• Title/Summary/Keyword: Patients with cancer

Search Result 9,735, Processing Time 0.039 seconds

A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam (다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가)

  • Yeom, Misuk;Yoon, Inha;Hong, Donggi;Back, Geummun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.27 no.1
    • /
    • pp.31-43
    • /
    • 2015
  • Purpose : Stereotactic body radiation therapy (SBRT) has proved its efficacy in several patient populations with primary and metastatic limited tumors. Because SBRT prescription is high dose level than Conventional radiation therapy. SBRT plan is necessary for effective Organ at risk (OAR) protection and sufficient Planning target volume (PTV) dose coverage. In particular, multi-target cases may result excessive doses to OAR and hot spot due to dose overlap. This study evaluate usefulness of Volumetric modulated arc therapy (VMAT) in dosimetric and technical considerations using Flattening filter free (FFF) beam. Materials and Methods : The treatment plans for five patients, being treated on TrueBeam STx(Varian$^{TM}$, USA) with VMAT using 10MV FFF beam and Standard conformal radiotherapy (CRT) using 15MV Flattening filter (FF) beam. PTV, liver, duodenum, bowel, spinal cord, esophagus, stomach dose were evaluated using the dose volume histogram(DVH). Conformity index(CI), homogeneity index(HI), Paddick's index(PCI) for the PTV was assessed. Total Monitor unit (MU) and beam on time was assessed. Results : Average value of CI, HI and PCI for PTV was $1.381{\pm}0.028$, $1.096{\pm}0.016$, $0.944{\pm}0.473$ in VMAT and $1.381{\pm}0.042$, $1.136{\pm}0.042$, $1.534{\pm}0.465$ in CRT respectively. OAR dose in CRT plans evaluated 1.8 times higher than VMAT. Total MU in VMAT evaluated 1.3 times increase than CRT. Average beam on time was 6.8 minute in VMAT and 21.3 minute in CRT. Conclusion : VMAT for SBRT in multi-target liver cancer using FFF beam is effective treatment techniqe in dosimetric and technical considerations. VMAT decrease intra-fraction error due to treatment time shortening using high dose rate of FFF beam.

  • PDF

Priming Effect of Endotoxin in Human Alveolar Macrophage (사람 폐포대식세포에서 내독소의 Priming 효과)

  • Chung, Man-Pyo;Yoo, Chul-Gyu;Kim, Young-Whan;Han, Sung-Koo;Shim, Young-Soo;Han, Yong-Chol
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.46-53
    • /
    • 1996
  • Background: Endotoxin or lipopolysaccharide(LPS) can prime phagocytic cells such as polymorphonuclear leukocytes, monocytes or animal peritoneal macrophages to generate increased amounts of secretory products such as oxygen free radicals and tumor necrosis factor, which play an important role in developing adult respiratory distress syndrome in gram negative sepsis. Human alveolar macrophages(HAM) are continuously exposed to various stimuli inhaled into the alveoli, and the response to LPS might be different in HAM. Therefore, we investigated the effect of LPS pre-exposure on HAM adhered to plastic surface and A549 cell(type II human alveolar epithelial cell line) monolayer. Methods: HAM were isolated from bronchoalveolar lavage fluid from normal lung of the patients with localized lung cancer and esophageal cancer. LPS was exposed to HAM for 2hrs before or after adherence to plastic surface of 24-well Linbro plate and A549 cell monolayer. And then HAM was stimulated with PMA(phorbol myristate acetate) or fMLP(N-formyl-methionylleucyl-phenylalanine). The amount of hydrogen peroxide($H_2O_2$) production in the supernatant was measured on the principle of peroxidase-dependent oxidation of phenol red by hydrogen peroxide. Results: LPS pre-exposure could not enhance $H_2O_2$ production in neither HAM adhered to plastic surface nor one to A549 cell monolayer. But LPS even in the absence of PMA or fMLP stimulation directly increased $H_2O_2$ release in HAM if added after the adherence to A549 cell monolayer. Conclusion: Endotoxin does not prime HAM, but may directly activate HAM adhered to alveolar epithelial cells. Further investagation will be necessary.

  • PDF

Detection of Spinal Metastases: Comparison of Bone Scan and MR Imaging (전이성 척추 악성 종양의 진단 : 골스캔과 자기공명영상의 비교)

  • Kim, Ki-Jun;Sohn, Hyung-Sun;Park, Jeong-Mi;Chung, Soo-Kyo;Lee, Jae-Moon;Kim, Choon-Yul;Bahk, Yong-Whee;Shinn, Kyung-Sub
    • The Korean Journal of Nuclear Medicine
    • /
    • v.28 no.3
    • /
    • pp.384-390
    • /
    • 1994
  • Authors retrospectively compared the 99mTc MDP bone scans and corresponding MR imagings in 20 patients with histologically proven malignancy, Mean interval of the two studies was 16.6 days, Cancer diagnosis Included 8 lung, 2 each of colon, breast, stomach, 1 each of prostate, thyroid, malignant lymphoma and 3 adenocarcinoma of unknown primary site. Of the 105 regions compared, :t6 regions were positive for metastases in bone scans or MR imagings. 30 regions(65.2%) were positive by bone scan and 44 regions(95.7%) by MR imaging. 87 regions(82.9%) were concordantly positive or negative by bone scan and MR imaging, but 18 regions(17.1%) were discordant. In the discordant regions, 16 regions positive in MR imaging were negative in bone scan. The greatest number of discordant findings occured in the cervical region and in the patient with stomach cancer. Our results suggest that the sensitivity of MR Imaging is greater than that of bone scan in detecting spinal metastases. And bone scan is useful screening test of metastasis for evaluating entire skeleton including spine.

  • PDF

Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode (호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용)

  • Kim, Sung Ki;Lim, Hhyun Sil;Kim, Wan Sun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.29-35
    • /
    • 2014
  • Purpose : This study has already started commercial Gated RapidArc automation equipment which was not previously in the Gated radiation therapy can be performed simultaneously with the VMAT Gated RapidArc radiation therapy to the accuracy of the analysis to evaluate the usability, Amplitude mode applied to the patient. Materials and Methods : The analysis of the distribution of radiation dose equivalent quality solid water phantom and GafChromic film was used Film QA film analysis program using the Gamma factor (3%, 3 mm). Three-dimensional dose distribution in order to check the accuracy of Matrixx dosimetry equipment and Compass was used for dose analysis program. Periodic breathing synchronized with solid phantom signals Phantom 4D Phantom and Varian RPM was created by breathing synchronized system, free breathing and breath holding at each of the dose distribution was analyzed. In order to apply to four patients from February 2013 to August 2013 with liver cancer targets enough to get a picture of 4DCT respiratory cycle and then patients are pratice to meet patient's breathing cycle phase mode using the patient eye goggles to see the pattern of the respiratory cycle to be able to follow exactly in a while 4DCT images were acquired. Gated RapidArc treatment Amplitude mode in order to create the breathing cycle breathing performed three times, and then at intervals of 40% to 60% 5-6 seconds and breathing exercises that can not stand (Fig. 5), 40% While they are treated 60% in the interval Beam On hold your breath when you press the button in a way that was treated with semi-automatic. Results : Non-respiratory and respiratory rotational intensity modulated radiation therapy technique absolute calculation dose of using computerized treatment plan were shown a difference of less than 1%, the difference between treatment technique was also less than 1%. Gamma (3%, 3 mm) and showed 99% agreement, each organ-specific dose difference were generally greater than 95% agreement. The rotational intensity modulated radiation therapy, respiratory synchronized to the respiratory cycle created Amplitude mode and the actual patient's breathing cycle could be seen that a good agreement. Conclusion : When you are treated Non-respiratory and respiratory method between volumetric intensity modulated radiation therapy rotation of the absolute dose and dose distribution showed a very good agreement. This breathing technique tuning volumetric intensity modulated radiation therapy using a rotary moving along the thoracic or abdominal breathing can be applied to the treatment of tumors is considered. The actual treatment of patients through the goggles of the respiratory cycle to create Amplitude mode Gated RapidArc treatment equipment that does not automatically apply to the results about 5-6 seconds stopped breathing in breathing synchronized rotary volumetric intensity modulated radiation therapy facilitate could see complement.

Development of New 4D Phantom Model in Respiratory Gated Volumetric Modulated Arc Therapy for Lung SBRT (폐암 SBRT에서 호흡동조 VMAT의 정확성 분석을 위한 새로운 4D 팬텀 모델 개발)

  • Yoon, KyoungJun;Kwak, JungWon;Cho, ByungChul;Song, SiYeol;Lee, SangWook;Ahn, SeungDo;Nam, SangHee
    • Progress in Medical Physics
    • /
    • v.25 no.2
    • /
    • pp.100-109
    • /
    • 2014
  • In stereotactic body radiotherapy (SBRT), the accurate location of treatment sites should be guaranteed from the respiratory motions of patients. Lots of studies on this topic have been conducted. In this letter, a new verification method simulating the real respiratory motion of heterogenous treatment regions was proposed to investigate the accuracy of lung SBRT for Volumetric Modulated Arc Therapy. Based on the CT images of lung cancer patients, lung phantoms were fabricated to equip in $QUASAR^{TM}$ respiratory moving phantom using 3D printer. The phantom was bisected in order to measure 2D dose distributions by the insertion of EBT3 film. To ensure the dose calculation accuracy in heterogeneous condition, The homogeneous plastic phantom were also utilized. Two dose algorithms; Analytical Anisotropic Algorithm (AAA) and AcurosXB (AXB) were applied in plan dose calculation processes. In order to evaluate the accuracy of treatments under respiratory motion, we analyzed the gamma index between the plan dose and film dose measured under various moving conditions; static and moving target with or without gating. The CT number of GTV region was 78 HU for real patient and 92 HU for the homemade lung phantom. The gamma pass rates with 3%/3 mm criteria between the plan dose calculated by AAA algorithm and the film doses measured in heterogeneous lung phantom under gated and no gated beam delivery with respiratory motion were 88% and 78%. In static case, 95% of gamma pass rate was presented. In the all cases of homogeneous phantom, the gamma pass rates were more than 99%. Applied AcurosXB algorithm, for heterogeneous phantom, more than 98% and for homogeneous phantom, more than 99% of gamma pass rates were achieved. Since the respiratory amplitude was relatively small and the breath pattern had the longer exhale phase than inhale, the gamma pass rates in 3%/3 mm criteria didn't make any significant difference for various motion conditions. In this study, the new phantom model of 4D dose distribution verification using patient-specific lung phantoms moving in real breathing patterns was successfully implemented. It was also evaluated that the model provides the capability to verify dose distributions delivered in the more realistic condition and also the accuracy of dose calculation.

Hepatitis Complicated with Mycoplasma pneumoniae Infection (Mycoplasma pneumoniae 폐렴에 합병된 간염)

  • Lee, Jin-Tae;Kim, Hee-Sup;Tchah, Hann
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.207-212
    • /
    • 2001
  • Purpose: Mycoplasma pneumoniae infection is relatively common in childhood. Its extrapulmonary manifestations have been reported so much, but hepatitis associated with it has not been studied yet until now in Korea. Methods: We performed the prospective study of 19 cases that had AST and ALT>50 IU/L respectively without evidence of hepatitis A, B, C, cytomegalovirus, and Ebstein-Barr virus infections amongst 143 patients with M. pneumoniae pneumonia who were admitted to the Department of Pediatrics, Seoul Red Cross Hospital from Jan. 1999 to Dec. 2000. Results: 1) Hepatitis occurred in 13.3% of Mycoplasma pneumoniae infection, especially in fall and winter times. The average age was 4.86 years and male to female ratio was 2.2:1. 2) Vomiting was developed in 21.1%, diarrhea in 36.8%, and hepatomegaly in 21.1%, respectively. And leukocytosis was noted in 21.1%, eosinophilia in 15.4%, anemia in 10.5%, and thrombocytosis in 5.3%, respectively. The average level of C-reactive protein was $6.34{\pm}4.82$ mg/dl. 3) There was no hyperbilirubinemia, but hypoalbuminemia was detected in 42.1%. The average serum levels of AST and ALT were $214.05{\pm}183.22$ IU/L and $284.16{\pm}286.84$ IU/L, respectively. 4) Chest radiology showed lobar or lobular consolidation in 73.7%, bronchial infiltration in 26.3%, and pleural effusion in 31.6%. 5) The average length of hospitalization was 7.9 days, and the average length of normalization of serum transaminases was 8.8 days. All patients recovered within 2 weeks completely. Conclusion: The prognosis of M. pneumoniae hepatitis is good. However, its incidence is not so low that liver function should be considerately checked in case of M. pneumoniae infection.

  • PDF

Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI (두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교)

  • Choi, Seung-Jin;Byun, Sung-Su;Park, Sun-Won;Kim, Young-Mo;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.309-315
    • /
    • 2006
  • Purpose: Accurate evaluation of cervical lymph node (LN) metastasis of head and neck squamous cell canter (SCC) is important to treatment planning. We evaluated the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of cervical LN metastasis of head and neck SCC and performed a retrospective comparison with CT/MRI findings. Materials & Methods: Seventeen patients with pathologically proven head and neck SCC underwent F-18 FDG PET/CT and CT/MRI within 4 week before surgery. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. F-18 FDG PET/CT images were analyzed visually for assessment of regional tracer uptake in LN. We analyzed the differences in sensitivity and specificity between F-18 FDG PET/CT and CT/MRI using the Chi-square test. Results: Among the 17 patients, a total of 123 LN levels were dissected, 29 of which showed metastatic involvement. The sensitivity and specificity of F-18 FDG PET/CT for detecting cervical LN metastasis on a level-by-level basis were 69% (20/29) and 99% (93/94). The sensitivity and specificity of CT/MRI were 62% (18/29) and 96% (90/94). There was no significant difference in diagnostic accuracy between F-18 FDG PET/CT and CT/MRI. Interestingly, F-18 FDG PET/CT detected double primary tumor (hepatocellular carcinoma) and rib metastasis, respectively. Conclusion: There was not statistically significant difference of diagnostic accuracy between F-18 FDG PET/CT and CT/MRI for the detection of cervical LN metastasis of head and neck SCC. The low sensitivity of F-18 FDG PET/CT was due to limited resolution for small metastatic deposits.

The Effect of 131I Therapy by Taking in Laxatives (방사성요오드 치료 시 완하제 투여 효과)

  • Kil, Sang-Hyeong;LEE, Hyo-Yeong;Park, Kwang-Yeol;Jo, Kyung-Nam;Baek, Seung-Jo;Hwang, Kyo-Min;Cho, Seong-Mook;Choi, Jae-Hyeok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.3-9
    • /
    • 2014
  • Purpose: Our goals were to evaluate the effect of high dose radioiodine treatment for thyroid cancer by taking in laxatives. Materials and Methods: Twenty patients(M:F=13:7, age $46.3{\pm}8.1\;yrs$) who underwent high dose radioiodine treatment were seperated into Group 1 taking $^{131}I$ 5,500 MBq and Group 2 with the use of laxatives after taking $^{131}I$ 5,500 MBq. The whole body was scanned 16 hours and 40 hours after taking radioactive iodines by using gamma camera, the ROIs were drawn on the gastro-intestinal tract and thigh for calculation of reduction ratio. At particular time during hospitalization, the radioactivity remaining in the body was measured in 1 meter from patient by using survey meter (RadEye-G10, Thermo Fisher Scientific, USA). Schematic presentation of an Origin 8.5.1 software was used for spatial dose rate. Statistical comparison between groups were done using independent samples t-test. P value less than 0.05 was regarded as statistically significant. Results: The reduction ratio in gastro-intestinal 16 hours and 40 hours after taking laxatives is $42.1{\pm}6.3%$ in Group 1 and $72.1{\pm}6.4%$ in Group 2. The spatial dose rate measured when discharging from hospital was $23.8{\pm}6.7{\mu}Sv/h$ in Group 1 and $8.2{\pm}2.4{\mu}Sv/h$ in Group 2. The radioactivity remaining in the body is much decreased at the patient with laxatives(P<0.05). Conclusion: The use in combination with laxatives is helpful for decreasing radioactivity remaining in the body. The radioactive contamination could be decreased at marginal individuals from patients.

  • PDF

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

A Study on IMRT (Intensity Modulated Radiation Therapy) Delivery Technique and FFF (Flattening Filter Free) Beam to Increase Skin Dose to Irregularly Shaped Skin Surface. (IMRT(Intensity Modulated Radiation Therapy)전달 기법과 FFF(Flattening Filter Free) 빔을 이용한 요철 부위 피부 선량 증가 방법에 대한 고찰)

  • Woo Heon;Son Sang Jun;Je Young Wan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.7-12
    • /
    • 2022
  • Purpose: When it is difficult to secure the skin dose when treating Irregularly Shaped Skin Surface such as the nose where it is difficult to apply a bolus, increase the skin dose with a treatment plan that combines the IMRT (Intensity Modulated Radiation Therapy) delivery technique and FFF (Flattening Filter Free), It was tried to find out whether or not through the phantom experiment. Materials & Methods: Based on the 6MV-FF (Flattening Filter) and VMAT (Volumetric-Modulated Arc Therapy) treatment plans, which are the most commonly used treatment plans for head and neck cancer, A comparison group was created by combining VMAT and IMRT, FF and FFF, and the presence or absence of 5 mm bolus application. A virtual target was created on the Rando Phantom's nose, and a virtual bolus of 5 mm was applied assuming full contact on the Rando Phantom's nose. Five measurement points were determined based on the phantom's nose, and the absorbed dose was measured by irradiating each treatment plan 3 times per treatment plan according to the treatment technique and whether or not the bolus was applied. Result: The difference in skin dose in FF vs FFF increased in the case of FFF in VMAT bolus off, and there was no difference in case of IMRT bolus off. In VMAT bolus 5 mm and IMRT bolus 5 mm, it was confirmed that the skin dose was rather decreased in FFF. The difference in skin dose between VMAT and IMRT increased only in the case of FFF bolus off, and there was no statistical difference in the rest. For the difference in skin dose between bolus off vs bolus 5 mm, it was confirmed that the skin dose increased at bolus 5 mm, except for the case of using IMRT FFF. The treatment plan combining IMRT and FFF did not find any statistically significant difference as a result of analyzing the measured values of the treatment plan skin dose applied with a 5 mm bolus using the commonly used VMAT and FF. Therefore, it is thought that by using IMRT_FFF, it is possible to deliver a skin dose similar to that of applying a 5 mm bolus to VMAT_FF, which can be useful for patients who need a high skin dose but have difficulty applying a bolus. Conclusion: For patients who find it difficult to apply bolus, an increase in skin dose can be expected with a treatment plan that properly combines IMRT and FFF compared to VMAT and FF.