• Title/Summary/Keyword: Patient-based

Search Result 5,550, Processing Time 0.117 seconds

The Study about the Changes of the Fire and Heat Related Symptoms and Signs On the Acute Cerebral Infarction Patients. (급성기 뇌경색 환자에서 화열 관련 증상과 증후의 변화에 관한 연구)

  • Kwak, Seung-hyuk;Park, Su-kyung;Woo, Su-kyung;Lee, Eun-chan;Park, Joo-young;Jung, Woo-sang;Moon, Sang-kwan;Cho, Ki-ho;Cho, Seung-yeon;Park, Sung-wook;Ko, Chang-nam
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.24-31
    • /
    • 2011
  • Objective : Fire and heat related symptoms and signs are considered common in acute stage of diseases. The purpose of this study is to evaluate the occurrences and changes of fire and heat related symptoms and signs in acute cerebral infarction patients. Method & subjects : 40 acute cerebral infarction patients hospitalized in Oriental medicine hospital, Kyung-Hee University, who had examined and diagnosed 2 or 3 times based on oriental medical diagnosis were selected. We chose 23 as fire and heat related symptoms and signs from 94 diagnostic articles, and we added all those scores together of each patient. We analysed the scores of fire and heat related symptoms and signs as the time passed, and depending on oriental medical diagnosis. Result : In acute cerebral infarction patients of this study, 4 of fire and heat related symptoms and signs were took 1st, 2nd, 4th and 8th places in most changeable 10 articles of total 94 articles. The mean score of fire and heat related symptoms and signs of all patients were decreased significantly over the 3 times of measurements. The 8 patients diagnosed as fire and heat diagnosis at visit1 were samely diagnosed as fire and heat diagnosis at visit2, and at visit3 5 patients of them except for 3 patients excluded between visit2 and visit3, were still diagnosed as fire and heat diagnosis. At all of 3 measuring times, the scores of fire and heat related symptoms and signs of fire and heat diagnosis group were higher than non-fire and heat diagnosis group. Conclusion : This study indicated that fire and heat related symptoms and signs were very changeable phenomenon in acute cerebral infarction patients. And they decreased as time goes on.

  • PDF

A Case of Urologic Manifestation of IARS2-associated Leigh Syndrome (IARS2 유전자 연관 리 증후군(Leigh syndrome) 여아에서 방광기능장애 증례)

  • Hyunjoo Lee;Ji-Hoon Na;Young-Mock Lee
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.23 no.1
    • /
    • pp.25-30
    • /
    • 2023
  • Leigh syndrome is a rare progressive neurodegenerative mitochondrial disorder with clinical and genetic heterogeneity. Recently, balletic IARS2 variants have been identified in a number of patients presenting broad clinical phenotypes from Leigh and West syndrome to a rare syndrome CAGSSS characterized by cataracts, growth hormone deficiency, sensory neuropathy, sensorineural hearing loss, and skeletal dysplasia syndrome (OMIM#616007). We describe a child with Korean Leigh syndrome with urologic manifestations resulting from a compound heterozygote mutation in IARS2. A 5-year-old girl visited the emergency room with a complaint of abdominal pain accompanied by abdominal distension. Abdominal-pelvic CT showed a markedly distended urinary bladder without definite obstructive lesions. She was diagnosed with neurogenic bladder dysfunction based on a urodynamic study. She had global delayed development due to neurologic regression after 6 months of age and a history of bilateral cataract surgery at the age of 2 years. Her brain magnetic resonance imaging showed symmetrically increased signal intensities in the bilateral putamen and caudate nuclei with diffuse cerebral atrophy. No gene variants were identified through whole-mitochondrial genome analysis. Whole exome sequencing was performed for diagnosis, and compound heterozygous pathogenic variants were identified in IARS2: c.2446C>T (p. Arg816Ter) and c.2450G>A (p. Arg817His). To the best of our knowledge, this is the first case report of bladder dysfunction manifestation in a patient with IARS2-related Leigh syndrome. Thus, it broadens the clinical and genetic spectrum of IARS2-associated diseases.

  • PDF

Effects of Tailored Occupational Activity Program applied to Patients with Dementia and Their Caregiver in Community (지역사회에 거주하는 치매환자와 보호자에게 적용한 맞춤형 작업 활동 프로그램의 효과)

  • Hwang, Yun-Jung;Lee, Kamg Sook;Lim, Hyun-Kook;Kim, Dai Jin;Jeong, Won-Mee
    • 한국노년학
    • /
    • v.31 no.1
    • /
    • pp.129-141
    • /
    • 2011
  • This study aims to find out effects of a tailored occupational activity program(TOAP) on the activities of daily living(ADL), cognitive function, depressive mood, and caregiver burden, who live in the community. Method : From October 2009 to May 2010, the TOAP was applied to 15 dementia patients and 15 of their caregivers, who was visitors of the Y-city Center for Managing Dementia in Gyunggi-do. The TOAP was designed for habituating patients and caregivers to the techniques acquired through goal activities and task and making it capable of being routinized regularly. The TOAP was applied to dementia patients and their cvaregivers twice a week for 7 weeks(one-time home visit, one-time phone inspection), a total of 14 times. Results: Significant differences among pre-test and post-test were found in the AMPS motor skills(1.10±1.14 and 1.34±1.2 respectively) scores, AMPS process skills(0.32±0.55 and 0.77±0.66 respectively) scores, ACL(3.86±0.65 and 4.17±0.64 respectively) scores, MMSE-KC(17.33±4.6 and 19.33±4.97 respectively) scores, GDS(11.73±6.87 and 8.53±7.09 respectively) scores, and caregiver burden(31.80±20.06 and 26.13±18.07 respectively) scores(p<0.05). A significant effect was confirmed from the TOAP which ADL, cognitive function, reduced patient's depression and caregiver burden(p<0.05). Conclusion: From the above results that a TOAP has an effect on the improvement of the ability to ADL, cognitive function and reduced depression and caregiver burden of dementia patients living in community. The present author hopes that, in the future, more diverse community based on tailored occupational activity programs will be developed to improve the functions of dementia patients living in community.

Associations Between Heart Rate Variability and Symptom Severity in Patients With Somatic Symptom Disorder (신체 증상 장애 환자의 심박변이도와 증상 심각도의 연관성)

  • Eunhwan Kim;Hesun Kim;Jinsil Ham;Joonbeom Kim;Jooyoung Oh
    • Korean Journal of Psychosomatic Medicine
    • /
    • v.31 no.2
    • /
    • pp.108-117
    • /
    • 2023
  • Objectives : Somatic symptom disorder (SSD) is characterized by the manifestation of a variety of physical symptoms, but little is known about differences in autonomic nervous system activity according to symptom severity, especially within patient groups. In this study, we examined differences in heart rate variability (HRV) across symptom severity in a group of SSD patients to analyze a representative marker of autonomic nervous system changes by symptoms severity. Methods : Medical records were retrospectively reviewed for patients who were diagnosed with SSD based on DSM-5 from September 18, 2020 to October 29, 2021. We applied inverse probability of treatment weighting (IPTW) methods to generate more homogeneous comparisons in HRV parameters by correcting for selection biases due to sociodemographic and clinical characteristic differences between groups. Results : There were statistically significant correlations between the somatic symptom severity and LF (nu), HF (nu), LF/HF, as well as SD1/SD2 and Alpha1/Alpha2. After IPTW estimation, the mild to moderate group was corrected to 27 (53.0%) and the severe group to 24 (47.0%), and homogeneity was achieved as the differences in demographic and clinical characteristics were not significant. The analysis of inverse probability weighted regression adjustment model showed that the severe group was associated with significantly lower RMSSD (β=-0.70, p=0.003) and pNN20 (β=-1.04, p=0.019) in the time domain and higher LF (nu) (β=0.29, p<0.001), lower HF (nu) (β=-0.29, p<0.001), higher LF/HF (β=1.41, p=0.001), and in the nonlinear domain, significant differences were tested for SampEn15 (β=-0.35, p=0.014), SD1/SD2 (β=-0.68, p<0.001), and Alpha1/Alpha2 (ß=0.43, p=0.001). Conclusions : These results suggest that differences in HRV parameters by SSD severity were showed in the time, frequency and nonlinear domains, specific parameters demonstrating significantly higher sympathetic nerve activity and reduced ability of the parasympathetic nervous system in SSD patients with severe symptoms.

Development of a prototype simulator for dental education (치의학 교육을 위한 프로토타입 시뮬레이터의 개발)

  • Mi-El Kim;Jaehoon Sim;Aein Mon;Myung-Joo Kim;Young-Seok Park;Ho-Beom Kwon;Jaeheung Park
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.257-267
    • /
    • 2023
  • Purpose. The purpose of the study was to fabricate a prototype robotic simulator for dental education, to test whether it could simulate mandibular movements, and to assess the possibility of the stimulator responding to stimuli during dental practice. Materials and methods. A virtual simulator model was developed based on segmentation of the hard tissues using cone-beam computed tomography (CBCT) data. The simulator frame was 3D printed using polylactic acid (PLA) material, and dentiforms and silicone face skin were also inserted. Servo actuators were used to control the movements of the simulator, and the simulator's response to dental stimuli was created by pressure and water level sensors. A water level test was performed to determine the specific threshold of the water level sensor. The mandibular movements and mandibular range of motion of the simulator were tested through computer simulation and the actual model. Results. The prototype robotic simulator consisted of an operational unit, an upper body with an electric device, a head with a temporomandibular joint (TMJ) and dentiforms. The TMJ of the simulator was capable of driving two degrees of freedom, implementing rotational and translational movements. In the water level test, the specific threshold of the water level sensor was 10.35 ml. The mandibular range of motion of the simulator was 50 mm in both computer simulation and the actual model. Conclusion. Although further advancements are still required to improve its efficiency and stability, the upper-body prototype simulator has the potential to be useful in dental practice education.

The Correction Effect of Motion Artifacts in PET/CT Image using System (PET/CT 검사 시 움직임 보정 기법의 유용성 평가)

  • Yeong-Hak Jo;Se-Jong Yoo;Seok-Hwan Bae;Jong-Ryul Seon;Seong-Ho Kim;Won-Jeong Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.1
    • /
    • pp.45-52
    • /
    • 2024
  • In this study, an AI-based algorithm was developed to prevent image quality deterioration and reading errors due to patient movement in PET/CT examinations that use radioisotopes in medical institutions to test cancer and other diseases. Using the Mothion Free software developed using, we checked the degree of correction of movement due to breathing, evaluated its usefulness, and conducted a study for clinical application. The experimental method was to use an RPM Phantom to inject the radioisotope 18F-FDG into a vacuum vial and a sphere of a NEMA IEC body Phantom of different sizes, and to produce images by directing the movement of the radioisotope into a moving lesion during respiration. The vacuum vial had different degrees of movement at different positions, and the spheres of the NEMA IEC body Phantom of different sizes produced different sizes of lesions. Through the acquired images, the lesion volume, maximum SUV, and average SUV were each measured to quantitatively evaluate the degree of motion correction by Motion Free. The average SUV of vacuum vial A, with a large degree of movement, was reduced by 23.36 %, and the error rate of vacuum vial B, with a small degree of movement, was reduced by 29.3 %. The average SUV error rate at the sphere 37mm and 22mm of the NEMA IEC body Phantom was reduced by 29.3 % and 26.51 %, respectively. The average error rate of the four measurements from which the error rate was calculated decreased by 30.03 %, indicating a more accurate average SUV value. In this study, only two-dimensional movements could be produced, so in order to obtain more accurate data, a Phantom that can embody the actual breathing movement of the human body was used, and if the diversity of the range of movement was configured, a more accurate evaluation of usability could be made.

Evaluation of the effect of a Position Error of a Customized Si-Bolus Produced using a 3D-Printer: Cervical Cancer Radiation Treatment (3D 프린터를 이용하여 제작한 맞춤형 Si-Bolus의 위치 오차 효과 평가: 자궁경부암 방사선 치료)

  • Seong Pyo Hong;Ji Oh Jeong;Seung Jae Lee;Byung Jin Choi;Chung Mo Kim;Soo Il Jung;Yun Sung Shin
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.35
    • /
    • pp.7-13
    • /
    • 2023
  • Purpose: In this study, we evaluated the effect of using a customized bolus on dose delivery in the treatment plan when cervical cancer protruded out of the body along with the uterus and evaluated reproducibility in patient set-up. Materials & Methods: The treatment plan used the Eclipse Treatment Planning System (Version 15.5.0, Varian, USA) and the treatment machine was VitalBeam (Varian Medical Systems, USA). The radiotherapy technique used 6 MV energy in the AP/PA direction with 3D-CRT. The prescribed dose is 1.8 Gy/fx and the total dose is 50.4 Gy/28 fx. Semiflex TM31010 (PTW, Germany) was used as the ion chamber, and the dose distribution was analyzed and evaluated by comparing the planned and measured dose according to each position movement and the tumor center dose. The first measurement was performed at the center by applying a customized bolus to the phantom, and the measurement was performed while moving in the range of -2 cm to +2 cm in the X, Y, and Z directions from the center assuming a positional error. It was measured at intervals of 0.5 cm, the Y-axis direction was measured up to ±3 cm, and the situation in which Bolus was set-up incorrectly was also measured. The measured doses were compared based on doses corrected to CT Hounsfield Unit (HU) 240 of silicon instead of the phantom's air cavity. Result: The treatment dose distribution was uniform when the customized bolus was used, and there was no significant difference between the prescribed dose and the actual measured value even when positional errors occurred. It was confirmed that the existing sheet-type bolus is difficult to compensate for irregularly shaped tumors protruding outside the body, but customized Bolus is found to be useful in delivering treatment doses uniformly.

  • PDF

Cases and Legal Issues For 119paramedics in Mental Emergency Situations (정신응급상황에서 119구급대원 대응사례와 법적쟁점)

  • Young Pyo Hong
    • The Korean Society of Law and Medicine
    • /
    • v.25 no.1
    • /
    • pp.87-115
    • /
    • 2024
  • In Korea, exposure to stress has been accompanied by mental pain in the process of achieving many growth along with rapid development, various social problems, and the frequency of emergency hospitalization is increasing.. In the case of mentally ill patients, "unwanted hospitalization" is a problem, and police and 119 paramedics try to suppress the body of mentally ill patients, and many problems are exposed This is because the constituent requirements of the provisions of emergency hospitalization under the Mental Health and Welfare Act do not reflect reality, and each institution has a different position on one mentally ill person, and emergency hospitalization does not proceed smoothly or leads to friction between related organizations, and the safety of the mentally ill or others is not secured. Emergency hospitalization is defined as "a person who finds a person who is presumed to be mentally ill and is at high risk of harming his or her health or safety or others," and if the situation is so urgent that he or she cannot afford time to go through the hospitalization procedure to decide on his or her own hospitalization, he or she can request emergency hospitalization with the consent of a doctor and a police officer. In this case, 119 paramedics are escorted to a psychiatric institution. This provision of emergency hospitalization poses many problems in the process of transferring to psychiatric institutions. If a police officer or 119 paramedics in charge of practice use "physical force" during the emergency hospitalization process, side effects will inevitably occur, and professional negligence can be a problem. Specifically, when exercising physical force, the minimum necessary physical restraint based on laws and regulations and proportional principles is required, and the lack of the duty of care of 119 paramedics or police officers under the laws and regulations will eventually be resolved by applying other laws and regulations. Accordingly, it will be an opportunity for mentally ill patients to be transferred to psychiatric institutions in a safe environment by changing the subject of emergency hospitalization provisions under the Mental Health Welfare Act, defining and prescribing the use of physical protection guards as the enforcement regulations of the Mental Health Act, setting the duty of care for 119 paramedics and police officers, and creating an environment for transportation so that mentally ill patients can be treated safely.

Usefulness of Corticomedullary-Phase CT Urography in Patients with Suspected Acute Renal Colic Visiting the Emergency Department (응급실을 방문하는 급성신산통이 의심되는 환자에서 요로조영술 컴퓨터단층촬영의 피질-수질기의 유용성)

  • Seokyoung Lee;Yang Shin Park;Bitna Park;Jongmee Lee;Jae Woong Choi;Kyeong Ah Kim;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.4
    • /
    • pp.923-933
    • /
    • 2023
  • Purpose To evaluate the sensitivity of corticomedullary-phase imaging for detecting urinary stones in patients with renal colic who visited the emergency department. Materials and Methods This retrospective study included 253 patients with suspected renal colic from two tertiary hospitals in South Korea, who visited the emergency department and underwent CT urography. Two radiologists blinded to the clinical history independently reviewed the corticomedullary-phase images. The sensitivity for identifying urinary stones were evaluated for each reviewer. After the initial evaluation, the images were re-evaluated based on patient history. The sensitivity of re-evaluation were recorded. Results Of 253 patients, 150 (59%) had urinary stones. Among them, significant stones were observed in 138 patients (92%), and obstructive changes on CT in 124 patients (82.7%). For identifying significant urinary stones, the sensitivity was 98.6% (136/138) for both the reviewers. For identifying significant urinary stones with urinary obstruction, the sensitivity was 99.2% (123/124) for reviewer 1, and 100% (124/124) for reviewer 2. The sensitivity for identifying significant stones increased from 98.6% to 100% for reviewer 1, and from 98.6% to 99.3% for reviewer 2 in the re-evaluation session. Conclusion The corticomedullary-phase CT urography was sensitive for diagnosing urolithiasis in patients with acute renal colic who visited the emergency department.

Correlation Analysis between Fat Fraction and Bone Mineral Density Using the DIXON Method for Fat Dominant Tissue in Knee Joint MRI: A Preliminary Study (지방우세 딕슨기법을 이용한 슬관절 자기공명영상 지방신호분율과 골밀도 간의 상관관계 분석: 예비 연구)

  • Sung Hyun An;Kyu-Sung Kwack;Sunghoon Park;Jae Sung Yun;Bumhee Park;Ji Su Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.427-440
    • /
    • 2023
  • Purpose This study aimed to investigate the correlation between the fat signal fraction (FF) of the fat-dominant bone tissue of the knee joint, measured using the MRI Dixon method (DIXON) technique, and bone mineral density (BMD). Materials and Methods Among the patients who underwent knee DIXON imaging at our institute, we retrospectively analyzed 93 patients who also underwent dual energy X-ray absorptiometry within 1 year. The FFs of the distal femur metaphyseal (Fm) and proximal tibia metaphyseal (Tm) were calculated from the DIXON images, and the correlation between FF and BMD was analyzed. Patients were grouped based on BMD of lumbar spine (L), femoral neck (FN), and common femur (FT) respectively, and the Kruskal-Wallis H test was performed for FF. Results We identified a significant negative correlation between TmFF and FN-BMD in the entire patient group (r = -0.26, p < 0.05). In female patients, TmFF showed a negative correlation with FN-BMD, FT-BMD, and L-BMD (r = -0.38, 0.28 and -0.27, p < 0.05). In male patients, FmFF was negatively correlated with only FN-BMD and FT-BMD (r = -0.58 and -0.42, p < 0.05). There was a significant difference in the TmFF between female patients grouped by BMD (p < 0.05). In male patients, there was a significant difference in FmFF (p < 0.05). Conclusion Overall, we found that FF and BMD around the knee joints showed a negative correlation. This suggests the potential of FF measurement using DIXON for BMD screening.