• 제목/요약/키워드: Patient setup

검색결과 122건 처리시간 0.033초

Abdomen Immobilization with Air Injected Balloon Blanket

  • Suh, Ye-Lin;Yi, Byong-Yong;Ahn, Seung-Do;Lee, Sang-Wook;Kim, Jong-Hoon;Shin, Seung-Ai;Park, Eun-Kyung
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.100-102
    • /
    • 2002
  • The demand for a better immobilization device has been increased in the radiation oncology field. Especially, it is essential to have a reliable and practical immobilization tool for the whole body radiosurgery and the IMRT (intensity modulated radiation therapy). A useful method to immobilize the abdomen for the external beam radiation treatment is developed. The air-injected balloon blanket (AIBB) was designed as an immobilization device. As the air was injected into it, it pressed down the patient's abdomen and fixed the patient. The AIBB played a role not only to grab the patients' motion, but also to increase the patients' setup reproducibility. Patients' movements due to the respiration were reduced and the reconstruction could be maximized. The experimental results revealed that the AIBB could be used for the clinic.

  • PDF

Study on The Development of A New Whole Body Fame

  • Chung, Jin-Bum;Suh, Tae-Suk;Chung, Won-Kyun;Choe, Bo-Young;Lee, Hyoung-Koo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.136-137
    • /
    • 2002
  • We have been researching upgrade version of a stereotactic whole body frame, used for evaluating daily setup accuracy of the patient positioning during fractionated extra-cranial stereotactic radiotherapy. Currently, we are focusing on the development of a new stereotactic whole body frame, and then will handle organ movement produced by breathing at the next stage. MeV-Green is chosen for the best immobilizer possible and the epoxy board is for the frame with the dimension of 110 em in length, 50 cm in width in order to maximize transmission rate of the beam from lateral or posterior direction and to fit CT and PET scanners with an aperture of 55 cm at least. The key point of an upgraded stereotactic whole body frame will be set on the collision-free rotation of the gantry with the frame, and the development of the checking structure for the daily patient repositioning regarding internal target.

  • PDF

Feasibility Study of Patient Specific Quality Assurance Using Transit Dosimetry Based on Measurement with an Electronic Portal Imaging Device

  • Baek, Tae Seong;Chung, Eun Ji;Son, Jaeman;Yoon, Myonggeun
    • 한국의학물리학회지:의학물리
    • /
    • 제28권2호
    • /
    • pp.54-60
    • /
    • 2017
  • This study was designed to measure transit dose with an electronic portal imaging device (EPID) in eight patients treated with intensity modulated radiotherapy (IMRT), and to verify the accuracy of dose delivery to patients. The calculated dose map of the treatment planning system (TPS) was compared with the EPID based dose measured on the same plane with a gamma index method. The plan for each patient was verified prior to treatment with a diode array (MapCHECK) and portal dose image prediction (PDIP). To simulate possible patient positioning errors during treatment, outcomes were evaluated after an anthropomorphic phantom was displaced 5 and 10 mm in various directions. Based on 3%/3 mm criteria, the $mean{\pm}SD$ passing rates of MapCHECK, PDIP (pre-treatment QA) for 47 IMRT were $99.8{\pm}0.1%$, $99.0{\pm}0.7%$, and, respectively. Besides, passing rates using transit dosimetry was $90.0{\pm}1.5%$ for the same condition. Setup errors of 5 and 10 mm reduced the mean passing rates by 1.3% and 3.0% (inferior to superior), 2.2% and 4.3% (superior to inferior), 5.9% and 10.9% (left to right), and 8.9% and 16.3% (right to left), respectively. These findings suggest that the transit dose-based IMRT verification method using EPID, in which the transit dose from patients is compared with the dose map calculated from the TPS, may be useful in verifying various errors including setup and/or patient positioning error, inhomogeneity and target motions.

On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구 (Analyses of the Setup Errors using on Board Imager (OBI))

  • 김종덕;이행오;유재만;지동화;송주영
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.1-5
    • /
    • 2007
  • 목적: 방사선치료 시 OBI (on board imager) 시스템으로 환자 셋업 오차(set-up error)를 확인, 보정한 결과를 분석하여, 셋업 오차(set-up error)의 경향 및 원인을 살펴보고, 기존 필름과 EPID (electronic portal imaging device)를 사용한 방법에 비해 OBI의 정확성과 유용성에 대하여 알아보고자 한다. 대상 및 방법: 2006년 3월부터 2006년 5월까지 본원에 내원한 3차원 치료계획 환자 130명을 대상으로 주 1회 이상 OBI를 이용하여 치료전 셋업 영상의 분석을 시행하였다. 직각으로 획득한 2개의 영상을 모의 치료실에서 획득한 기준영상(reference image)과 합성(Fusion) 후 분석을 하였다. 분석 후 Vertical, Lateral, Longitudinal 방향으로 변위(Shift)거리를 측정하여 오차를 분석했다. 또한, 주요 부위별, 방향별로 구분하여 셋업 오차(set-up error) 요인들을 비교, 평가하였다. 결과: OBI를 적용하여 분석한 환자 41.5%에서 변위가 없이 Setup이 정확하였고, 52.3%에서 $1{\sim}5mm$정도의 오차가 존재하였다. 5 mm오차 이상인 환자도 6.1%가 확인되었다. 5 mm이상의 오차를 보인 환자들은 치료실내에서 확인한 결과 환자의 움직임이나 모의치료 자세와의 차이에서 오는 결과임을 알 수 있었다. 또한, 3 mm이상의 오차 경향이 3번 이상 지속될 경우에는 모의 치료실로 이동하여 보정후 치료를 시행하였다. 결론: 치료 전 2인의 근무자가 셋업을 정확히 하고 3면의 레이저와 조사야를 확인하였지만, 직각의 KV 영상으로 분석한 결과 셋업 오차가 발생할 수 있음을 확인하였다. 기존의 EPID에 의한 MV 영상은 낮은 영상의 특성과 환자의 피폭선량 증가라는 단점이 존재하지만, 본 연구에서 분석한 OBI는 모의 치료와 같은 높은 화질의 영상으로 셋업 오차의 정확한 계산과 객관적인 셋업 보정이 가능하여 영상유도 방사선치료의 정확도와 유용성을 입증할 수 있었다.

  • PDF

Maxillary molar derotation and distalization by using a nickel-titanium wire fabricated on a setup model

  • Jung, Jong Moon;Wi, Young Joo;Koo, Hyun Mo;Kim, Min Ji;Chun, Youn Sic
    • 대한치과교정학회지
    • /
    • 제47권4호
    • /
    • pp.268-274
    • /
    • 2017
  • The purpose of this article is to introduce a simple appliance that uses a setup model and a nickel-titanium (Ni-Ti) wire for correcting the mesial rotation and drift of the permanent maxillary first molar. The technique involves bonding a Ni-Ti wire to the proper position of the target tooth on a setup model, followed by the fabrication of the transfer cap for indirect bonding and its transfer to the patient's teeth. This appliance causes less discomfort and provides better oral hygiene for the patients than do conventional appliances such as the bracket, pendulum, and distal jet. The treatment time is also shorter with the new appliance than with full-fixed appliances. Moreover, the applicability of the new appliance can be expanded to many cases by using screws or splinting with adjacent teeth to improve anchorage.

환자 SET-UP ERROR에 따른 선량분포와 DVH 변화 분석 (The dose distribution and DVH change analysis wing to effect of the patient setup error)

  • 김경태;주상규;안재홍;박영환
    • 대한방사선치료학회지
    • /
    • 제16권2호
    • /
    • pp.81-89
    • /
    • 2004
  • 목적 : 방사선 치료에서 환자와 근무자에 의한 setup error등은 치료성적이 결정될 수 있는 중요한 요인이라고 볼 수 있다. 이에 환자와 근무자에 의한 SET-UP ERROR가 환자치료에 미치는 영향에 대하여 비교 분석하고자 한다. 대상 및 방법 : 실험은 human phantom을 이용하여 C-T scan시 Left방향의 Lateral Level을 0mm, 3mm, 5mm, 7mm, 10mm, 15mm, 20mm로 변화시켜 SET-UP ERROR를 유발하였고, 각각에 대하여 C-T scan을 시행하였고, SET-UP ERROR가 유발된 각각의 C-T image를 얻어 RTP장비를 이용하여 임상에서 많이 사용되는 plan을 사용하여 7개의 C-T image에 각각의 plan-대향이문조사plan, Box-4문조사plan, 3Dimension plan-3개를 시행하여 총 21개의 plan을 실시하였다. (CTV+1cm margin, CTV+0.5cm margin, CTV+0.3cm margin = PTV) 이렇게 얻어진 plan을 이용하여 SET-UP ERROR가 유발이 안된 0mm image의 plan 3개와 SET-UP ERROR가 있는 6개 image의 총 18개의 plan을 대향이문조사plan, Box4문조사plan, 3Dimension plan으로 나누어 선량분포와 DVH를 이용하여 비교 분석하였다. 결과 : SET-UP ERROR를 유발시킨 3mm, 5mm, 7mm C-T image에서는 대향이문조사plan을 제외하고는 모든 plan에서 충분히 치료에 영향을 미칠만한 변화가 나타났으며, Box4문조사plan에서는 SET-UP ERROR에 의한 CTV가 Field 밖으로 빠짐으로 선량분포와 DVH가 나빠지는 현상이 나타났다. 결론 : 환자의 움직임, CTV 3차원형태, CTV margin등이 치료에 영향을 미친다. 이러한 영향을 줄이기 위해서는 환자의 긴장감과 움직임을 줄일 수 있는 환자교육과 정확한 환자setup능력이 치료의 승패를 좌우한다고 생각된다. 또한 재현성과 움직임을 줄일 수 있는 accessory 개발과 보급이 중요하다.

  • PDF

전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가 (Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy)

  • 박성용;임승규;시명근;이지해;김종열;조은주
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.75-81
    • /
    • 2017
  • 목 적: 전립선암 환자에 대한 비침습적이고 피폭선량에 대한 부담이 없는 초음파를 이용한 영상유도방사선치료의 Setup 오차 분석을 통해 치료의 재현성을 평가해 보고자 한다. 대상 및 방법: 치료가 종료된 전립선암 환자 26명의 1,105영상에 대하여 앞-뒤(anterior-posterior, AP), 좌-우(right-left, RL), 위-아래(superior-inferior, SI) 방향의 Setup 오차에 대해 평균, 표준편차와 3D-error을 분석하였다. 또한 오차범위 0-1 mm, 1-3 mm, 3-5 mm, 5 mm 이상에 대한 각 오차 빈도수(frequency, %) 분석을 통하여 AP, RL, SI 방향에 대한 방향성을 확인 하였다. 결 과: Setup 오차는 AP, RL, SI 방향에 대하여 평균과 표준편차는 $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$, $2.01{\pm}1.40mm$였다. 3D-error는 평균 $3.63{\pm}1.63mm$였다. 각 방향에 대한 Setup 오차값의 빈도(frequency, %)는 AP 방향에 대한 오차범위 0-1 mm에서 29 %, 1-3 mm에서 50.2 %, 3-5 mm에서 19.6 %, 5 mm 이상에서 1.3 %였다. RL 방향에 대하여 오차범위 0-1 mm에서 31.3 %, 1-3 mm에서는 52.5 %, 3-5 mm에서는 15.8 %, 5 mm 이상에서 0.5 %였다. 마지막으로 SI 방향에 대한 오차범위 0-1 mm에서 26.3 %, 1-3 mm에서 50.2 %, 3-5 mm에서 22.4 %, 5 mm 이상에서 1.1 %였다. 결 론: Setup error는 SI 방향에서 $2.01{\pm}1.40mm$로 가장 컸으며 오차 빈도는 모든 방향에서 50 % 이상 오차 범위 1-3 mm에 들어온 것으로 확인되었다. $Clarity^{TM}$ Auto scan을 이용한 초음파영상유도 방사선치료는 치료 전에 방광의 전처치 상태, target의 구조 등을 관찰이 가능하고, 치료 중 target의 움직임을 실시간으로 monitoring하여 빠른 repositioning이 가능하다. 결과적으로 초음파를 이용한 실시간 영상유도방사선치료는 치료의 재현성을 높일 수 있을 것으로 사료된다.

  • PDF

무선 CCTV 시스템을 이용한 환자 고정 보조기술의 개발 (Patient Setup Aid with Wireless CCTV System in Radiation Therapy)

  • 박양균;하성환;예성준;조웅;박종민;박석원;허순녕
    • Radiation Oncology Journal
    • /
    • 제24권4호
    • /
    • pp.300-308
    • /
    • 2006
  • 목 적: 본 연구에서는 선형가속기 갠트리 헤드에 부착된 무선 CCTV 카메라를 이용한 영상처리를 통하여 환자 고정과 치료에 있어서의 정확성과 재현성 향상 방안을 개발하고자 하였다. 대상 및 방법: 선형가속기의 유사-빔 방향상(semi-beams eye view, semi-BEV)을 얻기 위하여 무선 CCTV 모듈을 자체 제작된 아크릴 어플리케이터를 이용하여 갠트리 헤드에 부착하였다. CCTV 카메라의 영상은 2.4 GHz의 고주파를 통해 치료실 벽면의 수신기로 전송된다. 선형가속기 작동 시 발생하는 무선 주파수에 의한 간섭현상(RF interference)과 누설 방사선으로 영상에 잡음이 발생하는데, 구리 호일로 카메라를 차폐하고 미디안 필터링과 같은 영상처리 기법을 이용하여 이러한 잡음을 최소화할 수 있었다. 스테레오 정합 기법과 Gauss-Newton 최적화 방법론을 기반으로 자체 제작된 소프트웨어를 통해, 환자의 고정 상태를 나타내는 3차원적 위치, 이동, 회전 정도를 정량적으로 평가하였다. 시스템의 정확도를 평가하기 위하여 팬톰 실험을 수행하였다. 또, 환자 호흡에 대한 실시간 영상분석을 통해 호흡 동기 시스템(respiratory gating system)을 구현하기 위한 방법론을 개발하였다. 결 과: 구리 호일 차폐와 영상처리를 통해 잡음을 80% 이상 줄일 수 있었다. 3차원 위치정보의 오차는 팬톰 실험을 통해 $1.5{\pm}0.7\;mm$로 나타났고, 이동 및 회전량에 대한 오차는 각각, 1 mm, $1^{\circ}$ 미만으로 나타났다. 환자 호흡에 따른 호흡 동기 시스템을 구현한 결과, 0.2초의 오차 범위 내에서 실시간 모니터링이 가능한 것으로 나타났다. 결 론: 선형가속기에 부착된 CCTV를 이용한 환자 고정 보조기술은 기존의 높은 비용을 필요로 하는 타 IGRT 기법에 비하여 설치와 이용이 간편하다. 시스템이 선형가속기와 근접해 있기 때문에 야기되는 문제점은 본 연구에서 제시된 방법을 통해 해결될 수 있었다. 시스템의 정확도를 평가해 볼 때, 임상적으로 적용이 가능할 것으로 판단된다.

토모다이렉트 3D-CRT을 이용한 유방암 환자의 회전 오차 (Rotation Errors of Breast Cancer on 3D-CRT in TomoDirect)

  • 정재홍;조광환;문성권;배선현;민철기;김은석;여승구;최진호;정주영;최보영;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제26권1호
    • /
    • pp.6-11
    • /
    • 2015
  • 본 연구의 목적은 토모다이렉트 3D-CRT (TD 3D-CRT)을 이용한 유방암 방사선치료에서 회전축(roll, pitch, and yaw) 오차를 분석하고 자 하였다. TD-3DCRT로 치료가 종료된 유방암 환자 총 20명을 선정하였고, 총 80회의 MVCT 영상을 바탕으로 시스템(systematic), 임의(random) 오류를 포함한 환자위치잡이 오차(patient setup errors)와 치료 여백(treatment margin, mm)을 후향적으로 분석하였다. 또한, 각 환자에 대한 회전축 오차 분석은 자동영상정합(automatic image registration)을 이용하였다. X, Y, Z 방향에 대한 치료여백은 각각 4.2 mm, 6.2 mm, 6.4 mm였다. 회전축 오차에 대한 평균 각도(degree)는 roll, pitch, yaw가 각각 0.3도, 0.5도, 0.1도였고, 시스템과 임의 오류는 모두 1도 이내였다. 전반적으로 환자 위치잡이 오차는 Y와 Z방향에서 X에 비하여 높게 나타났다. 본 연구에서 회전축 오차 각도가 2도 이내는 roll, pitch, yaw에서 각각 95.1%, 98.8%, 97.5% 분포였다. 그러나, 치료영역의 길이가 길어짐에 따라 치료 중심지점을 기준으로 상부와 하부의 가장자리(Edge)가 틀어지게(Twisted)될 가능성이 높아질 수 있다. 따라서 치료의 정확성과 재현성을 위하여 각 환자의 특성을 고려하고, 회전축 오차를 주기적으로 확인할 필요가 있다.

디지털 기술을 이용한 선수술 악교정치료 (Application of CAD-CAM technology to surgery-first orthognathic approach)

  • 김윤지;길병규;류재준
    • 대한치과의사협회지
    • /
    • 제56권11호
    • /
    • pp.622-630
    • /
    • 2018
  • For successful surgery-first approach, accurate prediction of skeletal and dental changes following orthognathic surgery is essential. With recent development of digital technology using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, attempts to provide more predictable orthodontic/orthognathic treatment have been made through 3D virtual surgery and digital tooth setup. A clinical protocol for the surgery-first orthognathic approach using virtual surgery is proposed. A case of skeletal Class III patient with facial asymmetry treated by the surgery-first approach using digital setup and virtual surgery is presented. Advantages and limitations of applying CAD/CAM technology to orthognathic surgery are discussed.

  • PDF