• 제목/요약/키워드: Patient-based

검색결과 5,629건 처리시간 0.042초

Associations Between Heart Rate Variability and Symptom Severity in Patients With Somatic Symptom Disorder (신체 증상 장애 환자의 심박변이도와 증상 심각도의 연관성)

  • Eunhwan Kim;Hesun Kim;Jinsil Ham;Joonbeom Kim;Jooyoung Oh
    • Korean Journal of Psychosomatic Medicine
    • /
    • 제31권2호
    • /
    • pp.108-117
    • /
    • 2023
  • Objectives : Somatic symptom disorder (SSD) is characterized by the manifestation of a variety of physical symptoms, but little is known about differences in autonomic nervous system activity according to symptom severity, especially within patient groups. In this study, we examined differences in heart rate variability (HRV) across symptom severity in a group of SSD patients to analyze a representative marker of autonomic nervous system changes by symptoms severity. Methods : Medical records were retrospectively reviewed for patients who were diagnosed with SSD based on DSM-5 from September 18, 2020 to October 29, 2021. We applied inverse probability of treatment weighting (IPTW) methods to generate more homogeneous comparisons in HRV parameters by correcting for selection biases due to sociodemographic and clinical characteristic differences between groups. Results : There were statistically significant correlations between the somatic symptom severity and LF (nu), HF (nu), LF/HF, as well as SD1/SD2 and Alpha1/Alpha2. After IPTW estimation, the mild to moderate group was corrected to 27 (53.0%) and the severe group to 24 (47.0%), and homogeneity was achieved as the differences in demographic and clinical characteristics were not significant. The analysis of inverse probability weighted regression adjustment model showed that the severe group was associated with significantly lower RMSSD (β=-0.70, p=0.003) and pNN20 (β=-1.04, p=0.019) in the time domain and higher LF (nu) (β=0.29, p<0.001), lower HF (nu) (β=-0.29, p<0.001), higher LF/HF (β=1.41, p=0.001), and in the nonlinear domain, significant differences were tested for SampEn15 (β=-0.35, p=0.014), SD1/SD2 (β=-0.68, p<0.001), and Alpha1/Alpha2 (ß=0.43, p=0.001). Conclusions : These results suggest that differences in HRV parameters by SSD severity were showed in the time, frequency and nonlinear domains, specific parameters demonstrating significantly higher sympathetic nerve activity and reduced ability of the parasympathetic nervous system in SSD patients with severe symptoms.

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제61권4호
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • 제18권1호
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • 제35권
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Cases and Legal Issues For 119paramedics in Mental Emergency Situations (정신응급상황에서 119구급대원 대응사례와 법적쟁점)

  • Young Pyo Hong
    • The Korean Society of Law and Medicine
    • /
    • 제25권1호
    • /
    • pp.87-115
    • /
    • 2024
  • In Korea, exposure to stress has been accompanied by mental pain in the process of achieving many growth along with rapid development, various social problems, and the frequency of emergency hospitalization is increasing.. In the case of mentally ill patients, "unwanted hospitalization" is a problem, and police and 119 paramedics try to suppress the body of mentally ill patients, and many problems are exposed This is because the constituent requirements of the provisions of emergency hospitalization under the Mental Health and Welfare Act do not reflect reality, and each institution has a different position on one mentally ill person, and emergency hospitalization does not proceed smoothly or leads to friction between related organizations, and the safety of the mentally ill or others is not secured. Emergency hospitalization is defined as "a person who finds a person who is presumed to be mentally ill and is at high risk of harming his or her health or safety or others," and if the situation is so urgent that he or she cannot afford time to go through the hospitalization procedure to decide on his or her own hospitalization, he or she can request emergency hospitalization with the consent of a doctor and a police officer. In this case, 119 paramedics are escorted to a psychiatric institution. This provision of emergency hospitalization poses many problems in the process of transferring to psychiatric institutions. If a police officer or 119 paramedics in charge of practice use "physical force" during the emergency hospitalization process, side effects will inevitably occur, and professional negligence can be a problem. Specifically, when exercising physical force, the minimum necessary physical restraint based on laws and regulations and proportional principles is required, and the lack of the duty of care of 119 paramedics or police officers under the laws and regulations will eventually be resolved by applying other laws and regulations. Accordingly, it will be an opportunity for mentally ill patients to be transferred to psychiatric institutions in a safe environment by changing the subject of emergency hospitalization provisions under the Mental Health Welfare Act, defining and prescribing the use of physical protection guards as the enforcement regulations of the Mental Health Act, setting the duty of care for 119 paramedics and police officers, and creating an environment for transportation so that mentally ill patients can be treated safely.

Usefulness of Corticomedullary-Phase CT Urography in Patients with Suspected Acute Renal Colic Visiting the Emergency Department (응급실을 방문하는 급성신산통이 의심되는 환자에서 요로조영술 컴퓨터단층촬영의 피질-수질기의 유용성)

  • Seokyoung Lee;Yang Shin Park;Bitna Park;Jongmee Lee;Jae Woong Choi;Kyeong Ah Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • 제84권4호
    • /
    • pp.923-933
    • /
    • 2023
  • Purpose To evaluate the sensitivity of corticomedullary-phase imaging for detecting urinary stones in patients with renal colic who visited the emergency department. Materials and Methods This retrospective study included 253 patients with suspected renal colic from two tertiary hospitals in South Korea, who visited the emergency department and underwent CT urography. Two radiologists blinded to the clinical history independently reviewed the corticomedullary-phase images. The sensitivity for identifying urinary stones were evaluated for each reviewer. After the initial evaluation, the images were re-evaluated based on patient history. The sensitivity of re-evaluation were recorded. Results Of 253 patients, 150 (59%) had urinary stones. Among them, significant stones were observed in 138 patients (92%), and obstructive changes on CT in 124 patients (82.7%). For identifying significant urinary stones, the sensitivity was 98.6% (136/138) for both the reviewers. For identifying significant urinary stones with urinary obstruction, the sensitivity was 99.2% (123/124) for reviewer 1, and 100% (124/124) for reviewer 2. The sensitivity for identifying significant stones increased from 98.6% to 100% for reviewer 1, and from 98.6% to 99.3% for reviewer 2 in the re-evaluation session. Conclusion The corticomedullary-phase CT urography was sensitive for diagnosing urolithiasis in patients with acute renal colic who visited the emergency department.

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • 제84권2호
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.

Discordance Between Angiographic Assessment and Fractional Flow Reserve or Intravascular Ultrasound in Intermediate Coronary Lesions: A Post-hoc Analysis of the FLAVOUR Trial

  • Jung-Hee Lee;Sung Gyun Ahn;Ho Sung Jeon;Jun-Won Lee;Young Jin Youn;Jinlong Zhang;Xinyang Hu;Jian'an Wang;Joo Myung Lee;Joo-Yong Hahn;Chang-Wook Nam;Joon-Hyung Doh;Bong-Ki Lee;Weon Kim;Jinyu Huang;Fan Jiang;Hao Zhou;Peng Chen;Lijiang Tang;Wenbing Jiang;Xiaomin Chen;Wenming He;Myeong-Ho Yoon;Seung-Jea Tahk;Ung Kim;You-Jeong Ki;Eun-Seok Shin;Doyeon Hwang;Jeehoon Kang;Hyo-Soo Kim;Bon-Kwon Koo
    • Korean Circulation Journal
    • /
    • 제54권8호
    • /
    • pp.485-496
    • /
    • 2024
  • Background and Objectives: Angiographic assessment of coronary stenosis severity using quantitative coronary angiography (QCA) is often inconsistent with that based on fractional flow reserve (FFR) or intravascular ultrasound (IVUS). We investigated the incidence of discrepancies between QCA and FFR or IVUS, and the outcomes of FFR- and IVUS-guided strategies in discordant coronary lesions. Methods: This study was a post-hoc analysis of the FLAVOUR study. We used a QCA-derived diameter stenosis (DS) of 60% or greater, the highest tertile, to classify coronary lesions as concordant or discordant with FFR or IVUS criteria for percutaneous coronary intervention (PCI). The patient-oriented composite outcome (POCO) was defined as a composite of death, myocardial infarction, or revascularization at 24 months. Results: The discordance rate between QCA and FFR or IVUS was 30.2% (n=551). The QCA-FFR discordance rate was numerically lower than the QCA-IVUS discordance rate (28.2% vs. 32.4%, p=0.050). In 200 patients with ≥60% DS, PCI was deferred according to negative FFR (n=141) and negative IVUS (n=59) (15.3% vs. 6.5%, p<0.001). The POCO incidence was comparable between the FFR- and IVUS-guided deferral strategies (5.9% vs. 3.4%, p=0.479). Conversely, 351 patients with DS <60% underwent PCI according to positive FFR (n=118) and positive IVUS (n=233) (12.8% vs. 25.9%, p<0.001). FFR- and IVUS-guided PCI did not differ in the incidence of POCO (9.5% vs. 6.5%, p=0.294). Conclusions: The proportion of QCA-FFR or IVUS discordance was approximately one third for intermediate coronary lesions. FFR- or IVUS-guided strategies for these lesions were comparable with respect to POCO at 24 months.

The Effect of Grid Focus Distance on Patient Dose, Exposure Index, and Image Quality in Digital Abdominal Radiography (격자의 초점거리가 디지털 복부 방사선검사의 환자선량 및 노출지수 그리고 영상 품질에 미치는 영향)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • 제18권5호
    • /
    • pp.523-529
    • /
    • 2024
  • The purpose of this study is to investigate the effect of differences in grid focal distance used in general radiography on the exposure index and image quality, and to provide useful information for the application of grids in clinical radiography. With AEC applied and SID set to 110 cm, 30 images were obtained for each focus distance of the grid at 110 cm, 140 cm, and 180 cm under the same exposure conditions. The dose was measured using the DAP and ESD, while image quality was evaluated using the SNR and CNR. The exposure index (EI) was determined based on the values shown in the image. EI was derived from the values indicated in the images. The mean DAP values at focus distances of 180, 140, and 110 cm were 10.944±0.613, 10.687±0.516, and 9.74±0.588 cGy·cm2, respectively. The ESD values were 1041.75±57.92, 1019.99±49.61, and 930.86±55.77 μGy, while the EI values were 205.97±11.77, 210.59±10.37, and 193.8±11.86. The SNR values were 28.48±0.62, 28.41±0.64, and 27.13±0.72 dB, and the CNR values were 0.09859±0.004276, 0.09864±0.004378, and 0.09026±0.004783 dB. The differences in the mean values were statistically significant (p < 0.01). The values were significantly higher at focal distances of 140 cm and 180 cm compared to 110 cm, but there was no significant difference between the focal distances of 140 cm and 180 cm. The correlation analysis results revealed significant negative correlations between FD and DAP (r = -0.642, p < 0.01), ESD (r = -0.629, p < 0.01), EI (r = -0.376, p < 0.01), SNR (r = -0.615, p < 0.01), and CNR (r = -0.575, p < 0.01) for all variables. The results of this study showed a moderate negative correlation between the focus distance of the grid and the SNR, CNR, DAP, and ESD, and a weak negative correlation with the EI. Therefore, radiological technologists should be aware that even when the same exposure conditions are applied using an AEC system, variations in focus distance of the grid can affect the exposure index, dose, and image quality. Careful consideration is needed when setting the target exposure index.

Multimodality Treatement in Patients with Clinical Stage IIIA NSCLC (임상적 IIIA병기 비소세포폐암의 다각적 치료의 효과)

  • Lee, Yun Seun;Jang, Pil Soon;kang, Hyun Mo;Lee, Jeung Eyun;Kwon, Sun Jung;An, Jin Yong;Jung, Sung Soo;Kim, Ju Ock;Kim, Sun Young
    • Tuberculosis and Respiratory Diseases
    • /
    • 제57권6호
    • /
    • pp.557-566
    • /
    • 2004
  • Background : To find out effectiveness of multimodality treatments based on induction chemotherapy(CTx) in patients with clinical stage IIIA NSCLC Methods : From 1997 to 2002, 74 patients with clinical stage IIIA NSCLC underwent induction CTx at the hospital of Chungnam National University. Induction CTx included above two cycles of cisplatin-based regimens(ectoposide, gemcitabine, vinorelbine, or taxol) followed by tumor evaluation. In 30 complete resection group, additional 4500-5000cGy radiotherapy(RTx) was delivered in 15 patients with pathologic nodal metastasis. 29 out of 44 patients who were unresectable disease, refusal of operation, and incomplete resection were followed by 60-70Gy RTx in local treatment. Additional 1-3 cycle CTx were done in case of induction CTx responders in both local treatment groups. Results : Induction CTx response rate were 44.6%(complete remission 1.4% & partial response 43.2%) and there was no difference of response rate by regimens(p=0.506). After induction chemotherapy, only 33 out of resectable 55 ones(including initial resectable 37 patients) were performed by surgical treatment because of 13 refusal of surgery by themselves and 9 poor predicted reserve lung function. There were 30(40.5%) patients with complete resection, 2(2.6%) persons with incomplete resection, and 1(1.3%) person with open & closure. Response rate in 27 ones with chest RTx out of non-operation group was 4.8% CR and 11.9% PR. In complete resection group, relapse free interval was 13.6 months and 2 year recur rate was 52%. In non-complete resection(incomplete resection or non-operation) group, disease progression free interval was 11.2 months and 2 year disease progression rate was 66.7%. Median survival time of induction CTx 74 patients with IIIA NSCLC was 25.1months. When compared complete resection group with non-complete resection group, the median survival time was 31.7 and 23.4months(p=0.024) and the 2-year overall survival rate was 80% and 41%. In the complete resection group, adjuvant postoperative RTx subgroup significantly improved the 2-year local control rate(0% vs. 40%, p= 0.007) but did not significantly improve overall survival(32.2months vs. 34.9months, p=0.48). Conculusion : Induction CTx is a possible method in the multimodality treatments, especially followed by complete resection, but overall survival by any local treatment(surgical resection or RTx) was low. Additional studies should be needed to analysis data for appropriate patient selection, new chemotherapy regimens and the time when should RTx be initiated.