Algorithm for Fabricating 3D Breast Implants by Using MRI and 3D Scan Data (MRI와 3D 스캔 데이터를 이용한 3D 프린팅 유방 인공보형물의 제작 알고리즘)

  • Jeong, Young Jin;Choi, Dong Hun;Kim, Ku-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.22 no.12
    • /
    • pp.1385-1395
    • /
    • 2019
  • In this paper, we propose a method to fabricate a patient-specific breast implant using MRI images and 3D scan data. Existing breast implants for breast reconstruction surgery are primarily fabricated products for shaping, and among the limited types of implants, products similar to the patient's breast have been used. In fact, the larger the difference between the shape of the breast and the implant, the more frequent the postoperative side effects and the lower the satisfaction. Previous researches on the fabrication of patient-specific breast implants have used limited information based on only MRI images or on only 3D scan data. In this paper, we propose an algorithm for the fabrication of patient-specific breast implants that combines MRI images with 3D scan data, considering anatomical suitability for external shape, volume, and pectoral muscle. Experimental results show that we can produce precise breast implants using the proposed algorithm.

Patient-specific implants for maxillofacial defects: challenges and solutions

  • Alasseri, Nasser;Alasraj, Ahmed
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.15.1-15.8
    • /
    • 2020
  • Background: Reconstructing maxillofacial defects is quite challenging for most surgeons due to the region's complex anatomy and cosmetic and functional effects on patients. The use of pre-made alloplastic implants and autogenous grafts is often associated with resorption, infection, and displacement. Recent technological advances have led to the use of custom computer-designed patient-specific implants (PSIs) in reconstructive surgery. This study describes our experience with PSI, details the complications we faced, how to overcome them, and finally, evaluates patient satisfaction. Case presentation: Six patients underwent reconstruction of various maxillofacial defects arising due to different etiologies using PSI. A combined total of 10 implants was used. PEEK was used to fabricate 8, while titanium was used to fabricate 2. No complications were seen in any patient both immediately post-op and in subsequent follow-ups. All patients reported a high level of satisfaction with the final result both functionally and cosmetically. Conclusion: The use of computer-designed PSI enables a more accurate reconstruction of maxillofacial defects, eliminating the usual complications seen in preformed implants and resulting in higher patient satisfaction. Its main drawback is its high cost.

Patient-specific implants in reverse shoulder arthroplasty

  • Emil R Haikal;Mohamad Y. Fares;Joseph A. Abboud
    • Clinics in Shoulder and Elbow
    • /
    • v.27 no.1
    • /
    • pp.108-116
    • /
    • 2024
  • Reverse total shoulder arthroplasty (RTSA) is widely popular among shoulder surgeons and patients, and its prevalence has increased dramatically in recent years. With this increased use, the indicated pathologies associated with RTSA are more likely to be encountered, and challenging patient presentations are more likely to be seen. One prominent challenging presentation is RTSA patients with severe glenoid bone loss. Several techniques with varying degrees of invasiveness, including excessive reaming, alternate centerline, bone grafting, and patient-specific implants (PSIs), have been developed to treat patients with this presentation. PSI treatment uses a three-dimensional reconstruction of a computed tomography scan to design a prosthetic implant or component customized to the patient's glenoid morphology, allowing compensation for any significant bone loss. The novelty of this technology implies a paucity of available literature, and although many studies show that PSIs have good potential for solving challenging shoulder problems, some studies have reported questionable and equivocal outcomes. Additional research is needed to explore the indications, outcomes, techniques, and cost-efficiency of this technology to help establish its role in current treatment guidelines and strategies.

Evaluation of failed implants and reimplantation at sites of previous dental implant failure: survival rates and risk factors

  • Park, Yu-Seon;Lee, Bo-Ah;Choi, Seong-Ho;Kim, Young-Taek
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.3
    • /
    • pp.230-241
    • /
    • 2022
  • Purpose: The purpose of this study was to evaluate failed implants and reimplantation survival and to identify the relative risk factors for implant re-failure. Methods: Ninety-one dental implants were extracted between 2006 and 2020 at the National Health Insurance Service Ilsan Hospital, including 56 implants in the maxilla and 35 implants in the mandible that were removed from 77 patients. Patient information (e.g., age, sex, and systemic diseases) and surgical information (e.g., the date of surgery and location of the implants and bone grafts) were recorded. If an implant prosthesis was used, prosthesis information was also recorded. Results: In total, 91 first-time failed dental implants in 77 patients were analyzed. Of them, 69 implants in 61 patients received reimplantation after failure. Sixteen patients (22 implants) refused reimplantation or received reimplantation at a different site. Eight of the 69 reimplants failed again. The 1-year survival rate of the 69 reimplants was 89.4%. Age at reimplantation and smoking significantly increased the risk of reimplantation failure. However, a history of taking anti-thrombotic agents showed a statistically significant negative association with reimplantation failure. Of the failed implants, 66% showed early failure and 34% showed late failure of the initial implantation. All 8 re-failed implants showed early failure. Only 3 of these 8 failed reimplants were re-tried and the second reimplants all survived. Conclusions: The total survival rate of implants, which included reimplants and second reimplants was 99.2%, although the survival rate of the initial implantations was 96.3%. Previous failure did not affect the success of the next trial. Reimplantation failure was more strongly affected by patient factors than by implant factors. Therefore, each patient's specific factors need to be meticulously controlled to achieve successful reimplantation.

Design and 3D-printing of titanium bone implants: brief review of approach and clinical cases

  • Popov Jr, Vladimir V.;Muller-Kamskii, Gary;Kovalevsky, Aleksey;Dzhenzhera, Georgy;Strokin, Evgeny;Kolomiets, Anastasia;Ramon, Jean
    • Biomedical Engineering Letters
    • /
    • v.8 no.4
    • /
    • pp.337-344
    • /
    • 2018
  • Additive manufacturing (AM) is an alternative metal fabrication technology. The outstanding advantage of AM (3D-printing, direct manufacturing), is the ability to form shapes that cannot be formed with any other traditional technology. 3D-printing began as a new method of prototyping in plastics. Nowadays, AM in metals allows to realize not only net-shape geometry, but also high fatigue strength and corrosion resistant parts. This success of AM in metals enables new applications of the technology in important fields, such as production of medical implants. The 3D-printing of medical implants is an extremely rapidly developing application. The success of this development lies in the fact that patient-specific implants can promote patient recovery, as often it is the only alternative to amputation. The production of AM implants provides a relatively fast and effective solution for complex surgical cases. However, there are still numerous challenging open issues in medical 3D-printing. The goal of the current research review is to explain the whole technological and design chain of bio-medical bone implant production from the computed tomography that is performed by the surgeon, to conversion to a computer aided drawing file, to production of implants, including the necessary post-processing procedures and certification. The current work presents examples that were produced by joint work of Polygon Medical Engineering, Russia and by TechMed, the AM Center of Israel Institute of Metals. Polygon provided 3D-planning and 3D-modelling specifically for the implants production. TechMed were in charge of the optimization of models and they manufactured the implants by Electron-Beam Melting ($EBM^{(R)}$), using an Arcam $EBM^{(R)}$ A2X machine.

Comparison of Biomechanical Stability of Custom-made Hip Implants using Finite Element Analysis (스템 길이에 따른 환자맞춤 인공고관절의 역학적 안정성 비교)

  • Jun, Yongtae
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.4
    • /
    • pp.426-432
    • /
    • 2016
  • Designing a morphologically well-fitted hip implant to a patient anatomy is desirable to improve surgical outcomes since a commercial ready-made hip implant may not well conform to the patient joint. In this study, biomechanical stability of patient-specific hip implants with two different stem lengths was compared and discussed using a 3D finite element analysis (FEA). The FEA results in this study showed that an increase in stem length brings about more the peaked von-Mises stress (PVMS) in the prosthesis and less in the femur. However the decrease in von-Mises stress in the femur causes stress shielding phenomenon that usually leads to considerable bone resorption. Although, in biomechanical stability point of view, this work recommends the use of smaller stems, the length of stem must be determined by considering both the von-Mises stress and the stress-shielding phenomenon.

Orthodontic-prosthodontic interdisciplinary treatment for a patient with multiple missing posterior teeth and unilateral scissors bite (다수의 구치 상실과 편측성 가위교합을 갖는 환자의 보철 교정 협진 치료)

  • An, Kiyong
    • The Journal of the Korean dental association
    • /
    • v.53 no.11
    • /
    • pp.844-854
    • /
    • 2015
  • This clinical report describes an orthodontic-prosthodontic interdisciplinary treatment for a patient with multiple missing teeth and unilateral scissors bite. A 47-year-old female presented with multiple missing posterior teeth, anterior large overjet, deep bite, and posterior scissors bite on the right premolar area. Periodontal therapy was performed and followed by orthodontic treatment. The maxillary anterior teeth were initially aligned, then two implants were placed for the left mandibular molars to increase occlusal vertical dimension. The scissors bite between the right maxillary and mandibular premolars were corrected using the miniscrews as an anchorage. Other implants were placed for the right maxillary and mandibular molars after the occlusal planes and occlusal relationship were harmonized. The patient adapted well to altered vertical dimension without any specific problems including peri-implant marginal bone loss. Interdisciplinary approach resolve the complex orthodontic-prosthodontic problems and concluded in successful results.

Skull Reconstruction with Custom Made Three-Dimensional Titanium Implant

  • Cho, Hyung Rok;Roh, Tae Suk;Shim, Kyu Won;Kim, Yong Oock;Lew, Dae Hyun;Yun, In Sik
    • Archives of Craniofacial Surgery
    • /
    • v.16 no.1
    • /
    • pp.11-16
    • /
    • 2015
  • Background: Source material used to fill calvarial defects includes autologous bones and synthetic alternatives. While autologous bone is preferable to synthetic material, autologous reconstruction is not always feasible due to defect size, unacceptable donor-site morbidity, and other issues. Today, advanced three-dimensional (3D) printing techniques allow for fabrication of titanium implants customized to the exact need of individual patients with calvarial defects. In this report, we present three cases of calvarial reconstructions using 3D-printed porous titanium implants. Methods: From 2013 through 2014, three calvarial defects were repaired using custom-made 3D porous titanium implants. The defects were due either to traumatic subdural hematoma or to meningioma and were located in parieto-occipital, fronto-temporo-parietal, and parieto-temporal areas. The implants were prepared using individual 3D computed tomography (CT) data, Mimics software, and an electron beam melting machine. For each patient, several designs of the implant were evaluated against 3D-printed skull models. All three cases had a custom-made 3D porous titanium implant laid on the defect and rigid fixation was done with 8 mm screws. Results: The custom-made 3D implants fit each patient's skull defect precisely without any dead space. The operative site healed without any specific complications. Postoperative CTs revealed the implants to be in correct position. Conclusion: An autologous graft is not a feasible option in the reconstruction of large calvarial defects. Ideally, synthetic materials for calvarial reconstruction should be easily applicable, durable, and strong. In these aspects, a 3D titanium implant can be an optimal source material in calvarial reconstruction.

Late reconstruction of extensive orbital floor fracture with a patient-specific implant in a bombing victim

  • Smeets, Maximiliaan;Snel, Robin;Sun, Yi;Dormaar, Titiaan;Politis, Constantinus
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.46 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • Fractures of the orbital floor and walls are among the most frequent maxillofacial fractures. Virtual three-dimensional (3D) planning and use of patient-specific implants (PSIs) could improve anatomic and functional outcomes in orbital reconstruction surgery. The presented case was a victim of a terrorist attack involving improvised explosive devices. This 58-year-old female suffered severe wounds caused by a single piece of metal from a bomb, shattering the left orbital floor and lateral orbital wall. Due to remaining hypotropia of the left eye compared to the right eye, late orbital floor reconstruction was carried out with a personalised 3D printed titanium implant. We concluded that this technique with PSI appears to be a viable method to correct complex orbital floor defects. Our research group noted good aesthetic and functional results one year after surgery. Due to the complexity of the surgery for a major bony defect of the orbital floor, it is important that the surgery be executed by experienced surgeons in the field of maxillofacial traumatology.