration range of $0.5-50{\mu}g/ml$.

Study on Ice Making Behavior of Water Solution with Surfactant (계면활성제 첨가수용액의 제빙에 관한 기초연구)

  • ;Hideo Inaba;Akihiko horibe
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1175-1183
    • /
    • 2001
  • Recently, a great attention has been paid to the ice thermal storage system for the purpose of energy saving and reduction in peak electrical demand. In the present study, it has been investigated the freezing behavior of several kinds of water solutions with nonionic surfactant. In order to prevent ice blockage in a cooled pipe, the amount and wall adhesion behavior of ice of the test fluids were observed experimentally under different concentration of water solution with surfactant, temperature of cooled wall, and the shear velocity of test fluids. The results showed that the size of ice crystal became smaller at higher shear velocity at wall. And the lowest limit of wall adhesion of ice in water solution with surfactant was found at 230 W/$m^2$ of heat flux.

  • PDF