• Title/Summary/Keyword: Peak A/V Ratio

Search Result 193, Processing Time 0.021 seconds

A Fully Digital Automatic Gain Control System with Wide Dynamic Range Power Detectors for DVB-S2 Application (넓은 동적 영역의 파워 검출기를 이용한 DVB-S2용 디지털 자동 이득 제어 시스템)

  • Pu, Young-Gun;Park, Joon-Sung;Hur, Jeong;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.9
    • /
    • pp.58-67
    • /
    • 2009
  • This paper presents a fully digital gain control system with a new high bandwidth and wide dynamic range power detector for DVB-S2 application. Because the peak-to-average power ratio (PAPR) of DVB-S2 system is so high and the settling time requirement is so stringent, the conventional closed-loop analog gain control scheme cannot be used. The digital gain control is necessary for the robust gain control and the direct digital interface with the baseband modem. Also, it has several advantages over the analog gain control in terms of the settling time and insensitivity to the process, voltage and temperature variation. In order to have a wide gain range with fine step resolution, a new AGC system is proposed. The system is composed of high-bandwidth digital VGAs, wide dynamic range power detectors with RMS detector, low power SAR type ADC, and a digital gain controller. To reduce the power consumption and chip area, only one SAR type ADC is used, and its input is time-interleaved based on four power detectors. Simulation and measurement results show that the new AGC system converges with gain error less than 0.25 dB to the desired level within $10{\mu}s$. It is implemented in a $0.18{\mu}m$ CMOS process. The measurement results of the proposed IF AGC system exhibit 80-dB gain range with 0.25-dB resolution, 8 nV/$\sqrt{Hz}$ input referred noise, and 5-dBm $IIP_3$ at 60-mW power consumption. The power detector shows the 35dB dynamic range for 100 MHz input.

Studies on the Bionomic of Gonatocerus sp. y (Hymenoptera: Mymaridae), an Egg Parasite of the Green Rice Leafhopper, Nephotettix cincticeps Uhler (끝동매미충 난기생봉(Gonatocerus sp. y)의 생태에 관한 연구)

  • Kim Jeoung Bu;Kim Chang Hyo
    • Korean journal of applied entomology
    • /
    • v.23 no.3 s.60
    • /
    • pp.158-165
    • /
    • 1984
  • These studies were carried out to investigate the bionomics of Gonatocerus sp. y (Hymenoptera: Mymaridae) , an egg parasite of the green rice leafhopper, Nephotettix cincticeps Uhler (Homoptera: Deltocephalidae) under laboratory and field conditions at Gyeongnam Provincial O.R.D. in Jinju from 1982 to 1983. The developmental period of each life stage was observed under four different temperature conditions from $15^{\circ}C\;to\;30^{\circ}C\;with\;5^{\circ}C$ increment. The development from egg to adult at 15^{\circ}C,\;20^{\circ}C,\;25^{\circ}C,\;and\;30^{\circ}C $ was completed in an average of 53, 25, 15, and 12 days and the females laid an average of 28, 48, 42, and 32 eggs respectively, with a maximum of 98. And most of the eggs were laid in the first two days after emergence. The time of adult emergence was determined under $25{\pm}1^{\circ}C$ condition. More than $76\%$ of the wasps emerged in the morning and the rest of them emerged in the afternoon. The average sex ratio between male and female was 1 : 5 when the wasps were developed from fertilized eggs. The longevity of female was greater than that of male when honey and water were provided as food, however, it was not when only water was supplied as food. The average longevities of females were 30 days at $15^{\circ}C$ and 15 days at $20^{\circ}C$ when honey and water were given as food. The peak precent parasitism of Gonatocerus sp. v on Nephotettix cincticeps in fallow fields was observed between late April and early May. The percent parasitism of the wasps In fallow fields was an average of 49\~59.9\% $ in Gyeochang, Namji and $23.2\~36\%$ in Namhae. The parasitic activities of the parasite had four peaks in paddy field, however, the highest peak was observed between late August and early September. The Percent e99 Parasitism of Gonatocerus sp. y was an average of $12.3\%$ on second the generation and $24.6\%$ of third genera lion of Nephotettix cinrticeps.

  • PDF

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF