Background: The purpose of this prospective randomized single-blind clinical trial was to evaluate the effect of tilting the head on the anesthetic efficacy of inferior alveolar nerve block (IANB) in patients with symptomatic irreversible pulpitis. Methods: Ninety-two patients were divided into two groups: the first group received IANB and the head was tilted in the direction of the block for 15 min, whereas the second group received IANB and the head was tilted to the opposite side. Access cavity preparation was initiated after 15 min. Success was defined as no pain or faint/weak/mild pain during endodontic access preparation and instrumentation. The anesthetic success rates were analyzed by Pearson chi-square test at 5% significance levels. Results: The same side position and opposite side position yielded 41% and 30% anesthetic success rates, respectively; there was no significant difference between the two sides. Conclusions: Relative head position has no effect on the anesthetic success rate of IANB.
Kim Seung-June;Kwon Kung-Rock;Lee Sung-Bok;Woo Yi-Hyung;Choi Dae-Gyun;Choi Boo-Byung
대한치과보철학회지
/
제39권3호
/
pp.306-312
/
2001
Achieving an aesthetic implant-supported restoration in the single tooth missing case can be challenging when the implant site is in e anterior region. The objective of this report is to focus on presurgical evaluation of implant site and systematic development of related prosthetic modalities. An accurate diagnostic evaluation, a systematically developed pesurgical plan, and knowledge and clinical skill of the various related therapeutic modalities are indispensible. Collection of patient's information, appropriate abutment selection, soft tissue contour, implant axis, and occlusion need to be discussed for aesthetic clinical outcome. For aesthetic restoration, such as surgical guide stent for precise implant positioning customized provisional restoration for development of optimal periimplant soft tissue contours, and fabrication customized abutment (mesiostructure) for veriable emergence profile, are recommended.
An 89-year-old man was referred to our hospital for treatment of hepatolithiasis causing recurrent cholangitis. He had undergone a prior Whipple procedure. Computed tomography demonstrated left-sided hepatolithiasis. First, we conducted peroral direct cholangioscopy (PDCS) using an ultraslim endoscope. Although PDCS was successfully conducted, it was unsuccessful in removing all the stones. The stones located in the B2 segment were difficult to remove because the endoscope could not be inserted deeply into this segment due to the small size of the intrahepatic bile duct. Next, we substituted the endoscope with an upper gastrointestinal endoscope. After positioning the endoscope, the SpyGlass digital system (SPY-DS) was successfully inserted deep into the B2 segment. Upon visualizing the residual stones, we conducted SPY-DS-guided electrohydraulic lithotripsy. The stones were disintegrated and completely removed. In cases of PDCS failure, a treatment strategy using the SPY-DS can be considered for patients with hepatolithiasis after a Whipple procedure.
목 적 : TBI의 자세 잡이 과정에서 실시하는 신체 계측과 보상체 제작 과정을 전산화 단층 모의치료기를 이용하고 그 유용성을 평가하고자 한다. 대상 및 방법 : 환자는 누운 자세를 취하고, 전산화 단층 모의치료기를 통해 영상을 얻었다. 이 영상을 Somavision으로 전송하고 영상을 통하여 신체 계측 점에 대해 계측을 하였다. 계측은 피부를 기준으로 계측을 하고, 폐에 대해서 영상을 이용하여 계측을 하였다. 영상으로 계측된 값을 통해 보상체 두께를 결정하였다. 또한 영상을 통한 보상체 위치를 결정하 고 확인하였다. 선량은 치료실에서 열형광소자를 이용하며 측정하였다. 결 과 : 신체 계측점에서 두께에 대하며 $1{\sim}2cm$의 일반 계측과 영상 계측의 차이를 보였다. 신체 길이는 일반 계측과 영상 계측이 $3{\sim}4cm$의 차이가 있었다. 또한, 영상을 통해 보상체의 밑그림을 그릴 수 있었다. 열형광소자를 이용한 선량 측정 결과 값은 머리, 목, 액와 ,가슴(폐 포함), 무릎 부위는 $92{\sim}98%$로 측정되었고 배, 골반, 서혜부, 발 부위는 $102{\sim}109%$로 측정되었다. 결 론 : TBI의 자세 잡이 과정에서 전산화 단층 모의치료기의 영상을 이용하는 것은 유용하였다. 신체 계측 점두께는 일반 계측과 영상계측의 차이가 적게 계측되었고, 길이에 대한 계측은 정확하게 이루어졌다. 영상을 이용한 계측은 신체 밀도까지 고려한 다양한 보상체 제작이 가능성을 보여주었다. 또한 보상체 위치 잡이를 정확하게 할 수 있고, 보상체의 모 양도 제한 받지 않고 쉽게 제작할 수 있다. 전체적인 치료실 자세 잡이 시간을 $15{\sim}20$분 단축할 수 있었고, 보상체 제작 시간은 약 15분 감소시켰다.
본 연구에서는 한국인의 두개골 측방향 방사선 검사 영상을 통해 안와이공선(OML)과 아래턱뼈 몸통(Body of mandible) 각도 간의 상관관계를 알아보고, 임상에서 PNS Water's view 검사 시 자세 잡이의 용이성과 정형화된 영상 구현을 위한 검사 자세에 대한 새로운 기준을 제시하고자 한다. 상급종합병원 방사선 검사실에 내원한 환자 중 두개부 측방향 방사선 검사를 시행한 총 202명의 영상과 두부 팬텀을 대상으로 진행하였고, X선 발생 장치와 EOS 장비를 사용하여 두부 팬텀 영상을 획득하였다. 본 연구는 PACS를 이용하여 환자의 두개부 측방향 영상에서 OML과 아래턱뼈몸통 각에 관련된 약어를 설정하여 턱뼈 가지 각(RIA), 정확한 OML 각(TIA), OML과 IR의 각(OIA), 아래턱뼈 길이(TML), 턱뼈 가지 높이(RH), 턱 끝점, 턱뼈 각점, 관절 돌기점이 이루는 각(MA)을 측정하였고, 두부 팬텀을 이용하여 유효성을 확인했다. RIA의 연령별 평균값 범위는 22.67~26.04°이었고, 남성은 23.14°, 여성은 24.78°로 측정되었다. 연령에 따른 TIA와 OIA의 평균값 범위는 35.98~38.31°와 72.27~75.25°이었고, 남성은 36.74°와 72.73°, 여성은 36.43°와 73.38°로 나타났다. TML과 RH의 연령별 크기는 85.73~89.60 mm와 62.60~70.87 mm의 범위로 나타났고, 남성과 여성의 값은 각각 90.54 mm 70.78 mm와 85.13 mm, 61.54 mm이었다. MA의 연령별 평균값의 범위는 55.95~58.63°이었으며, 남성은 57.96°, 여성은 57.76°이었다. 각 변수 간 상관관계 분석 결과 RIA와 OIA, TIA는 양의 상관관계를 나타내었다. 본 연구 결과, 아래턱뼈몸통 각과 OML 과의 관계가 양의 상관성을 나타내는 것으로 보아 아래턱뼈를 영상 수용체에 수직으로 조정하는 방법을 적용한다면 PNS Water's 검사 시 보다 정확한 영상 구현에 도움이 될 것으로 사료되며, 새로운 자세 잡이를 위한 기준으로 활용가치가 있다고 생각된다.
It is the purpose of this study to characterize oral symptoms and to comprehend the cause and the relapse possibility of patients with open bite. This case study examines the orthodontic treatment of a group of female patients with open bite and Angle's Class I malocclusion. A cephalograph of the patient was taken and tracing of the radiograph was completed. In addition to Bjork and Ricketts analysis, additional measurements of specific areas were taken. The occlusal plane was determined by drawing a line connecting the mesiobuccal cusp tip of the maxillary first molar and the incisal edge of the maxillary central incisors. Patients were divided into two groups depending on the relationship between the marginal ridge of the maxillayy first premolar and the drawn line. Those patients with marginal ridges above the occlusal plane were placed into Group 1, while Group 2 subjects exhibited marginal ridges lower than the occlusal plane. The common characteristics within each group and the characteristic differences between each group both prior to and after orthodontic treatment were examined, and finally, the functional oral volume of each patient was analyzed. The results of the case study were as follows: 1. An examination of the skeletal relationship and anatomical form for both Group 1 and 2 showed that all subjects exhibited hyperdivergent skeletal forms, but Group 2 subjects generally demonstrated underdevelopment of the mandible and a smaller articular angle, resulting in an anterior positioning tendency of the mandible. 2. An analysis of the maxillary arches of Group 1 subjects prior to and after orthodontic treatment showed that the antero-inferior direction had changed to an antero-superior directional tendency, while the maxillary arches of the Group 2 patients showed a trend from an antero-superior direction to an antero-inferior relationship. The mandibular arches in both groups showed a change to an antero-superior direction. 3. Functional space analysis showed that Group 2 patients exhibited a greater tendency of haying palatal planes that drop in a postero-inferior direction, resulting in a more severe open bite than their Group 1 counterparts. The results of this case study show that although patients belonging to either Group 1 or 2 exhibited few external differences in the appearance of open bite, an examination of the dental and skeletal relationships by analyzing patient cephalographs showed that patients presenting with flat maxillary occlusal planes exhibited more severe open bite relationships than patients with curved occlusal planes.
본 논문에서는 척추측만증 환자의 진료를 위하여 필요한 Whole Spine Scanography 검사에서 촬영거리, 환자자세(전후 후전 방향), 흉부벽두께, 갈비뼈두께, 폐조직두께, 관전압, 고전압정류방식의 변화에 따른 유방의 입사선량의 차이에 대한 정량적인 자료를 제시하고자 하였다. 환자의 자세(전후방향과 후전방향)에 따른 유방 입사선량의 저감효과를 확인하기 위하여 관전압 90 kVp, 커마 0.1 mGy, 촬영거리 260 cm, 관전압의 리플율이 0인 인버터정류방식, 필터의 두께 3.5 mm, 환자의 흉벽의 두께 120 mm를 조건으로 Simulation of X-ray Spectra program을 이용하여 시뮬레이션 하였다. 그 결과 알루미늄 필터 두께 3.5 mm에서 2.6배, 흉벽의 두께 120 mm에서 25.7배, 고 관전압에서 1.43배, 관전압 리플율 0에서 1.14배의 선량 저감효과가 있었다. 각각의 입사 선량저감효과의 총합은 약 109배이었다. RANDO phantom의 자세(전후방향과 후전방향)에 따른 선량 저감효과를 확인하기 위하여 촬영거리 260 cm, 관전압 90 kVp, 관전류 270 mA, 촬영시간 0.31 sec, 관전압의 리플율이 0인 인버터정류방식, 필터의 두께 3.5 mm을 조건으로 측정한 결과 유방의 입사선량은 전후 방향에 비하여 후전방향이 평균 20.56배의 선량 저감효과가 있었다.
Kim, Myung-In;Kim, Jun-Hwa;Jung, Seunggon;Park, Hong-Ju;Oh, Hee-Kyun;Ryu, Sun-Youl;Kook, Min-Suk
Maxillofacial Plastic and Reconstructive Surgery
/
제37권
/
pp.36.1-36.7
/
2015
Background: This study was performed to evaluate three-dimensional positional change of the condyle using three-dimensional computed tomography (3D-CT) following unilateral sagittal split ramus osteotomy (USSRO) in patients with mandibular prognathism. Methods: This study examined two patients exhibiting skeletal class III malocclusion with facial asymmetry who underwent USSRO for a mandibular setback. 3D-CT was performed before surgery, immediately after surgery, and 6 months postoperatively. After creating 3D-CT images by using the In-vivo $5^{TM}$ program, the axial plane, coronal plane, and sagittal plane were configured. Three-dimensional positional changes from each plane to the condyle, axial condylar head axis angle (AHA), axial condylar head position (AHP), frontal condylar head axis angle (FHA), frontal condylar head position (FHP), sagittal condylar head axis angle (SHA), and sagittal condylar head position (SHP) of the two patients were measured before surgery, immediately after surgery, and 6 months postoperatively. Results: In the first patient, medial rotation of the operated condyle in AHA and anterior rotation in SHA were observed. There were no significant changes after surgery in AHP, FHP, and SHP after surgery. In the second patient, medial rotation of the operated condyle in AHA and lateral rotation of the operated condyle in FHA were observed. There were no significant changes in AHP, FHP, and SHP postoperatively. This indicates that in USSRO, postoperative movement of the condylar head is insignificant; however, medial rotation of the condylar head is possible. Although three-dimensional changes were observed, these were not clinically significant. Conclusions: The results of this study suggest that although three-dimensional changes in condylar head position are observed in patients post SSRO, there are no significant changes that would clinically affect the patient.
전산화단층촬영 유도하 폐 병소의 생검(CT guided lung biopsy)시 환자의 움직임을 최소화 하는 것은 시술에 있어 중요한 요소이다. 이에 움직임을 최소화 하고자 진공 고정기구(vacuum cushion)를 사용하여 그 효용성을 평가하였다. 연구대상은 자세 고정 및 호흡 조절이 잘 협조된 환자 40세 이상, 총 116명을 대상으로 하였다. 자세 측정은 폐 병소 생검 병변의 각 위치에 따라, 바로누운자세, 엎드린자세, 사방향자세, 측와위자세로 측정 하였다. 측정 위치는 해부학적 자세 기준으로 전방향, 후방향, 우측, 좌측에서 측정하였다. 엎드린자세에서 posterior의 미사용의 평균과 사용의 평균차는 1.7905이며 t=2.913(p<0.01)로 미사용/사용의 평균 차이는 통계적으로 유의미하다. 오른쪽방향의 미사용 평균과 사용 평균의 차는 2.4105로 나타났으며 t=3.684(p<0.01)로 왼쪽방향의 평균 차이 또한 유의미했다. 오른쪽방향의 미사용 평균과 사용 평균 차는 2.3263이며 t=3.791(p<0.01)로 미사용과 사용의 평균 차이는 통계적으로 유의미하다. 통계 분석 결과 고정기구를 사용하여 폐 병소의 생검을 시술 한 경우가 모든 자세에서 움직임이 적었다. CT유도하 폐 병소의 생검의 시술시 고정기구를 활용하여 보다 정확한 생검시술과 환자의 자세 움직임을 최소화 할 수 있음에 대한 연구를 진행하였다는 데에 의의가 있다고 사료된다.
목적: 유방암 환자치료 과정에서 breast board를 이용한 방사선 치료시, 환자 위치 재현성을 향상시킬 수 있는 방법론을 개발하고, 효용성을 검증한다. 대상 및 방법: 환자와 breast board 사이에서 기존의 오목한 두개골 판 사용시 발생할 수 있는 오차를 개선하기 위해서, 두경부 지지대를 breast board에 장착할 수 있도록 개조한 장치를 개발하였다. 이 장치가 breast board에 장착된 상태에서 두부(頭部)의 위치를 측정할 수 있는 계측도구를 사용하여, 체중이 다른 2명의 자원자에 대해 각각 50회에 걸쳐 재현성을 검증하였다. breast board의 좌우 방향의 기울어짐을 방지하기 위하여서는, breast board 상하부에 지지대를 장착하여 높이에 맞게 아크릴 판을 삽입하여 좌우를 고정하는 계단형 좌우 고정장치와, breast board 측면에 홈으로 연결된 두 개의 알루미늄 지지대를 장착하여, 수평계로 보정된 높이를 고정시킬 수 있는 팔걸이형 좌우 고정장치를 개발하였다. 장치의 유무에 따라 좌우의 편중 하중에 대한 breast board의 좌우 높이(기준 위치) 변화를 수회 측정하여, 기울어짐의 전도를 수치적으로 환산함으로써 장치의 효용성을 검증하였다. 결과: Cranio-caudal 방향 오차에 대해서는 50 kg, 70 kg의 체중을 가진 2명의 자원자에 대하여 5단계(3 cm, 10 cm, 20 cm, 30 cm, 39 cm)의 breast board 높이에 따라 각각 10회씩, 기존의 오목한 두개골 판과 개선된 두경부지지대를 비교하여 실험을 수행한 결과, cranio-caudal 방향 위치의 표준편차가 평균 $55\%$ 이상 감소하였다. 계단형 좌우 고정장치의 효용성을 검토한 결과 50 kg, 70 kg 체중의 자원자에 대하여 각각 $73\%$, $85\%$ 이상의 기울기 감소 효과가 나타났고, 팔걸이형 좌우 고정장치에 대해서는 각각 $90\%$ 이상의 기울기가 감소한 것으로 나타났다. 결론: 모의 실험 결과, 개선된 두경부 지지대와 좌우 고정장치를 통해 cranio-caudal 방향 위치와 breast board의 기울기의 편차가 기존에 비해 현저하게 감소하였으므로, 임상적용시 환자 위치의 재현성 향상에 기여할 것으로 기대된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.