• Title/Summary/Keyword: Patient-only bathroom

Search Result 2, Processing Time 0.02 seconds

A Study on the Surface Contamination Level and Spatial Dose Rate Measured from NM Patients-Only Bathroom (핵의학과 전용화장실에서 측정된 표면오염도 및 공간선량율에 대한 연구)

  • Moon, Jae-Seung;Jeong, Hyi-Il;Jeong, Hae-Seong;Sin, Min-Yong;Kim, Su-Geun;Park, Dae-Seong;Kim, Hyun-Ki;Kim, Hwa-San;Lee, Hyung-Nam;Ahn, Byeong-Pil;Lee, Dong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.38-43
    • /
    • 2012
  • Purpose: Patients injected with FDG use the bathroom that Measured surface contamination level and spatial dose rate. This study about the effect that result affects workers in same part. Materials and Methods: Group1 is St. Vincent' s hospital's 60case. Group 2 is Bucheon St. Mary's hospital's 50case. Last case is lower the average daily number of patients than group 2. Measured time is 8:00, 10:00, 13:00, 15:00 and 17:00. Measured part is 4 point of toilet, basin and wastepaper basket, also measured accumulation dose of toilet during 3 month. Hospitals is installed PET/CT ware surveyed on presence of bathroom that used only by patient and worker has been using the bathroom. Results: The highest average surface contamination level of toilet is group1($8.38{\pm}4.56$), but the highest spatial dose rate is group3. Cumulative exposure dose measured by TLD during 3months is St.Vincent's hospital 0.78 mSv and Bucheon St.Mary's hospital 0.37 mSv. And result of survey is 16.12% worker using the bathroom. Conclusions: The more daily number of patient, the higher surface contamination level of bathroom. Especially, wastepaper basket's surface contamination level is exceed the reference value $4Bq/cm^2$. Based on This survey, Bathroom require special attention and proper decontamination.

  • PDF

Nurses' Needs for the Spatial Composition of Geriatric Hospital (노인요양병원의 공간구성에 대한 간호사 요구)

  • Oh, Chan-Ohk
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.20 no.4
    • /
    • pp.7-16
    • /
    • 2014
  • Purpose : The purpose of this study was to examine the nurses' needs for the spatial composition of geriatric hospital. Methods : The survey method was used for collecting the data. The subjects were 110 nurses who worked at 6 geriatric hospitals in Busan. They answered the questionnaire by the self-administered method. The questionnaire consisted of items which asked the spatial composition of patient room, bathroom, dining space, resting space, care-givers' room, and garden. Results : 1) The patient room using a bed on ondol floor would be useful. Also, it would be desirable that most patient rooms consisted of 4 or 6 persons per patient room and the others were 1 or 2 persons per room. 2) The bathroom for only patients and the shower room for their families or care-givers are needed in the geriatric hospital. 3) The dining room for patients in each floor would be useful to old patients. In addition to that, the cafeteria for their families or care-givers are needed. 4) The resting space for patients and their families, for the staff, and for care-givers are needed. 5) The personal locker and refrigerator are necessary fixtures in care-givers' room. Also, table, sofa, sink, and shower booth are also needed. 6) On the base of activities of care-givers, the space for preserving, washing, and heating foods are needed. Also, the storage space for personal items and the fitting space are needed. Implications : The results of this study would be the fundamental data for space planning of the geriatric hospital.