• 제목/요약/키워드: Patient radiation exposure

검색결과 379건 처리시간 0.024초

세기조절방사선치료의 정도관리 (Quality Assurance in Intensity Modulated Radiation Theray)

  • 김성규
    • Journal of Yeungnam Medical Science
    • /
    • 제25권2호
    • /
    • pp.85-91
    • /
    • 2008
  • Intensity-modulated radiation therapy (IMRT) is believed to be one of the best radiation treatment techniques. IMRT is able to deliver fatal doses of radiation to the tumor region with minimal exposure of critical organs. It is essential to have a comprehensive quality assurance program to assure precision and accuracy in treatment, due to the character of IMRT. We applied quality assurance technique to the Eclipse treatment planning system and sought to determine its effectiveness in patient treatment planning. An acrylic phantom, film, and an ionization chamber were used in this study.

  • PDF

CT선량지표의 원리와 선량감소 방안에 관한 연구 (Basic Principles of CT Dose Index and Understanding of CT Parameter for Dose Reduction Technique)

  • 김정수;권순무;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권1호
    • /
    • pp.51-61
    • /
    • 2015
  • 모든 방사선 검사는 검사를 결정하고 실행하는 과정에서 정당성이 확보되어야하고 피폭선량과 영상의 화질에 대한 최적화가 이루어져야 할 뿐만 아니라 ALARA의 원칙에 따라 최소의 방사선을 사용하여 최적의 임상 정보를 얻을 수 있어야 한다. CT 검사는 방사선 검사 중에서 많은 피폭을 환자에게 조사하는 검사이다. 특히 방사선 민감도가 높은 소아 환자의 CT 검사 있어서는 특별한 주의가 필요하다. 임상에서 CT선량에 대한 정확한 이해와 정보는 환자에게 불필요한 방사선 피폭을 줄이고 안전한 검사를 제공하기 위해 절대적으로 필요하다. 이에 본 연구에서는 여러 선행 연구의 고찰을 통하여 CT의 피폭선량에 대한 개념을 확인하고 CT장치의 선량 저감화를 위한 각 파라미터의 이해와 American Association of Physicists in Medicine (AAPM)report 204에서 소개하고 있는 환자의 사이즈에 따른 피폭선량의 보정방법인 Size-Specific Dose Estimates(SSDE)와 XR 25의 개념을 이해하고자 한다.

일반엑스선 검사 시 위치 잡이의 중요성: 흉부엑스선 검사 중심으로 (The Importance of Positioning in General X-ray Examination: Based on Chest PA X-ray)

  • 조평곤
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권3호
    • /
    • pp.249-254
    • /
    • 2022
  • The purpose of this study was to examine the importance of proper positioning in chest PA X-ray examination. As a study method, this author searched for and analyzed materials related to chest PA X-ray examination from theses and books that had been published previously to understand the importance of proper positioning in chest PA X-ray examination. Generally, one of the examinations frequently done in most of the hospitals is chest PA X-ray examination. Also, in any kinds of X-ray examination, proper positioning is the most fundamental and definite way to provide accurate information about the patient. Poor positioning in chest PA X-ray examination may jeopardize the diagnosis and treatment, increase social cost due to examination needed to be done additionally, and generate additional radiation exposure unnecessarily above all. In conclusion, it is expected that proper positioning in chest PA X-ray examination will exert positive effects such as the provision of accurate information about the patient, prevention of misdiagnosis, reduction in social cost, and lastly decrease in radiation exposure.

영.유아의 배뇨성 방광-요도 조영술 및 방사선 공기 주입 정복술시 피폭선량 경감을 위한 fluorograb의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography(VCUG))

  • 김상태;최지원
    • 한국콘텐츠학회논문지
    • /
    • 제9권12호
    • /
    • pp.385-390
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성 방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 줄이기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행 시 영 유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행 시 spot 촬영을 대체할 수 있을 것으로 생각한다.

영아/유아의 공기 주입 정복술 및 방사선 배뇨성 방광요도 조영술시 피폭 선량 경감을 위한 FluroGrab의 유용성 (The Efficacy of Fluorograb for Paediatric Patients Dose Reduction during Pneumatic Reduction and Voiding Cystourethrography (VCUG))

  • 김상태;최지원;한태종
    • 한국콘텐츠학회:학술대회논문집
    • /
    • 한국콘텐츠학회 2009년도 춘계 종합학술대회 논문집
    • /
    • pp.1167-1172
    • /
    • 2009
  • 공기주입 정복술(pneumatic reduction) 및 방사선 배뇨성방광요도 조영술(Voiding Cystourethrography: 이하 VCUG)는 일반적으로 영,유아에게서 행해지는데 이들 검사는 투시 촬영과 spot 촬영으로 이루어지며 이때 투시촬영으로 인한 방사선 피폭은 불가피한 것이나 spot 촬영으로 인한 피폭은 투시 화면상의 관심영상을 capture하는 기능인 fluorograb을 이용하여 제거할 수 있다. fluorograb은 spot영상과 비슷한 진단가치를 지니고 있으며 최근 사용되고 있는 대부분의 투시촬영장비에서 지원되는 기능이지만 다수의 의사 및 방사선사는 이 기능을 인지하지 못하고 있거나 인지하고는 있으나 습관적으로 spot 촬영을 행하고 있는 실정이다. 이는 방사선에 매우 민감한 연령대에 속한 영.유아에서 적게는 10장 미만에서 많게는 20장 이상을 spot 촬영하게 되는 공기주입 정복술 및 VCUG에서 그 영향이 적지 않다 하겠다. 따라서 공기주입 정복술 및 VCUG 시행시 spot 촬영으로 인한 영.유아의 피폭을 제거하기 위한 방법으로 spot 촬영을 대신한 fluorograb을 제안하며 이로 인한 기존의 공기주입 정복술 및 VCUG 시행시 영.유아의 피폭선량 경감 효과를 증명하고자 하였다. 공기주입 정복술 및 VCUG 의 진단에 fluorograb은 spot 촬영과 비슷한 수준의 정확도를 보이는 안전하고 유용한 방법이여 공기주입 정복술 및 VCUG 시행시 spot 촬영을 대체할 수 있을 것으로 생각한다.

  • PDF

구내 방사선발생기의 선량 분포측정을 통한 필름유지기구(XCP-DS FIT)의 피폭선량감소에 대한 유용성 (Utilization-Focused Reduction of Radiation Exposure with XCP-DS FIT Sensor Holder by Measuring Dose of Dental X-ray Generator)

  • 이경희
    • 한국방사선학회논문지
    • /
    • 제6권6호
    • /
    • pp.465-471
    • /
    • 2012
  • 본 연구에서는 ALOKA PDM-117(X-ray 측정용 선량계)선량계를 이용하여 구내방사선 촬영기에서 발생하는 방사선에 대하여 거리의 변화에 따른 선량분포를 3차원으로 측정하였다. 구내 방사선촬영에 있어서 XCP 필름 유지기구(XCP-DS FIT)를 사용하여 영상을 얻는 경우 방사선의 선량 분포는 변할 수 있고 이것은 방사선영상과 환자피폭에 영향을 미치게 된다. 따라서 위치에 따른 선량을 표준화하여 XCP 필름 유지기구 사용 유무에 따른 선량과의 관계를 알아볼 필요성이 있다. 본 연구에서는 측정된 3차원 선량분포를 통하여 등각촬영시 얻을 수 있는 최적의 영상과 동일한 선량을 얻기 위한 조사시간과 거리와의 관계 및 선량분포의 모서리 퍼짐 현상에 대한 결과를 정량적으로 측정하였다. 거리가 증가함에 따라 중심 선량은 감소하였지만 조사통 가장자리 부분의 방사선 퍼짐은 증가하는 경향을 보였다. 이것은 XCP 필름 유지기구를 사용하는 경우에 선속 가장자리 부분에서 방사선의 선량이 퍼지는 경향을 보이기 때문이므로 환자의 병소이외의 부분에 대한 피폭에 주의를 기울여야 함을 정량적으로 확인 하였다. 본 연구의 결과는 품질 좋은 치아영상을 얻고, 환자의 피폭선량을 줄이는데 매우 유용하게 사용되어 질 수 있을 것으로 사료된다.

자동노출제어장치를 이용한 비정질 실리콘 평판형 검출기에서 격자의 조건에 따른 환자선량 변화와 촬영 거리의 변화가 검출기 획득선량에 미치는 영향 (The Influence of the Change of Patient Radiation Exposure Dose Distribution on the Grid Condition and Detector Acquisition Dose on the Exposure Distance in the Use of Amorphous Silicon Thin Film Transistor Detector with AEC)

  • 윤석환;최준구;한동균
    • 대한디지털의료영상학회논문지
    • /
    • 제9권2호
    • /
    • pp.23-30
    • /
    • 2007
  • This study attempts to propose an appropriate method of using digital medical imaging equipments, by studying the effects of automatic exposure control(AEC), grid ratio and the change of radiography distance on the patient dose and detertor acquisition dose during the procedure of acquiring image through a digital medical imaging detector. The change of dose following the change of grid ratio's exposure and radiography distance was measured, by using an abdominal phantom organized with tissue equivalent materials in an amorphous silicon thin film transistor detecter installed with AWC. The case to use grid ratio 12 : 1, focal distance 180cm to radiography distance 110cm in AEC, the patient dose increased rather when we used grid ration 10 : 1, focal distance 110cm. When AEC was not used,the dose necessary for image acquisition decreased as the grid ratio became higher and the distance became further. but detector acquisition dose was not reduced when in applied AEC. When purchasing digiral medical imaging equipments, optional items such as AEC and grid shall be accurately selected to satisfy the use of the equipments. Radiography error made by radiation technologist and unnenessary patient dose can be reduced by selecting equipments with a radiography distance marker equipment when it did not apply AEC. These equipments can also be helpful in maintaining high imaging quality, one of the merits of digital detectors.

  • PDF

18-FDG EXTERNAL RADIATION DOSE RATES IN DIFFERENT BODY REGIONS OF PET-MRI PATIENTS

  • Han, Eunok;Kim, Ssangtae
    • Journal of Radiation Protection and Research
    • /
    • 제38권3호
    • /
    • pp.157-165
    • /
    • 2013
  • To determine the factors affecting the external radiation dose rates of patients undergoing PET-MRI examinations and to assess the trends of these differences, we measured the changes in the dose rates of $^{18}F$-FDG during a set period of time for each body region. Consistent with theoretical predictions, the dose rate decreased over time in patients undergoing PET-MRI examinations. Furthermore, immediately after the $^{18}F$-FDG injection, the dose rate in the chest region was the highest, followed by the abdominal region, the head region, and the foot region. The dose rate decreased drastically as time passed, by 2.47-fold, from $339.23{\pm}74.70mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection to $102.71{\pm}26.17mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. In the foot region, there were no significant changes over time, from $32.05{\pm}20.23mSv\;h^{-1}$ ($6.73{\pm}5.79$ min) at the time point immediately after the $^{18}F$-FDG injection, to $23.89{\pm}9.14mSv\;h^{-1}$ ($136.11{\pm}25.64$ min) after the examination. The dose rate is dependent on the individual characteristics of the patient, and differed depending on the body region and time point. However, the dose rates were higher in patients who had a lower body weight, shorter stature, fewer urinations, lower fluid intake, and history of diabetes mellitus. To decrease radiation exposure, it is difficult or impossible to change factors inherent to the patient, such as sex, age, height, body weight, obesity, and history of diabetes mellitus. However, factors which can be changed, such as the $^{18}F$-FDG dose, fasting time, fluid intake, number of urinations, and contrast agent dose can be controlled to minimize the external radiation exposure of the patient.

Common positioning errors in panoramic radiography: A review

  • Rondon, Rafael Henrique Nunes;Pereira, Yamba Carla Lara;do Nascimento, Glauce Crivelaro
    • Imaging Science in Dentistry
    • /
    • 제44권1호
    • /
    • pp.1-6
    • /
    • 2014
  • Professionals performing radiographic examinations are responsible for maintaining optimal image quality for accurate diagnoses. These professionals must competently execute techniques such as film manipulation and processing to minimize patient exposure to radiation. Improper performance by the professional and/or patient may result in a radiographic image of unsatisfactory quality that can also lead to a misdiagnosis and the development of an inadequate treatment plan. Currently, the most commonly performed extraoral examination is panoramic radiography. The invention of panoramic radiography has resulted in improvements in image quality with decreased exposure to radiation and at a low cost. However, this technique requires careful, accurate positioning of the patient's teeth and surrounding maxillofacial bone structure within the focal trough. Therefore, we reviewed the literature for the most common types of positioning errors in panoramic radiography to suggest the correct techniques. We would also discuss how to determine if the most common positioning errors occurred in panoramic radiography, such as in the positioning of the patient's head, tongue, chin, or body.

방사선과 대학생이 방사선피폭관리에 대한 지식, 태도, 행위에 관한 연구 (A Study on Perceptions by College Students of Radiology about the Knowledge, Attitudes and Behaviors of Radiation Exposure Management)

  • 여진동;고인호;김혜숙
    • 한국방사선학회논문지
    • /
    • 제9권2호
    • /
    • pp.79-99
    • /
    • 2015
  • 본 연구의 조사대상은 대구, 경북지역에 소재한 대학교에 재학 중인 방사선과를 전공하는 대학생을 조사대상으로 2014년 2월 3일부터 2월21일까지 설문조사를 실시하여 다음과 같은 결과를 얻었다. 1. 방사선피폭관리에 대한 지식에 대해서는 'X선의 차폐는 납이나 콘크리트로 된 물질이 가능 하다', '인체에서 생식선은 방사선에 매우 민감한 부분이다' 문항에서 가장 높은 점수를 보였고, '직업상 피폭선량은 규정된 5년간에 대해 평균하여 연간 20 mSv를 넘을 수 없다'는 방사선피폭관리에 대한 지식이 가장 낮은 점수를 보였다. 2. 방사선피폭관리에 대한 태도에 대해서는 '방사선피폭과 관련하여 정기적인 건강진단을 받아야한다'. '방사선 조사지역에서 작업 시 방호복을 착용해야한다'는 문항에서 가장 높은 태도 수준을 보였고, '방사선장치의 선량보정 (Calibration)을 위한 선량측정을 정기적으로 해야 한다'는 방사선피폭관리에 대한 태도에서 가장 낮은 태도수준을 보였다. 3. 방사선피폭관리에 대한 행위에 대해서는 '방사선 조사 시 방어벽(판) 뒤에서 작업을 한 다'. '방사선피폭관리에 관한 교육을 정기적으로 받는 다'는 문항에서 가장 높은 행위 수준을 보였고, '근무지의 방사선 관련 장비가 순조로운 작업 상태로 되어 있는가를 사용 전 점점(Check)한다'는 가장 낮은 행위 수준을 보였다.